Vinotemp 1500SS, 1900SS, WineMate VINO1500SS, WineMate VINO1900SS Installation, Operation & Care Manual

Page 1
WINEMATE Split System
Installation, Operation & Care Manual
VINO1500SS VINO1900SS
VViinnootteemmpp IInntteerrnnaattiioonnaall CCoorrpp..
wwwwww..vviinnootteemmpp..ccoomm
Page 2
READ AND SAVE THESE INSTRUCTIONS
TABLE OF CONTENTS
Important Safety Information…..........................................2
Feature Description…………………………….……………..3 Installation Instruction………………………………………..5 Use and Temperature Control……………………………….7 Care Guide………………………………………………………8 Troubleshooting……………………………………………….9
Customer Support……………………………………………11 Warranty……………………………………………………….12
- 1 -
Page 3
Important Safety Information
• DO NOT USE A GROUND FAULT INTERRUPTER (GFI).
• A DEDICATED 15 AMPCIRCUIT IS HIGHLY RECOMMENDED.
- 2 -
Page 4
Feature Description
• WineMate split cooling system is designed and used to provide a stable
temperature between 52~62 °F for suitable space at a normal environment.
• The refrigerated space will maintain humidity of 50~70% RH even when the environment becomes dry and humid.
• These temperatures and humilities are optimized for long term storage of wine, fur and tobacco.
• The condensing unit is located away from the wine cellar or other refrigerated enclosure as far as 50 feet, which will bring you extremely quiet operation.
The dimension (in inches) and capacity are specified as follows:
Model
VINO1500
SS
VINO1900
SS
Capacity
(Btu/h)
1500 1900
Unit
Cooler
WM15
SFC
WM19
SFC
Cond
Unit
WM15
SCU
WM19
SCU
Refrigerant
R134a R134a
Electrical
Unit Cooler/
Cond Unit
115V 60HZ, .7A/ 115V 60HZ 3.1A
115V 60HZ 2.2A/
115V 60HZ 3.1A
Weight (lb)
Unit Cooler/
Cond Unit
15/30 20/30
- 3 -
Condensing Unit
Page 5
WM15SFC Evaporator Unit
- 4 -
VINO19SFC Evaporator Unit
Page 6
Installation Instruction
Federal law requires that WINEMATE split cooling systems be installed by an EPA certified refrigeration technician.
1. Location
• Place the condensing unit in a properly ventilated location. If it is not, heat exhausted by the condensing unit will build up and the cooling system will not operate properly.
• Leave minimum 3 feet clearance between the exhaust side and the wall.
• Leave minimum 1 foot clearance for the fresh air supply side.
• Condensing unit should be elevated to avoid possible flooding and shaded
from direct sun. It should not be exposed to temperatures higher than 125
°F or lower than 20 °F.
• Air flow from the unit cooler should be unobstructed for at least 1 foot.
2. Refrigeration Installation
Model Liquid Line Diameter
(inch), recommended
VINO1500SS 1/4 3/8 VINO1900SS 1/4 3/8
WINEMATE split system is shipped as components and is ready for use only after a certified refrigeration technician has properly installed and tested the system. Proper installation is critical. WINEMATE can only warrant the quality of the components. The installation and proper operation of the system must be warranted by the installer. Installation of the system must be done in accordance with all state and local building codes.
Suction Line Diameter
(inch), recommended
- 5 -
Page 7
The condensing unit and unit cooler are connected by a liquid line and an insulated suction line that are supplied by the installer. These lines must be properly sized for the distance between the two units. After the units and the lines are installed, the system must be pressure tested. If no leaks are found, evacuate and charge system with R134A. Refrigerant amount will vary depending on the length of line set.
3. Electrical Wiring
• We strongly recommend against the use of an extension cord. However, if you still select to use an extension cord, it is absolutely necessary that it is a UL LISTED 3-wire grounding type appliance extension cord. The marked rating of the extension cord should be 115 V, 15 A. or equivalent and not greater than 15ft in length.
VINO1500&1900SS Electrical Wiring Diagram
- 6 -
Page 8
Use & Temperature Control
1. Temperature Setting
• Set the temperature at 55 °F for the optimum aging of wine
• On initial start-up, the time required to reach the desired temperature
will vary, depending on the quantity of bottles, temperature setting and surrounding temperature.
• Allow 24 hours to stabilize the temperature for each new temperature setting operation
2. Use of the thermostat
• Turn clockwise to decrease temperature.
• Turn counter clockwise to increase temperature.
- 7 -
Page 9
Care Guide
In general, always unplug system or disconnect power while doing care.
1. Coil Cleaning
• Clean the condenser coil regularly. Coil may need to be cleaned at
least every 6 months.
• Unplug the system or disconnect power.
• Use a vacuum cleaner with an extended attachment to clean the coil
when it is dusty or dirty.
• Plug cooling system or reconnect power.
2. Moisture Removing
• Remove the extra condensate if it is accumulated in the wine cellar at
high ambient temperature and humidity.
