Viking VWH53012, VWH53612, VWH53048, VWH53648, VWH54248 Installation Guide

...
Installation
Professional Indoor & Outdoor Hoods
VWH53012 / VWH53612
VWH53048 / VWH53648 / VWH54248
VWH54848 / VWH56048
VCWH53048 / VCWH53648 / VCWH54248
VCWH54848 / VCWH56048
VCIH53608 / VCIH54208 / VCIH55408 / VCIH56608
VWHO3678 / VWHO4878 / VWHO6078 (Canadian Outdoor models not applicable)
2
Warnings & Important Information
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 -
4
VWH/CVWH 10” H/12”H. Wall Hoods w/Standard Ventilator 30”, & 36”
D i m e n s i o n s & S p e c i f i c a t i o n s _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 5 Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 6 Interior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 7
VWH/CVWH 18”H. 24”Deep Wall Hoods 30”, 36”, 42”, 48”, & 60”
D i m e n s i o n s & S p e c i f i c a t i o n s _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 8 Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 9 Interior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 0 Exterior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 1
VWHO/CVWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”
D i m e n s i o n s & S p e c i f i c a t i o n s _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 2 Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 3
VCWH/CVCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, & 60”
D i m e n s i o n s & S p e c i f i c a t i o n s _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 4 Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 5 Interior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 6 Exterior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 7
VCIH/CVCIH Chimney Island Hoods 36”, 42”, 54”, & 66”
D i m e n s i o n s & S p e c i f i c a t i o n s _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 8 Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 9 Interior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 0 Exterior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 1
VBCV/CVBCV Wall Custom Ventilator System
D i m e n s i o n s & S p e c i f i c a t i o n s _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 2 Installing Hood Canopy _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 3 Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 4
VBCV Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 5 Planning Information _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 7 Installation Procedures
Installation (VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator) _ _ _ _ _ _ _ _ _ _ _ _ _ 28
Duct Cover Option (VWH/CVWH 12”H. Wall Hoods w/Standard Ventilator) _ _ _ _ _ _ _ _ _ _ _ _ 30
Installation (VWH/CVWH 12”H. Wall Hoods w/Recirculating Kit) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 30
Installation (VWH/CVWH 18”H. Wall & VCWH Chimney Wall Hoods) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 33
Duct Cover Option (VWH/CVWH 18”H. Wall Hoods) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 34
Duct Cover Option (VCWH/CVCWH Chimney Wall Hoods) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 35
Installation (VCIH Island Hoods) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 6 Service & Registration_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 8 Wiring Diagram _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 9
Table of Contents
3
NOTE:
If installing hood with warming shelf panel, install
warming shelf panel first.
IMPORTANT – PLEASE READ AND FOLLOW
• Before beginning, please read these instructions
completely and carefully.
• Do not remove permanently affixed labels, warnings, or
plates from the product. This may void the warranty.
• Please observe all local and national codes and
ordinances. If no local codes are applicable, wire in accordance with the National Electrical Code, ANSI/NFPA 70-latest edition.
• Damp environment approved models should be installed
in a covered non-enclosed area and should be protected from the elements as much as possible.
• The installer should leave these instructions with the
consumer who should retain for local inspector’s use and for future reference.
• Check with a qualified and trained installer or local codes
for makeup air requirement, if any.
This hood is for residential installation only and is not designed for installation over a commercial product. Make sure power is off at the main circuit breaker or fuse box before making connections. To avoid risk of fire, electric shock, or injury to persons, turn off the electricity to the hood from the power supply before servicing or cleaning. Viking hoods are equipped with variable speed control blowers. These units will not function with a single speed ventilator. All Viking Range ventilator kits are designed specifically for use with Viking Range hoods. Use of any non-Viking Range ventilator kit will void the hood warranty.
Viking hoods are equipped with the variable speed controls for blowers. These units will not function with a single speed ventilator. All Viking ventilator kits are designed specifically for use with Viking hoods. Use of any non-Viking ventilator kit will void the hood warranty.
READ AND SAVE THESE INSTRUCTIONS
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
2. Sufficient air is needed for proper combustion and exhausting of gases through the flute (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
3. When cutting of drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
4. Ducted fans must always be vented to the outdoors.
5. WARNING!: To reduce risk of fire, use only metal ductwork
6. CAUTION!: To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings, or into attics, crawl spaces, or garages.
7. CAUTION!: To Reduce the Risk of Fire and Electric Shock, Install this rangehood only with remote blower models manufactured by Viking, model numbers – DEV900/DEV1200, VEV900, VIL1200, OR DEV1500 or integral blowers manufactured by Viking, model numbers – VINV300/600/1200, or DIL1200. NOTE – Please refer inside for specific canopy/blower combinations.
WARNING
WARNING
To reduce the risk of fire, electric shock, or injury to persons, observe the following:
• Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
• Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
IMPORTANT–Please Read and Follow!
