Viking Installation Guide
Built-In Gas Cooktops
3
DESCRIPTION DGCU105 (30” W.) DGCU165 (36” W.) DGCU155 (45” w.)
Cutout Width - Minimum 28-3/4” (73.0 cm) 34-1/2” (87.6 cm) 42-7/8” (108.9 cm)
Maximum 29-7/8” (75.9 cm) 35-7/8” (91.1 cm) 44-1/8” (112.1 cm) Cutout Height - Minimum 2-3/4” (7.0 cm) Cutout Depth - Minimum 19-11/16” (50.0 cm)
Maximum 20-1/2” (52.1cm) Overall Width 30-3/4” (78.1 cm) 36-3/4” (93.3 cm) 45” (114.3 cm) Overall Height from Bottom (including connector) 4-1/4” (10.8 cm) Overall Depth from Rear 21” (53.3 cm) Gas Requirements Not field convertible - Must be ordered from factory either natural or LP/Propane. Uses
standard residential 1/2” (1.3 cm) I.D. gas service line.
Electrical Requirements 120 VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product. Maximum Amp Usage 2.0 amps Surface Burner Rating
Left Front- 14,000 Nat./13,500 LP (BTU) 12,000 Nat./11,500 LP (BTU) 12,000 Nat./11,500 LP (BTU)
(4.1 Nat./4.0 LP [kw]) (3.5 Nat./2.8 LP [kw]) (3.5 Nat./2.8 LP [kw])
Left Rear- 12,000 Nat./11,500 LP (BTU) 10,000 Nat./LP (BTU) 8,000 Nat./LP (BTU)
(3.5 Nat./2.8 LP [kw]) (2.9 Nat./LP [kw]) (2.1 Nat./LP [kw])
Left Center N/A 14,000 Nat./13,500 LP (BTU) 10,000 Nat./LP (BTU)
(4.1 Nat./4.0 LP [kw]) (2.9 Nat./LP [kw])
Right Center N/A N/A 14,000 Nat./13,500 LP (BTU)
(4.1 Nat./4.0 LP [kw])
Right Rear- 8,000 Nat./LP (BTU) 8,000 Nat./LP (BTU) 6,000 Nat./LP (BTU)
(2.1 Nat./LP [kw]) (2.1 Nat./LP [kw]) (1.8 Nat./LP [kw])
Right Front- 6,000 Nat./LP (BTU) 6,000 Nat./LP (BTU) 8,000 Nat./LP (BTU)
(1.8 Nat./LP [kw]) (1.8 Nat./LP [kw]) (2.1 Nat./LP [kw])
Approximate Shipping Weight 67 lb. (30.2 kg.) 80 lb. (36.0 kg) 93 lb. (41.9 kg)
DESCRIPTION VGSU103 (30” W.) VGSU163 (36” W.)
Cutout Width - Minimum 26-7/8” (68.3 cm) 34-3/8” (87.3 cm)
Maximum 29-7/8” (75.9 cm) 35-7/8” (91.1 cm) Cutout Height - Minimum 2-1/2” (6.4 cm) Cutout Depth - Minimum 18-5/8” (47.3 cm)
Maximum 20-1/8” (51.1cm) Overall Width 30-3/4” (78.1 cm) 36-3/4” (93.3 cm) Overall Height from Bottom 5” (12.7 cm) Overall Depth from Rear 21” (53.3 cm) Gas Requirements To field convert from natural or LP/Propane, the orifice spuds and regulator must be physically
changed. Order conversion kit NK2VGSU to convert to natural and LPK3VGSU to convert to LP.
Uses standard residential 1/2” (1.3 cm) I.D. gas service line.
