Viking Range BRTGK72SS, PBRTGK72SS Installation Instructions Manual

VIKING RANGE CORPORATION
Please refer to Installation Instructions provided with bottom mount refrigerator/freezer for additional information.
Most of the refrigerators weight is at the top. Extra care is needed when moving the refrigerator to prevent tipping. Keep cardboard shipping piece or plywood under refrigerator until it is install
ed in
the operating position.
Your safety and the safety of others
is very important.
You will be killed or seriously injur
ed if you
don’t follow instructions.
You can be killed or seriously injured if you don’t follow inst
ructions.
TIP OVER HAZARD Refrigerator is top heavy and tips easily when not completely installed. Keep doors
closed until refrigerator is
completely installed and secured with lag bolts to rear wall. Use two
or more people to move
and install refrigerator. Failure to do so can result in death or serious i
njury
INSTALLATION
Greenwood, Mississippi 38930 USA
111 Front Street
INSTRUCTIONS
BUILT-IN BOTTOM MOUNT REFRIGERATOR/FREEZER BRTGK72SS/PBRTGK72SS GRILLE KITS (FOR PROFESSIONAL SERIES ONLY)
IMPORTANT - PLEASE READ AND FOLLOW
Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying voltage, frequency, wattage, amperage, and phase is attached to the product.
To reduce the risk of fire, electric shock, or injury to persons, installation work and electrical wiring must be done by qualified people in accordance with all applicable codes and standards, including fire-rated construction.
The installer should leave these instructions with the consumer who should retain for local inspector’s use and for future reference.
GENERAL INFORMATION
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This
symbol alerts you to hazards that can kill or hurt you and others.
All safety messages will be preceded by the safety alert symbol and the word “DANGER” or “WARNING”. These words mean:
All safety messages will identify the hazard, tell you how to reduce the chance if injury, and tell you what can happen if the instructions are not followed.
r
e
It is your responsibility to :
-comply with installation specifications and dimensions
-properly install refrigerator
-remove any moldings or decorative panels that prevent the refrigerator from being serviced
-make sure that you have these materials, (not provided with the unit), which are necessary for proper installation:
2 - 1/4” (6 mm) copper tubing with shutoff valve 2 - 1/4” (6mm) compression fitting #8 x 3” (7.6 cm) wood screws (Longer screws may be required.)
BRTGK72SS - Qty 12 PBRTGK72SS - Qty 12
2 - saddle valves (do not use self-piercing valves).
n
e
-assure that floor will support refrigerator, door panels and contents, (approximately 1200 lbs. [540 kg.])
-provide a properly grounded electrical outlet
-assure that location will permit appliance doors to open 90
o
minimum
BASIC SPECIFICATIONS AND DIMENSIONS
DESCRIPTION BRTGK72SS PBRTGK72SS
(per unit)
VCBB363-DUAL INSTALLATION
Overall Width 72” (182.9 cm)
Overall Height from Bottom Min. 82 3/4” (210.2 cm)
Overall Depth from Rear To rear edge of side trim 22 3/16” (56.4 cm)
To front of top grille 24 11/16” (62.7 cm) To end of handle bracket 27 1/4” (69.2 cm)
Cutout Width 71 1/2” (181.6 cm)
Cutout Height Min. 82 7/8” (210.3 cm)
Cutout Depth 24” (61.0 cm) min.
Electrical Requirements (2) - 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with grounded 3-
prong plug attached to product.
Maximum Amp Usage 9.9 amps (per unit)
Inlet Water Requirements (2) - 1/4” copper tubing inlet waterline; minimum 20 psi; maximum 120 psi
Overall Interior Capacity
•Refrigerator 15.2 cu. ft. (.43 cu. meters)
•Freezer 5.1 cu. ft. (.14 cu. meters)
•Total Capacity 20.3 cu. ft. (.57 cu. meters)
Approximate Shipping Weight 575 lbs. (258.8 kg) - per unit
Max. 84 1/16” (213.5 cm)
Max. 84 1/16” (213.5 cm)
2
SITE PREPARATIONS AND CONSIDERATIONS
ELECTRICAL RECEPTACLE LOCATIONS (SHADED AREAS)
1” (2.5 cm) TYP
FOUR (2 per unit)
82 7/8 (210.5 cm) Min.
anti-tip board and opening height
84 1/16 (213.5 cm) Max.
anti-tip board and opening height
71 1/2” (181.6 cm) FOR TWO
PROFESSIONAL STYLE 36” W.
BOTTOM MOUNT REFRIGERATORS
35 13/16” (91.5 cm)
39 3/16” (99.5 cm)
Water line entry area
Water
line
Water line
BRTGK72SS PROFESSIONAL 36” W. BOTTOM MOUNT DUAL INSTALLATION, CABINET OPENING DIMENSIONS
3
(2 per unit) 2” x 4” mounting boards (1-1/2” [3.8 cm] x 3-1/2” [8.9 cm]) NOTE: If unit is installe
d deeper than 24” (61.0 cm), then shim behind anit-tip bracket
thickness by the same amount.
29” (73.7 cm) 29” (73.7 cm)
3” (7.6 cm)
3-1/2” (8.9 cm)
3-1/2” (8.9 cm)
Bottom of anti-tip board is 3-7/8” (9.8 cm) below opening height. NOTE: Top of unit must be firmly
seated under anti-tip
board.
6”
(15.2 cm)
6”
(15.2 cm)
9” (22.2 cm)
Water line entry area
82-7/8 (210.5 cm) min. anti-tip board and opening height
84-1/16 (213.5 cm) max. anti-tip board an
d opening height
73-3/8
(186.4 cm)
SITE PREPARATIONS AND CONSIDERATIONS
71 1/2” (181.6 cm) FOR TWO
PROFESSIONAL STYLE 36” W.
BOTTOM MOUNT REFRIGERATORS
Water Line
Water Line
24” (61.0 cm)
PBRTGK72SS PROFESSIONAL 36” W. BOTTOM MOUNT DUAL INSTALLATION, CABINET OPENING DIMENSIONS
d
Electrical outlet location
Electrical outlet location
s
d
4