4
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS
Rangehoods must be installed with the ventilators that are specified on their carton indicating suitability with this model. Other ventilators cannot be substituted.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
WARNING
To reduce the risk of injury to persons in the event of a rangetop grease fire, observe the following. (Based on “Kitchen Firesafety Tips,” published by NFPA.)
1. SMOTHER FLAMES with a close fitted lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN. You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels a violent steam explosion will result.
4. Use an extinguisher ONLY if
• You know it is a Class ABC extinguisher, and you
already know how to operate it.
• The fire is small and contained in the area where
it started.
• The fire department is being called.
• You can fight the fire with your back to an exit.
IMPORTANT–Please Read and Follow!
WARNING
This appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
5
(VWH 10”H./12”H. Wall Hoods w/Standard Ventilator 30”, & 36”)
* Disregard when using recirculating kits. 460 CFM blower is shipped with hood.
NOTE: Optional duct cover sold separately.
VWH/CVWH 10”H./12”H. Wall Hoods
w/Standard Ventilator
Description 30” 36”
Duct cover width
29-7/8” (75.9 cm) 35-7/8” (91.1 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm)
Number of lights
2
Number of filters
2
Heat lamps
N/A
Interior ventilator kit
460 CFM Standard
Interior duct size*
7” (17.8 cm)
Interior—Maximum amps
5.6 A
Dimensions & Specifications
12 ”
(30.5 cm)
10”
(25.4 cm)
5”
(12.7 cm)
A
A (Hood width) 30”W. 29-7/8“ (76.2 cm) 36”W. 35-7/8” (91.1 cm)
21”
(53.3 cm)
5”
(12.7 cm)
A
(53.3 cm)
A (Hood width) 30”W. 29-7/8“ (76.2 cm) 36”W. 35-7/8” (91.1 cm)
21”
12 ”
(30.5 cm)
12 ”
(30.5 cm)
6
(VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator)
Clearance Dimensions
60" min.
(152.4 cm)
to
63" max.
(160.0 cm)
36"
(91.4 cm)
* NOTE: When installing with a 24” high-shelf, the 27” (68.6 cm) max. dimensions must be used.
24" min.
(61.0 cm)
27" max.*
to
(68.6 cm)
7
460 CFM Interior Ventilator Installation
Top View
(VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator)
Interior Ventilator Dimensions
A 24”W. 23-7/8” (60.6 cm) 30”W. 29-7/8” (75.9 cm) 36”W. 35-7/8” (91.1 cm)
B 24”W. 5-1/4” (13.3 cm) 30”W. 8-1/4” (20.9 cm) 36”W. 11-1/4” (28.6 cm)
B
C
4”
(10.2 cm)
A
18”
(4.6 cm)
D
3-4”
(1.9 cm)
1/2”
(1.3 cm)
3-1/2”
(8.9 cm)
C 24”W. 11-15/16” (30.3 cm) 30”W. 14-15/16” (37.9 cm) 36”W. 17-15/16” (45.6 cm)
D
24”W. 5/8” (1.6 cm) 30”W. 3-5/8” (9.2 cm) 36”W. 6-5/8” (16.8 cm)
(9.8 cm)
7” (17.8 cm) dia. duct location
3-7/8”
Electrical hookup
8
24"
(61.0 cm)
A
18"
(45.7 cm)
12"
(30.5 cm)
6"
(15.2 cm)
A 30" W 29-7/8" (76.2 cm) 36" W 35-7/8" (91.1 cm) 42" W 41-7/8" (106.4 cm) 48" W 47-7/8" (121.6 cm) 60" W 59-7/8" (152.1 cm)
(VWH/CVWH 18”H. 24” Deep Wall Hoods 30”, 36”, 42”, 48”, & 60”)
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2­wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
NOTE: Optional duct cover sold separately.
VWH/CVWH 18”H. Wall Hoods
Description 30” 36” 42” 48” 60”
Duct cover width
29-7/8”
(75.9 cm)
35-7/8”
(91.1 cm)
41-7/8”
(106.4 cm)
47-7/8”
(121.6 cm)
59-7/8”
(152.1 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm)
Number of lights
2 2 2 3 4
Number of filters
2 2 2 3 4
Heat lamps
1 1 1 2 3
Interior ventilator kits
VINV300/ 600/1200
VINV300/ 600/1200
VINV600/
1200
VINV1200* VINV1200*
Exterior ventilator kits
DEV900/
1200*
DEV900/
1200*
DEV900/
1200*
DEV1200*/
1500**
DEV1200*/
1500**
In-line ventilator kits
DIL1200 DIL1200 DIL1200 DIL1200 DIL1200
Interior duct size
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
Exterior duct size
10” (24.5 cm)
Interior—Maximum amps
4.2/5.2/8.2 4.2/5.2/8.2 5.2/8.2 10.8 10.8
Exterior—Maximum amps
8.0/5.3 8.0/5.3 8.0/5.3 7.8/8.5 7.8/8.5
In-Line—Maximum amps
5.3/7.2 5.3/7.2 5.3/7.2 9.6 10.0
Total Watts
47 Watts
Dimensions & Specifications
9
(VWH/CVWH 18”H. Wall Hoods)
Clearance Dimensions
36”
(91.4 cm)
66” min.
