Vinotemp WINE-MATE WM-1500SS, WINE-MATE WM-1900SS Installation, Operation & Care Manual

wwwwww..wwiinneemmaattee..ccoomm
Installation, Operation & Care Manual
WM-1500SS
WM-1900SS
READ AND SAVE THESE INSTRUCTIONS
wwwwww..vviinnootteemmpp..ccoomm
TABLE OF CONTENTS
Important Safety Information…..........................................2
Cellar Construction…………………………….……………..3 Features & Specifications.…………………….……………..4
Installer’s Instruction……….….……………………………..7 Electrical Wiring……………………………………………...13 Temperature Control………………………………………...15 Care Guide…………………………………………………….16 User’ Troubleshooting…….………………………………...17 Customer Support……………………………………………20 Warranty……………………………………………………….21
- 1 -
Important Safety Information
WARNING:
DO NOT USE A GROUND FAULT INTERRUPTER (GFI).
A DEDICATED 20 AMP CIRCUIT IS REQUIRED.
- 2 -
Cellar Construction
This is only a guide and shall be considered as minimum requirements. All interior walls and floors shall have a vapor barrier and a minimum of R13
insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation. The vapor barrier shall be installed on the warm side of the insulation. All joints, door frames, electrical outlets or switches and any pipes or vents that go through the cellar shall be sealed to prevent air and moisture leakage into the cellar. Concrete, rock, and brick are not insulation or vapor barriers.
Doors shall be of a minimum size, insulated to at least R13 and tightly sealed with high quality weather stripping. Be sure to seal the bottom of the door and fill gap between the door’s frame and wall before installing the cap molding. In order to maintain 55 °F in the wine cellar, the ambient temperature surrounding the enclosure shall not exceed the temperature of the cellar by more than 25 °F. No cellar wall shall receive direct sun or strong wind.
Lighting shall be of low wattage, with a timer to insure lights are not left on when the cellar is not occupied.
The cooling system will not be able to maintain the proper temperature if fresh moisture-laden air is constantly being introduced to the cellar. Symptoms of this condition are; cooling unit runs all the time with only a slight reduction in temperature and/or water overflows from the unit. Because of the temperature difference between the inside and outside, very small cracks can allow large amounts of outside air to enter into the cellar. Please be aware that moisture can pass through solid concrete, paint and wood. Often a newly constructed cellar contains fresh wood, paint, concrete and other building materials. These materials contain large amounts of moisture. When placed into operation in this type of environment, the system will work harder to remove this extra moisture resulting in increased “run” time.
- 3 -
Features and Specifications
Wine-Mate split cooling systems WM-1500SS and 1900SS are designed and used to
provide a cold temperature between 50~65 °F for a properly insulated wine room at a normal environment.
The wine room will maintain humidity of 50~70% RH even when the environment
becomes dry and humid. These temperatures and humilities are optimized for long term storage of wine.
The SS units consist of a condensing unit and an evaporator unit, and they are
connected by a liquid line and an insulated suction line.
The condensing units can be located away from the evaporator units and wine cellars
50 ft, which will bring you quiet operation.
WM-1500SS evaporator unit can be installed on the ceiling in a wine cellar and WM-1900SS evaporator unit can be installed on the wall.
The dimensions (in inches) and capacities are specified as follows:
MODEL EVAP
UNIT
WM-
1500SS
WM-
1900SS
WM-
15SFC
WM-
19SFC
NOTE: CAPACITY IS DETERMINED UNDER THE CELLAR TEMPERATURE, THE CELLAR AMBIENT TEMPERATURE AND THE CONDENSING UNIT AMBIENT TEMPERATURE OF 55 EXTERIOR INSULATIONS. ANY HIGHER AMBIENT TEMPERATURES AND LOWER INSULATIONS WILL CAUSE REDUCING CAPACITY AND THE CELLAR TEMPERATURE MAY NOT BE MAINTAINED AT 55°F.
CAUTION: LOW AMBIENT TEMPERATURE KIT IS REQUIRED IF THE INSTALLATION AREA WILL BE BELOW 50°F.
CAUTION: LIQUID AND SUCTION LINES MAY DIFFER FROM WHAT ARE SHOWN HERE, PLEASE CHECK ON THE UNITS FOR PROPER INSTALLATION.
Parts included:
COND
UNIT
WM-
150SCU 1500/180 150 cu ft R134a
WM-
150SCU 1500/180 150 cu ft R134a
BTU/H,CF
M
(55°F/90°F)
°F, 75°F AND 90°F, WITH R13 INTERIOR AND R19
CAPACITY (55°F/75°F)
REFRIGERANT
ELECTRICAL
EVAP UNIT/ COND UNIT
115V-60HZ-
0.4A/115V-
60HZ-3.1A
115V-60HZ-
2.2A/115V-
60HZ-5.1A
WEIGHT(lb
) EVAP
NIT/
COND
UNIT
15/30
20/30
- 4 -
Condensing Unit (discharge and suction valves installed) + Liquid Filter + Liquid Indicator Evaporator Unit (liquid line solenoid valve and expansion valve installed) Temperature Controller + Air Sensor
Fig. 1 WM15SFC Evaporator Unit
Fig. 2 WM19SFC Evaporator Unit
- 5 -
Fig. 3 WM-150SCU Condensing Unit
Fig. 4 Liquid Filter Fig. 5 Liquid Indicator
- 6 -