Viking Range 30” Professional Integrated VIFB304, 30 Professional VCFB304, 36 Professional VCFB364, 30” Professional Integrated VIRB304, 36” Professional Integrated VIFB364 Installation Manual

...
Viking Range Corporation
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information,
call 1-888-VIKING1 (845-4641)
or visit the Viking Web site at
vikingrange.com
(071508J)
Viking Installation Guide
All Refrigerator/Freezer
U
L
C
U
L
3
2
Table of Contents IMPORTANT–Please Read and Follow!
Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying voltage, frequency, wattage, amperage, and phase is attached to the product.
• To reduce the risk of fire, electric shock, or injury to persons, installation work and electrical wiring must be done by qualified people in accordance with all applicable codes and standards, including fire-rated construction.
• The installer should leave these instructions with the consumer who should retain them for local inspector’s use and for future reference.
It is your responsibility to:
• comply with installation specifications and dimensions.
• properly install unit.
• remove any moldings or decorative panels that prevent the unit from being serviced.
• make sure that you have these materials (not provided with your unit), which are necessary for proper installation:
• 1/4” (6 mm) copper tubing with shutoff valve
• 6– #8 x 3” (7.6 cm) wood screws (longer screws may be required)
• 1– Saddle valve (do not use self-piercing feature of the valve)
• assure that floor will support unit, door panels and contents (approximately 1200 pounds [540 kg]).
• provide a properly grounded electrical outlet.
• assure that location will permit appliance doors to open 90˚ minimum.
W A R N I N G
TIP OVER HAZARD
Appliance is top heavy and tips easily when not completely installed. Keep doors closed until appliance is completely installed and secured per installation instructions.
Use two or more people to move and install appliance. Failure to do so can result in death or serious injury.
W A R N I N G
ELECTRICAL SHOCK HAZARD
Disconnect power or turn power disconnect switch to OFF position before removing top grille. Failure to do so can result in death or electrical shock.
Your safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others.
All safety messages will be preceded by the safety alert symbol and the word“DANGER” or “WARNING.”These words mean:
D A N G E R
You will be killed or seriously injured if
you don’t follow instructions.
W A R N I N G
You can be killed or seriously injured if
you don’t follow instructions.
All safety messages will identify the
hazard, tell you how to reduce the chance
of injury, and tell you what can happen if
the instructions are not followed.
Most of the unit’s weight is at the top. Extra care is needed when moving the unit to prevent tipping. Use cardboard shipping material or plywood under unit until it is installed in the operating position to protect floor surface.
Warnings & Important Information
_________________________________________________________
3
Professional & Professional Integrated
Dimensions & Specifications (30” & 36” Professional) _______________________________ 4 Dimensions & Specifications (30” & 36” Professional Integrated) _____________________ 6 Cutout Dimensions (30” Professional & Professional Integrated) ______________________ 8 Anti-Tip Dimensions (30” Professional & Professional Integrated) _____________________ 9 Cutout Dimensions (36” Professional & Professional Integrated) _____________________ 10 Anti-Tip Dimensions (36” Professional & Professional Integrated) _____________________ 11 Dimensions & Specifications (Dual Professional) ____________________________________ 12 Dimensions & Specifications (Dual Professional Integrated) ___________________________16 Cutout Dimensions (Dual 30” Professional & Professional Integrated) _________________ 20 Anti-Tip Dimensions (Dual 30” Professional & Professional Integrated) ________________ 21 Cutout Dimensions (Dual 30” & 36” Professional & Professional Integrated) ___________ 22 Anti-Tip Dimensions (Dual 30” & 36” Professional & Professional Integrated) __________ 23 Cutout Dimensions (Dual 36” Professional & Professional Integrated) _________________24 Anti-Tip Dimensions (Dual 36” Professional & Professional Integrated) _________________25 Cabinet Infor mation (Professional) ________________________________________________ 26 Cabinet Infor mation (Professional Integrated) ______________________________________ 28