(167.6 cm)
to
72” max.
(182.9 cm)
30” min.
(76.2 cm)
to
36” max.
(91.4 cm)
10
300 or 600 CFM Interior Ventilator Installation for all Wall Hoods
1200 CFM Interior Ventilator Installation for all Wall Hoods
Top View
Top View
(VWH/CVWH 18”H. Wall Hoods)
Interior Ventilator Dimensions
A
A 30" W 14-15/16" (37.9 cm) 36" W 17-15/16" (45.6 cm) 42" W 20-15/16" (53.2 cm) 48" W 23-15/16" (60.8 cm) 60" W 29-15/16" (76.0 cm)
4-5/8"
(11.7 cm)
7" (17.8 cm) dia. duct location
30" W 29-7/8" (75.9 cm) 36" W 35-7/8" (91.1 cm) 42" W 41-7/8" (106.4 cm) 48" W 47-7/8" (121.6 cm) 60" W 59-7/8" (152.1 cm)
B
B
A
A 30" W 14-15/16" (37.9 cm) 36" W 17-15/16" (45.6 cm) 42" W 20-15/16" (53.2 cm) 48" W 23-15/16" (60.8 cm) 60" W 29-15/16" (76.0 cm)
5-1/2"
(14.0 cm)
10" (25.4 cm) dia. duct location
30" W 29-7/8" (75.9 cm) 36" W 35-7/8" (91.1 cm) 42" W 41-7/8" (106.4 cm) 48" W 47-7/8" (121.6 cm) 60" W 59-7/8" (152.1 cm)
B
B
11
900 or 1200 CFM Exterior or In-Line Ventilator Installation for all
Wall Hoods
1200 or 1500 CFM Exterior or In-Line Ventilator Installation for all
Wall Hoods
Top View
Top View
(VWH/CVWH 18”H. Wall Hoods)
Exterior Ventilator Dimensions
A
A 30" W 14-15/16" (37.9 cm) 36" W 17-15/16" (45.6 cm) 42" W 20-15/16" (53.2 cm) 48" W 23-15/16" (60.8 cm) 60" W 29-15/16" (76.0 cm)
5-15/16" (15.1 cm)
10" (25.4 cm) dia. duct location
30" W 29-7/8" (75.9 cm) 36" W 35-7/8" (91.1 cm) 42" W 41-7/8" (106.4 cm) 48" W 47-7/8" (121.6 cm) 60" W 59-7/8" (152.1 cm)
B
B
A
A 30" W 14-15/16" (37.9 cm) 36" W 17-15/16" (45.6 cm) 42" W 20-15/16" (53.2 cm) 48" W 23-15/16" (60.8 cm) 60" W 29-15/16" (76.0 cm)
5-15/16"
(15.1 cm)
10" (25.4 cm) dia. duct location
30" W 29-7/8" (75.9 cm) 36" W 35-7/8" (91.1 cm) 42" W 41-7/8" (106.4 cm) 48" W 47-7/8" (121.6 cm) 60" W 59-7/8" (152.1 cm)
B
B
12
27"
(68.6 cm)
A
18"
(45.7 cm)
12"
(30.5 cm)
6"
(15.2 cm)
A 36" W 35-7/8" (91.1 cm) 48" W 47-7/8" (121.6 cm) 60" W 59-7/8" (152.1 cm)
Seal joints with silicone.
Provided on “T” Series only.
(VWHO/CVWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”)
* A 1,200 CFM interior- or exterior-power ventilator should be used with all outdoor models and when i ndoor models are
installed over range/rangetop with gas char-grill. Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2­wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
NOTE: Optional duct cover sold separately.
VWHO/CVWHO 18”H. Outdoor Wall Hoods
Description 36” 48” 60”
Duct cover width
35-7/8” (91.1 cm) 47-7/8” (121.6 cm) 59-7/8” (152.1 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm)
Number of lights
2 3 4
Number of filters
2 3 4
Interior ventilator kits
VINV1200* VINV1200* VINV1200*
Exterior ventilator kits
DEV1200*/1500** DEV1200*/1500** DEV1200*/1500**
In-line ventilator kits
DIL1200 DIL1200 DIL1200
Interior duct size
10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
Interior—Maximum amps
9.0 11.4 11.8
Exterior—Maximum amps
6.1/6.8 8.4/9.1 8.8/9.5
In-Line—Maximum amps
7.9 10.2 10.6
Total watts
47 Watts
Dimensions & Specifications
13
30" min.
(76. 2 cm)
to
36" max.
(91.4 cm)
36"
(91.4 cm)
66" min.
