WhisperKOOL copyrights this manual, the product design, and the design concepts, with all rights reserved. Your rights with
regard to the hardware and manual are subject to the restrictions and limitations imposed by the copyright laws of the USA.
Under copyright laws, this manual may not be copied, reproduced, translated, transmitted, or reduced to any printed or electronic
medium or to any machine-readable form, for any purpose, in whole or in part, without the written consent of WhisperKOOL.
Every eort has been made to ensure that the information in this manual is accurate. WhisperKOOL is not responsible for printing
or clerical errors.
WhisperKOOL reserves the right to make corrections or improvements to the information provided and to the related hardware at
any time, without notice.
Vinothèque and WhisperKOOL are registered trademarks, and ECE is a trademark of WhisperKOOL. All rights reserved.
Mention of third-party products is for informational purposes only and constitutes neither an endorsement nor a
recommendation. WhisperKOOL assumes no liability with regard to the performance or use of these products.
REV 02
PS 033114
TABLE OF CONTENTS
Quick Reference Guide
Evaporator Unit ..........................................
Installation Terms and Conditions ..........................
5
6
7
10
11
14
15
18
19
www.whisperkool.com | Page 1
Platinum Split Evaporator Unit (Fan Coil Unit) Front / Side View
Evaporator Unit (Fan Coil Unit)
QUICK REFERENCE GUIDE
°
Filter Grille
Controller
F
Platinum Split Evaporator Unit (Fan Coil Unit) Rear / Side View
Mounting Key Hole (X4)
THROUGH THE WALL
Option 1
Knock Out For Wiring
Knock Out For Suction Line
Knock Out For Liquid Line
Knock Out For Drain Line
Circular Connection
Mounting Location
Page 2 | 1-800-343-9463
Liquid Line Knock Out
Suction Line Knock Out
INSIDE CELLAR
Option 2
Knock Out For Drain Line
Knock Out For Wiring
PS 033114
QUICK REFERENCE GUIDE
°
F
°
F
°
F
°
F
°
F
Controller Layout
Inactive
View Set Point
Change Set Point
(Press and hold 3-5 sec)
Wall Mounted PLATINUM SPLIT UNIT SPECIFICATIONS
Refer to page 11 for complete listing of buttons and symbols.
°
F
Compressor On
Fans are On
Unit is in Pre-Chill Mode
Alarm is Present
Unit is in Anti-Frost Mode
High History
Scroll Button
Cellar Pre-Chill
(Press and hold 3-5 sec)
Low History
Scroll Button
Power On/O
Model
4000 Evaporator
(Fan Coil Unit)
4000 Condenser
(Air Cooled
Condensing Unit)
8000 Evaporator
(Fan Coil Unit)
8000 Condenser
(Air Cooled
Condensing Unit)
Cellar Size (cu. ft.)10002000
Dimensions
BTUh with 90° air entering
the Condenser Coil
CFM
20.5”w x 15.625”h x
16.0625”d
270190278350
12”w x 13.5”h x 18”d
36504450
20.5”w x 15.625”h x
16.0625”d
12”w x 13.5”h x 18”d
RefrigerantR-134a
Condensing Unit HP1/3++1/2
Voltage Rating
dedicated circuit required)
Weight (lbs)56565666
AMPS
(20 amp
(Starting/Running)2/132.7/7.22/148/9.5
115V or 230V
dBA54655465
Drainline1/2” Condensate
Installation
Evaporator Unit (Fan Coil Unit) is installed in the cellar or up to 25 ducted ft. away, condenser is
installed up to 100 ft from Evaporator Unit (Fan Coil Unit)
ThermostatDigital Control Display
Temp. Delta55°F
Temperature dierential between the cellar temperature and condenser air intake temperature.
