READ BEFORE YOU START
WARM SIDE
1 2 3
LOCATION:
Appliance is for indoor use only. Never vent into a laundry closet or similar room which traps warm air. Unit
must vent to an adjacent interior ventilated space close
to the ceiling. Exhaust air must not be obstructed in any
way.
TEMPERATURES:
Select a suitable area, sized to model’s cooling capacity,
where ambient temperature will not exceed the desired
storage temperature by more than 25ºF (14ºC). The
temperature of the air where the unit vents its warm air
must be at least 65ºF and never exceed 80ºF with 70%
R.H. Lower set temperature from default 57ºF (14ºC)
only if ambient condition allows.
Set temperature range: 52ºF - 64ºF (11ºC - 18ºC)
INSULATION:
Install unit where ALL surfaces (walls, oor and ceiling)
are insulated to R-20 and protected by vapor barrier on
both sides. Uninsulated concrete oors will radiate heat
and humidity during summer months, forcing the unit to
work inefciently. All oors must be INSULATED! Use an
insulated door with weather seal.
POWER:
Outlet (on cool side) power must be a dedicated separately fused grounded 15-Amp 115 Volt line within reach of
supplied power cord (Europe; 10-Amp 220 Volt). Line
must not be shared. Do not use extension cords.
Electronics must be protected against sudden power
surges. Use a quality surge protector.
SPECIAL NOTE:
This unit is constructed for installation in walls up to 6
1/2” inches thick. If you install it in a thicker wall you will
have to cut out an area around the air vents on the cool
side in order to keep cool airow unobstructed. Order
longer screws at www.koolrproducts.com.
MARK SLITS
1 2 3
COOL
4 5 6
SIDE
!
WARM
SIDE
CENTER
• Center pattern to door frame.
• Trace pattern.
• Flip pattern and repeat for cool side.
FRAME
4 5 6
!
• Slide over frame on cool side, guide cord
through frame side notch.
• Screw in cooling unit to frame.
• Place grill on unit.
Watch for live wires !•
• Cut out drywall, warm and cool side.
• Cut out Stud level to drywall cutout.
CONTAINER
WATER DRAIN
• Add tube to elbow.
• Insert elbow to cooling unit.
• NOTE: Excess condensation is caused by extreme
conditions. This is not required if your room is properly insulated.
!
CAUTION!
TUBE
ELBOW
• Get help to insert cooling unit through hole.
• Guide cord, do not damage drywall!
RECOMMENDED
OVER THE DOOR
INSULATION
MINIMUM R-20
DRYWALL
VAPOR BARRIER
CUTOUT
INSULATION
(MIN. R-20)
ALTERNATIVE
WALL CUTOUT
PLYWOOD
FLOOR
ODORLESS
WATERPROOF
VAPOR
BARRIER
c
PAINT
Min.5”
Min. 2’
lear
space
Min. 6’
SILICONE CAULKING
Min
10”
SEAL ALL
JOINTS
INSULATED
DOOR
WITH
AIRTIGHT
SEAL
ALTERNATE WALL CUTOUT
• Level pattern, trace both warm and cool side.
• Cut out drywall.
• Screw in cooling unit to frame.
DRYWALL
VAPOR BARRIER
WARM SIDE
CENTER
PREPARING FOR INSTALLATION
TROUBLESHOOTING GUIDE
INSULATION :
VAPOR BARRIER :
SEAL :
POWER SUPPLY :
Floor, ceiling and all walls of the enclosure must be insulated to minimum R-20 rating, although R-30 is recommended.
Best material is foil-backed urethane foam, sealed at all joints with thermal tape. Build a proper sub-oor with a vapor
barrier, and insulate to at least R-20, especially if oor is concrete. Use an insulated door.
All surfaces of the enclosure must be protected by a proper vapor barrier, ideally on both inside and outside of wine/
pantry room.
Seal corners, joints, gaps, vents, electrical outlets and switches, and especially around door and frame. Pack larger
gaps with insulation. Seal all seams with silicone caulking. Seal drywall with odorless waterproof paint.
This unit must be installed in accordance with national wiring regulations. Do not use if power cord is damaged; it must
be replaced by the manufacturer or its service agent or by a qualied person to avoid a hazard. Plug must remain
accessible after installation. Electrical service must be a dedicated, separately fused and grounded 15 Amp, 115V line
(Europe; 10-Amp 220 Volt). Test line voltage before operating, and do not use if line voltage is less than 105V. The unit
must be protected against power surges and spikes. Use a good quality surge suppressor.
CONTROLS : PLUG IT IN ( WAIT ONE MINUTE ) AND ENJOY!
OPERATION:
CONTROLLER
OPERATION
TO DISPLAY: Actual temperature: PRESS 57º 56º
TO MODIFY SET
TEMPERATURE
(range is 52-64ºF):
TO CHANGE FROM
ºF to ºC or ºC to ºF
TO CALIBRATE: PRESS and HOLD while holding PRESS and RELEASE BOTH QUICKLY 57º 57º
NOTE: A negative offset will result in a warmer cabinet and a positive offset will result in a cooler cabinet. The new value will
be memorized and the controller will reset automatically.
