Viola Systems Symphony Owner's Manual

Revision: 01
---------------------------------------------------------------------------
SYMPHONY POWER AMPLIFIER
OWNER’S MANUAL
-------------------------------------------------------------------------------
© Viola Audio Laboratories 2004, 2005
The information contained in the manual is subject to change without notice. The most current version of this manual will be posted on our web site at www.Violalabs.com.
P/N: 91-symphonymanual
TABLE OF CONTENTS
Safety Instructions 3
Introduction 4
Unpacking 4
Voltage Setting 4
Location 5
XLR Connector Pin Assignment 5
Speaker Cable Connection 6
o Cables and Connectors 6 o Single Speaker Cable Connection 6 o Bi-Wire Connection 7 o Bridge Connection 8
Bi-amplification 9
AC Power Cable Connection 10
Switching on for the First Time 10
Breaking In 10
Care and Cleaning 11
Fuses 11
Troubleshooting 12
Warranty 13
Service 14
Contacting VIOLA 14
Specifications 16
Viola Symphony Manual Rev 1 2 of 15 9
th
September 2005
IMPORTANT SAFETY INSTRUCTIONS
Please read all of the following instructions carefully before operating your power amplifier.
1. The VIOLA Symphony weighs approximately 120lbs (54kg). NEVER try to move it on your own. Always use two people to move or unpack the unit. Take care to lift using your legs and avoid straining your back.
2. This product contains no user serviceable parts. NEVER attempt to repair the unit yourself. Refer all servicing to a VIOLA approved technician.
3. This product must be connected to the mains supply with a three­conductor AC mains power cord that includes a ground connection. To prevent shock hazard, all three connections must ALWAYS be used. NEVER defeat the ground connection.
4. ALWAYS disconnect your entire system from the AC mains before connecting or disconnecting any cables, or when cleaning any component.
5. NEVER operate this unit with any covers removed. Dangerous voltages may exist within the unit even when it is disconnected from the mains supply.
6. We do not recommend the use AC extension cords with this product. If it is necessary to use an extension cord, please ensure that it meets safety standards in your country and has sufficient current capacity. (100V to 120V – 15A minimum, 220V to 240V 10A minimum).
7. NEVER use flammable chemicals for cleaning this product.
8. NEVER wet the inside of this product with any liquid, or operate the unit in a wet environment.
8. NEVER block airflow through the ventilation slots on either the top or the bottom of the unit.
9. NEVER bypass any fuses.
10. NEVER replace any fuse with a value or type other than those specified. Suitable replacements are available from your local VIOLA dealer, national distributor or directly from VIOLA.
11. NEVER expose this product to temperatures outside the range 0°C
Viola Symphony Manual Rev 1 3 of 15 9
th
September 2005
to 55°C non-condensing.
12. ALWAYS disconnect the unit from the mains supply during lightning storms, or if the unit will not be used for a prolonged period.
INTRODUCTION
TRODUCTION
Thank you for choosing the VIOLA Symphony Amplifier. Great care has gone into the design and manufacture of the Symphony and if properly used, it will give a lifetime of musical enjoyment. We strongly recommend that you read these instructions before you attempt to use the unit, so that you can be sure it is set up to give optimum performance.
UNPACKING
The VIOLA Symphony Power Amplifier is heavy - the shipping weight is approximately 120 pounds (55 kilograms). To avoid the risk of both personal injury and damage to the product, do not attempt to lift it from its packing carton alone. We recommend you use two people to unpack this amplifier safely.
Never attempt to lift the unit while bending from the waist. Always stand as straight as possible and use your leg muscles to lift.
Please keep all of the packing materials in case you ever need to ship the unit. Should you need to return the unit to the factory , you must use the original, shipping carton. The use of any other packing ma y result in the product sustaining damage in transit. Such damage is not covered by the warranty. Replacement shipping cartons may be obtained via your VIOLA dealer, or directly from the factory.
After unpacking the unit , please confirm that the following items are present:
1 Viola Symphony power a mplifier 1 user manual 1 three-conductor mains cord
If any of the above items are missing, or if the amplifier shows any signs of damage, please contact your VIOLA dealer immediately.
VOLTAGE SETTING
Before going any further please, confirm that the unit is set to operate on the mains voltage you plan to use. The setting is marked on the unit’s rear panel above the right hand fuse. If the setting on your unit is not correct, contact your VIOLA dealer. Only a VIOLA approved technician should change the voltage setting. Do not attempt to do this yourself. Should you set the unit to the wrong voltage, you risk
Viola Symphony Manual Rev 1 4 of 15 9
th
September 2005
personal injury and you may also cause serious damage to the unit which will void the warranty.
LOCATION
We recommend that you place the amplifier as close to the loudspeakers as possible, as this reduces the length of speaker cable required. Whilst this make it necessary to use longer interconnect cables, lo ng interconnects cause less sonic degradation
than long speaker cables.
The unit may be placed on a stand or shelf, provided it is strong enough. Alternatively it may be placed directly onto the floor. In this case, please ensure that that the ventilation slots on the base of the unit are not obstructed by carpeting or other floor covering.
In all locations please allow a clearance of at least 3.5” (5cm) above the unit. You must also allow a clearance of at least 6” (15 cm) behind the unit, to enable the cables to be routed without being subject undue strain.
Regardless of where you locate your amplifier, we advise positioning it well away from sensitive low signal level components such as pre-amplifiers and turntables. The Symphony power amplifier dissipates approximately 225 watts as heat when idling (i.e. no input signal). It is normal and perfectly safe for it to run somewhat warm to the touch.
XLR CONNECTOR PIN ASSIGNMENT
The Symphony is fitted with XLR and Fischer type balanced inputs. The pin assignments of the Symphony’s XLR input conforms to the AES 14 standard, which is now commonly used throughout the audio industry. These assignments are shown below:
Pin 1: Signal ground Pin 2: Signal + (non-inverting) Pin 3: Signal - (inverting) Connector shell: Chassis ground
Some equipment may have the polarity of the signals on pins 2 and 3 of the XLR connectors swapped over. Please refer to the user manuals of the other equipment in your signal chain to conf irm whether this is the case.
If this is the case, it will not cause any damage, but it may reduce the quality of the stereo image, as well as the perceived attack of the bass. This situation is easily remedied by swapping the connections of pins 2 and 3 at either end of one of one set of balanced cables in the signal chain. Alternatively you can swap over the polarity of the speaker leads on both channels. Your dealer should be able to advise you on the best course of action. If two items in the signal path have the connections to pins 2 and 3 of the XLR connector reversed with respect to the AES standard, this cancels out the problem and you need take no further action.
Viola Symphony Manual Rev 1 5 of 15 9
th
September 2005