Vingtor CTB-10 W, CTB-10 V01, CTB-20W, CTB-20W V01, VMT-603 Installation & User Manual

...
INSTALLATION & USER MANUAL
CTB-100V
Command Talk Back & Public Address System
A100K10864
Installation & User Manual System CTB-100V
Table of Contents
1. GENERAL...................................................................................................................................................................... 1
1.1 Purpose of this manual ........................................................................................................................................................1
1.2. Related documents ...............................................................................................................................................................1
1.3. Publication log ......................................................................................................................................................................1
1.4. Requirements........................................................................................................................................................................1
1. SYSTEM OVERVIEW.................................................................................................................................................... 2
2.1. Introduction........................................................................................................................................................2
2.2. Features .................................................................................................................................................................................2
2.2. Optional Equipment.............................................................................................................................................................3
2.4. Functions & User Facilities. ................................................................................................................................................4
2.4.1 General..................................................................................................................................................................................4
2.4.2 Line selection / Single call....................................................................................................................................................4
2.4.3 Signal and extra signal device for substations...................................................................................................................4
2.4.4 Group call..............................................................................................................................................................................4
2.4.5 All call....................................................................................................................................................................................5
2.4.6 Calls from and between Operation panels.........................................................................................................................5
2.4.7 Call from substations ...........................................................................................................................................................5
2.4.8 Parallel communication.......................................................................................................................................................6
2.4.9 AUX function........................................................................................................................................................................6
2.4.10 Audio from external audio to All........................................................................................................................................6
2.4.11 Operation of external Public address system. ...................................................................................................................7
2.4.12 Emergency Public address operation.................................................................................................................................7
2.4.13 Hands free operation............................................................................................................................................................8
2.4.14 Privacy functions ubstation STB-1.....................................................................................................................................8
2.4.15 Two-way voice communication, Nautical Safety...............................................................................................................8
2.4.16 Monitor loudspeaker............................................................................................................................................................9
2.4.17 External loudspeaker...........................................................................................................................................................9
2.4.18 Dimmer of call light..............................................................................................................................................................9
2.4.19 Volume adjustment ..............................................................................................................................................................9
2.4.20 Powersupply SPS-4 (Option)...............................................................................................................................................9
3. INSTALLATION AND CONFIGURATION PROCEDURES......................................................................................... 10
3.1 General ................................................................................................................................................................................10
3.2 Mounting & Terminal configuration. ..............................................................................................................................10
3.2.1 Central unit CU-100 & CU-200........................................................................................................................................10
3.2.2 Operation panel CTB-10 & 20 ..........................................................................................................................................12
3.2.3 CTB-10W / V01, CTB-20W / V01.....................................................................................................................................12
3.2.4 Identification sign plate CTB-panels................................................................................................................................12
3.2.5 Substations and other equipment. ....................................................................................................................................12
3.2.6 Identification sign plate substation...................................................................................................................................12
3.3 Cable requirements............................................................................................................................................................12
3.4 Power supply requirements...............................................................................................................................................13
3.5 Set priority in CU-100 & CU-200.....................................................................................................................................13
3.6 Set receive-call from substation. .......................................................................................................................................13
3.7 Set public address zones SPA............................................................................................................................................13
3.8 Volume and signal adjustment..........................................................................................................................................14
3.8.1 Substations ..........................................................................................................................................................................14
3.8.2 Auxiliary and Public address............................................................................................................................................14
3.8.3 Call signal............................................................................................................................................................................14
3.9 Dimmer on / off in Operation panel .................................................................................................................................15
3.10 Substation STB-1................................................................................................................................................................15
3.11 Substation STB-3................................................................................................................................................................15
3.12 Substation STB-5................................................................................................................................................................15
3.13 Installation for C500 Nautical Safety...............................................................................................................................15
4. USER INSTRUCTIONS...............................................................................................................................................16
4.1 Operation from the operation panel.................................................................................................................................16
4.1.1 Make a call to an substation..............................................................................................................................................18
4.1.2 Make a call to group of substations..................................................................................................................................19
4.1.3 All Call.................................................................................................................................................................................20
4.1.4 Handsfree operation...........................................................................................................................................................21
4.1.5 Give signal to substations with extra signal device.........................................................................................................21
4.1.6 Receive a call from an substation.....................................................................................................................................22
4.1.7 Receive a call from two or more substations...................................................................................................................23
4.1.8 AUX function......................................................................................................................................................................24
4.1.9 Audio from external audio to All......................................................................................................................................25
4.1.10 Public Address Operation of external system .................................................................................................................26
4.1.11 Emergency Public Address Operation.............................................................................................................................27
4.1.12 Volume .................................................................................................................................................................................29
4.1.13 Dimming of call light..........................................................................................................................................................29
4.2 Parallel communication.....................................................................................................................................................30
4.2.1 Operation.............................................................................................................................................................................31
4.3 Operation from substations...............................................................................................................................................32
1. GENERAL
1.1 Purpose of this manual
This manual supplies an engineer with the information required to install and commissioning a CTB-100V system and the end-user with all necessary instructions for operating the CTB_100V system. Refer to Service Manual for maintenance and repair. The manual can also be used as a guideline for design and planning of the sy stem.
