Viking Range 30” Professional Integrated VIFB304, 30 Professional VCFB304, 36 Professional VCFB364, 30” Professional Integrated VIRB304, 36” Professional Integrated VIFB364 Installation Manual

...
Viking Range Corporation
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information,
call 1-888-VIKING1 (845-4641)
or visit the Viking Web site at
vikingrange.com
(071508J)
Viking Installation Guide
All Refrigerator/Freezer
U
L
C
U
L
3
2
Table of Contents IMPORTANT–Please Read and Follow!
Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying voltage, frequency, wattage, amperage, and phase is attached to the product.
• To reduce the risk of fire, electric shock, or injury to persons, installation work and electrical wiring must be done by qualified people in accordance with all applicable codes and standards, including fire-rated construction.
• The installer should leave these instructions with the consumer who should retain them for local inspector’s use and for future reference.
It is your responsibility to:
• comply with installation specifications and dimensions.
• properly install unit.
• remove any moldings or decorative panels that prevent the unit from being serviced.
• make sure that you have these materials (not provided with your unit), which are necessary for proper installation:
• 1/4” (6 mm) copper tubing with shutoff valve
• 6– #8 x 3” (7.6 cm) wood screws (longer screws may be required)
• 1– Saddle valve (do not use self-piercing feature of the valve)
• assure that floor will support unit, door panels and contents (approximately 1200 pounds [540 kg]).
• provide a properly grounded electrical outlet.
• assure that location will permit appliance doors to open 90˚ minimum.
W A R N I N G
TIP OVER HAZARD
Appliance is top heavy and tips easily when not completely installed. Keep doors closed until appliance is completely installed and secured per installation instructions.
Use two or more people to move and install appliance. Failure to do so can result in death or serious injury.
W A R N I N G
ELECTRICAL SHOCK HAZARD
Disconnect power or turn power disconnect switch to OFF position before removing top grille. Failure to do so can result in death or electrical shock.
Your safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others.
All safety messages will be preceded by the safety alert symbol and the word“DANGER” or “WARNING.”These words mean:
D A N G E R
You will be killed or seriously injured if
you don’t follow instructions.
W A R N I N G
You can be killed or seriously injured if
you don’t follow instructions.
All safety messages will identify the
hazard, tell you how to reduce the chance
of injury, and tell you what can happen if
the instructions are not followed.
Most of the unit’s weight is at the top. Extra care is needed when moving the unit to prevent tipping. Use cardboard shipping material or plywood under unit until it is installed in the operating position to protect floor surface.
Warnings & Important Information
_________________________________________________________
3
Professional & Professional Integrated
Dimensions & Specifications (30” & 36” Professional) _______________________________ 4 Dimensions & Specifications (30” & 36” Professional Integrated) _____________________ 6 Cutout Dimensions (30” Professional & Professional Integrated) ______________________ 8 Anti-Tip Dimensions (30” Professional & Professional Integrated) _____________________ 9 Cutout Dimensions (36” Professional & Professional Integrated) _____________________ 10 Anti-Tip Dimensions (36” Professional & Professional Integrated) _____________________ 11 Dimensions & Specifications (Dual Professional) ____________________________________ 12 Dimensions & Specifications (Dual Professional Integrated) ___________________________16 Cutout Dimensions (Dual 30” Professional & Professional Integrated) _________________ 20 Anti-Tip Dimensions (Dual 30” Professional & Professional Integrated) ________________ 21 Cutout Dimensions (Dual 30” & 36” Professional & Professional Integrated) ___________ 22 Anti-Tip Dimensions (Dual 30” & 36” Professional & Professional Integrated) __________ 23 Cutout Dimensions (Dual 36” Professional & Professional Integrated) _________________24 Anti-Tip Dimensions (Dual 36” Professional & Professional Integrated) _________________25 Cabinet Infor mation (Professional) ________________________________________________ 26 Cabinet Infor mation (Professional Integrated) ______________________________________ 28
Designer
Dimensions & Specifications (30”& 36”) ___________________________________________ 30 Cutout Dimensions (30”)_________________________________________________________ 32 Anti-Tip (30”) ___________________________________________________________________ 33 Cutout Dimensions (36”)_________________________________________________________ 34 Anti-Tip Dimensions (36”)________________________________________________________ 35 Dimensions & Specifications (Dual)________________________________________________ 36 Cutout Dimensions (Dual 30”) ____________________________________________________ 40 Anti-Tip Dimensions (Dual 30”) ___________________________________________________ 41 Cutout Dimensions (Dual 30” & 36”) ______________________________________________ 42 Anti-Tip Dimensions (Dual 30” & 36”) _____________________________________________ 43 Cutout Dimensions (Dual 36”) ____________________________________________________ 44 Anti-Tip Dimensions (Dual 36”) ___________________________________________________ 45
Cabinet Infor mation_____________________________________________________________ 46 Custom Side Panel Dimensions (Professional) __________________________________________ 48 Custom Side Panel Dimensions (Designer & Professional Integrated) _____________________ 49 General Infor mation ________________________________________________________________ 50
Unpacking & Moving____________________________________________________________ 52 Installation_________________________________________________________________________ 53
Hinge Adjustment ______________________________________________________________ 54
Kickplate Installation ____________________________________________________________ 56
Door Stop Adjustment __________________________________________________________57
Final Installation ________________________________________________________________57 Performance Checklist ______________________________________________________________59 Control Panels _____________________________________________________________________60 Service & Registration_______________________________________________________________61
5
24–1
1
/1
6
(62
.
7
cm)
35”
(8
8
.9
cm)
75–
15/
16”
(
1
9
2
.9
cm
)
3–1
9
/
32
(
9
.1
cm
)
)
36
(
91
.
5
cm)
27–
1
/4
(
69
.2 c
m)
9
–5
/
32
(
23
.
3
c
m)
82
3
/4
(
21
0
.2
cm
)
m
in
.
to
8
4
1/1
6”
(
21
3
.
5
cm
)
m
ax
.
20–
3/4
(52
.7
c
m)
22
–3/1
6”
(5
6
.4
c
m
)
2
4–
1
1/16
(62
.7
cm
)
29”
(7
3
.7
c
m
)
7
5
1
5
/
1
6
(
19
2.
9
cm
)
3
–1
9
/32”
(
9
.
1
c
m
)
3
0
(
7
6
.
2
cm)
9
5
/
3
2
(
2
3
.3
cm
)
82
3
/4
(21
0
.2
c
m)
min
.
to
8
4
1/1
6
(21
3
.5
c
m
)
max
.
20–
3/4
(
52
.7
c
m)
22
–3/
1
6”
(56
.4
c
m)
27–
1
/4”
(69
.2
c
m)
Dimensions
4
30” Professional
36” Professional
Specifications
30” Professional
Description VCFB304 VCRB304
Overall width 30” (76.2 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 22-3/16” (56.4 cm)
To front of top grille: 24-11/16” (62.7 cm) To front of handle endcap: 27-1/4” (69.2 cm))
Cutout width 29-1/2” (74.9 cm) min. to 29-3/4” (75.6 cm) max. Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.1 amps 5.7 amps Inlet water requirements 1/4” copper tubing inlet
waterline; minimum 20 psi; N/A
maximum 120 psi
Overall interior dimensions Total capacity 15.9 cu. ft. (450 liters) 18.2 cu. ft. (516 liters) Approximate shipping weight 530 lbs. (238.5 kg) 505 lbs. (227.3 kg)
36” Professional
Description VCFB364 VCRB364
Overall width 36” (91.5 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 22-3/16” (56.4 cm)
To front of top grille: 24-11/16” (62.7 cm) To front of handle endcap: 27-1/4” (69.2 cm)
Cutout width 35-1/2” (90.2 cm) min. to 35-3/4” (90.8 cm) max. Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.5 amps 6.5 amps Inlet water requirements 1/4” copper tubing inlet
waterline; minimum 20 psi; N/A
maximum 120 psi
Overall interior dimensions Total capacity 19.1 cu. ft. (541 liters) 22.8 cu. ft. (646 liters) Approximate shipping weight 585 lbs. (263.3 kg) 570 lbs. (256.5 kg)
Specifications
7
2
4
(61
.0
cm)
35”
(88
.9
c
m)
75–
15/
16”
(
1
9
2.9 c
m
)
3
–19
/3
2
(
9
.
1
c
m
)
)
3
6
(9
1
.5
c
m
)
26–
1/2”
(
6
7
.3 c
m)
9–5
/3
2
(
23
.
3
cm)
82
3/4”
(
21
0
.
2
c
m)
m
i
n
.
t
o
84–
1
/
1
6
(
21
3
.
5
cm
)
m
ax
.
20–
3
/4
(52
.7
c
m)
23–
3
/
8
(59
.4
cm
)
2
4”
(61
.0
cm
)
2
9
(
7
3
.