(167.6 cm)
to
72" max.
(182.9 cm)
27"
(68.6 cm)
DIM « X »
+ 4-1/2"
(11.4 cm)
18"
(45.7 cm)
(VWHO/CVWHO 18”H. Outdoor Wall Hoods)
Note: Outdoor Models must be installed in a covered, non-enclosed area, and should be protected from the elements as much as possible.
The bottom of the hood should be 30” (76.2 cm) to 36” (91.4 cm) above the grill surface. The hood should be installed 4-1/2” (11.4 cm) plus the distance between the back trim and surface from the back wall. (Note: DIM “X” - There is a 3” minimum clearance from the back trim to non-combustible surfaces, and a 24” minimum to combustible surfaces.) This will require building the hood out from the wall. Any combustible material used for this purpose must be covered with locally-supplied stainless steel. It is also recommended to use a backsplash.
Clearance Dimensions
14
24”
(61.0 cm)
B
A
18”
(45.7 cm)
12”
(30.5 cm)
to
24”
(61.0 cm)
6”
(15.2 cm)
A (Duct width) 30”W. 12“ (30.5 cm) 36”W. 12“ (30.5 cm) 42”W. 12“ (30.5 cm) 48“W. 18“ (45.7 cm) 60”W. 24“ (61.0 cm) 66”W. 24“ (61.0 cm)
B (Hood width) 30”W. 29-7/8“ (76.2 cm) 36”W. 35-7/8” (91.1 cm) 42”W. 41-7/8” (106.4 cm) 48“W. 47-7/8” (121.6 cm) 60”W. 59-7/8” (152.1 cm) 66”W. 65-7/8” (167.3 cm)
(VCWH/CVCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, 54”, & 60”)
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max
duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
NOTE: Optional duct cover sold separately.
VCWH Chimney Wall Hoods
Description 30” 36” 42” 48” 60”
Duct cover width
12” (30.5 cm) 12” (30.5 cm) 12” (30.5 cm) 18” (45.7 cm) 24” (61.0 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm) to 24” (61.0 cm)
Number of lights
2 2 2 3 4
Number of filters
2 2 2 2 3
Heat lamps
1 1 1 2 3
Interior ventilator kits
VINV300/600 VINV300/600 VINV600 VINV1200* VINV1200*
Exterior ventilator kits
DEV900/
1200*
DEV900/
1200*
DEV900/
1200*
DEV1200*/
1500**
DEV1200*/
1500**
In-line ventilator kits
DIL1200 DIL1200 DIL1200 DIL1200 DIL1200
Interior duct size
7” (17.8 cm) 7” (17.8 cm) 7” (17.8 cm) 10” (25.4 cm) 10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
Interior—Maximum amps
4.2/5.2 4.2/5.2 5.2 10.8 10.8
Exterior—Maximum amps
8.0/5.3 8.0/5.3 8.0/5.3
7.8/8.5 7.8/8.5
In-Line—Maximum amps
5.3/7.2 5.3/7.2 5.3/7.2 9.6 10.0
Total Watts
47Watts
Dimensions & Specifications
15
(VCWH/CVCWH Chimney Wall Hoods)
Clearance Dimensions
36”
(91.4 cm)
66” min.
(167.6 cm)
to
72” max.
(182.9 cm)
30” min.
(76.2 cm)
to
36” max.
(91.4 cm)
16
300 or 600 CFM Interior Ventilator Installation
for 30”, 36”, & 42” models
1200 CFM Interior Ventilator Installation
for 48”, & 60”models
Top View
Top View
(VCWH/CVCWH Chimney Wall Hoods
)
Interior Ventilator Dimensions
12”
(30.5 cm)
A
A 30”W. 14-15/16” (37.9 cm) 36”W. 17-15/16” (45.6 cm) 42”W. 20-15/16” (53.2 cm)
B 30”W. 29-7/8” (75.9 cm) 36”W. 35-7/8” (91.1 cm) 42”W. 41-7/8” (106.4 cm)
6”
(15.2 cm)
7” (17.8 cm) dia. duct location
B
1-1/2”
(3.8 cm)
1-1/2”
(3.8 cm)
120V power supply
A 48”W. 23-15/16” (60.8 cm) 60”W. 29-15/16” (76.0 cm) 66”W. 32-15/16” (83.7 cm)
B
48”W. 47-7/8” (121.6 cm) 60”W. 59-7/8” (152.1 cm) 66”W. 65-7/8” (167.3 cm)
C
A
6”
(15.2 cm)
10” (25.4 cm) dia. duct location
B
1-1/2”
(3.8 cm)
1-1/2”
(3.8 cm)
120 V power supply
C 48”W. 18” (45.7 cm) 60”W. 24” (61.0 cm) 66”W. 24” (61.0 cm)
17
A 48”W. 23-15/16” (60.8 cm) 60”W. 29-15/16” (76.0 cm) 66”W. 32-15/16” (83.7 cm)
C 48”W. 18” (45.7 cm) 60”W. 24” (61.0 cm) 66”W. 24” (61.0 cm)
10” (25.4 cm) dia. duct location
6”
(15.2 cm)
1-1/2”
(3.8 cm)
1-1/2”
(3.8 cm)
A
B
C
120 V power supply
B 48”W. 47-7/8” (121.6 cm) 60”W. 59-7/8” (152.1 cm) 66”W. 65-7/8” (167.3 cm)
900 or 1200 CFM Exterior or In-Line Ventilator Installation
for 30”, 36”, & 42” models