Electrical Requirements 120 VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product. Maximum Amp Usage 2.0 amps Surface Burner Rating
Left Front- 16,000 Nat./15,500 LP (BTU) 16,000 Nat./15,500 LP (BTU)
(4.8 Nat./4.65 LP [kw]) (4.8 Nat./4.65 LP [kw])
Left Rear- 12,000 Nat./11,500 LP (BTU) 12,000 Nat./11,500 LP (BTU)
(3.6 Nat./3.45 LP [kw]) (3.6 Nat./3.45 LP [kw])
Center Front/Rear N/A 12,000 Nat./11,500 LP (BTU)
(3.6 Nat./3.45 LP [kw])
Right Rear- 8,000 Nat./7,500 LP (BTU) 8,000 Nat./7,500 LP (BTU)
(2.4 Nat./2.25 LP [kw]) (2.4 Nat./2.25 LP [kw])
Right Front- 6,000 Nat./5,500 LP (BTU) 6,000 Nat./5,500 LP (BTU)
(1.8 Nat./1.65 LP [kw]) (1.8 Nat./1.65 LP [kw])
Approximate Shipping Weight 67 lb. (30.2 kg.) 80 lb. (36.0 kg)
BASIC SPECIFICATIONS
1. Before beginning, please read these instructions completely and carefully.
2. Do not remove per manently affixed labels, warnings, or plates from product. This may void the warranty.
3. Please observe all local and national codes and ordinances.
4. Please ensure that this product is properly grounded.
5. The installer should leave these instructions with the consumer who should retain for local inspector’s use and for future reference.
Installation must conform with local codes or, in the absence of codes, the National Fuel Gas Code, ANSI Z223.1 or the latest edition. In Canada: Installation must be in accordance with the current CAN/CGA B149.1 & 2 Gas Installation codes and/or local codes. Electrical installation must be in accordance with the current CSAC22.1 Canadian Electrical Codes Part 1 and/or local codes.
Installation of any gas-fired equipment should be made by a licensed plumber. A manual gas shut-off valve must be installed in the gas supply line ahead of the cooktop in the gas stream for safety and ease of service.
In Massachusetts: All gas products must be installed by a “Massachusetts” licensed plumber or gasfitter. A “T” handle type manual gas valve must be installed in the gas supply line to the appliance.
1. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
2. WHAT TO DO IF YOU SMELL GAS:
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone
in your building.
•Immediately call your gas supplier from a neighbor’s
phone.
•Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire
department.
3. Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
WARNING
If not installed, operated and maintained in accordance with the manufacturer’s instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness and which are known to cause cancer, birth defects, or other reproductive harm.
WARNING: IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
For example, benzene is a chemical which is part of the gas supplied to the cooking product. It is consumed in the flame during combustion. However exposure to a small amount of benzene is possible if a gas leak occurs. Formaldehyde and soot are by­products of incomplete combustion. Properly adjusted burners with a bluish rather than yellow flame will minimize incomplete combustion.
WARNING!!
ELECTRICAL GROUNDING INSTRUCTIONS
The cooktop must be electrically grounded in accordance with local codes or, in the absence of codes, with the ANSI/NFPA No. 70-latest edition. Installation should be made by a licensed electrician. This appliance is equipped with a three-prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle. Do not cut or remove the grounding prong from the plug.
For personal safety, this appliance must be properly grounded. Do not under any
circumstances cut or remove the third (ground) prong from the power plug.
2
IMPORTANT: PLEASE READ AND FOLLOW
PROXIMITY TO SIDE CABINETS
1. The cooktop may be installed directly to existing base cabinets.
2. The cooktop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36” (91.4 cm) high. There must be a minimum of 8” (20.3 cm) side clearance from the cooktop to such combustible surfaces above the 36” (91.4 cm) counter height.
3. Within the 8” (20.3 cm) side clearance to combustible vertical surfaces above 36” (91.4 cm), the maximum wall cabinet depth must be 13” (33.0 cm) and wall cabinets within this 8” (20.3 cm) side clearance must be 18” (45.7 cm) above the 36” (91.4 cm) high countertop.
4. Wall cabinet above the cooktop must be a minimum of 36” (91.4 cm) above the countertop for a full width of the cooktop. This minimum height requirement does not apply if a rangehood is installed over the cooking surface.
5. A 120 volt wall receptacle should be located approximately 6” (15.2 cm) below the countertop cutout and 12”
(30.5 cm) from the right side of the cutout.
MINIMUM CLEARANCES FROM ADJACENT COMBUSTIBLE CONSTRUCTION
•Above countertop (above 36” [91.4 cm])
•Sides 8” (20.3 cm)
•Rear - See chart dimension “A”
•Within 8” (20.3 cm) side clearance. Wall cabinets no deeper than 13” (33.0 cm)
•Must be minimum 18” (45.7 cm) above countertop
•Wall cabinets directly above the product must be minimum 36” (91.4 cm) above the countertop.