7
c
m
)
7
5
1
5
/
16”
(
1
9
2.
9
c
m
)
3–
19
/3
2
(
9
.1
cm
)
3
0
(76
.2
c
m
)
9–5
/32
(
23
.
3
c
m)
82
3/
4”
(
21
0
.
2
c
m
)
m
i
n
.
t
o
84–
1
/
1
6”
(
21
3.
5
cm
)
max
.
20–
3/4
(52
.7 c
m)
23–
3/
8”
(5
9
.4
cm)
26–
1/2”
(
67
.3 c
m)
Dimensions
6
30” Professional Integrated
36” Professional Integrated
30” Professional Integrated
Description VIFB304 VIRB304
O
verall width 30” (76.2 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8” (59.4 cm)
To front of top grille: 24” (61.0 cm) To front of handle endcap: 26-1/2” (67.3 cm)
Cutout width 30” (74.9 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.1 amps 5.7 amps Inlet water requirements 1/4” copper tubing inlet
waterline; minimum 20 psi; N/A
maximum 120 psi
Overall interior dimensions Total capacity 15.9 cu. ft. (450 liters) 18.2 cu. ft. (516 liters) Approximate shipping weight 530 lbs. (238.5 kg) 505 lbs. (227.3 kg)
36” Professional Integrated
Description VIFB364 VIRB364
Overall width 36” (91.5 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8” (59.4 cm)
To front of top grille: 24” (61.0 cm) To front of handle endcap: 26-1/2” (67.3 cm)
Cutout width 36” (91.4 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.5 amps 6.5 amps Inlet water requirements 1/4” copper tubing inlet
waterline; minimum 20 psi; N/A
maximum 120 psi
Overall interior dimensions Total capacity 19.1 cu. ft. (541 liters) 22.8 cu. ft. (646 liters) Approximate shipping weight 585 lbs. (263.3 kg) 570 lbs. (256.5 kg)
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
Note: Top of unit must be placed firmly under anti-tip board.
Professional Anti-Tip Location
Professional Integrated Anti-Tip Location
NOTE: If unit is installed deeper than
24” (61.0 cm),then shim behind the mounting
board by the difference.
NOTE: If unit is installed deeper than
24” (61.0 cm), then shim behind the mounting
board by the difference.
Two 2”x 4” mounting boards
3” (7.6 cm) x 3-1/2” (8.9 cm)
One 2”x 4” mounting board
1–1/2” (3.8 cm) x 3-1/2” (8.9 cm)
7
9–
3/8”
(20
1
.6
c
m)
mi
n.
t
o b
ot
t
o
m
of
a
nti
-
t
i
p
bo
a
rd
8
0–
1/2”
(20
4.6 c
m)
ma
x.
t
o b
ot
t
o
m
of
a
nti
-
t
i
p
bo
a
rd
23”
(58
.4
c
m)
3–
1/
2
(
8
.
9
c
m
)
3
(
7
.
6
c
m
)
2
3
(5
8
.4
c
m
)
3–
1/
2
(8
.9
cm
)
1–1
/2
(3.
8 c
m)
Anti-Tip Dimensions
9
9”
(
22
.
9
c
m)
73–
3/
8”
(18
6.4 c
m)
8
2–
7/8”
(2
1
0
.5
c
m)
mi
n
.
a
n
t
i
-
t
ip
b
o
ar
d
&
o
p
en
ing
he
igh
t
84–1
/16
(
2
1
3
.
5
c
m)
mi
n
.
an
t
i-t
ip
boa
r
d
&
ope
n
in
g h
e
ig
h
t
29–1
/
2”
(7
4
.9
cm)
m
i
n.
to
29
-
3/
4
(75
.6
c
m)
max
.
3
0
(7
6
.2
cm
)
Pro
fe
s
sio
na
l
I
n
t
e
g
r
a
t
ed
M
o
d
els
Onl
y
2
4”
(61
.0 c
m
)
Electric Outlet Location
Water Line Entry Area
Note: Shown for All Freezer Only
29–1/
2”
(
7
4
.9
c
m)
6–3/
4”
(
17
.1
cm
)
7–5/
8”
(
1
9
.4
c
m)
3”
(7.6
cm
)
5/8
(1.
5 c
m)
5/
8
(1.
5 c
m)
10–1
/2”
(26
.7
cm)
5
/8
(1.5
cm)
10–3/
4”
(27
.3
cm)
1”
(
2.
5
cm
)
3–5
/8”
(9.
2 c
m)
Op
t
io
n
al f
loo
r
wa
t
er
lin
e e
ntr
y
30”
(
7
6
.2
c
m)
Pr
o
f
e
ss
io
na
l I
nte
gra
ted
Mo
del
s On
ly
S
e
e
A
n
t
i-
T
ip b
o
a
r
d
i
n
st
a
l
l
a
t
io
n
6
(1
5
.
2
c
m)
9
(2
2
.
9
c
m)
Cutout Dimensions
8
30” Professional & Professional Integrated
30” Professional & Professional Integrated
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
Note: Top of unit must be placed firmly under anti-tip board.
7
9–
3/8”
(20
1
.6
c
m)
mi
n.
t
o b
ot
t
o
m
of
a
nt
i
-
t
i
p
bo
a
rd
8
0–
1/2”
(20
4.6 c
m)
ma
x.
t
o b
ot
t
o
m
of
a
nt
i
-
t
i
p
bo
a
rd
Professional Anti-Tip Location
Professional Integrated Anti-Tip Location
NOTE: If unit is installed deeper than
24” (61.0 cm), then shim behind the mounting
board by the difference.
NOTE: If unit is installed deeper than
24” (61.0 cm), then shim behind the mounting
board by the difference.
T
wo 2”x 4” mounting boards
3” (7.6 cm) x 3-1/2” (8.9 cm)
One 2”x 4” mounting board
1–1/2” (3.8 cm) x 3–1/2” (8.9 cm)
29–
1/
2”
(74
.9
c
m)
3–
1/
2
(
8
.
9
c
m
)
3
(
7
.
6
c
m
)
2
9
1
/2”
(7
4
.9
c
m
)
3–
1/
2”
(8
.9
cm
)
1–1
/2
(3.
8 c
m)
Anti-Tip Dimensions
11
9”
(
22
.
9
c
m
)
73–
3/
8”
(18
6.4 c
m
)
8
2–
7/8”
(2
1
0
.5
c
m)
mi
n
.
a
n
t
i
-
t
ip
b
o
ar
d
&
o
p
en
ing
he
igh
t
84–1
/16
(
2
1
3
.
5
c
m)
mi
n
.
an
t
i-t
ip
boa
r
d
&
ope
n
in
g h
e
ig
h
t
35–
1/
2
(90.
2 c
m
)
m
in
.
to
3
5
-
3/
4
(90
.8
cm
) m
ax.
3
6
(9
1
.4 c
m
)
P
ro
fes
si
o
nal
Int
egr
ate
d
M
o
d
els
On
ly
2
4”
(61
.
0 c
m
)
Electric Outlet Location
Water Line Entry Area
Note: Shown for All Freezer Only
35–1/
2”
(
9
0
.2
c
m)
6–3/
4”
(
17
.1
cm)
7–5/
8”
(
1
9
.4
c
m
)
3”
(7.6
cm
)
5/8
(1.
5 c
m
)
5/
8
(1.
5 c
m)
10–1
/2”
(26
.7
cm)
5
/8
(1.
5
cm
)
10–3/
4”
(27
.3
cm)
1
(
2.
5
cm
)
3–5
/8”
(9.
2 c
m)
Op
t
io
n
al f
loo
r
wa
t
er
lin
e e
ntr
y
36”
(
9
1
.4
c
m)
Pr
o
f
ess
io
n
a
l
Int
egr
a
te
d M
o
de
l
s On
ly
S
e
e
A
n
t
i-
T
ip b
o
a
r
d
i
n
st
a
l
l
a
t
io
n
6
(1
5
.
2
c
m)
9
(2
2
.
9
c
m)
Cutout Dimensions
10
36” Professional & Professional Integrated
36” Professional & Professional Integrated
2
4
1
1
/
1
6
(
62
.7
c
m)
1”
(2.
54
cm)
Bet
wee
n U
ni
ts
3
5
(8
8
.9 c
m
)
36
(
9
1
.
5 cm
)
9
5
/
3
2
(23
.
3
c
m)
8
2
3
/
4
(2
1
0.2 c
m
)
m
in
.
t
o
84
1/
16
(21
3.
5
cm
)
m
ax
.
2
0
3
/
4
(5
2
.7
c
m
)
2
2
–3
/
1
6
(5
6
.4
c
m
)
2
9”
(7
3
.7 cm)
7
5
–1
5
/1
6
(1
9
2 .
9 c
m
)
3–1
9/
3
2
(
9.
