Viking Range VEWD172, VEWD102, VEWD162, VEWD172T, VEWD162T Installation Instructions Manual

...
INSTALLATION INSTRUCTIONS
BUILT-IN ELECTRIC WARMING DRAWER (INDOOR AND OUTDOOR MODELS)
VIKING RANGE CORPORATION
111 FRONT STREET
GREENWOOD, MISSISSIPPI 38930 USA
(662) 455-1200
•Before beginning, please read these instructions completely and carefully.
•Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.
•Please observe all local ordinances. If local codes are applicable, wire in accordance with the National Electrical Code, ANSI/NFPA 70 - latest edition.
•WARNING - To reduce the risk of electric shock and fire, do not use a flexible power-supply cord with this appliance.
•WARNING - FOR OUTDOOR INSTALLATION, INSTALLER MUST INSTALL A GROUND FAULT INTERRUPT.
•The installer should leave these instructions with the consumer who should retain for local inspector’s use and for future reference.
WARNING!!!
Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying voltage, hertz, wattage, amps, and phase is attached to the product. Wiring the warming drawer with more voltage than it is rated for may cause severe damage to the thermostat, element, and other components. Wiring the warming drawer with less voltage than it is rated for may cause significant decrease in performance. To reduce the risk of fire, electric shock, or injury to persons, installation work and electrical wiring must be done by qualified people in accordance with all applicable codes and standards, including fire-rated conditions.
GENERAL INFORMATION
THIS UNIT IS NOT TO BE INSTALLED BELOW CABINETS OR WALL MOUNTED.
•When installing this unit directly below other units, only install with Viking built-in products
•Remove warming drawer carefully from carton. Remove all loose packaging and accessories.
•It is the responsibility of the installer to comply with local codes. If no local codes are applicable, wire in accordance with the National Electrical Code, ANSI/NFPA 70 - latest edition.
•This appliance is not fused. Protect with a proper sized fuse or circuit breaker and a GFI for outdoor models.
•Line disconnect switch, circuit breaker, GFI (for outdoor models) or plug/receptacle of power cord connection should be readily accessible to the operator.
•Ground unit per applicable electrical codes.
•Any installation not matching the specifications discussed in these instructions will void the manufacturer’s warranty.
ELECTRICAL CONNECTION - USE COPPER CONDUCTORS ONLY.
GROUNDING INSTRUCTIONS
This appliance must be connected to a grounded metal, permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on
the appliance.
With the appliance positioned in front of the cabinet opening, connect wire leads extending from the power supply to the terminal block of the unit. Make sure the colored wires of the terminal block are connected to the corresponding colored wires extending from the power supply.
1
WIRING DIAGRAM
BUILT-IN ELECTRIC WARMING DRAWER
ELEMENT PJ010008 - 36” PJ010009 - 30” PJ010010 - 27”
WHITE 15”
WHITE 10”
GREEN/YELLOW 6”
GROUND
BLACK 15”
TERMINAL BLOCK PE070147
THERMOSTAT PB10167
INDICATOR LIGHT
PE050024
RED 6” RED 10”
NEUTRAL
GROUND
LINE
POWER SUPPLY CONNECTIONS BY INSTALLER
WARNING: FOR OUTDOOR UNITS ­INSTALLER MUST SUPPLY GFC INTERRUPT
FOR CONNECTION TO THE FACTORY
INSTALLED TERMINAL BLOCK, USE
COPPER CONDUCTORS ONLY
WARNING
::
TO REDUCE THE RISK OF
ELECTRIC SHOCK AND FIRE, DO NOT
USE A FLEXIBLE POWER-SUPPLY CORD
WITH THIS APPLIANCE.
BASIC SPECIFICATIONS
MODEL VEWD172 VEWD102 VEWD162
VEWD172T VEWD102T VEWD162T
Interior width 17 1/4 (43.8 cm) 20 1/2” (52.1 cm) 25” (63.5 cm)
Interior height 6” (15.2 cm) 6” (15.2 cm) 6” (15.2 cm)
Interior depth 22 3/4” (27.8 cm) 22 3/4” (27.8 cm) 22 3/4” (27.8 cm)
Electrical Hard wire direct with separate 15 amp minimum 2-wire with
Requirements ground circuit; 120 VAC/50-60 Hz
Max. Amp Usage 425 watts 450 watts 550 watts
3.6 amps 3.8 amps 4.6 amps
Approx. shipping Wt. 80 lb. (36 kg) 90 lb. (40.5 kg) 110 lb. (49.5 kg)
2