Vingtor Stentofon ICX-500 Getting Started Manual

ICX-500 Getting Started Guide
This document serves as a basic getting started guide for the ICX-500 Intelligent Communication Gateway. Zenitel takes no responsibility for damages caused by improper or inadequate mounting. The ICX-500 product
package comprises the following components:
Item Name
Description
1002000100
ICX-500
Intelligent Communication Gateway
1002500010
IA-RS1
Rack Shelf for ICX-500
1002500020
IA-MB1
Mounting Bracket for ICX-500
1002510000
IPS-AC1
PSU, Input 85-264 VAC, Output 48 VDC, DIN-Rail

1 ICX-500 Connections

Ethernet
Eth0 / Eth1
For initial network connection to ICX-500, use Eth0: Default IP: 169.254.1.5 User name: admin Password: alphaadmin ICX-500 configuration is done using AlphaPro and ICXweb. For detailed configuration guidelines please visit https://wiki.zenitel.com
Power
24-48VDC
ICX-500 shall be powered from a DC power supply with nominal voltage 24VDC or 48VDC. In order to comply with UL safety requirements, ICX-500 has to be powered by a Limited Power Source (LPS) or PS2 (based on IEC/UL 62368-1 definition) or NEC Class 2 source of supply, with maximum power of 100W. Zenitel's PSU IPS-AC1 (1002510000) meets this criterion.
RS232
RJ45
ICX-500 RS232 port is the RJ45 part of the dual connector RS232/USB
USB
USB A USB micro-B
ICX-500 features one USB A and one USB micro-B connector
Fault Relay
3-pole Terminal Block
Fault Relay is used to indicate system status together with Fault LED. The Fault Relay port can be connected to a logical input of a third-party external system and is not carrying any current/voltage.
SD Card
Micro SD Card
Used for external storage or system recovery (Behind protection lid)
Factory Default Button
Tact Switch
Used for resetting ICX-500 to factory settings (Behind protection lid)

2 Wall/Shelf Mounting of the ICX-500

Using the IA-MB1 Mounting Bracket, the ICX-500 can be mounted on any flat surface such as a wall or shelf. The following procedure is for a mounting on a wall as an example.
1. Mount the bracket to the wall using the 3 screws provided.
2. Slide the 4 mounting clips into the side walls of the bracket
3. Slide the ICX-500 unit into the bracket
To have logo and connection annotations in the correct viewing orientation, you may slide the unit either top or bottom up into the bracket depending on whether it is mounted on a wall or shelf.

3 Rack Mounting of the ICX-500

Using the IA-RS1 Rack Shelf, two ICX-500 units can be mounted side by side in a 19” 1HU rack.
1. Slide the 4 mounting clips into the side walls of the rack shelf.
2. Slide the ICX-500 unit into the rack shelf.
3. Use the 2 countersunk type M4x8 screws to secure the unit to the rack shelf via the 2 diagonally positioned securing holes.
The securing holes can also be used to mount the unit to a shelf other than the IA-RS1. Note that the maximum insertion depth is 6 mm.
The ICX-500 is intended for use in restricted access areas for trained service personnel and/or
operators, and is not to be installed in locations where children are likely to be present.
The WEEE Directive does not legislate that Zenitel, as a ‘producer’, shall collect ‘end of life’ WEEE.
This ‘end of life’ WEEE should be recycled appropriately by the owner who should use proper treatment and
recycling measures. It should not be disposed to landfill.
Many electrical items that we throw away can be repaired or recycled. Recycling items helps to save our natural finite resources and also reduces the environmental and health risks associated with sending electrical goods to landfill.
Under the WEEE Regulations, all new electrical goods should now be marked with the crossed-out wheeled bin symbol shown.
Goods are marked with this symbol to show that they were produced after August 13, 2005, and should be disposed of separately from normal household waste so that they can be recycled.
A100K11931
DOC NO.
www.zenitel.com
cs@zenitel.com
Loading...