Viking VCSB5483KA, VCSB5483FW, VCSB5483DG, VCSB5483CY, VCSB5483CS Installation Manual

...
Installation
GUIDE
5 SERIES
Side-by-Side Refrigerator/Freezer
VCSB5423 / VCSB5483 / FDSB5423 / FDSB5483
CVCSB5423 / CVCSB5483 / FDSB5423 / CFDSB5483
Table of Contents
2
IMPORTANT – Please Read and Follow!
• Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying voltage, frequency, wattage, amperage, and phase is attached to the product.
• To reduce the risk of  re, electrical shock, or injury to persons, installation work and electrical wiring must be done by a quali ed technician in accordance with all applicable codes and standards, including  re-rated construction.
• The installer should leave these instructions with the consumer who should retain them for local inspector’s use and for future reference.
Your safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. ALWAYS read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others.
All safety messages will be preceded by the safety alert symbol and the word “DANGER” or “WARNING.” These words mean:
DANGER
You will be killed or seriously injured if
you don't follow instructions.
WARNING
You can be killed or seriously injured if
you don't follow instructions.
All safety messages will identify the
hazard, tell you how to reduce the chance
of injury, and tell you what can happen if
the instructions are not followed.
33
IMPORTANT – Please Read and Follow!
A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or local
ordinances.
• The required use of a GFI is normally related to the location of a receptacle with respect to any signi cant sources of water or moisture.
• Viking Range, LLC will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below.
If the use of a GFI is required, it should be:
• Of the receptacle type (breaker type or portable type NOT recommended)
• Used with permanent wiring only (temporary or portable wiring NOT recommended)
• On a dedicated circuit (no other receptacles, switches or loads in the circuit)
• Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT recommended)
• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard)
• In good condition and free from any loose- tting gaskets (if applicable in outdoor situations)
• Protected from moisture (water, steam, high humidity) as much as reasonably possible
4
IMPORTANT – Please Read and Follow!
It is your responsibility to:
• comply with installation speci cations and dimensions.
• properly install unit.
• remove any moldings or decorative panels that prevent the unit from being serviced.
• make sure that you have these materials (not provided with your unit), which are necessary for proper installation:
• 1/4” (6 mm) copper tubing with shuto valve
• 6– #8 x 3” (7.6 cm) wood screws (longer screws may be required)
• 1– Saddle valve (do not use self-piercing feature of the valve)
• assure that  oor will support unit, door panels and contents (approximately 1200 pounds [540 kg]).
• provide a properly grounded electrical outlet.
• assure that location will permit appliance doors to open 90º minimum.
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power or turn
power disconnect switch to OFF position before removing top grille. Failure to do so can result in death or electrical shock.
is completely installed and secured per installation instructions.
Use two or more people to move and install appliance. Failure to do so can result in death or serious injury.
WARNING
TIP OVER HAZARD Appliance is top heavy and tips easily when not completely installed. Keep doors closed until appliance
Most of the unit’s weight is at the top. Extra care is needed when moving the unit to prevent
tipping. Use cardboard shipping material or plywood under unit until it is installed in the operating position to protect fl oor surface.
5
3–19/32”
42”
4
8”
(9.1 cm)
75–15/16”
(192.9 cm
Dimensions (Side-By-Side)
42” Side-By Side
41”
(104.1 cm)
42”
42”
(106.7 cm)
)
29-3/16”
(74.1 cm)
23–7/8”
(60.6 cm)
24-5/8”
(62.6 cm)
26-1/4”
(66.7 cm)
1–1/2”
m)
c
(3.8
9–5/32”
(23.3 cm)
82–3/4”
(210.2 cm)
m
84–1/16”
(213.5 cm)
max.
in.
to
3–19/32”
(9.1 cm)
75–15/16”
(192.9 cm
48” Side-By Side
47”
(119.4 cm)
48”
48”
(121.9 cm)
)
29-3/16”
(74.1 cm)
1–1/2”
m)
c
(3.8
9–5/32”
(23.3 cm)
82–3/4”
(210.2 cm)
m
in.
to
84–1/16”
(213.5 cm)
max.
Top View
29-3/16”
(74.1 cm)
6
26-1/4”
(66.7 cm)
23-7/8”
(60.6 cm)
23–7/8”
(60.6 cm)
24-5/8”
(62.6 cm)
26-1/4”
(66.7 cm)
Speci cations (Side-By-Side)
42” Side-By-Side
Description VCSB/CVCSB
Overall width 42” (106.7 cm)
Overall height (from bottom) 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max.
Overall depth from rear To front edge of side trim: 23-3/4 (60.3 cm)
To front of top grille: 26-1/4” (66.7cm)
To front of handle endcap: 29-3/16” (74.1 cm)
Cutout width 41-5/8” (105.7 cm) min. to 41-3/4” (106 cm) max.
Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max.
Standard Cutout depth 24” (61.0 cm) min.
Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.9 amps
Inlet water requirements 1/4” copper tubing inlet waterline; minimum 20 psi; maximum 120 psi Overall interior dimensions
Refrigerator Freezer Total capacity
Approximate shipping weight 525 lbs. (238 kg)
15.76 cu. ft. (446 liters)
9.56 cu. ft. (271 liters)
25.32 cu. ft. (717 liters)
48” Side-By-Side
Description VCSB/CVCSB
Overall width 48” (121.9 cm)
Overall height (from bottom) 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max.
