Viking VGSU103-4B, VGSU163-6B User Manual

Professional Built-In Gas 30”/36”W. Cooktop
Standard Features & Accessories
Both models include
• Updated commercial-type styling incorporates refined detailing
• Sealed burners with brass flame ports, porcelain/cast iron caps, and automatic ignition/re-ignition
• Durable metal knobs with childproof, push-to-turn safety feature
• 16,000 BTU burner for faster heat-up
4B model includes
• Dimensioned to fit virtually all 30”W. cooktop cutouts
• Four burners o Left front—16,000 BTU high/3,400
BTU low
o Left rear—12,000 BTU high/1,700
BTU low
o Right rear—8,000 BTU high/1,200
BTU low
o Right front—6,000 BTU high/950
BTU low
• Two separate spill collection areas— each holds 3-1/2 c. liquid spills
6B model includes
• Dimensioned to fit virtually all 36”W. cooktop cutouts—the only “countertop cutout” six-burner cooktop in 36”W.
• Six burners o Left front—16,000 BTU high/3,400
BTU low
o Left rear—12,000 BTU high/1,700
BTU low
Model Options
COOKING
o Center front—12,000 BTU
high/1,700 BTU low
o Center rear—12,000 BTU high/1,700
BTU low
o Right rear—8,000 BTU high/1,200
BTU low
o Right front—6,000 BTU high/950
BTU low
• Two separate spill collection areas— each holds 4-1/2 c. of liquid spills
30”W. Four-Burner Cooktop
FINISH DETAILS FOR BOTH MODELS
• Stainless Steel (SS) and Black (BK) o Finish designates top. Stainless steel
trim/frame and control panel.
o Black porcelain grates, porcelain
burner caps, and knobs.
• White (WH) o Finish designates top. Dark gray
porcelain grates and porcelain burner caps, with white knobs.
VGSU103-4B
• Brass Trim Option (BR)—nameplate,
VGSU163-6B
36”W. Six-Burner Cooktop
knob bezels, and control panel frame. Brass components have a durable protective coating for maintenance­free normal use.
ORDERING INSTRUCTIONS
First specify model number, and then color code (VGSU102-4BSS). If ordering optional brass trim, specify code at end (VGSU102-4BSSBR). If ordering optional LP conversion, specify code at end (
P LA NN IN G A ND D E S I G N G U I D E
V I K I N G R A N G E . C O M 1 - 8 8 8 - V I K I N G 1
VGSU102-4B
SSBRLP).
R E L EA SE D 1 2 / 1 /0 7
© 2 0 07 VR C— IN FO RM AT I O N S U B JE CT TO C HA NG E
2
1
(53
.
3
c
m
)
30
-
3
/
4
(78
.
1
c
m
)
3
0-
3/
4”
(7
8
.
1
c
m
)
5”
(1
2
.7
c
m
)
2
1
(53
.3
c
m
)
3
6-
3
/4
(93
.
3
c
m
)
3
6-
3
/4
(93
.
3
c
m
)
5
(12
.7
c
m
)
COOKING
1”
(2.5 cm)
2-1/2”
(6.4 cm)
5”
(12.7 cm)
13/16”
(2.1 cm)
6-19/32”
(16.7 cm)
Professional Built-In Gas 30”/36”W. Cooktop
Please see
Installation Notes &
Accessories
for important
installation
information,
including
conversion kits.
Dimensions & Specifications
OVERALL PRODUCT DIMENSIONS
VGSU103-4B
30”W. Four-Burner
Cooktop
VGSU163-6B
36”W. Six-Burner
Cooktop
30”W. Models 36”W. Models
FRONT VIEW SIDE VIEW
Overall width 30-3/4” (78.1 cm) 36-3/4” (93.3 cm) Overall height (top of grate to bottom) 5” (12.7 cm) Overall depth (from rear) 21” (53.3 cm)
VGSU103-4B VGSU163-6B
P LA NN IN G A ND D E S I G N G U I D E
V I K I N G R A N G E . C O M 1 - 8 8 8 - V I K I N G 1
R E L EA SE D 1 2 / 1 /0 7
© 2 0 07 VR C— IN FO RM AT I O N S U B JE CT TO C HA NG E
Professional Built-In Gas 30”/36”W. Cooktop
3-
1/
2
(
8.
9
c
m
)
3
6”
min
.
(
9
1.
4
cm
)
3
-1
/
8”
(
7
.
9
c
m
)
36
mi
n.
(
9
1.
4
cm
)
1
8
m
i
n
.
(45
.
7
cm)
1
3
”m
a
x.
(
3
3
.
0 cm
)
8
m
i
n.
(
2
0
.
3
cm
)
Dimensions & Specifications
CLEARANCE DIMENSIONS
COOKING
Minimum clearances from adjacent combustible construction
• Sides—8” (20.3 cm)
• Rear—3-1/2” (8.9 cm) min.
• Within 8” (20.3 cm) side clearance; wall cabinets no deeper than 13” (33.0 cm)
• Must be minimum 18” (45.7 cm) above countertop
• Wall cabinets directly above cooktop must be minimum 36” (91.4cm) above the countertop.
1. The cooktop may be installed directly
to existing base cabinets.
2. The cooktop cannot be installed
directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36” (91.4 cm) high. There must be a minimum of 8” (20.3 cm) side clearance from the
P LA NN IN G A ND D E S I G N G U I D E
V I K I N G R A N G E . C O M 1 - 8 8 8 - V I K I N G 1
cooktop to such combustible surfaces above the 36” (91.4 cm) counter height.