ALARM: • If the temperature exceeds 72º F the unit will shut down, a warning sound will start and the display will blink
alternating with the temperature reading.
• This function is disabled in the rst 4 hours “ Cool Down” period or after any reset for another 4 hours.
• The unit will restart and continue the cooling and cycling if the temperature falls below 72º F.
TO RESET: Unplug and re plug the unit.
• Display will show detected temperature until temperature falls within 3º of SET POINT.
• If temperature is above default 57º F + 1º or other preset value, after a delay of 1
minute fan will start, followed by compressor in next minute.
• Unit will cycle ON/OFF based on temperature reading. Fan speeds are automatically
set by controller to achieve optimum performance.
• Minimum ON and OFF cycle times are imposed by software, to prevent “short cycling”.
ACTION DISPLAY EXAMPLE
SET temperature: PRESS 70º 57º
PRESS and RELEASE 57º 57º
To increase: PRESS once per degree 57º 58º
To decrease: PRESS once per degree 57º 56º
The new value will be memorized and the controller will reset automatically.
PRESS and HOLD until buzzer sounds in 5 seconds 57º 14º
The new value will be memorized and the controller will reset automatically.
Wait 5 seconds 57º F0
USE for each degree of positive offset
USE for each degree of negative offset
DISPLAY:
BEFORE AFTER
F0 F1
F0 -1
AL
KEYS
CONDITION CHECK SOLUTIONS
COOLING UNIT
DOES NOT RUN
WHEN PLUGGED IN
COOLING UNIT
RUNS BUT DOES
NOT COOL SUFFI-
CIENTLY
Shipping damage? Contact courier company for shipping damages.
Unit plugged in? Unit has a 1-min. cautionary delay between plugging in and
full start-up; this is a built-in safeguard to protect compressor in case of a sudden power failure.
LED display ON? Unplug unit, remove controller, check/replace fuse (0.5A
slow blow, 250V, 5X20mm).
see manuals at www.koolrproducts.com
Storage temperature properly set? Unit may take a few days to achieve the desired storage
temperature. Decrease your set temperature to cool.
Room properly constructed with all joints airtight?
Door insulated properly? If gaps are visible, then seal door so it is airtight.
Airow to and from the cooling unit unobstructed? Improve circulation of air to and from the unit as directed in
Ambient air temperature within the specied range? Make sure ambient temperature is below 80º
CLEANING THE COIL:
Seal all cracks and joints. Check insulation requirements.
instructions.
Clean the unit regularly, every 3 to 4 months vacuum the
cooling unit coils.
VACUUM PERIODICALLY
Additional Trouble-Shooting information and downloadable documents are available in the “Support” area of our web site:
www.koolrproducts.com
WARNING: If unit is in “Alarm”, unplug the unit immediately. See controls table.
IMPORTANT NOTE:
• Have your wine collection adequately insured.
• Install a battery-powered heat-sensitive alarm to warn of any loss of cooling due to power interruption.
• Monitor your storage and ambient conditions on a regular daily basis.
Be advised Koolr Products Inc. or Shanghai Koolspace Co. Ltd. cannot in any event be liable or responsible for incidental or consequential damages.
ONE YEAR LIMITED WARRANTY
If your Koolr cooling unit or cabinet fails to perform as designed within one year of the date of purchase, Shanghai Koolspace Co. Ltd. warrants that, upon
your request, it will be replaced, during the one year warranty period. This warranty applies only to the rst end-user purchaser of a Koolr cooling unit that
is purchased and used in the continental United States or Canada (excludes Alaska and Hawaii). It is not valid for subsequent purchasers, nor for units in use
outside North America. The warranty period for your Koolr cooling unit commences on the date you purchased it and expires one year thereafter.
PROOF OF PURCHASE
Within 10 days of purchase, complete and mail, fax or e-mail the registration sheet to Shanghai Koolspace Co. Ltd. Alternately, you may register your warranty
on our Internet website, www.koolrproducts.com. When you make a warranty claim, you must forward a copy of your original dated bill of sale to establish
your date of purchase.
WHAT THE WARRANTY DOES NOT COVER
This warranty covers only defects in materials and workmanship provided by Shanghai Koolspace Co. Ltd. and does not cover equipment damage or malfunction
from misuse, abuse, accident, act of God, or any unauthorized alteration or modication. The product must have been installed and operated precisely as directed
in the manual which acompanies each product. Return shipping charges are not covered. Improper return shipping, inadequate packaging or shipping damage
is not covered unless the unit is packaged and shipped in accordance with Shanghai Koolspace Co. Ltd. replacement procedures. Third party servicing of this
product during the warranty period will also void the warranty, as will any evidence of tampering or alteration to the serial number and or the original dated bill of
sale. GO ONLINE FOR MORE WARRANTY INFORMATION AT www.koolrproducts.com.
MARK SLITS
COOL SIDE
CENTER