Overall depth from rear To front edge of side trim: 23-3/4 (60.3 cm)
To front of top grille: 26-1/4” (66.7 cm)
To front of handle endcap: 29-3/16” (74.1 cm)
Cutout width 47-5/8” (121.0 cm) min. to 47-3/4” (121.3 cm) max.
Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max.
Standard Cutout depth 24” (61.0 cm) min.
Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.9 amps
Inlet water requirements 1/4” copper tubing inlet waterline; minimum 20 psi; maximum 120 psi Overall interior dimensions
Refrigerator Freezer Total capacity
Approximate shipping weight 580 lbs. (263 kg)
19.49 cu. ft. (552 liters)
9.56 cu. ft. (271 liters)
29.05 cu. ft. (823 liters)
7
3–19/32”
42”
48”
(9.1 cm)
75–15/16”
(192.9 cm
Dimensions
(Flush Mount Trim and Custom Door Overlay)
42” Side-By Side
with Flush Mount Trim
41”
(104.1 cm)
42”
42”
(106.7 cm)
)
29-3/16”
(74.1 cm)
23-7/8”
(60.6 cm)
24–5/8”
(62.6 cm)
26-1/4”
(66.7 cm)
1–1/2”
m)
c
(3.8
9–5/32”
(23.3 cm)
82–3/4”
(210.2 cm)
m
84–1/16”
(213.5 cm)
max.
3–19/32”
(9.1 cm)
in.
to
75–15/16”
(192.9 cm
48” Side-By Side
with Flush Mount Trim
47”
(119.4 cm)
48”
48”
(121.9 cm)
)
29-3/16”
(74.1 cm)
1–1/2”
m)
c
(3.8
9–5/32”
(23.3 cm)
82–3/4”
(210.2 cm)
m
in.
to
84–1/16”
(213.5 cm)
max.
Top View
29-3/16”
(74.1 cm)
26-1/4”
(66.6 cm)
8
25-1/2”
(64.8 cm)
23-7/8”
(60.6 cm)
24–5/8”
(62.6 cm)
26-1/4”
(66.7 cm)
Speci cations
(Flush Mount Trim and Custom Door Overlay)
42” Side-By-Side Flush Mount Trim and Custom Door Overlay
Description VCSB/CVCSB Flush Mount FDSB/CFDSB
Overall width 42” (106.7 cm)
Overall height (from bottom) 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max.
Overall depth from rear To front edge of side trim: 25-1/2" (64.8)
To front of top grille: 26-1/4” (66.7 cm)
To front of handle endcap: 29-3/16” (74.1 cm)
Cutout width 42” (106.7 cm)
Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max.
Flush Mount Cutout depth 26-1/2” (67.3 cm) min.
Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.9 amps
Inlet water requirements 1/4” copper tubing inlet waterline; minimum 20 psi; maximum 120 psi Overall interior dimensions
Refrigerator Freezer Total capacity
Maximum Panel WT Freezer Refrigerator
Approximate shipping weight 525 lbs. (238 kg)
N/A N/A
15.76 cu. ft. (446 liters)
9.56 cu. ft. (271 liters)
25.32 cu. ft. (717 liters)
30 lbs (13.6 kg) 38 lbs (17.2 kg)
48” Side-By-Side Flush Mount Trim and Custom Door Overlay
Description VCSB/CVCSB Flush Mount FDSB/CFDSB
Overall width 48” (121.9 cm)
Overall height (from bottom) 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max.
Overall depth from rear To front edge of side trim: 25-1/5" (64.8 cm)
To front of top grille: 26-1/4” (66.7 cm)
To front of handle endcap: 29-3/16” (74.1 cm)
Cutout width 48” (121.9 cm)
Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max.
Flush Mount Cutout depth 26-1/2” (67.3 cm) min.
Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.9 amps
Inlet water requirements 1/4” copper tubing inlet waterline; minimum 20 psi; maximum 120 psi Overall interior dimensions
Refrigerator Freezer Total capacity
Maximum Panel WT Freezer Refrigerator
Approximate shipping weight 580 lbs. (263 kg)
N/A N/A
9
19.49 cu. ft. (552 liters)
9.56 cu. ft. (271 liters)
29.05 cu. ft. (823 liters)
30 lbs (13.6 kg) 48 lbs (21.8 kg)
Cutout Dimensions
Standard Mount
24”
(61.0 cm)
42” Side-By-Side
Flush Mount
26-3/8”
(67.0 cm)
82–7/8”
(210.5 cm) min.
anti-tip board &
opening height
84–1/16”
(213.5 cm) max.
anti-tip board &
opening height
See Anti-Tip board installation
9”
(22.9 cm)
73-3/8”
(186.4 cm)
Electric Outlet Location
6”
(15.2 cm)
9”
(22.9 cm)
Water Line Entry Area
42”
(106.7 cm)
Flush Mount only
(106.0 cm) max.
(106
4
2”
.7 cm)
Flush Mount only
41–5/8”
(105.7 cm) min.
to
41–3/4”
10
3–5/8”
(9.2 cm)
(27.3 cm)
5/8”
(1.6 cm)
10–3/4”
water line entry
7–5/8”
(19.4 cm)
3”
(7.6 cm)
6–3/4”
(17.1 cm)
Optional floor
41–5/8”
(105.7 cm
10–1/2”
(26.7 cm)
)
5/8”
(1.6 cm)
(1.6 cm)
1”
(2.5 cm)
5/8”
Loading...
+ 22 hidden pages