- 8 -
Page 10
Troubleshooting
This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration service person, not is it comprehensive
Troubleshooting Chart
Complaint Possible Causes Response
1. Unit not running
a. Power cord unplugged
b. No power to unit c. Temperature setting high d. Low voltage. e. Incorrect or loose wirings. f. Defrost light blinking g. Running light blinking
2. Compressor stopping and starting but short running time
a. Incorrect temperature setting
b. Incorrect voltage c. Failed thermistor
d. Failed components e. Improper condenser airflow
f. Dirty condenser g. Overcharge of refrigerant h. Discharge or suction pressure too
high
3. Fan motor running but compressor not running
a. Incorrect power supply b. Incorrect or loose wirings c. Failed components
d. Liquid refrigerant in the compressor
4. Compressor running but fan not running
a. Fan blade bond b. Incorrect or loose wirings c. Failed motors
5. No cooling but compressor and fan running
a. Evaporator airflow restriction b. Refrigerant leakage c. Refrigeration system restriction
6. Temperature too high or unit running too long
a. Improper evaporator or condenser
airflow b. Dirty Condenser c. Iced evaporator d. Malfunctioning fans e. Improper seals f. Improper area to be cooled.
a. Check for power cord plug b. Check power at receptacle & fuses c. Lower temperature setting d. Contact an authorized electrician e. Check all wirings and connections f. Under defrost g. Call service for failed components
a. Set 55 to 60 b. Check for voltage c. Check thermistor by placing it in ice
water and measuring resistance
d. Check compressor windings, start
relay and overload protector. e. Check for condenser fan f. Clean condenser g. Call service for removing refrigerant h. Call service for OEM information
a. Check for proper voltage b. Check all wirings and connections c. Check start relay, start capacitor,
overload protector, compressor. d. Call service for OEM information.
a. Check for proper clearance b. Check all wirings c. Call service for checking open or
shorted windings
a. Check for airflow through evaporator b. Check for loss of refrigerant c. Call service for checking restrictions
a. Check for air restrictions b. Clean condenser
c. Defrost and reset temperature d. Check for both fans e. Check for gasket and door opening f. Check for excessive load incorrect
installation
°F
- 9 -
Page 11
g. Low voltage h. Operating 60 Hz unit at 50Hz i. Sealed system problem
j. Undercharge or overcharge
7. House circuit tripping
a. Incorrect fuse or breaker b. Incorrect wirings c. Failed components
8. Noisy operation
a. Mounting area not firm b. Loose parts
c. Compressor overloaded due to high
ambient temperatures or airflow restriction
d. Malfunctioning components
g. Check power supply h. Use proper 60 Hz i. Call service for checking loss of
refrigerant or restrictions j. Call service to add or remove
refrigerant
a. Check for proper fuse or breaker b. Check for wirings and connections c. Call service
a. Add support to improve installation b. Check fan blades, bearings, cabinet
washers, tubing contact and loose
screws. c. Check for airflow blockage
d. Call service for checking Internal
loose, inadequate lubrication and
incorrect wirings
- 10 -
Page 12
Customer Support
If you still have problems, please contact us at:
Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: [email protected]
- 11 -
Page 13
Warranty
Thank you for choosing a Vinotemp wine cellar.
Please enter the complete model and serial numbers in the space provided:
Model_________________________________________________________ Serial No.______________________________________________________
Attach your purchase receipt to this owner’s manual.
1. Limited Warranty
VINOTEMP warrants its products, parts only, to be free from defects due to workmanship or materials under normal use and service for twelve months after the initial sale. If the product is defective due to workmanship or materials, is removed within twelve months of the initial sale and is returned to VINOTEMP, in the original shipping carton, shipping prepaid, VINOTEMP will at its option, repair or replace the product free of charge.
This warranty constitutes the entire warranty of the VINOTEMP with respect to its products and is in lieu of all other warranties, express or implied, including any of fitness for a particular purpose. In no event shall VINOTEMP be responsible for any consequential damages what is so ever. Any modification of VINOTEMP products shall void this warranty.
Service under Warranty
This service is provided to customers within the continental UNITED STATES only. VINOTEMP cooling units are warranted to produce the stated number of BTU/H. While every effort has been made to provide accurate guidelines, VINOTEMP can not warranty its units to cool a particular enclosure.
In case of failure, VINOTEMP cooling units must be repaired by the factory or its authorized agent. Repairs or modifications made by anyone else will void the warranty.
Should a VINOTEMP cooling unit fail, contact the dealer for instructions. Do not return the unit to the factory without authorization from VINOTEMP. If the unit requires repair, re-pack it in the original shipping carton and return it to the factory, shipping prepaid. VINOTEMP will not accept COD shipments. If the unit is determined to be faulty and is within the twelve month warranty period
- 12 -
Page 14
VINOTEMP will, at its discretion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect.
2. Limitation of Implied Warranty VINOTEMP’S SOLE LIABILITY FOR ANY DEFECTIVE PRODUCT IS LIMITED
TO, AT OUR OPTION, REPAIRING OR REPLACING OF UNIT. VINOTEMP SHALL NOT BE LIABLE FOR:
DAMAGE TO OTHER PROPERTY CAUSED BY ANY DEFECTS IN THE UNIT, DAMAGES BASED UPON INCONVENIENCE, LOSS OF USE OF THE UNIT, LOSS OF TIME OR COMMERCIAL LOSS, ANY OUTER DAMAGES, WHETHER INCIDENTAL, CONSEQUENTIAL OR OTHERWISE.
THIS WARRANTY IS EXCLUSIBE AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR INPLIED, INCLUDING BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
While great effort has been made to provide accurate guidelines VINOTEMP cannot warrant its units to properly cool a particular enclosure. Customers are cautioned that enclosure construction, unit location and many other factors can affect the operation and performance of the unit. There for suitability of the unit for a specific enclosure or application must be determined by the customer and cannot be warranted by VINOTEMP.