1
c
m
)
30
(
76
.
2 c
m
)
2
7–
1/4
(
69
.
2
c
m
)
Dimensions
13
24–
11
/
16
(6
2
.7 c
m
)
1”
(2.5
4 c
m)
Bet
ween
Un
its
9–5
/32”
(23
.3
c
m)
82
3/
4”
(
2
1
0
.
2
cm)
mi
n
.
to
84–
1/16
(
2
1
3.
5
cm
)
m
a
x
.
20–
3/4”
(52
.7
c
m)
22
–3/
16”
(56
.4
cm
)
7
5
1
5
/
1
6
(1
9
2
.
9
c
m
)
3
–1
9
/
3
2
(
9
.
1
c
m
)
2
9
(73
.7 c
m
)
2
9
(73
.7
c
m
)
3
0
(
7
6
.
2 c
m
)
30
(
76
.
2 cm
)
2
7–
1/4
(
69
.
2
cm
)
Dimensions
12
Dual 30” Professional
Dual 30” & 36” Professional
Specifications
15
24–
11
/1
6
(62
.7 c
m
)
1”
(2.54
cm
)
Bet
wee
n u
nit
s
35”
(
88
.
9
c
m
)
3
5
(
8
8
.
9 c
m
)
3
6
(
91
.
5
c
m)
36
(
9
1
.
5
c
m
)
9–5/
32”
(23
.3
c
m)
82–
3/4”
(
21
0
.2
c
m
)
m
in
.
to
8
4–
1/1
6”
(
21
3.5 c
m
)
ma
x
.
20
3
/4
(52
.7
cm)
22
–3/
16”
(56
.4
cm)
75–
15/
16”
(19
2 .
9 c
m
)
3
–1
9
/3
2
(
9
.
1
c
m)
2
7
1/
4
(
69
.
2 cm
)
Dimensions
14
Dual 36” Professional
Dual Professional
Description (2) 30” Units (1) 36” & (1) 30” Unit (2) 36” Units
O
verall width 60” (152.4 cm) 66” (167.6 cm) 72” (182.9 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 22-3/16” (56.4 cm)
To front of top grille: 24-11/16” (62.7 cm) To front of handle endcap: 27-1/4” (69.2 cm)
Cutout width 59-1/2” (151.1 cm) 65-1/2” (166.4 cm) 71-1/2” (181.6 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements (2) 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 30” Freezer 9.1 amps per unit 30” Refrigerator 5.7 amps per unit
36” Freezer 9.5 amps per unit 36” Refrigerator 6.5 amps per unit
Inlet water requirements 1/4” coppertubing inlet waterline; minimum 20 psi;
(All Freezer only) maximum 120 psi
Overall interior dimensions
30” Freezer 15.9 cu. ft. (450 liters) 30” Refrigerator 18.2 cu. ft. (516 liters) 36” Freezer 19.1 cu. ft. (541 liters) 36” Refrigerator 22.8 cu. ft. (646 liters)
Approximate shipping weight 30”- Freezer 530 lbs. (238.5 kg) each; Refrigerator 505 lbs. (227.3 kg) each
36”- Freezer 585 lbs. (263.3 kg) each; Refrigerator 570 lbs. (256.5 kg) each
2
4
(
61
.0
c
m)
1”
(2.
54
cm)
B
et
wee
n Uni
ts
3
5
(8
8
.9
c
m
)
36
(
9
1
.
5 c
m
)
9
5
/
32
(23
.
3
c
m)
8
2
3
/
4
(2
1
0.2 c
m
)
m
in
.
t
o
84–
1/
16
(21
3.
5
cm
)
m
ax
.
2
0
3
/
4
(5
2
.7
c
m
)
2
3
3
/
8
(5
9.4
c
m
)
2
9”
(7
3
.7 cm)
7
5
–1
5
/1
6
(1
9
2 .
9 c
m
)
3–1
9/
3
2
(
9.
1
c
m
)
30
(
76
.
2 c
m
)
2
6–
1/2
(
67
.
3
c
m
)
Dimensions
17
24”
(61
.0
cm
)
1”
(2.5
4 c
m)
Bet
ween
Un
its
9–5
/32”
(23
.3
c
m)
82–
3/
4
(
2
1
0
.2
cm)
mi
n
.
to
84
1
/
1
6”
(
2
1
3.5 c
m)
m
a
x
.
20–
3/4”
(52
.7
c
m)
23–
3/
8
(59
.4
cm)
7
5–
1
5
/
1
6
(1
9
2
.
9
c
m
)
3
–1
9
/
3
2
(
9
.
1
c
m
)
2
9
(73
.7 c
m
)
2
9
(73
.7
c
m
)
3
0
(
7
6
.
2 c
m
)
30
(
76
.
2 cm
)
2
6
1/
2
(
67
.
3
cm
)
Dimensions
16
Dual 30” Professional Integrated Dual 30” & 36” Professional Integrated
Specifications
19
24”
(61
.0
cm
)
1”
(2.54
c
m)
Bet
wee
n uni
ts
35”
(
88
.
9
c
m
)
3
5
(
8
8
.
9
c
m
)
3
6
(
91
.
5 c
m)
36
(
9
1
.
5
cm
)
9–5/
32”
(23
.3
c
m)
82–
3/4”
(
21
0
.2
c
m
)
m
in
.
to
8
4–
1/1
6”
(
21
3.5 c
m
)
ma
x
.
20–
3/
4
(52
.7
cm)
23–
3/8”
(59
.4
cm)
75–
15/
16”
(19
2 .
9 c
m
)
3
–1
9
/3
2
(
9
.1
cm
)
2
6–
1/2
(
67
.
3
cm
)
Dimensions
18
Dual Professional Integrated
Description (2) 30” Units (1) 36” & (1) 30” Unit (2) 36” Units
O
verall width 60” (152.4 cm) 66” (167.6 cm) 72” (182.9 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8” (59.4 cm)
To front of top grille: 24” (61.0 cm) To front of handle endcap: 26-1/2” (67.3 cm)
Cutout width 60” (152.4 cm) 66” (167.6 cm) 72” (182.9 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements (2) 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 30” Freezer 9.1 amps per unit 30” Refrigerator 5.7 ampsper unit
36” Freezer 9.5 amps per unit 36” Refrigerator 6.5 amps per unit
Inlet water requirements 1/4” coppertubing inlet waterline; minimum 20 psi;
(All Freezer only) maximum 120 psi
Overall interior dimensions
30” Freezer 15.9 cu. ft. (450 liters) 30” Refrigerator 18.2 cu. ft. (516 liters) 36” Freezer 19.1 cu. ft. (541 liters) 36” Refrigerator 22.8 cu. ft. (646 liters)
Approximate shipping weight 30”- Freezer 530 lbs. (238.5 kg) each; Refrigerator 505 lbs. (227.3 kg) each
36”- Freezer 585 lbs. (263.3 kg) each; Refrigerator 570 lbs. (256.5 kg) each
Dual 36” Professional Integrated
7
9–
3/8”
(2
0
1
.6
c
m)
mi
n.
t
o b
ot
t
o
m
of
a
nt
i
-
t
i
p
b
o
a
rd
8
0–
1/2”
(20
4.6 c
m)
ma
x.
t
o b
ot
t
o
m
of
a
nt
i
-
t
i
p
b
o
a
rd
One 2”x 4” mounting board per unit
1–1/2” (3.8 cm) x 3–1/2” (8.9 cm)
Two 2”x 4” mounting boards per unit
3” (7.6 cm) x 3–1/2” (8.9 cm)
Note: If unit is installed deeper than
24” (61.0 cm), then shim behind the anti-tip
bracket by the difference.
Note: If unit is installed deeper than
24” (61.0 cm), then shim behind the anti-tip
bracket by the difference.
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
Note: Top of unit must be placed firmly under anti-tip board.
Professional Anti-Tip Location
Professional Integrated Anti-Tip Location
2
3
(
5
8
.
4
c
m)
3–1
/2”
(
8
.
9
c
m)
3
(
7
.
6 c
m)
2
3
(5
8
.
4
c
m)
23”
(
58
.
4
cm)
3
1
/2
(
8
.
9
c
m)
1
–1
/
2
(3.
8
c
m
)
2
3”
(58
.
4 c
m)
Anti-Tip Dimensions
21
9
(
22.
9 c
m)
73–3/
8”
(
18
6.4 c
m
)
82–
7/8”
(2
1
0.5 c
m
)
mi
n.
an
t
i
-
t
i
p
b
oar
d &
openin
g h
ei
g
ht
84–1/16
(
21
3
.