1.2. Related documents
The following related documents are available: Single line and connections drawing in Autocad format. Declaration of conformity doc.no.DC CTB 20040601 SH
1.3. Publication log
Product / Ver.no.: CTB Ver.07
Title: CTB-100V Installation & User Manual Doc.no. / Rev. CTB-100V_iu Author: S.E.Nilsen Verified By:
Revision Issued Changes / Comments 00 2001.09.06 First issue, User & Technical Manual
Draft I 2005.10.06 Second release, name changed to Installation & user
manual, CTB Ver.07 for approval
01 2006.06.08 Third release to meet requirement from Det Norske Veritas
(DNV)
01.1 2007.01.22 Replaced drawing CTB_cc3 Rev.04 with Rev.05 And dwg.CTB-100_cc2 Rev.04 with Rev.05
A100K10864 2008.08.26 New front and back p ag e. Doc.no. CTB-100_iu Rev. 01.1
is replaced by this document no.
Zenitel Norway AS and its subsidiaries assume no responsibilities for any errors that may appear in this publication, or for damages arising from the information in it. No information in this publication should be regarded as a warranty made by Zenitel Norway AS.
The information in this publication may be updated or changed without notice. Product names mentioned in this publication may be trademarks, they are used only for identification.
Zenitel Norway AS, August 2010
1.4. Requirements
The CTB system and its components have been tested according to following regulations:
IEC 60533: Second edition, 1999; «Electrical and electronic installation in ships – Electromagnetic
compatibility».
IEC 60945: Fourth edition, 2002; «Maritime navigation and radio communication equipment and
systems - General requirements - Methods of testing and required test results».
IACS E10: Corr. 1 July 2003; «Unified environmental test specification – Testing procedure for electric
control and monitoring , safety and protect i o n, o n bo ard computer based systems and peripherals, loading instruments, internal communication and other electrical equipment as considered appropriate».
Installation & User Manual System CTB-100V
ii
4.3.1 Operation from STB-1.......................................................................................................................................................35
4.3.2 Operation from STB-2.......................................................................................................................................................35
4.3.3 Operation from STB-3.......................................................................................................................................................36
4.3.4 Operation from STB-5.......................................................................................................................................................37
4.3.5 Operation from STB-5GN.................................................................................................................................................38
4.3.6 Operation from HE-112M / HE-112MT..........................................................................................................................38
4.3.7 Operation from VH-10M / VH-10M-T............................................................................................................................39
4.3.8 Operation from VHM-10 / VHM-10-T............................................................................................................................39
4.3.9 Operation from NEBB-42EX / EX Loudspeaker............................................................................................................40
5. COMMISSIONING.......................................................................................................................................................41
5.1 General ................................................................................................................................................................................41
5.2 Mechanical Inspection .......................................................................................................................................................41
5.3 Cable Inspection .................................................................................................................................................................41
5.4 Check Configurations. .......................................................................................................................................................41
5.5 C500 Nautical Safety..........................................................................................................................................................41
5.6 Starting up the system........................................................................................................................................................42
5.8 Trouble shooting.................................................................................................................................................................43
6. INSTALLATION DRAWINGS AND DATASHEET ....................................................................................................... 46
6.1 Installation drawings..........................................................................................................................................................46
6.2 Datasheets............................................................................................................................................................................46
Installation & User Manual System CTB-100V
2
1. SYSTEM OVERVIEW
2.1. Introduction
The Command Talk Back System CTB-100V is specially designed for important communication for use in rough marine environment. Available in 10 and 20 line version. The CTB system consist of a central unit CU-100 or CU-200 with up to 4 operation panels for use on bridge console, bridge wings, engine control room etc. and a comprehensive range of substations and field equipment for use indoor, outdoor and noisy areas. The system includes many facilities and can operate together with PA-system to increase functionality and fields of operation.
2.2. Features
10 or 20 line selection 100V line power amplifier.
4 Operation panels Dimmable panel background light
Gooseneck or handheld microphone. Step volume control
Parallel Communication. Output for extra signal device for all substation lines
All call / Group Call facility Output for external loudspeaker
Public Address Operation Input for external microphone.
AUX / Alarm input Dimension panels H:144 x W: 240 x 100
Hands free operation. Power 22 - 32 V DC
Cover requirement for DNV C500 Nautical Safety
Operation panel CTB-20W/V01
Foot-switch
Signal unit
1
EEx de IIC T6 PTB Nr.Ex-87.B.1009
Ui 690V
CEAG
GHG 411
I16A
Substation STB-3 Line 19
100V Ex-loudspeaker Ex-push button box
Substation STB-5 Line 17
HAS-1
ETC-STB5
Signal unit Signal unit
Substation STB-5GN Line 18
Signal unit
Signal unit
VML-15T
VML-1520
P-MT7
P-66
Substation line 20
P-66
P-66
Signal unit
Signal unit
Central unit CU-200
MB-30G
ETC-1-TB
MB-30G
TC-1-TB
Signal unit
Sub-station STB-1 Line 5
Sub-station STB-1 Line 6
Sub-station STB-1 Line 7
Substation STB-2 Line 11
VML-15T
Substation STB-2 Line 10 `
VML-15
Substation HE-112MT Line 9
Substation HE-112MT Line 8
Operation panel CTB-20
Operation panel CTB-20W/V0
1
Line 2
Line 3
Line 1
Operation panel CTB-20
Line 4
10m cable
Substation VHM-10MT Line 12
Substation VH-10MT Line 13
CD-2
VML-15T
HP-8
HP-8
100V Loudspeaker line Line 14
100V Loudspeaker line Line 15
100V Loudspeaker line Line 16
ON OFF
VPA-120
POWER AMPLIFIER
100V POWER AMPLIFIER
DC ok
24V DC OUT
24V DC EMERGENCY
230/115V AC MAIN
POWER SUPPLY
Installation & User Manual System CTB-100V
3
2.2. Optional Equipment
See chapter 6 for further details and datasheet
Central units, operator panels and microphones.