900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation
for 48”, & 60”models
Top View
Top View
(VCWH/CVCWH Chimney Wall Hoods
)
Exterior Ventilator Dimensions
12”
(30.5 cm)
A
A 30”W. 14-15/16” (37.9 cm) 36”W. 17-15/16” (45.6 cm) 42”W. 20-15/16” (53.2 cm)
B 30”W. 29-7/8” (75.9 cm) 36”W. 35-7/8” (91.1 cm) 42”W. 41-7/8” (106.4 cm)
6”
(15.2 cm)
10” (25.4 cm) dia. duct location
B
1-1/2”
(3.8 cm)
1-1/2”
(3.8 cm)
120V power supply
18
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct
run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire with ground. An interior or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
30"
(76.2 cm)
C
A
18"
(45.7 cm)
B
6"
(15.2 cm)
C 36" W 35-7/8" (91.1 cm) 42" W 41-7/8" (106.4 cm) 54" W 53-7/8" (136.8 cm) 66" W 65-7/8" (167.3 cm)
B 36" W. 42" W. 54" W. 66" W.
12" (30.5 cm)
or
24" (61.0 cm)
or
36" (91.4 cm)
A 36" W 12" (30.5 cm) 42" W 12" (30.5 cm) 54" W 18" (45.7 cm) 66" W 24" (70.0 cm)
NOTE: Optional duct cover sold separately.
(VCIH/CVCIH Chimney Island Hoods 36”, 42”, 54”, & 66”)
VCIH/CVCIH Chimney Island Hoods
Description 36” 42” 54” 66”
Duct cover width
12” (30.5 cm) 12” (30.5 cm) 18” (45.7 cm) 24” (70.0 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm) or 24” (61.0 cm) or 36” (91.4 cm)
Number of lights
4 4 6 8
Number of filters
4 4 6 8
Heat lamps
N/A
Interior ventilator kits
VINV600 VINV600 VINV1200* VINV1200*
Exterior ventilator kits
DEV900/1200* DEV900/1200*/1500** DEV1200*/1500** DEV1200*/1500**
In-line ventilator kits
DIL1200 DIL1200 DIL1200 DIL1200
Interior duct size
7” (17.8 cm) 7” (17.8 cm) 10” (25.4 cm) 10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
Interior—Maximum amps
4.2/5.2/8.2 5.2/8.2 8.9 9.3
Exterior—Maximum amps
7.4/4.7 7.4/4.7/5.5 5.6/6.4 6.4/7.4
In-Line—Maximum amps
4.7/6.5 3.9/5.7 7.4 7.4
total Watts
47 Watts
Dimensions & Specifications
19
(VCIH /CVCIHChimney Island Hoods)
Clearance Dimensions
66” min.
(167.6 cm)
to
72” max.
(182.9 cm)
30” min.
(76.2 cm)
to
36” max.
(91.4 cm)
36”
(91.4 cm)
20
600 CFM Interior Ventilator Installation
for all Chimney Island Hoods
1200 CFM Interior Ventilator Installation
for all Chimney Island Hoods
Top View
Top View
(VCIH/CVCIH Chimney Island Hoods
)
Interior Ventilator Dimensions
12”
(30.5 cm)
A 36”W. 17-15/16” (45.6 cm) 42”W. 20-15/16” (53.2 cm)
B 36”W. 35-7/8” (91.1 cm) 42”W. 41-7/8” (106.4 cm)
A
6”
(15.2 cm)
7” (17.8 cm) dia. duct location
B
1-1/8”
(2.9 cm)
120 V
power
supply
1-1/8”
(2.9 cm)
A 54”W. 26-15/16” (68.4 cm) 66”W. 32-15/16” (83.7 cm)
B
54”W. 53-7/8” (136.8 cm) 66”W. 65-7/8” (167.3 cm)
C
54”W. 18” (45.7 cm) 66”W. 24” (61.0 cm)
6”
(15.2 cm)
C
A
10” (25.4 cm) dia. duct location
B
1-1/8”
(2.9 cm)
120 V power supply
1-1/8”
(2.9 cm)
21
900 or 1200 CFM Exterior or In-Line Ventilator Installation
for all Chimney Island Hoods
900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation
for all Chimney Island Hoods
Top View
Top View
(VCIH/CVCIH Chimney Island Hoods
)
Exterior Ventilator Dimensions
12”
(30.5 cm)
A 36”W. 17-15/16” (45.6 cm) 42”W. 20-15/16” (53.2 cm)
B 36”W. 35-7/8” (91.1 cm) 42”W. 41-7/8” (106.4 cm)
A
6”
(15.2 cm)
10” (25.4 cm) dia. duct location
B
1-1/8”
(2.9 cm)
120 V power supply
1-1/8”
(2.9 cm)
1-1/8”
(2.9 cm)
120 V power supply
1-1/8”
(2.9 cm)
A 54”W. 26-15/16” (68.4 cm) 66”W. 32-15/16” (83.7 cm)
B 54”W. 53-7/8” (136.8 cm) 66”W. 65-7/8” (167.3 cm)
C
54”W. 18” (45.7 cm) 66”W. 24” (61.0 cm)
C
A
6”
(15.2 cm)
10” (25.4 cm) dia. duct location
B
22
(VBCV Wall Custom Ventilator System 36”, 42”, 48”, & 60”)
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2­wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
Bottom Cutout Dimensions
*For best results, center the unit over the burners of the cooking product (front to back; right to left).