Designer
Dimensions & Specifications (30”& 36”) ___________________________________________ 30 Cutout Dimensions (30”)_________________________________________________________ 32 Anti-Tip (30”) ___________________________________________________________________ 33 Cutout Dimensions (36”)_________________________________________________________ 34 Anti-Tip Dimensions (36”)________________________________________________________ 35 Dimensions & Specifications (Dual)________________________________________________ 36 Cutout Dimensions (Dual 30”) ____________________________________________________ 40 Anti-Tip Dimensions (Dual 30”) ___________________________________________________ 41 Cutout Dimensions (Dual 30” & 36”) ______________________________________________ 42 Anti-Tip Dimensions (Dual 30” & 36”) _____________________________________________ 43 Cutout Dimensions (Dual 36”) ____________________________________________________ 44 Anti-Tip Dimensions (Dual 36”) ___________________________________________________ 45
Cabinet Infor mation_____________________________________________________________ 46 Custom Side Panel Dimensions (Professional) __________________________________________ 48 Custom Side Panel Dimensions (Designer & Professional Integrated) _____________________ 49 General Infor mation ________________________________________________________________ 50
Unpacking & Moving____________________________________________________________ 52 Installation_________________________________________________________________________ 53
Hinge Adjustment ______________________________________________________________ 54
Kickplate Installation ____________________________________________________________ 56
Door Stop Adjustment __________________________________________________________57
Final Installation ________________________________________________________________57 Performance Checklist ______________________________________________________________59 Control Panels _____________________________________________________________________60 Service & Registration_______________________________________________________________61
5
24–1
1
/1
6
(62
.
7
cm)
35”
(8
8
.9
cm)
75–
15/
16”
(
1
9
2
.9
cm
)
3–1
9
/
32
(
9
.1
cm
)
)
36
(
91
.
5
cm)
27–
1
/4
(
69
.2 c
m)
9
–5
/
32
(
23
.
3
c
m)
82
3
/4
(
21
0
.2
cm
)
m
in
.
to
8
4
1/1
6”
(
21
3
.
5
cm
)
m
ax
.
20–
3/4
(52
.7
c
m)
22
–3/1
6”
(5
6
.4
c
m
)
2
4–
1
1/16
(62
.7
cm
)
29”
(7
3
.7
c
m
)
7
5
1
5
/
1
6
(
19
2.
9
cm
)
3
–1
9
/32”
(
9
.
1
c
m
)
3
0
(
7
6
.
2
cm)
9
5
/
3
2
(
2
3
.3
cm
)
82
3
/4
(21
0
.2
c
m)
min
.
to
8
4
1/1
6
(21
3
.5
c
m
)
max
.
20–
3/4
(
52
.7
c
m)
22
–3/
1
6”
(56
.4
c
m)
27–
1
/4”
(69
.2
c
m)
Dimensions
4
30” Professional
36” Professional
Specifications
30” Professional
Description VCFB304 VCRB304
Overall width 30” (76.2 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 22-3/16” (56.4 cm)
To front of top grille: 24-11/16” (62.7 cm) To front of handle endcap: 27-1/4” (69.2 cm))
Cutout width 29-1/2” (74.9 cm) min. to 29-3/4” (75.6 cm) max. Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.1 amps 5.7 amps Inlet water requirements 1/4” copper tubing inlet
waterline; minimum 20 psi; N/A
maximum 120 psi
Overall interior dimensions Total capacity 15.9 cu. ft. (450 liters) 18.2 cu. ft. (516 liters) Approximate shipping weight 530 lbs. (238.5 kg) 505 lbs. (227.3 kg)
36” Professional
Description VCFB364 VCRB364
Overall width 36” (91.5 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 22-3/16” (56.4 cm)
To front of top grille: 24-11/16” (62.7 cm) To front of handle endcap: 27-1/4” (69.2 cm)
Cutout width 35-1/2” (90.2 cm) min. to 35-3/4” (90.8 cm) max. Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.5 amps 6.5 amps Inlet water requirements 1/4” copper tubing inlet
waterline; minimum 20 psi; N/A
maximum 120 psi
Overall interior dimensions Total capacity 19.1 cu. ft. (541 liters) 22.8 cu. ft. (646 liters) Approximate shipping weight 585 lbs. (263.3 kg) 570 lbs. (256.5 kg)
Specifications
7
2
4
(61
.0
cm)
35”
(88
.9
c
m)
75–
15/
16”
(
1
9
2.9 c
m
)
3
–19
/3
2
(
9
.