CU-100 Central unit 10 line 24V DC CU-200 Central unit 20 line 24V DC CTB-10 Operation panel, 10 lines CTB-20 Operation panel, 20 lines CTB-10W / V01 Operation panel, 10 lines, weatherproof. Bulkhead mounting only.
Including external loudspeaker HP-8.
CTB-20W / V01 Operation panel, 20 lines, weatherproof. Bulkhead mounting only.
Including external loudspeaker HP-8.
HP-8 Horn loudspeaker, part of CTB-10W V01 and CTB-20W V01
VMT-603 All Call statio n WT, for wall mounting
MB-30G
Gooseneck Microphone with plug for CTB-10 & 20
ETC-1-TB Hand microphone with curled cord and plug for CTB-10 & 20 P-66 Hand microphone with curled cord and plug, WP P-66/10 Hand microphone with 10mtr. Cable and plug, WP
AW8121 Power amplifier 120W / 100V 220V AC/24V DC AW8241 Power amplifier 240W / 100V 220V AC/24V DC P-8501 Power amplifier 500W / 100V 220V AC/24V DC RS-3D Cabinet for power amplifier
Substations and other equipment
STB-1 Substation indoor wall mounted with call and answer button. STB-2 Call box WP wall mounted for use together with VML-1520. STB-3 WP Combined call-plug box w/relay unit wall mount for headset, loudspeaker and
extra signal device, PMT-7 Portable headset w/10mtr. Cable and plug for STB-3 VML-1520 Horn loudspeaker 15W 20ohm IP-65 STB-5 Flush mounted substation w/relay, for mic. or handset STB-5GN Flush mounted substation w/relay, and gooseneck microphone HAS-1 Handset for STB-5 ETC-STB5 Hand microphone with curled cord and plug for STB-5. VH-10M Portable deck loudspeaker with callbox and 10M cable and plug.
VH-10M-T Portable deck loudspeaker 100V w/ callbox and 10M cable and plug
CD-2 Plugbox for VH-10M VHM-10 Special deck unit with hand microphone mounted in cabinet.
VH-10M-T Portable deck loudspeaker 100V w/ callbox and 10M cable and plug
HE-112M Outdoor loudspeaker with call button WP IP-66
HE-112M-T Outdoor loudspeaker 100V with call button WP IP-66
NEBB-42EX Call box, Ex-approved VML-15T Horn loudspeaker 15W 100V IP-65
Bridgewing equipment, microphones
STB-6 Flush mounted substation for handmic. STB-6GN Flush mounted substation w/gooseneck mic. SB-4 WP Plug box for portable microphone, headset and loudspeaker, wall mounted. P-66 Hand microphone with curled cord and plug, WP P-66/10 Hand microphone with 10mtr. Cable and plug, WP
Additional equipment
WBOKS Wall mounted box for CTB-10/20 STBOKS5 Wall mounted box for STB-5 and STB-5GN STBOKS Wall mounted box for STB-6 ad STB-6GN VML-1520 Horn loudspeaker 15W 20ohm IP-66 SPS-4 Power supply 115/230V AC 24V DC w/ automatic switchover relay. BLK5-24 Flash beacon 24V AC/DC 5 Joule IP65 EHS-24 Rotary light 24V DC IP54 A-100 Electronic alarm horn 24V DC – IP55 – 100dB
Installation & User Manual System CTB-100V
4
2.4. Functions & User Facilities.
2.4.1 General
The CTB-100 system consist of 1 central unit CU-100 or Cu-200, 1 to 4 operation panels, 1 to 20 substations or loudspeakers and one 100V power amplifier. On system with more than 1 operation panel, each panel take one substation line. The system have one speech channel and operation from one operation panel will be indicated in other operation panels. The operation panels follows a priority hierarchy 1 to 4, that means operation panels with higher priority can override operation panels with lower priority. Operation panel CTB-10 & CTB-10W_V01 with 10 line selection, CTB-20 & CTB-20W_V01 with 20 line selection. CTB-20 used in the presentation. |
2.4.2 Line selection / Single call
1 - 10 (20) substations or other operation panels can be selected from any operation panel by pressing respective line button. Indicated with steady green light in LED. (Light emitting diode)
2.4.3 Signal and extra signal device for substations.
A call signal can be given to selected station. The function will also activate an 24VDC max 50mA to substation with relay or direct connected external signal device
2.4.4 Group call
Group of substations or other operati o n panels can be selected by pressing respective number of line buttons. Indicated with steady green LED.
Installation & User Manual System CTB-100V
5
2.4.5 All call
20
11
4
10
3
2
All call message can be distributed from any operation panel to all substations and other operation panels. All call message will also activate Public Address System if connected. Indicated with steady green LED in the «ALL» push button.
2.4.6 Calls from and between Operation panels.
Up to 4 operation panels can be connected. Calls can be made from any operation panel to substations. And calls can be made from any operation panel to another by pressing respective line button. In this stage the called operation panel act as a substation. Calls from one operation panel will be indicated in all operation panels.
Priority:
One operation panel is always decided to be a master station with highest priority. The priority follows a hierarchy 1 to 4, with operation panel 1 as highest priority . It is a standard setting. With dip-switches in the central unit the priority can be changed. (See chapter 3.5)
Type of panels:
CTB-10 Operation panel 10 line selection, indoo r use. CTB-10W/V01 Operation panel 10 line selection, WP. CTB-20 Operation panel 20 line selection, indoo r use. CTB-20W/V01 Operation panel 20 line selection, WP.
2.4.7 Call from substations
Calls from a substation can be received in all operation panels. Indicated with flashing green light in LED in respective line.
Preferred operation panels can be set to receive a call with an acoustic signal in addition.