5
c
m
)
m
i
n
.
a
nt
i
-
t
i
p
b
o
a
r
d
&
ope
n
in
g h
e
ig
h
t
59
1/2
(15
1.1 c
m
)
60”
(152
.4
cm)
Pr
o
f
es
sio
n
a
l
In
teg
rat
e
d
Mod
el
s
On
ly
2
4
(
6
1
.0
c
m
)
Electric Outlet Location
Water Line Entry Area
Note: Cutout opening shown with All Freezer model on left.
Reverse water line entry if All Freezer model is on right.
59
1/
2”
(
151. 1
c
m
)
60”
(15
2.4
cm
)
P
r
o
fe
s
si
o
n
al
I
n
t
e
g
rate
d M
ode
l
s
On
l
y
6–3
/
4”
(
17
.
1
c
m
)
7–5
/
8”
(19
.
4
c
m
)
3”
(7.6
cm
)
5/8
(1
.5
c
m
)
5/8
(1.
5
cm
)
10–
1/2
(
26
.
7
c
m)
5/8
(1.
5
c
m
)
10–3/4”
(
27. 3 c
m
)
3
–5
/
8”
(
9.
2 c
m
)
Opt
io
nal
fl
oor
wat
er
lin
e
e
ntr
y
1
(2
.
5
c
m
)
S
e
e
A
n
t
i-
T
ip
b
o
a
r
d
i
n
s
t
a
l
l
a
t
i
on
6
(1
5
.
2
c
m)
9
(2
2
.
9
c
m)
Cutout Dimensions
20
Dual 30” Professional & Professional Integrated
Dual 30” Professional & Professional Integrated
7
9–
3/8”
(2
0
1
.6
c
m)
mi
n
.
t
o
b
o
t
t
o
m
o
f
a
nt
i
-
t
i
p
b
o
a
rd
8
0–
1/2”
(20
4.6 c
m)
ma
x.
t
o
b
o
t
t
o
m
o
f
a
nt
i
-
t
i
p
b
o
a
rd
Note: If unit is installed deeper than
24” (61.0 cm), then shim behind the mounting
boards by the difference.
Two 2”x 4” mounting boards per unit
3” (7.6 cm) x 3 1/2” (8.9 cm)
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
Note: Top of unit must be placed firmly under anti-tip board.
Note: Dimensions shown for 36” AF/AR model on the left.
Reverse mounting boards if units are installed on the right.
Professional Anti-Tip Location
Note: If unit is installed deeper than
24” (61.0 cm), then shim behind the mounting
boards by the difference.
One 2”x 4” mounting board per unit
1–1/2” (3.8 cm) x 3–1/2” (8.9 cm)
Professional Integrated Anti-Tip Location
2
9
(
7
3
.
7
c
m)
3
1
/
2
(
8.
9
c
m
)
3”
(
7
.
6 c
m
)
2
3
(
58.
4
c
m)
2
9
(7
3
.7
c
m)
3–1
/2
(8
.
9
c
m)
1
–1
/2
(3.
8 c
m
)
2
3
(58.
4 c
m)
Anti-Tip Dimensions
23
9”
(2
2
.9
c
m
)
73–3/
8”
(
18
6
.4
c
m)
8
2
7
/
8
(2
1
0
.5
c
m)
min.
ant
i-t
ip
b
oa
r
d
&
ope
n
i
n
g
h
e
ig
h
t
84–1/
1
6”
(
21
3.
5
cm)
min
.
a
nti
-
t
i
p
b
o
a
r
d
&
o
p
e
ni
ng
he
i
gh
t
6
5
1
/2
(
1
6
6
.4
c
m
)
6
6
(1
67
.6
cm)
Pr
o
f
es
sio
n
a
l
In
teg
ra
t
ed
Mod
els
On
ly
2
4
(
6
1
.0
c
m
)
Electric Outlet Location
Water Line Entry Area
Note: Cutout opening shown with All Freezer model on left.
Reverse water line entry if All Freezer model is on right.
65–1/
2”
(
16
6.
4
cm
)
6
6
(1
6
7
.
6
c
m
)
Pro
fes
si
o
na
l
Int
eg
r
a
t
ed
Mo
d
e
l
s
O
n
l
y
6–3
/
4”
(
17
.
1
c
m
)
7–5
/
8”
(19
.
4
c
m
)
3”
(
7.6 cm
)
5/8
(1
.5
c
m
)
5/8
(1.
5
cm
)
10–
1/2
(
26
.
7
c
m)
5/8
(1.
5
c
m
)
10–3/4”
(
27. 3 c
m
)
3
–5
/
8”
(
9.
2 c
m
)
Opt
io
nal
fl
oor
wat
er
lin
e
e
ntr
y
1
(2
.
5
c
m
)
S
e
e
A
n
t
i-
T
ip
b
o
a
r
d
i
n
s
t
a
l
l
a
t
i
on
6
(1
5
.
2
c
m)
9
(2
2
.
9
c
m)
Cutout Dimensions
22
Dual 30” & 36” Professional & Professional Integrated
Dual 30” & 36” Professional & Professional Integrated
7
9–
3/8”
(2
0
1
.6
c
m)
mi
n
.
t
o
b
o
t
t
o
m
o
f
a
nt
i
-
t
i
p
bo
a
rd
8
0–
1/2”
(20
4.6 c
m)
ma
x.
t
o
b
o
t
t
o
m
o
f
a
nt
i
-
t
i
p
bo
a
rd
Note: If unit is installed deeper than
24” (61.0 cm), then shim behind the mounting
boards by the difference.
Note: If unit is installed deeper than
24” (61.0 cm), then shim behind the mounting
boards by the difference.
One 2”x 4” mounting board per unit
1–1/2” (3.8 cm) x 3–1/2” (8.9 cm)
Two 2”x 4” mounting boards per unit
3” (7.6 cm) x 3–1/2” (8.9 cm)
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
Note: Top of unit must be placed firmly under anti-tip board.
Professional Anti-Tip Location
Professional Integrated Anti-Tip Location
2
9
(7
3
.7
c
m
)
3–
1/
2”
(8
.9
c
m
)
3”
(7.6
cm
)
29”
(7
3
.7
cm)
29”
(73
.7 c
m
)
3–1/
2
(
8
.
9
c
m
)
1
–1
/
2
(3.8
c
m
)
2
9
(73
.7
c
m
)
Anti-Tip Dimensions
25
9”
(2
2
.9
c
m
)
73–3/
8”
(
18
6
.4
c
m)
8
2
7
/
8
(2
1
0
.5
c
m)
min.
ant
i-t
ip
b
oa
r
d
&
ope
n
i
n
g
h
e
ig
h
t
84–1/
1
6”
(
21
3.
5
cm)
min
.
a
nti
-
t
i
p
b
o
a
r
d
&
o
p
e
ni
ng
he
i
gh
t
7
1
1
/2
(
1
8
1
.6
c
m
)
72”
(182
.8
cm
)
Pr
o
f
es
sio
n
a
l
In
teg
rat
ed
Mod
el
s
On
ly
2
4
(
6
1
.0
c
m
)
Electric Outlet Location
Water Line Entry Area
Note: Cutout opening shown with All Freezer model on left.
Reverse water line entry if All Freezer model is on right.
71–1
/2”
(
18
1.
6
cm
)
72”
(
1
8
2
.
8
cm
)
P
ro
f
e
s
sio
n
al
I
n
t
e
g
r
at
e
d
Mod
e
ls
O
n
ly
6–3
/
4”
(
17
.
1
c
m
)
7–5
/
8”
(19
.
4
c
m
)
3”
(7.6
cm
)
5/8
(1
.5
c
m
)
5/8
(1.
5
cm
)
10–
1/2
(
26
.
7
c
m)
5/8
(1.
5
c
m
)
10–3/4”
(
27. 3 c
m
)
3
–5
/
8”
(
9.
2 c
m
)
Opt
io
nal
fl
oor
wat
er
lin
e
e
ntr
y
1
(2
.
5
c
m
)
S
e
e
A
n
t
i-
T
ip
b
o
a
r
d
i
n
s
t
a
l
l
a
t
i
on
6
(1
5
.
2
c
m)
9
(2
2
.
9
c
m)
Cutout Dimensions
24
Dual 36” Professional & Professional Integrated Dual 36” Professional & Professional Integrated
Top View
1–13/16”
(4.6 cm)
Space if 24” (61.0 cm)
standard cabinet
depth is used
Door
24”
(61.0 cm)
Standard cabinet depth
Wall
3/4”
(1.9 cm)
Full end panel
2–1/2”
(6.4 cm) Offset
Partial overlay
cabinet door
Cabinet Information (Professional)
27
To p View
To p View
1–13/16”
(4.6 cm)
Space if 24” (61.0 cm)
standard cabinet
depth is used
Door
24”
(61.0 cm) Standard cabinet depth
Wall
3/4”
(1.9 cm)
Full end panel
2–1/2”
(6.4 cm) Offset
Countertop overhang
Door
Wall
1–13/16”
(4.6 cm) Space if 24” (61.0 cm) standard cabinet
depth is used
3/4”
(1.9 cm)
Full end panel
24”
(61.0 cm)
Standard
cabinet depth
2–1/2”
(6.4 cm) Offset
5–16”
(0.8 cm)
Cabinet Information (Professional)
26
Professional models fit “semi-flush” in standard 24” (61.0 cm) deep cabinet openings. The door face protrudes 2-1/2” (6.4 cm) from the cabinet face. The handle protrudes an additional 2-1/2” (6.4 cm) into the room.
