Vinotemp WM-2500SSH, WM-4500SSH, WM-6500SSH, WM-8500SSH, WineMate VINO2500SSH Installation Instruction

...
VINO2500SSH, 4500SSH VINO6500SSH, 8500SSH
Installation Instruction
Federal law requires that WINEMATE split cooling systems be installed by an EPA certified refrigeration technician.
1. Location
Leave minimum 3 feet clearance between the exhaust side and the wall.
Leave minimum 1 foot clearance for the fresh air supply side.
Condensing unit should be elevated to avoid possible flooding and shaded
from direct sun. It should not be exposed to temperatures higher than 125
°F or lower than 20 °F.
Air flow from the unit cooler should be unobstructed for at least 1 foot.
2. Refrigeration Installation
Model
VINO2500SSH 3/8 3/8 8 VINO4500SSH 3/8 3/8 8 VINO6500SSH 3/8 5/8 10 VINO8500SSH 3/8 5/8 10
Liquid Line Diameter
(inch), recommended
WINEMATE split system is shipped as components and is ready for use only after a certified refrigeration technician has properly installed and tested the
Suction Line Diameter
(inch), recommended
Pipe (inch)
- 1 -
system. Proper installation is critical. WINEMATE can only warrant the quality of the components. The installation and proper operation of the system must be warranted by the installer. Installation of the system must be done in accordance with all state and local building codes. The condensing unit and unit cooler are connected by a liquid line and an insulated suction line that are supplied by the installer. These lines must be properly sized for the distance between the two units. After the units and the lines are installed, the system must be pressure tested. If no leaks are found, evacuate and charge system with R134A. Refrigerant amount will vary depending on the length of line set.
3. Air Sensor
The air sensor is recommended to place in the wine room. If it is in a return duct, the temperature differential may lead to erroneous readings.
4. Electrical Wiring
We strongly recommend against the use of an extension cord. However, if you still select to use an extension cord, it is absolutely necessary that it is a UL LISTED 3-wire grounding type appliance extension cord. The marked rating of the extension cord should be 115 V, 20 A. or equivalent and not greater than 15ft in length.