Installation & User Manual System CTB-100V
6
2.4.8 Parallel communication
P T
T S
W I
T C
H
P T T
S W
I T C
H
Function with operation from parallel microphone / loudspeaker located on bridge wings, or other locations where parallel microphone / loudspeaker needed.
Note! Line selection have to be set up from the operation panel.
2.4.9 AUX function
AUX
External entertainment, message or alarm can be distributed trough the CTB system by using push button switch “AUX” together with line selection switches. 0dB signal from the external system connected to the CTB system will be addressed to selected substations.
The TALK button on operation panels or PTT butt o n on ha nd microphone will override the AUX to giving a all call message.
External system can be:
VHF radio System
Entertainment system.
2.4.10 Audio from external audio to All
20
11
4
10
3
2
Alarm (or any audio) from external system can be distributed trough the CTB system. An potentional free contact and 0dB signal from the external system activate the CTB and the message will be addressed to all substations and operation panels.
The talk button on the operation panel or PTT button on hand microphone will override the external audio. Normal talk back functions can not be used in this mode.
External system can be:
Alarm system.
External Public Address System
Note! Only the operator of the external system can switch of the external audio.
Installation & User Manual System CTB-100V
7
2.4.11 Operation of external Public address system.
I
0
SERIES POWER AMPLIFIER
The four last line push buttons on the operation panels can be set to access 1 to 4 public address zones of external system.
CTB-10 & CTB-10W_V01: Push button marked 7-8-9- 10 CTB-20 & CTB-20W_V01: Push button marked 17-18-19-20
Note! Other operation panels with higher priority can override the PA­message.
2.4.12 Emergency Public address operation.
Central unit CU-200
ON OFF
VPA-120
POWER AMPLIFIER
100V POWER AMPLIFIER
In order to comply with PA-requirements, two PA call stations are required: The CTB-100V system are designed for use with up to four operation panels that can be used as Emergency call stati ons. I n ad di t i on o ne or more All call station (Ex. Lifeboat stations) can be used as Emergency call stations. Following functions:
Mute of the External Alarm System (General / Fire Alarm)
Operation panel with 1
st
priority, normally bridge, can override other operation panels.
Type of Operation panels/ Emergency call stations:
CTB-10 Operation panel 10 line selection, in do o r use. Hand or gooseneck microphone.
CTB-10W/V01 Operation panel 10 li ne selection, WP. Handmicrophone onl y.
CTB-20 Operation panel 20 line selection, in do o r use. Hand or gooseneck microphone.
CTB-20W/V01 Operation panel 20 li ne selection, WP. Handmicrophone onl y.
VMT-603 All call station WT with handmicrophone.
Installation & User Manual System CTB-100V
8
2.4.13 Hands free operation
Foot-switch
Parallel station STB-6GN
Foot-switch
Foot-switch
Handsfree operation of operation panel or parallel station.
Option 1
Operation panel with gooseneck microphone MB-30G and footswitch U2410.
Option 2
Parallel station type STB-6GN with gooseneck microphone MB-30G and footswitch U2410.
2.4.14 Privacy functions ubstation STB-1
Substation STB-1 is designed for indoor use; cabins, mess room etc., and prepared with privacy function. It means ; Listening is not possible in the central unit from STB-1. After a call is set up from the central unit, the operator of STB-1 have to use TALK button for communicate with the central unit. (STB-1 can also be set to normal talk back function, see pos.3.10)
2.4.15 Two-way voice communication, Nautical Safety
1
CENTRAL UNIT CU
JUNCTION BOX
Configuration to meet requirement for hands free two-way voice communication according to DNV rules for Nautical Safety.
Following locations has operation panels with all call:
- Bridge wings
- Wheelhouse
- Engine control room
Following locations has substations and additional all call stations:
- Forecastle deck (fore mooring station)
- Aft mooring station
- Midship mooring station
- Steering gear room
- Cargo control room
Installation & User Manual System CTB-100V
9
2.4.16 Monitor loudspeaker.
The monitor loudspeaker is located in front of the operation panels CTB-10 & CTB-20. CTB-10W_V01 & CTB-20W_V01 with external loudspeaker only. For distribution of audio; message or alarm signals.
2.4.17 External loudspeaker.
External loudspeaker for improved and higher sound level can be used. Connected in parallel with the monitor loudspeaker in CTB-10 and CTB-20. Located nearby the operation panel.
Note! CTB-10W_V01 & CTB-20W_V01 operation panels only equipped with external loudspeaker.
2.4.18 Dimmer of call light.
Intensity of the push button light can be adjusted by pressing DIM button. Switch between two steps max.and 1/3. Default is set to max. Dimmer can be set to on /off by dip-switch.
2.4.19 Volume adjustment
By pressing + or - buttons repeatedly, you can increase or decrease the listening volume in the central unit This will also affect the volume for an external speaker connected to the panel.
2.4.20 Powersupply SPS-4 (Option)
DC ok
24V DC OU
T
24V DC EMERGENCY
230/115V AC MAIN
POWER SUPPLY
The power supply SPS-4 is designed with power failure contact and automatic switch over relay. It means indication and automatic switch over to 24V DC emergency power supply when mains supply or power module fails.
Installation & User Manual System CTB-100V
10
3. INSTALLATION AND CONFIGURATION PROCEDURES
3.1 General
For proper installation and operation of the CTB-system we recommend to read this section thoroughly together with installation drawings in chapter 6.
Make sure that all mounting and cabling are correct before switching on the system
3.2 Mounting & Terminal configuration.
3.2.1 Central unit CU-100 & CU-200
The central unit is the basis of a system. It should be bulkhead mounted in a normal and ventilated indoor environment with a temperature of max. 55
0
C. See drawing CU_dd for mounting details.
Note ! Make sure that it is sufficient space for cables and maintenance.