Professional models fit “semi-flush” in standard 24” (61.0 cm) deep cabinet openings. The door face protrudes 2-1/2” (6.4 cm) from the cabinet face. The handle protrudes an additional 2-1/2” (6.4 cm) into the room.
Top View
Overlapping cabinet doors
To p View
Flush mount cabinet doors
Door
24
(
61
.
0
cm
)
Stand
ard
cabi
net
de
p
t
h
24-3/4”
(62.9 cm)
Wall
3/4”
(1.9 cm)
Full end panel
3/4”
(1.9 cm)
Space if 24”
(61.0 cm) standard
cabinet depth is used
Flush
Cabinet door
Door
Wall
3/4”
(1.9 cm)
Full end panel
1”
(2.5 cm)
Space if 25”
(63.5 cm) standard
cabinet depth is used
Flush
25”
(63.5 cm)
Cabinet depth
Cabinet door
Cabinet Information (Professional Integrated)
29
To p View
To p View
Door
24”
(61.0 cm)
Standard
cabinet
depth
25”
(63.5 cm)
countertop
depth
Wall
3/4”
(1.9 cm)
Full end panel
Door
Wall
1”
(2.5 cm)
Space if 25” (63.5 cm)
standard cabinet
depth is used
3/4”
(1.9 cm)
Full end panel
25”
(63.5 cm)
Flush
1”
(2.5 cm)
Space if 25” (63.5 cm)
standard cabinet depth
is used
Flush
Cabinet Information (Professional Integrated)
28
Professional Integrated models fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except the handle protrudes 2-1/2” (6.4 cm) into the room.
Professional Integrated models fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except the handle protrudes 2-1/2” (6.4 cm) into the room.
Specifications
31
24”
(
61
.0
c
m)
35”
(8
8
.9
cm)
75–
15/
16”
(1
9
2
.9
cm
)
3–1/
2”
(
8
.
9
c
m
)
9
5
/3
2
(23
.3
c
m)
82–
3/4
(21
0
.2
c
m
)
m
in
.
to
8
4
1/1
6”
(21
3
.5
cm
)
m
a
x
.
20–
3/4
(
52
.7
c
m)
23–
3/8
(59
.4
c
m
)
24”
(61
.0
cm)
29”
(7
3
.7
c
m
)
7
5
1
5
/
1
6
(
19
2.
9
cm
)
3–
1/
2”
(
8
.
9
c
m
)
9
5
/
3
2
(
2
3.3
cm
)
82
3
/4
(21
0
.2
c
m
)
m
in
.
t
o
8
4
1/1
6
(21
3
.5
c
m
)
max
.
20–
3
/4
(
52
.7 c
m)
23
3/8
(59
.4
c
m)
26
(66.
0
c
m)
26”
(
66.
0 c
m)
30”
(7
6.2
c
m
)
36”
(9
1
.5
cm)
Dimensions
30
30” Designer
36” Designer
30” Designer
Description DDFB304 DDRB304
O
verall width 30” (76.2 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8” (59.4 cm)
To front of top grille: 24” (61.0 cm) To front of handle: 26” (66.0 cm)
Cutout width 30” (76.2 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.1 amps 5.7 amps Inlet water requirements 1/4” copper tubing inlet
waterline; minimum 20 psi; N/A
maximum 120 psi
Overall interior dimensions Total capacity 15.9 cu. ft. (450 liters) 18.2 cu. ft. (516 liters) Approximate shipping weight 525 lbs. (236.3 kg) 495 lbs. (222.8 kg)
36” Designer
Description DDFB364 DDRB364
Overall width 36” (91.5 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8” (59.4 cm)
To front of top grille: 24” (61.0 cm) To front of handle: 26” (66.0 cm)
Cutout width 36” (91.5 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.5 amps 6.5 amps Inlet water requirements 1/4” copper tubing inlet
waterline; minimum 20 psi; N/A
maximum 120 psi
Overall interior dimensions Total capacity 19.1 cu. ft. (541 liters) 22.8 cu. ft. (646 liters) Approximate shipping weight 580 lbs. (261.0 kg) 555 lbs. (249.8 kg)
One 2”x 4” mounting board
1–1/2” (3.8 cm) x 3–1/2” (8.9 cm)
Note: If unit is installed deeper than 24” (61.0 cm), then shim
behind the mounting boards by the difference.
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
Note: Top of unit must be placed firmly under anti-tip board.
Anti-Tip Location
7
9–
3/8”
(2
0
1
.6
c
m)
mi
n.
t
o
b
o
t
t
o
m
o
f
a
nti
-
t
i
p
bo
a
rd
8
0–
1/2”
(20
4.6 c
m)
ma
x.
t
o
b
o
t
t
o
m
o
f
a
nti
-
t
i
p
bo
a
rd
23”
(
5
8
.4 cm
)
3
1
/
2
(8.
9 c
m
)
1
1
/2
(3.
8 c
m)
Anti-Tip Dimensions
33
9”
(
22
.
9
c
m)
73–
3/
8”
(18
6.4 c
m
)
8
2–
7/8”
(2
1
0
.5
c
m)
mi
n
.
a
n
t
i
-
t
ip
b
o
ar
d
&
o
p
en
ing
he
igh
t
84–1
/16
(
2
1
3
.
5
c
m)
mi
n
.
an
t
i-t
ip
boa
r
d
&
ope
n
in
g h
e
ig
h
t
3
0”
(7
6.2 c
m
)
2
4”
(61
.
0 c
m
)
Electric Outlet Location
Water Line Entry Area
Note: Shown for All Freezer Only
30”
(
7
6
.2
c
m
)
6–3/
4”
(
17
.1
cm
)
7–5/
8”
(
1
9
.4
c
m)
3”
(7.6
cm
)
5/8
(1.
5 c
m)
5/8
(1.
5 c
m)
10–1
/2”
(26
.7
cm)
5
/8
(1.5
cm)
10–3/
4”
(27
.3
cm)
1”
(
2.
5
c
m
)
3–5
/8”
(9.
2 c
m)
Op
t
ion
al f
loo
r
wat
er
lin
e e
ntr
y
S
e
e
A
n
t
i-
T
ip b
o
a
r
d
i
n
st
a
l
l
a
t
ion
6
(1
5
.
2
c
m)
9
(2
2
.
9
c
m)
Cutout Dimensions
32
30” Designer
30” Designer
One 2”x 4” mounting board
1–1/2” (3.8 cm) x 3–1/2” (8.9 cm)
Note: If unit is installed deeper than 24” (61.0 cm), then shim
behind the mounting boards by the difference.
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
Note: Top of unit must be placed firmly under anti-tip board.
Anti-Tip Location
7
9–
3/8”
(2
0
1
.6
c
m)
mi
n
.
t
o
b
o
t
t
o
m
o
f
a
nt
i
-
t
i
p
bo
a
rd
8
0–
1/2”
(20
4.6 c
m)
ma
x.
t
o
b
o
t
t
o
m
o
f
a
nt
i
-
t
i
p
bo
a
rd
29”
(
7
3
.7 cm
)
3
1
/
2
(8.
9 c
m
)
1
1
/2
(3.
8 c
m)
Anti-Tip Dimensions
35
9”
(
22
.
9
c
m)
73–
3/
8”
(18
6.4 c
m)
8
2–
7/8”
(2
1
0
.5
c
m)
mi
n
.
a
n
t
i
-
t
ip
b
o
ar
d
&
o
p
en
ing
he
igh
t
84–1
/16
(
2
1
3
.
5
c
m)
mi
n
.
an
t
i-t
ip
boa
r
d
&
ope
n
in
g h
e
ig
h
t
3
6”
(9
1
.5 c
m
)
2
4”
(61
.
0 c
m
)
Electric Outlet Location
Water Line Entry Area
Note: Shown for All Freezer Only
36”
(
9
1
.5
c
m
)
6–3/
4”
(
17
.1
cm
)
7–5/
8”
(
1
9
.4
c
m)
3”
(7.6
cm
)
5/8
(1.
5 c
m)
5/8
(1.
5 c
m)
10–1
/2”
(26
.7
cm)
5
/8
(1.5
cm
)
10–3/
4”
(27
.3
cm)
1”
(
2.
5
cm
)
3–5
/8”
(9.