1
c
m
)
)
3
6
(9
1
.5
c
m
)
26–
1/2”
(
6
7
.3 c
m)
9–5
/3
2
(
23
.
3
cm)
82
3/4”
(
21
0
.
2
c
m)
m
i
n
.
t
o
84–
1
/
1
6
(
21
3
.
5
cm
)
m
ax
.
20–
3
/4
(52
.7
c
m)
23–
3
/
8
(59
.4
cm
)
2
4”
(61
.0
cm
)
2
9
(
7
3
.
7
c
m
)
7
5
1
5
/
16”
(
1
9
2.
9
c
m
)
3–
19
/3
2
(
9
.1
cm
)
3
0
(76
.2
c
m
)
9–5
/32
(
23
.
3
c
m)
82
3/
4”
(
21
0
.
2
c
m
)
m
i
n
.
t
o
84–
1
/
1
6”
(
21
3.
5
cm
)
max
.
20–
3/4
(52
.7 c
m)
23–
3/
8”
(5
9
.4
cm)
26–
1/2”
(
67
.3 c
m)
Dimensions
6
30” Professional Integrated
36” Professional Integrated
30” Professional Integrated
Description VIFB304 VIRB304
O
verall width 30” (76.2 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8” (59.4 cm)
To front of top grille: 24” (61.0 cm) To front of handle endcap: 26-1/2” (67.3 cm)
Cutout width 30” (74.9 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.1 amps 5.7 amps Inlet water requirements 1/4” copper tubing inlet
waterline; minimum 20 psi; N/A
maximum 120 psi
Overall interior dimensions Total capacity 15.9 cu. ft. (450 liters) 18.2 cu. ft. (516 liters) Approximate shipping weight 530 lbs. (238.5 kg) 505 lbs. (227.3 kg)
36” Professional Integrated
Description VIFB364 VIRB364
Overall width 36” (91.5 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8” (59.4 cm)
To front of top grille: 24” (61.0 cm) To front of handle endcap: 26-1/2” (67.3 cm)
Cutout width 36” (91.4 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.5 amps 6.5 amps Inlet water requirements 1/4” copper tubing inlet
waterline; minimum 20 psi; N/A
maximum 120 psi
Overall interior dimensions Total capacity 19.1 cu. ft. (541 liters) 22.8 cu. ft. (646 liters) Approximate shipping weight 585 lbs. (263.3 kg) 570 lbs. (256.5 kg)
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
Note: Top of unit must be placed firmly under anti-tip board.
Professional Anti-Tip Location
Professional Integrated Anti-Tip Location
NOTE: If unit is installed deeper than
24” (61.0 cm),then shim behind the mounting
board by the difference.
NOTE: If unit is installed deeper than
24” (61.0 cm), then shim behind the mounting
board by the difference.
Two 2”x 4” mounting boards
3” (7.6 cm) x 3-1/2” (8.9 cm)
One 2”x 4” mounting board
1–1/2” (3.8 cm) x 3-1/2” (8.9 cm)
7
9–
3/8”
(20
1
.6
c
m)
mi
n.
t
o b
ot
t
o
m
of
a
nti
-
t
i
p
bo
a
rd
8
0–
1/2”
(20
4.6 c
m)
ma
x.
t
o b
ot
t
o
m
of
a
nti
-
t
i
p
bo
a
rd
23”
(58
.4
c
m)
3–
1/
2
(
8
.
9
c
m
)
3
(
7
.
6
c
m
)
2
3
(5
8
.4
c
m
)
3–
1/
2
(8
.9
cm
)
1–1
/2
(3.
8 c
m)
Anti-Tip Dimensions
9
9”
(
22
.
9
c
m)
73–
3/
8”
(18
6.4 c
m)
8
2–
7/8”
(2
1
0
.5
c
m)
mi
n
.
a
n
t
i
-
t
ip
b
o
ar
d
&
o
p
en
ing
he
igh
t
84–1
/16
(
2
1
3
.