It is equipped with pluggable screw terminals for cables max.2,5mm
2
Fig. CU-100 See drawing CU-100_lo for further details.
Terminal block X1-X4 Connection of operation panels.
Terminal block X5 Output to the PA-system. Terminal block X6 AUX and PA input. Terminal block X7 Power supply.
Terminal block X8 1-10 for Connection Substations.
Terminal no.3 – 4 24V DC to extra signal device. Terminal no.5 is ground point for each substation screen.
Terminal block C1-C10 for Connection Substations. Terminal no.1 – 2 substation line low impedance Terminal no.3 – 4 substation line 100V
Terminal block C25 MUTE for external alarm system
Other terminal blocks for internal use.
Installation & User Manual System CTB-100V
11
Fig. Additional PCB for CU-200 See drawing CU-200_lo for further details.
Terminal block X8 11-20 for Connection Substations. Terminal no.3 – 4 24V DC to extra signal device. Terminal no.5 is ground point for each substation screen.
Terminal block C1-C20 for Connection Substations. Terminal no.1 – 2 substation line low impedance Terminal no.3 – 4 substation line 100V
Terminal block C25 MUTE for external alarm system
Other terminal blocks for internal use.
Installation & User Manual System CTB-100V
12
3.2.2 Operation panel CTB-10 & 20
The operation panels indoor can be flush or bulkhead mounted in a normal and ventilated indoor environment with a temperature of 0 - 55
0
C. See drawing CTB-1020_dd1 for mounting details.
Note ! Make sure that it is sufficient space for cables and maintenance.
It is equipped with 2x cable gland PG-16 and plugable screw terminals for cables max.2,5mm
2
See drawing CTB-1020_lo for terminal and
Terminal block X1: For connection to the central unit. Terminal block X2: Not in use Terminal block X3 For connection to external loudspeaker, microphone and parallel microphone. Terminal block X4 Potentional free contact for extra signal unit. Terminal block SPEAKER 1-2 for external loudspeaker HP-8 (CTB-10W / V01, CTB-20W / V01)
3.2.3 CTB-10W / V01, CTB-20W / V01
This weather proof operation panels IP-66 is for bulkhead mounting only. Including external loudspeaker HP-8 Ref. drawing CTB-1020W_dd for mounting details and datasheet for HP-8. It is equipped with 2x cable gland PG-16 and plugable screw terminals for cables max.2,5mm
2
Ref. drawing CTB-1020_lo for lay out terminals drawing CTB-102 0W_dd for mounting details and datasheet for HP-8. Note ! Make sure that it is sufficient space for cables and maintenance.
3.2.4 Identification sign plate CTB-panels
A sign plate with directory / substation number for all substations has to be placed close to the CTB-panels.
3.2.5 Substations and other equipment.
Ref. datasheets for dimension, cut out and mounting. Note ! Make sure that it is sufficient space for cables and maintenance.
3.2.6 Identification sign plate substation
A sign plate with each substation number has to be placed on or close to each substation.
3.3 Cable requirements
All signal cables have to be approved ship-cable of type twisted pair with outer braided copper screen. See cable connection drawings in chapter 6 for further details. The screens must be interconnected in junction boxes and grounded in the central unit only. Terminal block X8 1-20 terminal no.5 is ground point for each substation screen Terminal block X1,2,3,4 / no.11 is ground poi nt fo r eac h o perat ion panel. Power cable has to be approved ship cable min. 3 x 1,5mm
2
Note! The central unit has to be connected to the vessels central ground. Proper grounding is essential for reliable operation.
Installation & User Manual System CTB-100V
13
3.4 Power supply requirements
24VDC -10% + 33% (21,6 – 32VDC) Current consumption max. 4A System power supply should be wired and fused independently from other systems.
1. 24V DC from ships 24V DC system.
2. 24V DC from power supply SPS-4 230V AC /.24V DC with automatic switch to 24V DC emergency power supply.
3.5 Set priority in CU-100 & CU-200
Ref. drawing CU-100_lo and CU-200_lo
DIP-switches in the central unit.
Priority is set by 4 dip-switches, corresponding to each operation panel 1 to 4. If all 4 dip-switches is set to off, the priority follows a hierarchy 1 to 4 giving panel 1 highest priority. This is standard factory setting. What ever DIP-switch set to 1 will have highest priority, still following the hierarchy as explained above. Example: If DIP switch 4 is set to ON, priority will be 4-1-2-3. If both DIP switch 1 and 4 is set to ON, priority will be 1-4-2-3.
3.6 Set receive-call from substation.
Ref. drawing CU-100_lo and CU-200_lo
Receive call from substation is set by 4 DIP-switches, corresponding to each operation panel 1 to 4. DIP-switch set to ON, permits the panels to receive a call from substations. DIP-switch 1 is set to ON for panel 1 is standard factory setting. Example: If both DIP switch 1 and 4 is set to ON, both panel 1 and 4 will receive a call.
3.7 Set public address zones SPA
Ref. drawing CU-100_lo and CU-200_l
Four line push buttons on the operation panel can be set to access 1 up to 4 public address zones.
PA is set by 4 DIP-switches corresponding to each push button. DIP-switch marked 7-10 for line 7 – 10 (CTB-10 & CTB-10W_V01) DIP-switch marked 17-20 for l i ne 17 – 20 (CTB-20 & CTB-20W_V01) Standard factory setting is to OFF.
Installation & User Manual System CTB-100V
14
3.8 Volume and signal adjustment.
Ref. drawing CU-10_lo and CU-20_lo for location.