Wall Hoods
Description A (Hood Width) B (Hood Depth)
36” W. 33-7/16” (84.9 cm) 21-7/16” (54.5 cm) 42” W. 39-7/16” (100.2 cm) 21-7/16” (54.5 cm) 48” W. 45-7/16” (115.4 cm) 21-7/16” (54.5 cm) 60” W. 57-7/16” (145.9 cm) 21-7/16” (54.5 cm)
Make sure the back wall of the custom hood canopy is flush with the cutout so the ventilator system may be mounted as shown on page 25.
VBCV Wall Custom Ventilator System
Description 36” 42” 48” 60”
Number of lights
2 2 3 4
Number of filters
2 2 3 4
Heat lamps
1 1 2 3
Interior ventilator kits
VINV300/
600
VINV600 VINV1200* VINV1200*
Exterior ventilator kits
DEV900/
1200*
DEV900/
1200*
DEV1200*/
1500**
DEV1200*/
1500**
In-line ventilator kits
DIL1200 DIL900/1200 DIL1200 DIL1200
Interior duct size
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
Exterior duct size
10” (25.4
Interior—Maximum amps
4.2/5.2 10.8 10.8 10.8
Exterior—Maximum amps
8.0/5.3 8.0/5.3 7.8/8.5 7.8/8.5
In-Line—Maximum amps
5.3/7.2 5.3/7.2 9.6 10.0
Total Watts
47 Watts
Dimensions & Specifications
A*
B*
23
A
B
Custom Hood
Canopy
1) Position ventilator system inside of the custom hood canopy and center it front to back and left to right.
2) Bottom mounting holes fasten ventilator system to bottom of custom hood canopy with the screws provided.
Built-In Ventilator
System
3) OPTIONAL Rear mounting holes fasten ventilator system to rear of custom hood canopy.
(Custom Hood Canopy Cutouts)
Installing Hood Canopy
24
(VBCV/CVBCV Wall Custom Ventilator System)
Clearance Dimensions
(Custom Hood)
66" min.
(167.6 cm)
to
72" max.
(182.9 cm)
30" min.
(76.2 cm)
to
36" max.
(91.4 cm)
36"
(91.4 cm)
25
For 900, 1200 or 1500 CFM Exterior
or In-Line Ventilator Installation
For 300, 600 or 1200 CFM Interior
Ventilator Installation
900 or 1200 CFM Exterior
or In-Line Ventilator Installation
36”, 42” W. Models
300 or 600 CFM Interior
Ventilator Installation
36”, 42” W. Models
C
36” W. 34-1/4” (87.0 cm) 42” W. 40-1/4” (102.2 cm)
D
36” W. 17-1/8” (43.5 cm) 42” W. 20-1/8” (51.1 cm)
Built-In Wall Custom Ventilator System Dimensions
(VBCV Models)
1-1/2"
(3.81 cm)
5/8"
(1.6 cm)
21-7/8po (55.8 cm)
1"
(2.54 cm)
6”
(15.2 cm)
1-1/2”
(3.8 cm)
5/8”
(1.6 cm)
7/8”
(2.2 cm)
11-1/2”
(29.2 cm)
17-1/4”
(43.8 cm)
21-7/8”
(55.8 cm)
D
5-1/2"
(14.0 cm)
10" (25.4 cm)
dia. duct location
5/8" (1.6 cm)
C
D
4-5/8"
(11.7 cm)
7" (17.8 cm)
dia. duct location
5/8" (1.6 cm)
C
26
1200 or 1500 CFM Exterior or In-Line Ventilator Installation
48”, 60” W. Models
1200 CFM Interior Ventilator Installation
36”, 42”, 48”, 60” W. Models
C
36” W. 34-1/4” (87.0 cm) 42” W. 40-1/4” (102.2 cm) 48” W. 46-1/4” (117.5 cm) 60” W. 58-1/4” (148.0 cm)
D
36” W. 17-1/8” (43.5 cm) 42” W. 20-1/8” (51.1 cm) 48” W. 23-1/8” (58.7 cm) 60” W. 29-1/8” (74.0 cm)
Built-In Wall Custom Ventilator System Dimensions
(VBCV/CVBCV Models)
5-1/2"
(14.0 cm)
10" (25.4 cm)
dia. duct location
5/8" (1.6 cm)
D
C
5-1/2"
(14.0 cm)
10" (25.4 cm)
dia. duct location
5/8" (1.6 cm)
D
C
27
Proper installation of ducting is extremely important to ensure maximum performance from any ventilation product.