2 c
m)
Op
t
ion
al f
loo
r
wat
er
lin
e e
ntr
y
S
e
e
A
n
t
i-
T
ip b
o
a
r
d
i
n
st
a
l
l
a
t
ion
6
(1
5
.
2
c
m)
9
(2
2
.
9
c
m)
Cutout Dimensions
34
36” Designer
36” Designer
2
4
(
61
.0
c
m)
1”
(2.
54
cm)
Bet
wee
n
u
ni
t
s
3
5”
(
88
.
9
c
m
)
9
5
/
3
2
(23
.
3
c
m)
8
2
3
/
4
(2
1
0.2 c
m
)
m
in
.
t
o
84
1/
16
(21
3.
5
cm
)
m
ax
.
2
0
–3
/
4
(
52
.
7
c
m
)
2
3
3
/
8
(
59
.
4
c
m
)
2
9”
(7
3
.7 cm)
7
5
–1
5
/1
6
(1
9
2 .
9 c
m
)
3–
1/
2
(
8.
9 c
m
)
26
(
6
6
.
0
c
m)
3
6”
(
91
.
5
c
m)
3
0
(7
6
.2
cm
)
Dimensions
37
24”
(61
.
0 c
m
)
1”
(2.5
4 c
m)
Bet
ween
Un
its
9–
5
/32”
(23
.3
c
m)
82–
3/
4
(
2
1
0
.2
cm)
mi
n
.
to
84
1
/
1
6”
(
2
1
3.5 c
m)
m
a
x
.
20–
3
/4”
(52
.7
c
m)
23–
3/
8
(59
.
4
cm)
7
5–
15
/
1
6
(1
9
2
.
9
c
m
)
3
1/2
(
8
.
9
c
m
)
2
9
(73
.7 c
m
)
29
(73
.7
c
m
)
2
6”
(
6
6
.
0 c
m)
3
0
(76
.2
c
m
)
3
0”
(76
.2
c
m
)
Dimensions
36
Dual 30” Designer
Dual 30” & 36” Designer
Specifications
39
2
4”
(61
.0 cm
)
1”
(2.54 c
m)
Bet
wee
n uni
ts
35”
(
88
.
9
c
m
)
3
5
(
8
8
.
9
c
m
)
9
5
/
32
(23
.3
c
m)
82–
3/4”
(
21
0
.2
c
m
)
m
in
.
to
8
4–
1/1
6”
(
21
3.5 c
m
)
ma
x
.
20–
3/4
(52
.7
cm
)
23–3
/8”
(59
.4
cm)
75–
15/
16”
(19
2 .
9 c
m
)
3
–1
/2
(
8
.9
cm
)
2
6”
(
6
6
.
0 c
m)
3
6
(
9
1
.4
c
m
)
36”
(
91
.
4
c
m
)
Dimensions
38
Dual 36” Designer
Dual Designer
Description (2) 30” Units (1) 36” & (1) 30” Unit (2) 36” Units
O
verall width 60” (152.4 cm) 66” (167.6 cm) 72” (182.9 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8” (59.4 cm)
To front of top grille: 24” (61.0 cm) To front of handle: 26” (66.0 cm)
Cutout width 60” (152.4 cm) 66” (167.6 cm) 72” (182.9 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements (2) 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 30” Freezer 9.1 amps per unit 30” Refrigerator 5.7 ampsper unit
36” Freezer 9.5 amps per unit 36” Refrigerator 6.5 amps per unit
Inlet water requirements 1/4” coppertubing inlet waterline; minimum 20 psi;
(All Freezer only) maximum 120 psi
Overall interior dimensions
30” Freezer 15.9 cu. ft. (450 liters) 30” Refrigerator 18.2 cu. ft. (516 liters) 36” Freezer 19.1 cu. ft. (541 liters) 36” Refrigerator 22.8 cu. ft. (646 liters)
Approximate shipping weight 30” Freezer 525 lbs. (236.3 kg) each; Refrigerator 495 lbs. (222.8 kg) each
36” Freezer 580 lbs. (261.0 kg) each; Refrigerator 555 lbs. (249.8 kg) each
7
9–
3/8”
(2
0
1
.6
c
m)
mi
n.
t
o
b
o
t
t
o
m
o
f
a
nt
i
-
t
i
p
b
o
a
rd
8
0–
1/2”
(20
4.6 c
m)
ma
x.
t
o
b
o
t
t
o
m
o
f
a
nt
i
-
t
i
p
b
o
a
rd
One 2”x 4” mounting board per unit
1–1/2” (3.8 cm) x 3–1/2” (8.9 cm)
Note: If unit is installed deeper than 24” (61.0 cm), then shim
behind the mounting boards by the difference.
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
Note: Top of unit must be placed firmly under anti-tip board.
Anti-Tip Location
23”
(
5
8
.4 cm
)
3
1
/2”
(8.
9 c
m
)
1–
1
/
2”
(3.
8 c
m)
23”
(
5
8
.4 cm
)
Anti-Tip Dimensions
41
9”
(2
2
.9
c
m
)
73–3/
8”
(
18
6
.4
c
m)
8
2
7
/
8
(2
1
0
.5
c
m)
min.
ant
i-t
ip
b
oa
r
d
&
ope
n
i
n
g
h
e
ig
h
t
84–1/
1
6”
(
21
3.
5
cm)
min
.
a
nti
-
t
i
p
b
o
a
r
d
&
o
p
e
ni
ng
he
i
gh
t
6
0
(1
5
2
.4
c
m
)
2
4
(
6
1
.0
c
m
)
Electric Outlet Location
Water Line Entry Area
Note: Cutout opening shown with All Freezer model on left.
Reverse water line entry if All Freezer model is on right.
60”
(
15
2.
4
cm
)
6–3
/
4”
(
17
.
1
c
m
)
7–5
/
8”
(19
.
4
c
m
)
3”
(7.6
cm
)
5/8
(1
.5
c
m
)
5/8
(1.
5
cm
)
10–
1/2
(
26
.
7
c
m)
5/8
(1.
5
c
m
)
10–3/4”
(
27. 3 c
m
)
3
–5
/
8”
(
9.
2 c
m
)
Optio
nal
fl
oo
r
wat
er
lin
e
ent
ry
1
(2
.
5
c
m
)
S
e
e
A
n
t
i-
T
ip
b
o
a
r
d
i
n
s
t
a
l
l
a
t
i
on
6
(1
5
.
2
c
m)
9
(2
2
.
9
c
m)
Cutout Dimensions
40
Dual 30” Designer
Dual 30” Designer
7
9–
3/8”
(2
0
1
.6
c
m)
mi
n
.
t
o
b
o
t
t
o
m
o
f
a
nt
i
-
t
i
p
b
o
a
rd
8
0–
1/2”
(20
4.6 c
m)
ma
x.
t
o
b
o
t
t
o
m
o
f
a
nt
i
-
t
i
p
b
o
a
rd
One 2”x 4” mounting board per unit
1–1/2” (3.8 cm) x 3–1/2” (8.9 cm)
Note: If unit is installed deeper than 24” (61.0 cm), then shim
behind the mounting boards by the difference.
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
Note: Top of unit must be placed firmly under anti-tip board.
Note: Dimensions shown for 36” AF/AR model on the left.
Reverse mounting boards if units are installed on the right.
Anti-Tip Location
29”
(
7
3
.7 cm
)
3
1
/2”
(8.
9 c
m
)
1–
1
/
2”
(3.
8 c
m)
23”
(
5
8
.4 cm
)
Anti-Tip Dimensions
43
9”
(2
2
.9
c
m
)
73–3/
8”
(
18
6
.4
c
m)
8
2
7
/
8
(2
1
0
.5
c
m)
min.
ant
i-t
ip
b
oa
r
d
&
ope
n
i
n
g
h
e
ig
h
t
84–1/
1
6”
(
21
3.
5
cm)
min
.
a
nti
-
t
i
p
b
o
a
r
d
&
o
p
e
ni
ng
he
i
gh
t
6
6
(
1
6
7
.6
c
m
)
2
4
(
6
1
.0
c
m
)
Electric Outlet Location
Water Line Entry Area
Note: Cutout opening shown with All Freezer model on left.
Reverse water line entry if All Freezer model is on right.
66”
(
16
7.
6
cm
)
6–3
/
4”
(
17
.
1
c
m
)
7–5
/
8”
(19
.
4
c
m
)
3”
(7.6
cm
)
5/8
(1
.5
c
m
)
5/8
(1.
5
cm
)
10–
1/2
(
26
.
7
c
m)
5/8
(1.
5
c
m
)
10–3/4”
(
27. 3 c
m
)
3
–5
/
8”
(
9.
2 c
m
)
Optio
nal
fl
oo
r
wat
er
lin
e
ent
ry
1
(2
.
