This manual contains important information regarding your VIONET unit. Please read the manual thoroughly prior to equipment Failure to comply with regular maintenance guidelines out-lined in the manual may void the warranty. Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read this manual thoroughly before installing or servicing this equipment.
MUST READ!
1
Owner’s/Installer Manual Rev 1E
As continued product improvement is a policy of Vionet, specifications are subject to change.
8830 Siempre Viva Road Suite 100 | San Diego CA 92154 | https://www.vionetequipment.com
SAFETY PRECAUTIONS
the operator smells gas. Obtain the instructions from the local gas supplier
Before installing and operating this equipment, be sure everyone involved in its operation is fully trained and aware of precautions. Accidents and problems can be caused by failure to follow fundamental rules and precautions. The following symbols, found throughout this manual, alert you to potentially dangerous conditions to the operator, service personnel, or to the equipment.
This symbol refers to a potential hazard or unsafe practice that could result in injury or death.
This symbol refers to a potential hazard or unsafe practice that could result in injury, product damage, or property damage.
NOTICE
FOR YOUR SAFETY TO AVOID SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE:
ALWAYS install equipment in a work area with adequate light and space.
ONLY operate on a solid, level, nonskid surface that is nonflammable and away from sinks and
water hazards.
NEVER bypass, alter, or modify this equipment in any way from its original condition. Doing so may create hazards and will void warranty.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Keep area around appliances free and clear of combustibles. Purchaser of equipment must post in a prominent location, detailed instructions to be followed in the event
VIONET Griddles are intended for commercial use only. Not for household use.
Warranty will be void if service work is performed by other than an authorized technician, or if other than genuine VIONET replacement parts are installed. Be sure this Operator’s/Installer’s Manual and important papers are given to the proper authority to retain for future reference.
This symbol refers to information that needs special attention or must be fully understood, even though not dangerous.
FIRE HA
ZARD FOR YOUR SAFETY
Congratulations! You have purchased one of the finest pieces of commercial cooking equipment on the market. You will find that your new equipment, like all VIONET equipment, has been designed and manufactured to meet the toughes engineered and designs are verified through laboratory tests and field installations. With proper care and field maintenance, you will ex carefully.
perience years of reliable, trouble-free operation. For
t standards in the industry. Each piece of VIONET equipment is carefully
RETAIN THIS MANUAL FOR FURTURE REFERECE
2
Owner’s/Installer Manual Rev 1E
As continued product improvement is a policy of Vionet, specifications are subject to change.
8830 Siempre Viva Road Suite 100 | San Diego CA 92154 | https://www.vionetequipment.com
best results, read this manual
Table of Contents
Specifications ---------------------------------------------------------------------------------------- Page 3 Installation -------------------------------------------------------------------------------------------- Page 5 Operation --------------------------------------------------------------------------------------------- Page 9 Seasoning -------------------------------------------------------------------------------------------- Page 10 Cleaning ---------------------------------------------------------------------------------------------- Page 10 Service/Trouble Shooting ------------------------------------------------------------------------- Page 12 Parts --------------------------------------------------------------------------------------------------- Page 13 Warranty ---------------------------------------------------------------------------------------------- Page 14
Read these instructions carefully before attempting installation. Installation and initial startup should be performed by a qualified installer. Unless the installation instructions for this product are followed by a qualified service technic i an (a per s on exper i enc ed in a nd k now le dge ab le with the insta lla tio n of c om mercial gas and/or electric cooking equipment) then the terms and conditions on the Manuf ac tur er’s Limited will be rendered void and no warranty of any kind shall apply.
Warranty
SPECIFICATIONS
GAS and GAS PRESSURE
This unit is factory supplied in L.P Gas. This unit can be converted to Natural gas by a
licensed and certified gas technician. Documentation may be necessary for warranty issues. Failure to comply with this instruction will void warranty.
Unit ins National Gas Installation Code, CSA-B149.1, or the Propane Installation Code, CSA-B149.2 as applicable and in accordance with local codes.
The applianc from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2" P.S.I. (3.45kPa).