5
c
m)
mi
n
.
an
t
i-t
ip
boa
r
d
&
ope
n
in
g h
e
ig
h
t
29–1
/
2”
(7
4
.9
cm)
m
i
n.
to
29
-
3/
4
(75
.6
c
m)
max
.
3
0
(7
6
.2
cm
)
Pro
fe
s
sio
na
l
I
n
t
e
g
r
a
t
ed
M
o
d
els
Onl
y
2
4”
(61
.0 c
m
)
Electric Outlet Location
Water Line Entry Area
Note: Shown for All Freezer Only
29–1/
2”
(
7
4
.9
c
m)
6–3/
4”
(
17
.1
cm
)
7–5/
8”
(
1
9
.4
c
m)
3”
(7.6
cm
)
5/8
(1.
5 c
m)
5/
8
(1.
5 c
m)
10–1
/2”
(26
.7
cm)
5
/8
(1.5
cm)
10–3/
4”
(27
.3
cm)
1”
(
2.
5
cm
)
3–5
/8”
(9.
2 c
m)
Op
t
io
n
al f
loo
r
wa
t
er
lin
e e
ntr
y
30”
(
7
6
.2
c
m)
Pr
o
f
e
ss
io
na
l I
nte
gra
ted
Mo
del
s On
ly
S
e
e
A
n
t
i-
T
ip b
o
a
r
d
i
n
st
a
l
l
a
t
io
n
6
(1
5
.
2
c
m)
9
(2
2
.
9
c
m)
Cutout Dimensions
8
30” Professional & Professional Integrated
30” Professional & Professional Integrated
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
Note: Top of unit must be placed firmly under anti-tip board.
7
9–
3/8”
(20
1
.6
c
m)
mi
n.
t
o b
ot
t
o
m
of
a
nt
i
-
t
i
p
bo
a
rd
8
0–
1/2”
(20
4.6 c
m)
ma
x.
t
o b
ot
t
o
m
of
a
nt
i
-
t
i
p
bo
a
rd
Professional Anti-Tip Location
Professional Integrated Anti-Tip Location
NOTE: If unit is installed deeper than
24” (61.0 cm), then shim behind the mounting
board by the difference.
NOTE: If unit is installed deeper than
24” (61.0 cm), then shim behind the mounting
board by the difference.
T
wo 2”x 4” mounting boards
3” (7.6 cm) x 3-1/2” (8.9 cm)
One 2”x 4” mounting board
1–1/2” (3.8 cm) x 3–1/2” (8.9 cm)
29–
1/
2”
(74
.9
c
m)
3–
1/
2
(
8
.
9
c
m
)
3
(
7
.
6
c
m
)
2
9
1
/2”
(7
4
.9
c
m
)
3–
1/
2”
(8
.9
cm
)
1–1
/2
(3.
8 c
m)
Anti-Tip Dimensions
11
9”
(
22
.
9
c
m
)
73–
3/
8”
(18
6.4 c
m
)
8
2–
7/8”
(2
1
0
.5
c
m)
mi
n
.
a
n
t
i
-
t
ip
b
o
ar
d
&
o
p
en
ing
he
igh
t
84–1
/16
(
2
1
3
.
5
c
m)
mi
n
.
an
t
i-t
ip
boa
r
d
&
ope
n
in
g h
e
ig
h
t
35–
1/
2
(90.
2 c
m
)
m
in
.
to
3
5
-
3/
4
(90
.8
cm
) m
ax.
3
6
(9
1
.4 c
m
)
P
ro
fes
si
o
nal
Int
egr
ate
d
M
o
d
els
On
ly
2
4”
(61
.
0 c
m
)
Electric Outlet Location
Water Line Entry Area
Note: Shown for All Freezer Only
35–1/
2”
(
9
0
.2
c
m)
6–3/
4”
(
17
.1
cm)
7–5/
8”
(
1
9
.4
c
m
)
3”
(7.6
cm
)
5/8
(1.
5 c
m
)
5/
8
(1.
5 c
m)
10–1
/2”
(26
.7
cm)
5
/8
(1.
5
cm
)
10–3/
4”
(27
.3
cm)
1
(
2.
5
cm
)
3–5
/8”
(9.