5
c
m
)
S
e
e
A
n
t
i-
T
ip
b
o
a
r
d
i
n
s
t
a
l
l
a
t
i
on
6
(1
5
.
2
c
m)
9
(2
2
.
9
c
m)
Cutout Dimensions
42
Dual 30” & 36” Designer
Dual 30” & 36” Designer
7
9–
3/8”
(2
0
1
.6
c
m)
mi
n.
t
o b
ot
t
o
m
of
a
nt
i
-
t
i
p
bo
a
rd
8
0–
1/2”
(20
4.6 c
m)
ma
x.
t
o b
ot
t
o
m
of
a
nt
i
-
t
i
p
bo
a
rd
One 2”x 4” mounting board per unit
1–1/2” (3.8 cm) x 3–1/2” (8.9 cm)
Note: If unit is installed deeper than 24” (61.0 cm), then shim
behind the mounting boards by the difference.
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
Note: Top of unit must be placed firmly under anti-tip board.
Anti-Tip Location
29”
(
7
3
.7 cm
)
3
1
/2”
(8.
9 c
m
)
1–
1
/
2”
(3.
8 c
m)
29”
(
7
3
.7 cm
)
Anti-Tip Dimensions
45
9”
(2
2
.9
c
m
)
73–3/
8”
(
18
6
.4
c
m)
8
2
7
/
8
(2
1
0
.5
c
m)
m
i
n.
ant
i-t
ip
b
oa
r
d
&
ope
n
i
n
g
h
e
ig
h
t
84–1/
1
6”
(
21
3.
5
cm)
min
.
a
nti
-
t
i
p
b
o
a
rd
&
o
p
e
ni
ng
he
i
gh
t
7
2
(
1
8
2
.9
c
m
)
2
4
(
6
1
.0
c
m
)
Electric Outlet Location
Water Line Entry Area
Note: Cutout opening shown with All Freezer model on left.
Reverse water line entry if All Freezer model is on right.
72”
(
18
2.
9
cm
)
6–3
/
4”
(
17
.
1
c
m
)
7–5
/
8”
(19
.
4
c
m
)
3”
(7.6
cm
)
5/8
(1
.5
c
m
)
5/8
(1.
5
cm
)
10–
1/2
(
26
.
7
c
m)
5/8
(1.
5
c
m
)
10–3/4”
(
27. 3 c
m
)
3
–5
/
8”
(
9.
2 c
m
)
Optio
nal
fl
oo
r
wat
er
lin
e
ent
ry
1
(2
.
5
c
m
)
S
e
e
A
n
t
i-
T
ip
b
o
a
r
d
i
n
s
t
a
l
l
a
t
i
on
6
(1
5
.
2
c
m)
9
(2
2
.
9
c
m)
Cutout Dimensions
44
Dual 36” Designer
Dual 36” Designer
To p View
Overlapping cabinet doors
Top View
Flush mount cabinet doors
Door
24
(
61
.
0
cm
)
Stand
ard
cabi
net
de
p
t
h
24-3/4”
(62.9 cm)
Wall
3/4”
(1.9 cm)
Full end panel
3/4”
(1.9 cm)
Space if 24” (63.5 cm)
standard cabinet
depth is used
Flush
Cabinet door
Door
Wall
3/4”
(1.9 cm)
Full end panel
1”
(2.5 cm)
Space if 25” (63.5 cm)
standard cabinet
depth is used
Flush
25”
(63.5 cm)
cabinet depth
Cabinet door
Cabinet Information (Designer)
47
To p View
To p View
Door
24”
(61.0 cm)
Standard
cabinet
depth
25”
(63.5 cm)
Countertop
depth
Wall
3/4”
(1.9 cm)
Full end panel
Door
Wall
1”
(2.5 cm)
Space if 25” (63.5 cm)
standard cabinet
depth is used
3/4”
(1.9 cm)
Full end panel
25”
(63.5 cm)
Flush
1”
(2.5 cm)
Space if 25” (63.5 cm)
standard cabinet
depth is used
Flush
Cabinet Information (Designer)
46
Designer models fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except 2” (5.1 cm) curved handle depth.
Designer models fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except 2” (5.1 cm) curved handle depth.
3/4”
(1.9 cm)
End panel
1”
(2.5 cm)
1/4”
(
0.6 cm)
Z-Bracket
2
1
-
3
/
4
(55
.2 c
m
)
2
1
-
3
/
4
(55
.2 c
m
)
2
4
(
6
1
.
0 c
m)
Optional kickplate notch
Dimensions determined by cabinets
2
4
(61
.
0 c
m
)
82-7
/
8”
(21
0
.
5
c
m
)
min
.
t
o
84-1
/
1
6”
(
21
3
.
5
c
m)
max.
*
8
2
-7 /
8
(21
0
.
5
c
m
)
m
i
n
.
t
o
8
4
-1 /
1
6
(
21
3
.
5
c
m
)
m
a
x
.
*
Custom Side Panel Dimensions
(Designer & Professional Integrated)
49
3/4”
(1.9 cm)
End panel
5/32”
(0.4 cm)
3/16”
(
0.5 cm)
Back filler
panel
2
2
-7/1
6”
(
5
7
.
0
c
m)
22-7/
16
(
57
.
0
cm)
2
2-1/4
(5
6
.5
c
m)
6”
(
15
.
2
cm
)
Optional kickplate notch
Dimensions determined by cabinets
82-
7/8”
(
2
1
0
.5
cm
)
m
in.
t
o
84-
1/
1
6”
(
21
3
.5
cm
)
ma
x
.
*
8
2
-
7
/8
(
2
1
0
.5
c
m
) m
in.
to
8
4
-
1
/
16
(
21
3
.5
c
m
)
ma
x
.
*
6”
(
15
.
2
c
m)
22-1/4”
(56
.
5
cm
)
Custom Side Panel Dimensions
(Professional)
48
* Depending on how high leveling feet are raised, and cabinet enclosure height.
* Depending on how high leveling feet are raised, and cabinet enclosure height.
5150
General Information
Water Supply Requirements
Use only 1/4” (6 mm) copper tubing for water line. Do Not install copper tubing in area where temperatures drop below 35° F (1.7° C). Before attaching copper tubing to the unit, flush at least 2 quarts (1.9 L) of water through the copper tubing and into a bucket to remove any particles in the water line.
• Viking Range Corporation is not responsible for property damage due to improper installation or water connection.
• Connect 1/4” (6 mm) flexible copper tubing to household plumbing in compliance with local codes and ordinances.
• Length of copper tubing must reach from water supply connection to the unit connection with an additional length to facilitate moving the unit out of enclosure for cleaning or service. Tubing should be soft instead of rigid and ends should be free of burrs.
• Copper tubing route must be above 35° F (1.7° C) to prevent water line from freezing.
• Do not use plastic water lines from the household plumbing to the water inlet valve connection on the refrigeration unit.
• Do not use the self-piercing feature of a saddle valve. The hole made by the
piercing lance is too small for the water flow rate required by the ice maker.
• If saddle valve is not used, place a
separate shut-off valve in an easily accessible location between water supply and the unit. Do not locate shut-off valve behind the unit.
• The installation of Viking units with a
reverse osmosis system is acceptable
as long as the water pressure remains within the allowable PSI as stated below.
It is important to note that with many reverse osmosis systems, the pressure starts off high, but then it decreases as the water level of the reverse osmosis storage area drops. This must be considered when checking the water pressure coming into the unit.
• Connect a vertical or horizontal 1/2”
(1.2 cm) to 1-1/4” (3.2 cm) COLD water line near water area.
• Run water line through the floor, back, or
side wall. Tubing should lay flat on floor underneath the unit. Clamp tubing to wall or floor.
• Water pressure must be greater than 20 psi
and less than 120 psi on non-dispensers and greater than 35 psi and less than 120 psi on dispensers.
General Information
Area Requirements
Verify the following:
• Unit can fit into residence and can be moved around corners and through doorways.
• Floors can support unit’s weight plus food weight (approximately 1200 pounds [540 kg] per unit).
• Rear wall is solid and is able to support two horizontally mounted 2 X 4s (included) bolted to two wall studs. The 2 X 4 board bolt heads must be flush with 2 X 4 to prevent obstruction.
• Remove anything attached to rear or side walls that can obstruct unit installation.
• Cutout dimensions are accurate.
• Electrical outlet is in correct location.
• Water line is in correct location.
• Do not install a refrigeration unit near a heat source, nor in a location where the surrounding temperature will fall below 60º F (16º C).
Electrical Requirements
It is the customer’s responsibility to:
• contact a qualified electrical installer.
• assure that the electrical installation is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70­latest edition or Canadian Electrical Code C22.1-1998 and C22.2 No. 0-M91 (or latest edition), and all local codes and ordinances. A 115 volt, 60-Hz, 15 amp,
fused, electrical supply is required. It is required that a separate circuit serving only this appliance be provided. This appliance is equipped with a power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong, grounding­type wall receptacle.
