Viking Professional VEWD173, VEWD173T, DFWD171, VEWD103, VEWD103T Installation Manual

...
Viking
Installation Guide
US
ii ii
n
_ w
I I o
Built-in Electric Warming Drawers
(Indoor and Outdoor Models)
Viking Range Corporation
111 Front Street
Greenwood, Mississippi 38930 USA
IMPORTANT - PLEASE READ AND FOLLOW
Before beginning, please read these instructions completely and carefully.
Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.
Pleaseobserve all local ordinances. If local codes are applicable, wire in accordance with the National Electrical
Code, ANSI/NFPA 70 - latest edition.
WARNING -To reduce the risk of electric shock and fire,
do not use a flexible power-supply cord with this
appliance.
WARNING - FOR OUTDOOR INSTALLATION, INSTALLER MUST INSTALL A GROUND FAULT INTERRUPT.
The installer should leave these instructions with the
consumer who should retain for local inspector's use and for future reference.
GENERAL INFORMATION
THIS UNIT IS NOT TO BEINSTALLED BELOW
CABINETS OR WALL MOUNTED.
When installing this unit directly below other units, only
install with Viking built-in products
Remove warming drawer carefully from carLon. Remove all
loose packaging and accessories. *it is the responsibility of the installer to comply with local
codes. If no local codes are applicable, wire inaccordance
with the National Electrical Code, ANSI/NFPA 70 - latest
edition.
This appliance is not fused. Protect with a proper sized fuse or circuit breaker and a GFI for outdoor models.
Line disconnect switch, circuit breaker, GFI (for outdoor models) or plug/receptacle of power cord connection should be readily accessible to the operator.
Ground unit per applicable electrical codes.
*Any installation not matching the specifications discussed in
these instructions will void the manufacturer's warranty.
Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying
voltage, hertz, wattage, amps, and phase is
attached to the product. Wiring the warming
drawer with more voltage than it is rated for may
cause severe damage to the thermostat, element, and other components. Wiring the
warming drawer with less voltage than it is rated for may cause significant decrease in
performance. To reduce the risk of fire, electric shock, or injury to persons, installation work and
electrical wiring must be clone by qualified people in accordance with all applicable codes and standards, including fire-rated conditions.
ELECTRICAL CONNECTION - USE COPPER
CONDUCTORS ONLY.
GROUNDING INSTRUCTIONS
This appliance must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead
on the appliance.
With the appliance positioned in front of the cabinet opening, connect wire leads extending from the power
supply to the terminal block of the unit. Make sure the colored wires of the terminal block are connected to the
corresponding colored wires extending from the power supply.
BASIC SPECIFICATIONS
MODEL
Interior width Interior height
Interior depth Electrical
Recluirements Max. Amp Usage
Approx. shipping Wt.
VEWD173 VEWD173T
DEWD171 DFWD171
17 1/4 (43.8 cm) 6" (15.2 cm)
22 3/4" (27.8 cm)
VEWD103 VEWD103T
DEWD101 DFWD101
20 1/2" (52.1 cm) 6" (15.2 cm) 22 3/4" (27.8 cm)
VEWD163 VEWD163T
25" (63.5 cm) 6" (15.2 cm)
22 3/4" (27.8 cm)
Hard wire direct with separate 15 amp minimum 2-wire with ground circuit; 120 VAC/50-60 Hz
425 watts 450 watts 550 watts
3.6 amps 3.8 amps 4.6 amps 80 lb. (36 kg) 90 lb. (40.5 kg) 110 lb. (49.5 kg)
CABINET CUTOUT
INDOOR MODELS (VEWD, DEWD)
23 3/8" (59.4cm)
I
I
9 I/4" (23.5cm)
Cabinet
Model VEWD173 VEWD103 VEWD163
DEWD171 DEWD101
A 25 1/4" 28 1/4" 34"
(64.1 cm) (71.8 cm) (86.4 cm)
Mounting Screws (4) - #8 x 3/4"
Cavity Assy.
Drawer
Assy.
OUTDOOR MODELS
Cabinet
(5.1 cm)
min.
23 3/8"
Model
A
91/4" (23.5 cm)
Cavity Assy.
I all around
opening
silicon caulk that is
provided.
VEWD173T
25 1/4"
(64.1 cm)
VEWD103T
28 1/4"
(71.8 cm)
VEWD163T
34"
(86.4 cm)
Dra
Assy.
Loading...