3.8.1 Substations
System volume for substations can be adjusted by separate trim potentiometer for each group of 5 lines. Market “volume setting line 1-5” “6-10” “11-15” “16-20”
System volume is factory adjusted and does not normally require any adjustment.
Volume adjustment for substation line 1 – 5 Trim potentiometer located on mainboard
Volume adjustment for substation line 6 – 10 Trim potentiometer located on mainboard
Volume adjustment for substation line 11 – 15 Trim potentiometer located on additional board CU-20.
Volume adjustment for substation line 16 – 20 Trim potentiometer located on additional board CU-20.
3.8.2 Auxiliary and Public address.
Signal is factory adjusted and does not normally require any adjustment.
Input signal for auxiliary can be adjusted by separate trim potentiometer marked “adj. aux.input signal”. Required signal 0dB (0,775V)
Signal for Public address can be adjusted by separate trim potentiometer marked “adj. pa output signal”. Signal is factory set to 0dB (0,775V) and does not normally require any adjustment.
3.8.3 Call signal
Signal is factory adjusted and does not normally require any adjustment.
Level of Call signal out all lines can be adjusted by trim potentiometer marked “adj. call signal out”
Installation & User Manual System CTB-100V
15
3.9 Dimmer on / off in Operation panel
Ref. drawing CTB-1020_lo
Dimmer can be set to on /off by dip-switch marked “dimmer off”
3.10 Substation STB-1
Default setting is Privacy function, can be set to normal Talk Back Function. Talk Back Function; move the jumper J1 on PCB in STB-1
3.11 Substation STB-3
Default setting is for headset, can be set for microphone. Microphone; move the two jumpers on PCB - STB-3in position M
3.12 Substation STB-5
Default setting is for microphone or handset, loudspeaker can be set to both loudspeaker and microphone. (Re-entrant speaker) Re-entrant speaker; move the jumper J1 on PCB in STB-5.
3.13 Installation for C500 Nautical Safety
Installation has to follow strictly requirement given in following chapter and drawings:
Chapter 2.4.13
Chapter 3.2.4 and 3.2.6
Drawing: Cable connection diagram CTB_cc6
Installation & User Manual System CTB-100V
16
4. USER INSTRUCTIONS
4.1 Operation from the operation panel.
Up to 4 operation panels can be connected. Calls can be made from any operation panel to substations. And calls can be made from any operation panel to another by pressing respective line button. In this stage the called operation panel act as a substation. Calls from one operation panel will be indicated in other operation panels. One operation panel is always decided to be a master station with highest priority and can override operation panels wit h lowe r priority.
Figure 1 Operation panel CTB-10
1
2
34
11
2
34
1
4
4
212
1
10
9
8
7
6
5
Figure 2 Operation panel CTB-20
1
2
34
11
2
34
1
5
6
7
8
9
10
Figure 3 Operation panel CTB-10W_V01
11
13
12
Figure 4 Operation panel CTB-20W_V01
11
12
13
Figure 5 Gooseneck microphone MB-30G
Figure 6 Handheld Microphone with switch ETC-1-TB
PTT SWITCH
Figure 7 Handheld Microphone WP with switch P-66
PTT SWITCH
Figure 8 Footswitch U2410
Installation & User Manual System CTB-100V
17
Figure 1 & 2 CTB-10 & CTB-20
1........Monitor loudspeaker .....For communication and alarm signals.
2........Line Push Buttons ......... Line selection switch with indication light, 1 -10 for CTB-10
.......... ..........................................1 – 20 for CTB-20
3........Green Indication light ... (LED) for each line push button.
4. ......Microphone contact ......For Gooseneck or hand microphone.
5. ......VOLUME - +: ................Increase or decrease of volume in monitor loudspeaker loudspeaker)
6. ......ALL .................................Push button switch with indication light (LED)
7........AUX .................................Push button switch for activating external signal to selected stations.
8. ......DIM .................................Push button switch for adjust intensity of call light in indication light (LED)
9. ......SIGN ............................... Push button switch for signal and activating of extra signal device substations.
10. ....TALK .............................. PTT switch for gooseneck microphone MB-30G
Figure 3 & 4 CTB-10W_V01 & CTB-20W_ V0 1
2-10.. Functions.........................Same as for CTB-10 & CTB-20
11...... External loudspeaker ....For communication and alarm signals. Flush or wall mounting.
.......... ..........................................Monitorloudspeaker not installed.
12...... Microphone contact .......For handheld microphone P-66
13...... Cabinet ........................... WP cabinet, wall mounting only.
Figure 5.......................................Gooseneck microphone MB-30G for CTB-10 & CTB-20.
Figure 6.......................................Handheld microphones ETC-1-TB for CTB-10 & CTB-20.
Figure 7.......................................Handheld microphones P-66 for CTB-10W_V01 & CTB-20W_V01
Figure 8.......................................Footswitch U2410 for handsfree operation of microphone MB-30G
PTT switch = Push To Talk switch LED = Light emitting diode.
Installation & User Manual System CTB-100V
18
4.1.1 Make a call to an substation.
You can select the substation by pressing desired line push button. Steady green LED will indicate activated selection. If desired, the signal button SIGN may be pressed to give a tone signal to selected station. Talk from the operation panel is performed every time TALK button is pressed. The operation panel unit will be in listening mode as soon as a station is selected. When communication is finished, press again the selected station button to switch off. The LED will be switch off to indicate that selected line is turned of.
Operation panel : CTB-10,CTB-20, CTB-10W_V01 or CTB-20W_V01
Press the LINE button, the call is set up. Indicated by steady green LED
Press the SIGN button
A tone signal will be given to selected station as long as the SIGN button is kept pressed. This will also activate extra signal devices, if connected (Se pos.4.1.5)
Operation panel with gooseneck microphone MB-30G
Press the TALK button.