• All CFMs are based on tests at 0.1 static pressure: without applying static pressure, CFM would be greatly overstated.
• Straight runs and gradual turns are best; for example, each 90º elbow is equivalent to 5-10 feet (1.52-3.05 cm) of straight run.
• Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance.
• Proper performance is dependent on proper ducting; make sure that a qualified and trained installer is used.
• Check with a qualified and trained installer or local codes for makeup air requirement, if any.
• Max. amp rating for hoods includes recommended ventilator kit rating; all products must be hard wired direct with 2-wire with ground.
Plan where the duct work will be located. Install proper-sized duct work, and roof or wall cap for the type of blower you are using. Recommended hood locations for the most common installations are shown. Adjust your measurements for various heights of ceilings, soffits, cabinets, or ranges/rangetops.
Check Framing
NOTE: Because of the weight of the hood make sure that the mounting screws are driven into the framing and not just the drywall. It may be necessary to drill additional holes in the canopy for proper alignment.
p
Planning Information
Roof Cap
7 round duct
Roof cap
10 round duct
Exterior blower
10 round duct
300 or 600 CFM
single blower
interior-power
typical ductwork
Duct cover or soffit
Hood
1200 CFM
single blower
interior power
typical ductwork
Duct cover or soffit
Hood
900, 1200, or
1500 CFM
exterior power
typical ductwork
Duct cover or soffit
Hood
Wall Installation exterior
power typical
ductwork
Duct cover or soffit
Hotte
Wall Cap
Duct
NOTE: Wall exhaust must be a minimum of 24” (61.0 cm) from ground. This may vary depending on local codes and geogra
hic location.
28
Check damper for unrestricted movement, adjust if
necessary.
Attach transition to damper. Seal with aluminum tape.
Flip hood over and remove electrical box cover.
1
Insert 6” of electrical wiring through the top of vent hood
and secure using wiring restrain. Refer to local codes.
Slide duct over transition and tape around joint.
WARNING
To reduce the risk of fire, electric shock, or injury to persons, observe the following:
• Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
• Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Installation (VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator)
1
3
2
4
2
5
1
29
CAUTION: If not using a duct cover, using screws provided, make sure top mounting screws are secured into soffit or cabinet framing. Use additional mounting
screws, if necessary.
Connect black to black, white to white, and the
green/bare wire under the green screw.
NOTE: Housing wiring must be properly installed for
wiring to be correct when wiring unit.
5/16” Nut driver
Black
Black
White
White
Green
Bare or Green
Replace electrical box cover. Make connection to
breaker box.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
CAUTION: Secure vent hood to wall using screws
provided. Use additional mounting screws and wall
anchors, if necessary.
6
Nut driver 5/16”
3
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
7
9
1
8
1
1
2
10
1
1
2
3
2
30
1
2
Remove damper and discard with transition.
Turn recirculating unit upside down. Place vent hood
upside down on recirculating unit.
Installation
(VWH/CVWH 10”H./12”H. Wall Hoods w/Recirculating Kit)
2
Measure distance from ceiling to canopy.
Slide the duct cover in place and fasten from inside
canopy using the sheet metal screws provided.
Duct Cover Option
(VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator)
1
2
31
CAUTION: Secure vent hood. Make sure mounting
screws are secured into framing. Use additional mounting screws and wall anchors, if necessary.
7
5/16” Nut driver
Remove electrical box cover.
1
Flip hood over. Insert 6” of electrical wiring through the
top of vent hood and secure. Refer to local codes.
3
Attach with screws and lock washers provided.
Attach with screws.
WARNING
To reduce the risk of fire, electric shock, or injury to persons, observe the following:
• Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
• Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Installation
(VWH/CVWH 10”H./12”H. Wall Hoods w/Recirculating Kit)
4
5
6
2
32
Connect black to black, white to white, and the
green/bare wire under the green screw.
NOTE: Housing wiring must be properly installed for
wiring to be correct when wiring unit.
Replace electrical box cover. Make connection to
breaker box.
Assemble brackets to baffles and insert charcoal filters.
