Vionet VIOR4, VIOR6-12, VIOR6-24, VIOR6, VIOR10 Installation & Operation Manual

...
INSTALLATION & OPERATION MANUAL
For Models:
GAS RANGES
GAS RANGES WITH GRIDDLES
This manual contains important information regarding your VIONET unit. Please read the manual thoroughly prior to equipment set-up and operation maintenance. Failure to comply with regular maintenance guidelines outlined in the manual may void the warranty. Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read this manual thoroughly before installing or servicing this equipment.
MUST READ!
1
Range Owner’s Manual Rev 20190121
As continued product improvement is a policy of Vionet, specifications are subject to change.
8830 Siempre Viva Road Suite 100 | San Diego CA 92154 | https://www.vionetequipment.com
Congratulations! You have purchased one of the finest pieces of commercial cooking equipment
FIRE HAZARD FOR YOUR SAFETY
supplier
on the market. You will find that your new equipment, like all VIONET equipment, has been designed and manufactured to meet the toughest standards in the industry. Each piece of VIONET equipment is carefully engineered and designs are verified through laboratory tests and field installations. With proper care and field maintenance, you will experience years of reliable, trouble­free operation. For best results, read this manual carefully.
Thank you for purchasing and using our product. All the information and guidelines of this user’s manual comply with certain applicable regulations, which come out from our long-term accumulated knowledge and experience as well as current project development situations. Should you have any question, please do not hesitate to contact as shown in back cover p age of this manual.
For safety purpose and efficient operation, please make this document available to users for reference. Do have them to read this manu al ca re fully before they carry out any action on this device, especially when starting.
The manufacturer declines any responsibility in the event users do not follow the instructions or guidelines stated here.
The user’s manual should be placed close to the device, in convenience of users’ reading before operation. We have the full authority to reserve the further technical changes of the device, in the scope of further performance improvement character i sti c d ev el opm ent.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
Keep area around appliances free and clear of combustibles.
Purchaser of equipment must post in a prominent location, detailed instructions to be
followed in the event the operator smells gas. Obtain the instructions from the local gas
2
Range Owner’s Manual Rev 20190121
As continued product improvement is a policy of Vionet, specifications are subject to change.
8830 Siempre Viva Road Suite 100 | San Diego CA 92154 | https://www.vionetequipment.com
Table of Contents
local codes. Failure to install this equipment properly can result in injury or death.
Functional Introduction --------------------------------------------------------------------- Page 4 Specification & Diagrams ----------------------------------------------------------------- Page 5 Installation ------------------------------------------------------------------------------------- Page 8 Precautions & Recommendations ------------------------------------------------------ Page 8 Operation -------------------------------------------------------------------------------------- Page 9 Routine Inspection -------------------------------------------------------------------------- Page 12 Cleaning & Maintenance ------------------------------------------------------------------ Page 12 Failure Analysis & Trouble Shooting --------------------------------------------------- Page 14 Warranty Information ----------------------------------------------------------------------- Page 15
Any self-modification, wrong installation, adjustment or maintenance can lead to property loss
or casualty. Please contact the manufacturer for any adjustment or maintenance, and have the work done by a trained & qualified person.
For your safety sake, please keep the machine away from any liquid, gas or other object which
is flammable or explosive.
This appliance should not be operated by those who have physiological, perceptual or mental
disabilities or those who have insufficient experience or knowledge (including children). Only in conditions of being given sufficient supervision & guarantee of personal safety, as well as proper instructions & guidance, those who were mentioned above can make some particular operation of this device.
Keep children away from the device.Preserve this manual safely. When passing on/selling the device to a third party, the manuals
must be handed over along with the device. All users must operate the device complying with the user’s manual and related safety guidelines.
If the appliance is placed near walls, partitions or kitchen furniture and the like, it is advisable
to make these facilities w i th non-combustible material, otherwise cover them with non­combustible heat-r es is tant ma t eri al , and pay attention to fire preventi on reg ul ati o ns .
The appliance should be installed in a well-ventilated area with exhausting facilities, which may
ensure that all burnt gases produced during combustion process are completely exhausted.
The appliance is only applicable to low-pressure gas regulating valve. It may lead to loss and
casualty if other regulating valves are used.