Speak clearly into the microphone. When the TALK button is released the operation panel will be in listening mode, and you will hear the communication from the selected station.
PTT SWITCH
ETC-1-TB
Operation panel with hand microphone ETC-1-TB
Press the PTT SWITCH..
Speak clearly into the microphone. When the PTT SWITCH button is released the operation panel will be in listening mode, and you will hear the communication from the selected station.
PTT SWITCH
Operation panel with hand microphone P-66
Press the PTT SWITCH..
Speak clearly into the microphone. When the PTT SWITCH button is released the operation panel will be in listening mode, and you will hear the communication from the selected station.
Press the LINE button once more to end the call.
The LED will be switch off.
Installation & User Manual System CTB-100V
19
4.1.2 Make a call to group of substations.
You can select group of substations by pressing respective line buttons from one of the four Operation panels. Only the operation panels can switch off and end the call
Press the required LINE buttons, the call is set up. Indicated by steady
green LED in selected buttons.
Press the SIGN button
A tone signal will be given to selected station as long as the SIGN button is kept pressed. This will also activate extra signal devices, if connected (Se pos.4.1.5)
Operation panel with gooseneck microphone MB-30G
Press the TALK button.
Speak clearly into the microphone. When the TALK button is released the operation panel will be in listening mode, and you will hear the communication from the selected stations.
PTT SWITCH
ETC-1-TB
Operation panel with hand microphone ETC-1-TB
Press the PTT SWITCH.
Speak clearly into the microphone. When the PTT SWITCH button is released the operation panel will be in listening mode, and you will hear the communication from the selected station.
PTT SWITCH
Operation panel with hand microphone P-66
Press the PTT SWITCH..
Speak clearly into the microphone. When the PTT SWITCH button is released the operation panel will be in listening mode, and you will hear the communication from the selected stations.
Press all the LINE buttons once more to end the call.
The LED will be switch off.
Installation & User Manual System CTB-100V
20
4.1.3 All Call
The message and signal from the operation panel will be given to all substations, as a one-way message. It will be indicated by steady green LED in the ALL button only. Talk back from substations is closed in this mode.
Press the ALL button, the call is set up. Indicated by steady green LED
in the ALL button.
Press the SIGN button
A tone signal will be given to selected station as long as the SIGN button is kept pressed. This will also activate extra signal devices, if connected (Se pos.4.1.5)
Operation panel with gooseneck microphone MB-30G
Press the TALK button.
Speak clearly into the microphone.
PTT SWITCH
ETC-1-TB
Operation panel with hand microphone ETC-1-TB
Press the PTT SWITCH.
Speak clearly into the microphone.
PTT SWITCH
Operation panel with hand microphone P-66
Press the PTT SWITCH..
Speak clearly into the microphone.
Press the ALL button once more to end the call.
The LED will be switch off.
Installation & User Manual System CTB-100V
21
4.1.4 Handsfree operation
Operation panel with gooseneck microphone MB-30G and footswitch
Press the FOOTSWITCH button .
Speak clearly into the microphone. When the TALK button is released the operation panel will be in listening mode, and you will hear the communication from the selected station.
4.1.5 Give signal to substations with extra signal device.
Substation STB-3, STB-5 and STB-5GN is equipped with relay for activating of extra signal device. Extra signal device can be flashing beacon, rotary light, alarm horn and bells.
Operation panel Substation
Press the SIGN button
A tone signal will be given to selected station as long as the SIGN button is kept pressed:
Indication 1 A tone signal in the substations monitor loudspeaker STB-5 and STB-5GN. or in horn­loudspeaker for STB-3
This will also activate extra signal to substations equipped with these devices:
Indication 2 Signal in flashing beacon, rotary light, alarm horn or bells. (STB-5GN w/ Rotary light in illustration)
Installation & User Manual System CTB-100V
22
4.1.6 Receive a call from an substation.
A call are indicated with flashing green LED in the push button and a beep tone in the monitor loudspeaker or extern loudspeaker. Will also activate extra signal unit if installed. Only the operationpanel can switch off and end the call.
A call is indicated with flashing green LED in for respective line button,
and signal in the monitor loudspeaker. (and in extra signal unit if installed.)
Press the LINE button, the call is set up. Indicated by steady green LED
Operationpanel with gooseneck microphone MB-30G
Press the TALK button.
Speak clearly into the microphone. When the TALK button is released the operationpanel will be in listening mode, and you will hear the communication from the selected station.
PTT SWITCH
ETC-1-TB
Operationpanel with hand microphone ETC-1-TB
Press the PTT SWITCH.
Speak clearly into the microphone. When the PTT SWITCH button is released the operationpanel will be in listening mode, and you will hear the communication from the selected station.
PTT SWITCH
Operationpanel with hand microphone P-66
Press the PTT SWITCH..
Speak clearly into the microphone. When the PTT SWITCH button is released the operationpanel will be in listening mode, and you will hear the communication from the selected station.
Press LINE button once more to end the call.
The LED will be switch off.
Installation & User Manual System CTB-100V
23
4.1.7 Receive a call from two or more substations.
Calls can be received from two or more substations at same time. The operation panel that is set to receive calls can select between calls from substations. Calls are indicated with flashing green LED in the push buttons and a beep tone in the monitor loudspeaker Will also activate extra signal unit if installed. (Only for the first incoming call.) .
Calls are indicated with flashing green LED for respective line button,
and signal in monitor loudspeaker. (And in extra signal unit if installed, Note! only for the first call)
Press the LINE button, the call is set up. Indicated by steady green LED
The the operation panel can select between substation lines and cancel calls by pressing the respective LINE button once more.