3. Within the 8” (20.3 cm) side clearance to combustible vertical surfaces above 36” (91.4 cm), the maximum wall cabinet depth must be 13” (33.0 cm) and wall cabinets within this 8” (20.3 cm) side clearance must be 18” (45.7 cm) above the 36” (91.4 cm) high countertop.
4. Wall cabinet above the cooktop must be a minimum of 36” (91.4 cm) above the countertop for a full width of the cooktop. This minimum height requirement does not apply if a hood is installed over the cooking surface.
5. A 120-volt wall receptacle should be located approximately 6” (15.2 cm) below the countertop cutout and
12” (30.5 cm) from the right side of the cutout.
The bottom of the hood should be 30” (76.2 cm) min. to 36” (91.4 cm) above the countertop. This would typically result in the bottom of the hood being 66”(167.6 cm) to 72” (182.9 cm) above the floor. Refer to the hood installation instructions for further information.
Warning
The use of cabinets for storage above the appliance may result in a potential burn hazard. If a cabinet storage is to be provided the risk can be reduced by installing a hood that projects horizontally a minimum of 5” (12.7 cm) beyond the bottom of the cabinets.
R E L EA SE D 1 2 / 1 /0 7
© 2 0 07 VR C— IN FO RM AT I O N S U B JE CT TO C HA NG E
18-1/2”
(46.2 cm)
26-7/8”
(68.3 cm) min.
to
29-7/8”
(75.9 cm) max.
26-3/4”
(67.9 cm)
1-5/16” (3.3 cm)
3” (7.6 cm)
28-1/16”
(71.3 cm)
Cutout O
pening
18-1/2”
(46.2 cm)
18-3/4”
(47.6 cm)
COOKING
34-3/8”
(87.3 cm) min.
to
35-7/8”
(91.1 cm) max.
33”
(83.8 cm)
1
8-1/2”
(46.2 cm)
1-1/4”
(3.2 cm)
3” (7.6 cm)
34-1/4”
(87.0 cm)
C
utout
Opening
18-1/2”
(46.2 cm)
18-3/4”
(47.6 cm)
Professional Built-In Gas 30”/36”W. Cooktop
UTILI TY
REQU IR EM ENTS
AS
G
• Shipped natural gas tandard; to field
s
onvert from natural
c or LP/Propane, the orifice spuds and
egulator must be
r
hysically changed.
p o Order conversion
kit NK2VGSU to
onvert natural
c and LPK-3VGSU to convert to LP
Accepts standard
• esidential 1/2”
r (1.3 cm) ID gas service line Gas manifold
pressure o Natural gas 5.0”
W.C.P.
o LP/propane 10.0”
W.C.P.
Installation Requirements
ACCESS REQUIREMENTS
VGSU103-4B
30”W. Four-Burner
Cooktop
VGSU163-6B
36”W. Six-Burner
Cooktop
30”W. Cutout 36”W. Cutout
ELECTRICAL
• 4-foot (121.9 cm)
cord included with cooktop
• 3-wire with
ground/3-prong plug
• 120 V/60 Hz
• Maximum amp
usage—2.0
PLUMBING
Not applicable
Cutout width 26-7/8” (68.3 cm) min. to 29-7/8” (75.9 cm) max. 34-3/8” (87.3 cm) min. to 35-7/8” (91.1 cm) max. Cutout height 2-1/2” (6.4 cm) min. Cutout depth 18-5/8” (47.3 cm) min. to 20-1/8” (51.1cm) max.
Surface burner rating
Left front 16,000 BTU Nat. (4.8 kW)/15,500 BTU LP (4.65 kW) Left rear 12,000 BTU Nat. (3.6 kW)/11,500 BTU LP (3.45 kW) Right rear 8,000 BTU Nat. (2.4 kW)/7,500 BTU LP (2.25 kW) Right front 6,000 BTU Nat. (1.8 kW)/5,500 BTU LP (1.65 kW) Center front/rear N/A 12,000 BTU Nat. (3.6 kW)/11,500 BTU LP (3.5 kW)
30”W. Cutout w/Downdraft 36”W. Cutout w/Downdraft
VGSU103-4B VGSU163-6B
P LA NN IN G A ND D E S I G N G U I D E
V I K I N G R A N G E . C O M 1 - 8 8 8 - V I K I N G 1
R E L EA SE D 1 2 / 1 /0 7
© 2 0 07 VR C— IN FO RM AT I O N S U B JE CT TO C HA NG E
COOKING
Professional Built-In Gas 30”/36”W. Cooktop
Installation Notes & Accessories
Conversion Kits
• For field conversion between gas fuel types
• Kit includes all hardware necessary to convert a 30”W. or 36”W. VGSU cooktop
Model Description Approx. ship wt. lbs. (kg)
LPK3-VGSU Natural to LP/propane conversion kit 1 (0.5) NK2-VGSU LP/propane to natural conversion kit 1 (0.5)
Compliance Information
WARRANTY INFORMATION*
• One-year full warranty—complete product
• Five-year limited warranty—surface burners
• Ninety-day limited warranty—cosmetic parts such as glass, painted, and decorative items
* For complete warranty see Use & Care Guide. Warranty valid on Viking products shipped within the United States and Canada.
P LA NN IN G A ND D E S I G N G U I D E
V I K I N G R A N G E . C O M 1 - 8 8 8 - V I K I N G 1
© 2 0 07 VR C— IN FO RM AT I O N S U B JE CT TO C HA NG E
R E L EA SE D 1 2 / 1 /0 7