Do not use an extension cord.
If codes permit a separate grounding wire to be used, it is recommended that a qualified electrician deter mine that the grounding path is adequate.
DO NOT ground to a gas pipe. Check with a qualified electrician if you are not sure the appliance is properly grounded. DO NOT have a fuse in the neutral or grounding circuit.
Anti-Tip Requirements
The anti-tip boards should be fastened into position prior to moving the unit into the opening.
Note: Additional mounting boards may be required if the unit does not touch the back wall of the enclosure. To prevent unit from tipping forward, it must be secured in place with a solid soffit or wood block.
W A R N I N G
To avoid serious illness or death, donot use unit where water is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systemscertified for cyst reduction may be used on disinfectedwater that may contain filterable cysts. The contaminants or other substances removed or reduced by this water treatment system arenot necessarily in youwater.
53
1
2a
Place unit in front of cutout.
(Professional) Lift center grille louver up
and pull out.
2b
designer
3
(Designer) Pull the center grille louver up
at an angle and pull out.
Using an 8” magnetic nut driver, remove
the two 1/4” screws.
4
Remove grille assembly.
• Most of the unit’s weight is at the top. Extra care is needed when moving the unit to prevent tipping.
• Do Not remove protective film until unit is in operating position.
• All four leveling legs must contact the floor to support and stabilize the full weight.
• Do not drop unit.
• Remove exterior shipping materials prior to moving unit into home.
• Use two or more people to move and install unit. Failure to follow this instruction can result in back or other injury.
• To avoid personal injury, wear gloves when performing any installation procedure and wear eye protection when cutting metal straps.
TIP OVER HAZARD
Appliance is top heavy and tips easily when not completely installed. Keep doors closed until appliance is completely installed and secured per installation instructions. Use two or more people to move and install appliance. Failure to do so can result in death or serious injury.
Unpacking unit
1. Remove top and bottom strap.
2. Remove top cap.
3. Cut carton rear approximately 1/4” (0.6 cm) to 1” (2.5 cm) from right corner with a utility knife extended 1/4” (0.6 cm).
4. Remove carton and exterior packaging. Save cardboard shipping material to protect floor surface when installing unit. Remove anti-tip board, kickplate and door trim pieces (DF models) from rear of unit.
52
Moving Unit
Remove shipping brackets from skid byremoving 4 bolts (2 on each side) with a 1/2” deep-well socketwench and
a pair of pliers.
Note: Tilting unit is not required to remove shipping
brackets.
Slip appliance dolly between unit and skid. Only use dolly from the rear ofthe unit to remove unit from skid. After the unit is removed from the skid, a dolly can be used from either side or the backBUT NOTTHE FRONT.
Note: Use excess packaging to protect decorative trim;
also, verify that leveling legs are up (0” adjustment).
General Information
Installation
5554
54
Remove 4 side screws and remove unit top.
Loosen the 4 hinge screws. Adjustdoor.
Retighten 4 hinge screws.
Replace unit top. Replace 4 side screws.
Attach a single 2 x 4 to wall stud(refer to dimensions
page for exact location).
If needed, depending on cabinet and depth,
attach second 2 x 4 to first 2 x4.
2
1
5
Front of unit
2
1 3
6
1
2
7
8a
Wall
2 x 4
Refrigerator
8b
Wall
2 x 4
Refrigerator
Hinge Adjustment
9
3”
3”3
10a
Plug in power cord to verifyoperation.
Note: Make sure power switch and showroom switch
are in the “On” Position.
Place unit within 3” of being flush with cabinets.
Note: To avoid cabinet damage, place cardboard
between cabinets and unit. When moving unit, do not
crimp, kink or crush water supply line.
10b
11
Carefully move unit until semi flushwith cabinet
(depending on unit).
Pull supply tubing forward under unit.
Note: DO NOT use plastic water lines.
12
13
Flush water line by running two quarts of water
into a bucket. Turn water off.
Connect supply tube to water valve using
a 1/2” wrench. Note: DO NOT overtighten.
5756
Turn on water supply and check for leaks.
Lift unit off rollers to desired height and level unit using
a 5/16” head wrench.
Note: DO NOT use an electric device. Overtightening
can cause damage.
Attach positive secure self-tapping bolts to2 x 4
using a 22” extension.
Verify that drainpan is installed andaligned.
Align holes on both ends of louvered panels and insert
screws.
Using a Phillips screwdriver, attach the
kickplate to the unit and adjust to desired height.
14
15
Wall
2 x 4
Refrigerator
Screw
16
17
1
2
18
2
3
19
Kickplate Installation
3
1
2
20
1
2
21
110˚
120˚
90˚
Open refrigerator door so door stopand shoulder
screw are accessible.
Note: Shoulder screw should be in 110˚ door opening position.
Remove shoulder screw and place in90˚ or
120˚ position.
Door Stop Adjustment
Replace top air grille.
Using an 8”magnetic nut driver, replace
the two 1/4” screws.
(Professional) Replace the center grille louver.
(Designer) Replace the center grille louver.
22
23
24a
24b
designer
Final Installation
Performance Checklist
59
h Verify cabinet size.
h Verify electrical supply and water supply
(if applicable).
h Install anti-tip device(s) and verify unit is
secure.
h Position unit in cutout, level at desired
height, and secure unit.
h Plug-in unit and verify operation.
h Connect water supply (if applicable).
• Verify icemaker fill tube is properly inserted.
• Verify icemaker bailarm is down.
• Verify dispenser operation (if applicable).
h Align/square door(s).
h Verify drain pan is properly installed and
there are no leaks in water connection.
h Install kickplate.
h Remove inter nal packaging and labels
and wipe unit down.
Installer’s information:
Installer’s name:_____________________________
Installer’s company:_________________________
Date:________________________________________
58
Open door. Display should flash.
Press “ACTIVATE CONTROLS” button pad and close
door.
Note: There is a 6 minute delay before the unit starts.
25
26
61
Service & Registration
Only authorized replacement parts may be used in performing service on the appliance. Do not repair or replace any part of the appliance unless specifically recommended in the manual. All other servicing should be referred to a qualified technician.
Record the following information indicated below. You will need it if service is ever required. The serial number and model number for your appliance are located on the identification plate mounted behind the top light.
Model number
_________________________________________
Serial number
_________________________________________
Date of purchase
_________________________________________
Date installed
_________________________________________
Dealer's name
_________________________________________
Address
_________________________________________
Verify Operations
60
Control Panels
1. Press “Display On” or “Activate Controls” pad.
2. Verify unit is not in Sabbath Mode.
If in Sabbath Mode:
A. The Sabbath Mode will disable the interior lights, display (except three blue squares) and alarm.
(See picture below for visual indication of Sabbath Mode.)
To exit the Sabbath Mode:
B. Press and Hold “Display On” or “Activate Controls” and then “Display Off” for 3 seconds.
(The control will beep three times to alert the user the Sabbath Mode has been exited.)
3. Verify unit is not in Showroom Mode.
If in Showroom Mode:
A. The Showroom Mode will disable the refrigerator system but all other functions are normal.
These include lights and control. (See picture below for visual indication of Showroom Mode.)
To exit Showroom Mode:
B. Press and Hold “Display On” or “Activate Controls”; while holding, press and hold “Higher
Temp” and “Alarm Off” together. (The control will beep three times to alert the user that Showroom Mode has been exited.)
4. Press “Max Frz” and “Display Off” at the same time and hold until beeps (force start compressor).
5. All models need to be set at the fifth bar for Refrigerator and Freezer - factory setting.
ACTIVATE CONTROLS
REF
T
EMP
HIGHER
T
EMP
LOWER
T
EMP
HIDDEN B
UTTON
HIDDEN BUTTON
MAXFRZ
MAX R
EF
ALARM
O
FF
DISPLAY
O
FF
FRZ
T
EMP
HIGH T
EMP
MAX R
EF
COLDEST
..............
DOOROPEN
All Refrigerator
FRZ
TEMP
FRZ
TEMP
HIGH TEMP
MAX
REF
MAX FRZ
COLDEST
...........
DOOR OPEN
ACTIVATE
CONTROLS
FRZ
T
EMP
HIGHER
T
EMP
LOWER
T
EMP
HIDDEN B
UTTON
HIDDEN BUTTON
MAXREF
MAX F
RZ
ALARM
O
FF
DISPLAY
O
FF
FRZ
T
EMP
HIGH T
EMP
MAX R
EF
COLDEST
..............
D
OOROPEN
All Freezer
FRZ
TEMP
FRZ
TEMP
HIGH TEMP
MAX
REF
MAX FRZ
COLDEST
...........
DOOR OPEN
63
Notes Notes
62
Loading...