Do not seal the screw on the gas valve with seal welding.Fire warning: If you smell the gas, please keep away from fire. Do not light up any device or
touch the electronic switch. Do not use any phone in the building either. Close the main gas valve immediately and c all the pro fessional personnel to maintai n it. O per ati o n or improperly maintained will lead to large gas leakage or deflagration easily. The manufacturer will not bear any responsibility for fire accidents caused by improper operation or maintenance.
FIRE, INJURY or DEATH HAZARD
This equipment must be installed by a qualified installer in accordance with all federal, state and
3
Range Owner’s Manual Rev 20190121
As continued product improvement is a policy of Vionet, specifications are subject to change.
8830 Siempre Viva Road Suite 100 | San Diego CA 92154 | https://www.vionetequipment.com
Spe
Model
Dimension
24” X 32.5” X 24.75”
36” X 32.5” X 24.75”
60” X 32.5” X 24.75”
Oven Capacity
20.5”W X 26”D X 14”H
26.75”W x 25.75”D x 14”H
(2)
26.75”W x 25.75”D x 14”H
BTU Oven
30,000 BTU
30,000 BTU
30,000 BTU
BTU Burner
4 x 30,000 BTU
6 X 30,000 BTU
10 X 20,000 BTU
BTU Griddle
N/A
-12 1 X 20,000 BTU
-24 2 X 20,000 BTU
-24 2 X 20,000 BTU
NATURAL
10.0” W/C
NATURAL
10.0” W/C
NATURAL
10.0” W/C
cification
VIOR4 VIOR6 VIOR10
GAS PRESSURE
As continued product improvement is a policy of Vionet, specifications are subject to change.
8830 Siempre Viva Road Suite 100 | San Diego CA 92154 | https://www.vionetequipment.com
VIOR4 VIOR6, VIOR6-12, VIOR6-24 VIOR10, VIOR10-24
4.0” W/C LPG
4.0” W/C LPG
4.0” W/C LPG
4
Range Owner’s Manual Rev 20190121
INSTALLATION
NOTE: it is vital that the purchaser of this equipment post in a prominent location instructions to be followed in the event that the user smells gas. This information shall be obtained by consulting the local gas supplier. The purchaser of this equipment must post in a prominent location.
1. Read this manual thoroughly before installation and operation. DO NOT proceed with installation and operation if you have any questions or do not understand anything in this manual. Contact your local representative or VIONET first.
2. Select a location for the Range that has a level, solid, nonskid surface that is nonflammable and away from water hazards or sinks, and is in a well-lighted work area away from children and visitors.
3. This equipment but be installed under a proper ventilation as required by local code.
*NOTICE: Local codes regarding installation and ventilation vary greatly by area. The National Fire Protection Association states in its NFPA 96 latest edition (see NFPA page at the beginning of this manual) that local codes are “authority having jurisdiction” when it comes to requirements for installation of equipment. Therefore, installation should comply with all local codes.z
4. Level the range with a spirit level on the oven rack. The height can be adjusted by the adjustable feet. The adjustable feet have an adjustment of one inch. Do not slide unit with legs mounted. Lift if necessary to move unit. Do not sway or tilt during operation.
5. The supplied gas pressure regulator is factory set at 10” L.P Gas or 4 Natural Gas.
6. THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACE
ONLY. Noncombustible clearances: 6” sides (152 mm), 6” rear (152 mm), 6” floor (102 mm).
7. Do not obstruct the flow of combustion and ventilation air under the unit by the legs or behind the unit by the flue. Do not place objects between the bottom of the unit and the counter top.
8. There must be adequate clearance for removal of the front panel. All major parts except the burners are removable through the front if the gas is disconnected.
9. A manual gas valve should be installed upstream the device where is easy to be reached before installation in the event of an emergency to shut of the fuel supply to the range.
10. It may be necessary to adjust the balance off gas volume and air supply to each burner. This must be done by and authorized service technician.
11. Pipe threading compound must be resistant to the action of liquefied petroleum gas. DO NOT USE TEFLON TAPE.
The installation of this appliance must conform to local codes, or in the absence of local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1, as applicable.
The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ PSI (3.5kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to less than ½ PSI (3.5kPa).
5
Range Owner’s Manual Rev 20190121
As continued product improvement is a policy of Vionet, specifications are subject to change.
8830 Siempre Viva Road Suite 100 | San Diego CA 92154 | https://www.vionetequipment.com
Loading...