Warranty2 year parts and labor
www.whisperkool.com | Page 3
QUICK REFERENCE GUIDE
Platinum Split Evaporator Unit (Fan Coil Unit) Front / Side View
Supply Air
Return Air
°
F
Duct Plenum
Keypad
DUCTED PLATINUM SPLIT UNIT SPECIFICATIONS
4000 Condenser
(Air Cooled
Condensing Unit)
8000 Evaporator
(Fan Coil Unit)
Model
4000 Evaporator
(Fan Coil Unit)
Cellar Size (cu. ft.)10002000
Dimensions23.75”w x 15”h x 22.5”d12”w x 13.5”h x 18”d23.75”w x 15”h x 22.5”d12”w x 13.5”h x 18”d
BTUh with 90° air entering
the Condenser Coil
CFM
200190200350
31203788
RefrigerantR-134a
HP1/3++1/2
Voltage Rating
dedicated circuit required)
(20 amp
115V or 230V
Weight (lbs)57565766
AMPS
(Starting/Running)2/132.7/7.22/148/9.5
8000 Condenser
(Air Cooled
Condensing Unit)
dBA54655465
Drain Line1/2” Condensate
InstallationUse 8” supply and 10” return insulated ducting. Ducting should not exceed 25 ft. from the cellar.
ThermostatOptional Digital Remote Display
Temp. Delta55°F
Temperature dierential between the cellar temperature and condenser intake air temperature.
Warranty2 year parts and labor
Page 4 | 1-800-343-9463
PS 033114
RECEIVING & INSPECTING THE SYSTEM
Receiving and Inspecting the System
• Lift only at the designated hand hold locations on the shipping container or fully support the unit from
underneath. A shipment may include one or more boxes containing accessories.
• Before opening the container, inspect the packaging for any obvious signs of damage or mishandling.
• Write any discrepancy or visual damage on the Bill of Lading before signing.
• Allow the condensing unit to sit for 24 hours prior to start up. The condensing unit can be placed in the
installation location, piped and evacuated during this time.
Note: WhisperKOOL units are manufactured in the USA and tested prior to shipment.
Review the Packing Slip to Verify Contents
• Check the model number to ensure it is correct.
• Check that all factory options ordered are listed.
If any items listed on the packing slip do not match your order information,
contact WhisperKOOL Customer Service immediately.
Check the Box for the following contents:
Main Evaporator Box
°
F
(1) Platinum Split Evaporator Unit
(Fan Coil Unit)
Wall-Mount Accessory Kit
Ducted Accessory Kit
(1) Installation Kit which includes:
(2) ½” 90° Barb ttings
(1) ½” barb tee
(1) 10 ft. 1/2” Drain Line
(4) 1 ¾” hex head screws
(1) Bypass plug
°
F
(1) Filter Grille
Main Condensing Unit Box
(2) Cable tie mounts and cable ties
(1) Black Strain relief
(1) 1/4” sight glass
(1) 1/4” lter drier
(1) Condensing Unit
(1) Platinum Split Tech Manual
(1) Platinum Split Owners Manual
(1) Split System Warranty Checklist
(1) 12 ft. Bottle Probe
(10) 6-32 3/8” Phillips Pan Head Screw
(1) Display Adapter
(1) Platinum Split Tech Manual
(1) Platinum Split Owners Manual
(1) Split System Warranty Checklist
(1) 50 ft. Bottle Probe
(1) Remote Keypad
(1) 50 ft. Keypad Communication Cable
(1) Duct Plenum
Please leave the unit in its original box until you are ready for installation. This will allow you to move the product
safely without damaging it. When you are ready to remove the product from the box, refer to the installation
instructions.
TIP: Save your box and all packaging materials. They provide the only safe means of transporting/shipping the unit.
www.whisperkool.com | Page 5
BEFORE YOU START
1. Inspect all components prior to installation. If damage is found, please contact your distributor or WhisperKOOL
Customer Service at 1.800.343.9463.
2. The Condensing Unit requires a dedicated 115-volt 20-amp circuit. Use a surge protector with the unit. Do not use a GFI (Ground Fault Interrupter) line.
3. It is REQUIRED to install a drain line to remove condensation from the Evaporator Unit (Fan Coil Unit).
4. The system is intended for use in properly designed and constructed wine cellars. Hire a professional wine
storage consultant with a valid contractor’s license to build your wine cellar.
5. WhisperKOOL requires that all Split Systems are installed by a certified HVAC-R technician only, Nate or equivalent is
recommended.
6. Warranty is not active until a Warranty Checklist has been received, reviewed, and approved.
If you encounter a problem with your WhisperKOOL system, please refer to the Troubleshooting Guide on page 15.
If you have any further questions, concerns, or need assistance, please contact WhisperKOOL’s Customer Service at
1.800.343.9463. Please be sure all testing has been completed prior to contacting Customer Service. Please have your