2 c
m)
Op
t
io
n
al f
loo
r
wa
t
er
lin
e e
ntr
y
36”
(
9
1
.4
c
m)
Pr
o
f
ess
io
n
a
l
Int
egr
a
te
d M
o
de
l
s On
ly
S
e
e
A
n
t
i-
T
ip b
o
a
r
d
i
n
st
a
l
l
a
t
io
n
6
(1
5
.
2
c
m)
9
(2
2
.
9
c
m)
Cutout Dimensions
10
36” Professional & Professional Integrated
36” Professional & Professional Integrated
2
4
1
1
/
1
6
(
62
.7
c
m)
1”
(2.
54
cm)
Bet
wee
n U
ni
ts
3
5
(8
8
.9 c
m
)
36
(
9
1
.
5 cm
)
9
5
/
3
2
(23
.
3
c
m)
8
2
3
/
4
(2
1
0.2 c
m
)
m
in
.
t
o
84
1/
16
(21
3.
5
cm
)
m
ax
.
2
0
3
/
4
(5
2
.7
c
m
)
2
2
–3
/
1
6
(5
6
.4
c
m
)
2
9”
(7
3
.7 cm)
7
5
–1
5
/1
6
(1
9
2 .
9 c
m
)
3–1
9/
3
2
(
9.
1
c
m
)
30
(
76
.
2 c
m
)
2
7–
1/4
(
69
.
2
c
m
)
Dimensions
13
24–
11
/
16
(6
2
.7 c
m
)
1”
(2.5
4 c
m)
Bet
ween
Un
its
9–5
/32”
(23
.3
c
m)
82
3/
4”
(
2
1
0
.
2
cm)
mi
n
.
to
84–
1/16
(
2
1
3.
5
cm
)
m
a
x
.
20–
3/4”
(52
.7
c
m)
22
–3/
16”
(56
.4
cm
)
7
5
1
5
/
1
6
(1
9
2
.
9
c
m
)
3
–1
9
/
3
2
(
9
.
1
c
m
)
2
9
(73
.7 c
m
)
2
9
(73
.7
c
m
)
3
0
(
7
6
.
2 c
m
)
30
(
76
.
2 cm
)
2
7–
1/4
(
69
.
2
cm
)
Dimensions
12
Dual 30” Professional
Dual 30” & 36” Professional
Specifications
15
24–
11
/1
6
(62
.7 c
m
)
1”
(2.54
cm
)
Bet
wee
n u
nit
s
35”
(
88
.
9
c
m
)
3
5
(
8
8
.
9 c
m
)
3
6
(
91
.
5
c
m)
36
(
9
1
.
5
c
m
)
9–5/
32”
(23
.3
c
m)
82–
3/4”
(
21
0
.2
c
m
)
m
in
.
to
8
4–
1/1
6”
(
21
3.5 c
m
)
ma
x
.
20
3
/4
(52
.7
cm)
22
–3/
16”
(56
.4
cm)
75–
15/
16”
(19
2 .
9 c
m
)
3
–1
9
/3
2
(
9
.
1
c
m)
2
7
1/
4
(
69
.
2 cm
)
Dimensions
14
Dual 36” Professional
Dual Professional
Description (2) 30” Units (1) 36” & (1) 30” Unit (2) 36” Units
O
verall width 60” (152.4 cm) 66” (167.6 cm) 72” (182.9 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 22-3/16” (56.4 cm)
To front of top grille: 24-11/16” (62.7 cm) To front of handle endcap: 27-1/4” (69.2 cm)
Cutout width 59-1/2” (151.1 cm) 65-1/2” (166.4 cm) 71-1/2” (181.6 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements (2) 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 30” Freezer 9.1 amps per unit 30” Refrigerator 5.7 amps per unit
36” Freezer 9.5 amps per unit 36” Refrigerator 6.5 amps per unit
Inlet water requirements 1/4” coppertubing inlet waterline; minimum 20 psi;
(All Freezer only) maximum 120 psi
Overall interior dimensions
30” Freezer 15.9 cu. ft. (450 liters) 30” Refrigerator 18.2 cu. ft. (516 liters) 36” Freezer 19.1 cu. ft. (541 liters) 36” Refrigerator 22.8 cu. ft. (646 liters)
Approximate shipping weight 30”- Freezer 530 lbs. (238.5 kg) each; Refrigerator 505 lbs. (227.3 kg) each
36”- Freezer 585 lbs. (263.3 kg) each; Refrigerator 570 lbs. (256.5 kg) each
2
4
(
61
.0
c
m)
1”
(2.