These model
Instruc smells gas. Safety information can be obtained from your local gas supplier.
s are designed, built, and sold for commercial use only.
tions must be posted in a prominent location. All safety precautions must be taken in the event the user
tallation must conform to the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the
e and it’s individual shutoff valve (to be supplied by user) must be disconnected
3
Owner’s/Installer Manual Rev 1E
As continued product improvement is a policy of Vionet, specifications are subject to change.
8830 Siempre Viva Road Suite 100 | San Diego CA 92154 | https://www.vionetequipment.com
SPECIFICATIONS (Continued)
Griddle Front
48” Thermostat Griddle
36” Manual Griddle
36” Thermostat Griddle
Model
Description
BTU.hr
Number of Burners
Gas Type
Gas Griddle 24”
60,000
2
Natural Gas or Propane*
Gas Griddle 36”
90,000
3
Natural Gas or Propane*
Gas Griddle 48”
120,000
4
Natural Gas or Propane*
Use for all Manual Griddles
Use for a Therm
ostat Griddles
24” Manual Gri
24” Thermostat G
ddle Top
riddle Top
24” Manual & Thermostat
VIOGR24 VIOGR24T
VIOGR36- VIOGR36T VIOGR48
VIOGR48T
*Shipped setup for L.P. Gas and includes a kit for conversion to Natural Gas
As continued product improvement is a policy of Vionet, specifications are subject to change.
48” Manual Griddl
e
4
Owner’s/Installer Manual Rev 1E
8830 Siempre Viva Road Suite 100 | San Diego CA 92154 | https://www.vionetequipment.com
UNPACKING
and water solution before operating the unit.
Unpack the Griddle immediately after receipt. Remove the Gas Griddle from the crate; remove all packaging on and surrounding the unit and be certain to remove all protective plastics and residues from all surfaces. Make sure that all parts provided are located. Equipment must have the legs properly installed before use. Before using this equipment it must be cleaned and dried thoroughly.
INSTALLATION
NOTE: it is vital that the purchaser of this equipment post in a prominent location instructions to be followed in the event that the user smells gas. This information shall be obtained by consulting the local gas supplier. The purchaser of this equipment must post in a prominent location.
1. Read this manual thoroughly before installation and operation. DO NOT proceed with installation and operation if you have any questions or do not understand anything in this manual. Contact your local representative or VIONET first.
2. Select a location for the Griddle that has a level, solid, nonskid surface that is nonflammable and away
ater hazards or sinks, and is in a well-lighted work area away from children and visitors.
from w
3. This equipment but be installed under a proper ventilation as required by local code.
Local codes regarding installation and ventilation vary greatly by area. The National Fire Protection Association states in its NFPA 96 latest edition (see NFPA page at the beginning of this manual) that local codes are “authority having jurisdiction” when it comes to requirements for installation of equipment. Therefore, installation should comply with all local codes.
4. Screw legs into (A) the permanently fastened nuts on the four corners of the unit and tighten by hand. Legs must be installed to adequately provide proper ventilation to the unit.
5. Level unit by adjusting the four feet and tighten securely. The adjustable feet have an adjustment of one inch. Do not slide unit with legs mounted. Lift if necessary to move unit.
6. The supplied gas pressure regulator is factory set at 4” Natural Gas W.C. or 10” Propane Gas.
7. THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACE ONLY.
Noncombustible clearances: 6” sides (152 mm), 6” rear (152 mm), 4” floor (102 mm).
8. Do not obstruct the flow of combustion and ventilation air under the unit by the legs or behind the unit by the flue. Do not place objects between the bottom of the unit and the counter top.
9. There must be adequate clearance for removal of the front panel. All major parts except the burners are removable through the front if the gas is disconnected.
10. It may be necessary to adjust the balance of gas volume and air supply to each burner. This must be done by and authorized service technician.
11. Pipe threading compound must be resistant to the action of liquefied petroleum gas. DO NOT USE TEFLON TAPE.
DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap
The installation of this appliance must conform to local codes, or In the absence of local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1, as applicable.
The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ PSI (3.5kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to less than ½ PSI (3.5kPa).
As continued product improvement is a policy of Vionet, specifications are subject to change.
8830 Siempre Viva Road Suite 100 | San Diego CA 92154 | https://www.vionetequipment.com