5
13” max. (33.0 cm)
36” min. (91.4 cm)
18” min. (45.7 cm)
8” min. (20.3 cm)
3-1/8” (7.9 cm)
36” min. (91.4 cm)
A VGSU 3-1/2” (8.9 cm) min. DGCU/DGSU 2-1/2” (6.4 cm) min.
A
4
GENERAL INFORMATION
1. WARNING: The use of cabinets for storage above the appliance may result in a potential bur n hazard.
Combustible items may ignite, metallic items may become hot and cause bur ns. If a cabinet storage is to be provided the risk can be reduced by installing a rangehood that projects horizontally a minimum of 5” (12.7 cm) beyond the bottom of the cabinets.
2. WARNING: This appliance shall not be used for space heating. This information is based on safety
considerations.
3. All openings in the wall behind the appliance and in the floor under the appliance shall be sealed.
4. Keep appliance area clear and free from combustible materials, gasoline, and other flammable vapors.
5. Do not obstruct the flow of combustion and ventilation air.
6. Disconnect the electrical supply to the appliance before servicing.
7. When removing cooktop for cleaning and/or service; A. Shut off gas at main supply B. Disconnect AC power supply C. Disconnect gas line to the inlet pipe. D. Lift appliance out of cabinet cutout.
8. Electrical Requirement Normal grounded household current, 120 volts, 60 Hz, 15 amps, single phase. Electrical installation should comply with national and local codes.
9. Air Supply and Ventilation Means must be provided for any heavy-duty cooking appliance to exhaust combustion waste product to the outside of the building. It is recommended that the cooktop be set under a powered, vented exhaust hood, or non-vented recirculating hood. Nothing should obstruct the flow of combustion and ventilation air.
10. Gas Manifold Pressure
Natural gas - 5.0” W.C.P.
11. Flexible Connections
If the unit is to be installed with flexible couplings and/or quick disconnect fittings, the installer must use a flexible connector of at least 1/2” I.D. (1.3 cm) NPT with suitable strain reliefs and comply with ANSI Z21.41 and Z21.69 standards.
DESCRIPTION DGSU100 (30” W.) DGSU160 (36” W.)
Cutout Width - Minimum 29-1/8” (74.0 cm) 34-7/8” (88.6 cm)
Maximum 29-7/8” (75.9 cm) 35-7/8” (91.1 cm) Cutout Height - Minimum 3-1/8” (7.9 cm) Cutout Depth - Minimum 19-3/4” (50.2 cm)
Maximum 20-1/8” (51.1cm) Overall Width 30-3/4” (78.1 cm) 36-3/4” (93.3 cm) Overall Height from Bottom 4-3/8” (10.5 cm) Overall Depth from Rear 21” (53.3 cm) Gas Requirements To field convert from natural or LP/Propane, the orifice spuds and regulator must be physically
changed. Order conversion kit DLPK to convert to LP. Uses standard residential 1/2” (1.3 cm)
I.D. gas service line.
Electrical Requirements 120 VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product. Maximum Amp Usage 2.0 amps Surface Burner Rating
Left Front- 14,000 Nat./13,500 LP (BTU) 12,000 Nat./11,500 LP (BTU)
(4.1 Nat./4.0 LP [kw]) (3.5 Nat./2.8 LP [kw])
Left Rear- 12,000 Nat./11,500 LP (BTU) 10,000 Nat./LP (BTU)
(3.5 Nat./2.8 LP [kw]) (2.9 Nat./LP [kw])
Center Front/Rear N/A 14,000 Nat./13,500 LP (BTU)
(4.1 Nat./4.0 LP [kw])
Right Rear- 8,000 Nat./LP (BTU) 8,000 Nat./LP (BTU)
(2.1 Nat./LP [kw]) (2.1 Nat./LP [kw])
Right Front- 6,000 Nat./LP (BTU) 6,000 Nat./LP (BTU)
(1.8 Nat./LP [kw]) (1.8 Nat./LP [kw])
Approximate Shipping Weight 49 lb. (22.0 kg.) 74 lb. (33.3 kg)