Vingtor SP-5T, SP-5MT, SP-5HT, H66-SP5, SP5-36-PELP Technical User's Manual

TECHNICAL & USER MANUAL
SP-5T Common Line Intercom System
A100K10870
2
A100K10870
SP-5T Technical & User Manual
Document Scope
This document describes the system features, available
equipment, typical congurations, simplied wiring and technical specications for the SP-5T Common Line Intercom System.
Publication Log
Rev. Date Author Comments
0.0 2002.05.07 SEN
First release Zenitel Marine. main units with new circuit, balanced output. Ver. 01
0.1 2002.08.20 SEN
Documents for Ver. 02 in addition SP-5MT & HT with new PCB. Type VP1207 (Ecas) same function.
1.0 2010.08.25 SEN
New front and back page, new datasheets Doc.no. SP-5T_ut Rev.01 is replaced by document no. A100K10870
1.1 2011.04.11 HKL
Handheld mic type H66-SP5 Headset type SP5-36-PELP Proofread and converted all contents into Indesign format
Related Documentation
Documentation Doc. no.
Datasheet - SP-5MT A100K10948
Datasheet - SP-5HT A100K10947
Datasheet - SP-36-PELP A100K10949
Datasheet - H66-SP5 A100K10944
Datasheet - Power Amplier VPA-120 A100K10504
Datasheet - Power Amplier VPA-240 A100K10505
Datasheet - Power Amplier VPA-400 A100K10506
Datasheet - Amplier Rack RS-3C A100K10711
Cable Connection Diagram - SP-5T SP-5T_cc_wd
Cable Connection Diagram - SP-5T Ver. 02 SP-5T Ver.02_cc_wd
Wiring Diagram - Amplier Rack RS-3C RS-3C_wd rev.02
Installation & User Manual - VPA-120/VPA-240/VPA-400 A100K10875
Zenitel Norway AS and its subsidiaries assume no responsibilities for any errors that may appear in this publication, or for damages arising from the information in it. No information in this publication should be regarded as a warranty by Zenitel Norway AS.
The information in this publication may be updated or changed without notice. Product names mentioned in
this publication may be trademarks and are used only for identication.
Zenitel Norway AS © 2011
SP-5T Technical & User Manual
A100K10870
3
Contents
1 General Description .........................................................................4
2 Installation Instructions ...................................................................5
2.1 General .....................................................................................5
2.2 Cable Requirements .................................................................5
2.3 Level Adjustment .......................................................................5
3 User Instructions ..............................................................................6
4 Connection Diagrams & Dimension Drawings .............................. 7
4.1 SP-5T Ver. 02 Cable Connection Diagram ............................... 7
4.2 SP-5T Cable Connection Diagram ............................................8
4.3 SP-5MT Microphone Station ..................................................... 9
4.4 SP-5HT Microphone Station .....................................................9
4.5 SP5-36-PELP Headset ...........................................................10
4.6 H66-SP5 Handheld Microphone .............................................10
5 Specications ................................................................................. 11
5.1 SP-5MT Microphone Station ................................................... 11
5.2 SP-5HT Microphone Station ................................................... 11
5.3 SP5-36-PELP Headset ........................................................... 11
5.4 H66-SP5 Handheld Microphone ............................................. 11
4
A100K10870
SP-5T Technical & User Manual
General Description1
The SP-5T Common Line Intercom System provides All-to-All communication between a specied numbers of microphone or headset stations.
The number of stations that can be connected depends on output
power and loudspeaker tapping.
Note that product versions 01 & 02 have the same functions, except L they have different PCBs.
The system consists of :
Watertight Microphone station, type SP-5MT
for handheld microphone, type H66-SP5 -
Watertight Microphone station, type SP-5HT
for headset with boom-microphone, type SP5-36-PELP -
100V line loudspeaker for each station
Rack, type RS-3C with VPA-120, VPA-240, or VPA-400 power amplier
Loading...
+ 8 hidden pages