54
cm)
B
et
wee
n Uni
ts
3
5
(8
8
.9
c
m
)
36
(
9
1
.
5 c
m
)
9
5
/
32
(23
.
3
c
m)
8
2
3
/
4
(2
1
0.2 c
m
)
m
in
.
t
o
84–
1/
16
(21
3.
5
cm
)
m
ax
.
2
0
3
/
4
(5
2
.7
c
m
)
2
3
3
/
8
(5
9.4
c
m
)
2
9”
(7
3
.7 cm)
7
5
–1
5
/1
6
(1
9
2 .
9 c
m
)
3–1
9/
3
2
(
9.
1
c
m
)
30
(
76
.
2 c
m
)
2
6–
1/2
(
67
.
3
c
m
)
Dimensions
17
24”
(61
.0
cm
)
1”
(2.5
4 c
m)
Bet
ween
Un
its
9–5
/32”
(23
.3
c
m)
82–
3/
4
(
2
1
0
.2
cm)
mi
n
.
to
84
1
/
1
6”
(
2
1
3.5 c
m)
m
a
x
.
20–
3/4”
(52
.7
c
m)
23–
3/
8
(59
.4
cm)
7
5–
1
5
/
1
6
(1
9
2
.
9
c
m
)
3
–1
9
/
3
2
(
9
.
1
c
m
)
2
9
(73
.7 c
m
)
2
9
(73
.7
c
m
)
3
0
(
7
6
.
2 c
m
)
30
(
76
.
2 cm
)
2
6
1/
2
(
67
.
3
cm
)
Dimensions
16
Dual 30” Professional Integrated Dual 30” & 36” Professional Integrated
Specifications
19
24”
(61
.0
cm
)
1”
(2.54
c
m)
Bet
wee
n uni
ts
35”
(
88
.
9
c
m
)
3
5
(
8
8
.
9
c
m
)
3
6
(
91
.
5 c
m)
36
(
9
1
.
5
cm
)
9–5/
32”
(23
.3
c
m)
82–
3/4”
(
21
0
.2
c
m
)
m
in
.
to
8
4–
1/1
6”
(
21
3.5 c
m
)
ma
x
.
20–
3/
4
(52
.7
cm)
23–
3/8”
(59
.4
cm)
75–
15/
16”
(19
2 .
9 c
m
)
3
–1
9
/3
2
(
9
.1
cm
)
2
6–
1/2
(
67
.
3
cm
)
Dimensions
18
Dual Professional Integrated
Description (2) 30” Units (1) 36” & (1) 30” Unit (2) 36” Units
O
verall width 60” (152.4 cm) 66” (167.6 cm) 72” (182.9 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8” (59.4 cm)
To front of top grille: 24” (61.0 cm) To front of handle endcap: 26-1/2” (67.3 cm)
Cutout width 60” (152.4 cm) 66” (167.6 cm) 72” (182.9 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements (2) 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 30” Freezer 9.1 amps per unit 30” Refrigerator 5.7 ampsper unit
36” Freezer 9.5 amps per unit 36” Refrigerator 6.5 amps per unit
Inlet water requirements 1/4” coppertubing inlet waterline; minimum 20 psi;
(All Freezer only) maximum 120 psi
Overall interior dimensions
30” Freezer 15.9 cu. ft. (450 liters) 30” Refrigerator 18.2 cu. ft. (516 liters) 36” Freezer 19.1 cu. ft. (541 liters) 36” Refrigerator 22.8 cu. ft. (646 liters)
Approximate shipping weight 30”- Freezer 530 lbs. (238.5 kg) each; Refrigerator 505 lbs. (227.3 kg) each
36”- Freezer 585 lbs. (263.3 kg) each; Refrigerator 570 lbs. (256.5 kg) each