Black
Black
White
White
Green
Bare or Green
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
1
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
1
2
3
Slide spacer front over front lip. Push spacer rear up,
then slide back over rear lip.
1
2
3
Installation (con’t)
(VWH/CVWH 10”H./12”H. Wall Hoods w/Recirculating Kit)
8
10
9
1
1
2
11
2
12
13
3
33
1-13/16” (4.6 cm)
5/16” Nut driver
VWH/CVWH only! Measure down 1-13/16 (4.6 cm) from desired height of hood and secure 1-1/2” x 3/4” wood
strip (provided locally) to wall using screws provided.
VWH/CVWH only! Use additional mounting screws to
secure hood to wood strip.
5/16” Nut Driper
CAUTION: Secure vent hood to wall using screws
provided. Use additional mounting screws and wall
anchors, if necessary.
CAUTION: If not using a duct cover, using screws
provided, make sure top mounting screws are secured
into soffit or cabinet framing use additional mounting
screws, if necessary.
1
2
1
3
4
z
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Installation
(VWH/CVWH 18”H. Wall & VCWH Chimney Wall Hoods)
*For VCWH hoods, begin
with Step 3. The VCWH hoods do not require the wood strip
1
1-1/2” x 3/4”
(3.8 cm) x ( 1.9 cm)
wood strip
5/16” Nut driver
3
5/16” Nut driver
2
5
1
2
34
2
Measure distance from ceiling to canopy.
Slide the duct cover in place and fasten from inside
canopy using the sheet metal screws provided.
Duct Cover Option (VWH/CVWH 18”H. Wall Hoods)
1
To install ventillation kit
refer to ventillation kit
installation instructions.
2
35
2
Place duct cover top inside duct cover base and lower until
desired height is found. Mark height. Use the retaining
nuts and bolts to fasten in place and remove tape.
Slide the duct cover in place and fasten from inside
canopy using the sheet metal screws provided.
2
Measure distance from ceiling to canopy.
Tape to avoid scratching.
Duct Cover Option (VCWH/CVCWH Chimney Wall Hoods)
1
3
4
36
Check framing where cutout will be.
NOTE: 200 lb. limit
.
Cut appropriate size hole in ceiling. Either 7” or 10”
depending on your specific unit and ventillator kit.
1
Attach duct cover to optional ceiling mounting bracket.
Attach duct cover to ceiling. The ceiling bracket can be
hidden by using a locally supplied trim.
Additional support option. Drill holes in all four corners
for threaded rod and run rods from hood to ceiling.
Installation (VCIH/CVCIH Island Hoods)
2
Mounting options:
Using duct cover with ceiling mounting
bracket. (Option A - VCIH only)
Using threaded rod for additional support.
(Option B)
Attaching hood directly to soffit or
duct cover.
(Skip to step 3)
A2
5/16” Nut
Driver
A1
B1
37
5/16” Nut Driver
Attach canopy to duct cover/soffit. Seal top of hood to
duct with aluminum tape.
Run duct work down to bottom edge of duct
cover/soffit and secure in place. Make sure the duct
does not stick down past the cover.
Install larger center spacer in middle of canopy
Slide grease trough down into filter support with lip
facing upward
Attach long edge of side spacers to outer side of baffle
filters to installed next to canopy. Number of filters will vary due to size. Spacers only go on the (4) filters next to canopy.
Insert small center spacer (36” and 42” models only).
Slide top part of baffle filter up and under large center
spacer.
Push bottom of filter up and into grease trough.
Installation (VCIH/CVCIH Island Hoods)
3
5
La
rge Cent
er
Spacer
Grease Trough
4
To install ventillation kit
refer to ventillation kit
installation instructions.
Side spacer
Center spacer
38
If service is required, call your dealer or authorized service agency. The name of the authorized service agency can be obtained from the dealer or distributor in your area.
Have the following information readily available.
• Model number
• Serial number
• Date purchased
• Name of dealer from whom purchased
Clearly describe the problem that you are having. If you are unable to obtain the name of an authorized service agency, or if you continue to have service problems, contact Viking Range, LLC at 1-888-(845-4641), or write to:
VIKING RANGE, LLC
PREFERRED SERVICE
111 Front Street
Greenwood, Mississippi 38930 USA
Record the information indicated below. You will need it if service is ever required. The model and serial number for your hood is located behind the baffle filter on the left side panel in the lower right corner.
M o d e l n o . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ S e r i a l n o . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
D a t e o f p u r c h a s e _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ D a t e i n s t a l l e d _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
D e a l e r ’s n a m e _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Address _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
If service requires installation of parts, use only authorized parts to ensure protection under the warranty.
THIS MANUAL SHOULD REMAIN WITH THE HOOD FOR FUTURE REFERENCE.
Service & Registration
39
Viking Range, LLC
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information,
call 1-888-(845-4641)
or visit our web site at vikingrange.com
F21287F EN
(090118)
Loading...