QUICK START GUIDE
VIKING
Electronics, Inc.
K See Product Manual for complete installation and programming instructions.
1.0 Out-of-Box
1.1 Verify that you have received all of the parts listed
1.2 Download the product manual
1. Go to www.vikingelectronics.com and
enter E-60-BK-IP in the search box
2. Click E-60-BK-IP in the search results
3. Click Product Manual to open and
download the PDF
1.3 Download and install the programming software
1. Go to www.vikingelectronics.com and enter E-60-BK-IP in the search box
2. Click E-60-BK-IP in the search results
3. Scroll down the page to Downloads, click IP Programming Software
4. Install the programming software by saving or opening the file and then clicking on
setup Viking IP Programming.exe
5. Follow the prompts on your screen to complete software installation
2.0 Power Source
Select PoE Switch or PoE Injector that meets the following requirements:
1. IEEE 802.3af / 802.3at / 802.3bu compliant
2. Capable of providing at least 4 Watts (class 1)
Note: CAT5e (or higher) cable recommended
X 1
E-60-BK-IP or E-60-BK-IPEWP Entry Phone
X 1
Face Plate Black
X 1
Faceplate Gasket
X 2
Plate Adapter
X 1
Light Pipe
X 4
6-32 x 1.25” Flat Head Hex
Drive Screws Black painted
X 4
6-32 x 3/4” Flat Head Hex
Drive Screws
X 1
Hexkey 5/64
X 5
Gel-Filled Butt Connectors
Scan the QR code to
open and download
the product manual
- OR -
E-60-BK-IP or
E-60-BK-IP-EWP
VoIP Entry Phone
September 25, 2018

4.0 Features Overview
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries
assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.
See the Product Manual for complete installation and programming instructions.
Questions? Call Viking Product Support: 715-386-8666
E-60-BK-IP Quick Start Guide ZF303684 REV A
• Make sure the port is not in trunk mode
• Make sure port is capable of 100mbps full duplex
• Disable Spanning Tree Protocol (STP) or enable Portfast
3.0 Network Port Settings
Note: The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a
maximum insulation of 0.082 inches. Cut off stripped wire ends before terminating.
* Note: For applications requiring additional security, a Viking model RC-4A remote relay controller can be used. The relay
controller is mounted securely inside the building and connected to the same LAN as the E-60-BK-IP. For more information
on the RC-4A Secure Relay Controller, see DOD 582.
Rear (PCB) View
of E-60-IP
Green Unit Status LED
Yellow Network Status LED:
Lights steady to indicate power
and data link. Blinks to indicate
network activity.
Connect to Optional
Doorstrike, Mag Lock,
Gate Controller, etc.
120V AC
(not
connected)
Doorstrike /
Magnetic Lock
(Power typically not
required for gate controllers)
* On-Board 2 Amp
Relay Output Contacts
(2A@30VDC/ 250VAC max)
N.C. (Gray)
COM. (Blue)
N.O. (Yellow)
3 Gel-Filled Butt
Connectors (included)
18E80FXXXXXX
asdesaxtff
MAC:
- Black
+ Red
Green
Green
White
White
- Black
+ Red
LED
Black
Help Switch
Black
Request for Exit (REX Input)
Speaker
Microphone
PoE LAN Port 10/100, PoE
Class 1 (<4 Watts): Connect
to your LAN via RJ45 plug
and CAT5 or greater twisted
pair wire.
MAC Address Label: The
MAC address is aunique 12
digit number used by routers
to send network traffic to the
correct IP address.