Operationpanel with gooseneck microphone MB-30G
Press the TALK button.
Speak clearly into the microphone. When the TALK button is released the operation panel will be in listening mode, and you will hear the communication from the selected station.
PTT SWITCH
ETC-1-TB
Operationpanel with hand microphone ETC-1-TB
Press the PTT SWITCH.
Speak clearly into the microphone. When the PTT SWITCH button is released the operation panel will be in listening mode, and you will hear the communication from the selected station.
PTT SWITCH
Operationpanel with hand microphone P-66
Press the PTT SWITCH..
Speak clearly into the microphone. When the PTT SWITCH button is released the operation panel will be in listening mode, and you will hear the communication from the selected station.
Press the selected LINE buttons once more to end the call.
The LED`s will be switch off.
Installation & User Manual System CTB-100V
24
4.1.8 AUX function
An external signal connected to the AUX input of the system, will be transferred to any selected station or group of stations if the AUX button is selected. (Example: Entertainment and VHF signal.) Other functions with higher priority will override this function.
AUX
Press desired line push buttons
Press the AUX button,
The AUX transferring is set up. Indicated by steady green light.
To override this function with gooseneck microphone
Press the TALK button on the operation panel.
Speak clearly into the microphone. When the TALK button is released the system will be in AUX mode again.
PTT SWITCH
ETC-1-TB
To override this function with hand microphone ETC-1-TB
Press the PTT SWITCH on hand microphone.
Speak clearly into the microphone. When the TALK button is released the system will be in AUX mode again.
PTT SWITCH
To override this function with hand microphone P-66
Press the PTT SWITCH..
Speak clearly into the microphone. When the PTT SWITCH button is released the operation panel will be in AUX mode again.
To end the function
Press line and AUX button once more to end the transferring.
Installation & User Manual System CTB-100V
25
4.1.9 Audio from external audio to All
Alarm (or any audio) from external system can be distributed trough the CTB-100 system. An potentional free contact and 0dB signal from the external system activate the system and the message will be addressed to all substations and operation panels. The talk button on the operation panel or PTT button on hand microphone will override the extern al audio. Normal talk back functions can not be used in this mode.
External system can be:
Alarm system.
20
11
4
10
3
2
Switch on the external audio,
The audio transferring is set up. Indicated by steady green light in all line push buttons.
To override this function with gooseneck microphone
Press the TALK button on the operation panel.
Speak clearly into the microphone. When the TALK button is released the system will be in “audio to all” mode again.
PTT SWITCH
ETC-1-TB
To override this function with ETB-10A and hand microphone ETC-1-TB
Press the PTT SWITCH on hand microphone.
Speak clearly into the microphone. When the TALK button is released the system will be in “audio to all” mode again.
PTT SWITCH
Operationpanel with hand microphone P-66
Press the PTT SWITCH..
Speak clearly into the microphone. When the PTT SWITCH button is released the operation panel will be in “audio to all” mode again.
To end the function
Switch off the external audio.
Installation & User Manual System CTB-100V
26
4.1.10 Public Address Operation of external system
The four last line push buttons on the operation panels can be set to access 1 to 4 public address zones. CTB-10 & CTB-10W_V01: Push button marked 7-8-9- 10 CTB-20 & CTB-20W_V01: Push button marked 17-18-19-20 ALL button will access “all” inclusive Public Address Operation. Operation panel with higher priority will override ongoing PA-message
CTB-10 & CTB-10W_V01
CTB-20 & CTB-20W_V01
Press desired LINE button (s), the Public Address call is set up.
Indicated by steady green LED. Single or group of zones
Operation panel with gooseneck microphone MB-30G
Press the TALK button.
Speak clearly into the microphone for giving the message.
PTT SWITCH
ETC-1-TB
Operation panel with hand microphone ETC-1-TB
Press the PTT SWITCH..
Speak clearly into the microphone for giving the message.
PTT SWITCH
Operation panel with hand microphone P-66
Press the PTT SWITCH..
Speak clearly into the microphone for giving the message.
CTB-10 & CTB-10W_V01
CTB-20 & CTB-20W_V01
To end the function
Press line button (s) or ALL once more to end the Public Address
Operation
Installation & User Manual System CTB-100V
27
4.1.11 Emergency Public Address Operation.
In order to comply with PA-requirements, two PA call stations are required: The CTB-100V system are designed for use with up to four operation panels that can be used as Emergency call stati ons. I n ad di t i on o ne or more All call station (Ex. Lifeboat stations) can be used as Emergency call stations. Following functions:
Mute of the External Alarm System (General / Fire Alarm)
Operation panel with 1
st
priority, normally bridge, can override other operation panels.
Type of Operation panels/ Emergency call stations:
CTB-10 Operation panel 10 line selection, in do o r use. Hand or gooseneck microphone.
CTB-10W/V01 Operation panel 10 li ne selection, WP. Handmicrophone onl y.
CTB-20 Operation panel 20 line selection, in do o r use. Hand or gooseneck microphone.
CTB-20W/V01 Operation panel 20 li ne selection, WP. Handmicrophone onl y.
VMT-603 All call station WT with handmicrophone.
Central unit CU-200
ON OFF
VPA-120
POWER AMPLIFIER
100V POWER AMPLIFIER
From 1 of 4 operation panels.
Press the ALL button, the call is set up. Indicated by steady green LED
in the ALL button.
“EMERGENCY PA­BUTTON”
With gooseneck microphone MB-30G CTB-10 & CTB-20
Press the TALK marked “EMERGENCY PA –BUTTON.”
Speak clearly into the microphone to give message.
Loading...