Viking VCRB5363RSS, VCRB5363LPG, VCFB5363RCY, VCRB5363LAG, VCRB5363LBF Installation GUIDE

...
Installation
All Refrigerator / All Freezer
VCRB5303 / VCRB5363 / CVCRB5303 / CVCRB5363
VCFB5303 / VCFB5363 /CVCFB5303 / CVCFB5363
2
Table of Contents
Warnings & Important Information
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2
D i m e n s i o n s & S p e c i f i c a t i o n s ( 3 0 ” & 3 6 ” ) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 4 D i m e n s i o n s & S p e c i f i c a t i o n s ( 3 0 ” & 3 6 ” w i t h f l u s h m o u n t t r i m ) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 6 C u t o u t D i m e n s i o n s ( 3 0 ” ) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 8 A n t i - T i p D i m e n s i o n s ( 3 0 ” ) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 9 C u t o u t D i m e n s i o n s ( 3 6 ” ) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 0 A n t i - T i p D i m e n s i o n s ( 3 6 ” ) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 1 D i m e n s i o n s & S p e c i f i c a t i o n s ( D u a l 3 0 ” / D u a l 3 0 ” & 3 6 ” ) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 2 Dimensions & Specifications (Dual 30”/ Dual 30” & 36” with flush mount trim) _ _ _ _ _ _ _ _ _ 16 C u t o u t D i m e n s i o n s ( D u a l 3 0 ” ) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 0 A n t i - T i p D i m e n s i o n s ( D u a l 3 0 ” ) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 1 C u t o u t D i m e n s i o n s ( D u a l 3 0 ” & 3 6 ” ) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 2 A n t i - T i p D i m e n s i o n s ( D u a l 3 0 ” & 3 6 ” ) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 3 C u t o u t D i m e n s i o n s ( D u a l 3 6 ” ) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 4 A n t i - T i p D i m e n s i o n s ( D u a l 3 6 ” ) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 5 Cabinet Information _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 6
Cabinet Information (with flush mount trim) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 28 Custom Side Panel Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 0 Custom Side Panel Dimensions (with flush mount trim) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 31 General Information _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 3
U n p a c k i n g & M o v i n g _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 4 F l u s h M o u n t S i d e Tr i m I n s t a l l a t i o n _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 5 I n s t a l l a t i o n _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 5
H i n g e A d j u s t m e n t _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 6
K i c k p l a t e I n s t a l l a t i o n _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 8
Door Stop Adjustment _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 9
F i n a l I n s t a l l a t i o n _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 9 Performance Checklist _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 4 1 C o n t r o l P a n e l s _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 4 2 Service & Registration_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 4 3
Your safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others.
All safety messages will be preceded by the safety alert symbol and the word“DANGER” or “WARNING.”These words mean:
DANGER
You will be killed or seriously injured if you don’t follow instructions.
WARNING
You can be killed or seriously injured if you don’t follow instructions.
All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
3
IMPORTANT–Please Read and Follow!
• Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying
voltage, frequency, wattage, amperage, and phase is attached to the product.
• To reduce the risk of fire, electric shock, or injury to persons, installation work and electrical wiring
must be done by qualified people in accordance with all applicable codes and standards, including fire-rated construction.
• The installer should leave these instructions with the consumer who should retain them for local
inspector’s use and for future reference.
A GFI
shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or
local ordinances.
• The required use of a GFI is normally related to the location of a receptacle with respect to
any significant sources of water or moisture.
• Viking Range, LLC will NOT warranty any problems resulting from GFI outlets which are not
installed properly or do not meet the requirements below.
If the use of a GFI is required
, it should be:
• Of the receptacle type (breaker type or portable type NOT recommended)
• Used with permanent wiring only (temporary or portable wiring NOT recommended)
• On a dedicated circuit (no other receptacles, switches or loads in the circuit)
• Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT
recommended)
• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard)
• In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations)
• Protected from moisture (water, steam, high humidity) as much as reasonably possible
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power or turn power disconnect switch to OFF position before removing top grille. Failure to do so can result in death or electrical shock.
WARNING
TIP OVER HAZARD
Appliance is top heavy and tips easily when not completely installed. Keep doors closed until appliance is completely installed and secured per installation instructions.
Use two or more people to move and install appliance. Failure to do so can result in death or serious injury.
Most of the unit’s weight is at the top. Extra care is needed when moving the unit to prevent tipping. Use cardboard shipping material or plywood under unit until it is installed in the operating position to protect floor surface.
It is your responsibility to:
• comply with installation specifications and dimensions.
• properly install unit.
• remove any moldings or decorative panels that prevent the unit from being serviced.
• make sure that you have these materials (not provided with your unit), which are necessary
for proper installation:
• 1/4” (6 mm) copper tubing with shutoff valve
• 6– #8 x 3” (7.6 cm) wood screws (longer screws may be required)
• 1– Saddle valve (do not use self-piercing feature of the valve)
• assure that floor will support unit, door panels and contents (approximately 1200 pounds [540 kg]).
• provide a properly grounded electrical outlet.
• assure that location will permit appliance doors to open 90° minimum.
36”
(
91.
5 cm)
3–19/32”
30”
(76.2 cm)
4
30” All Refrigerator/All Freezer
36” All Refrigerator/All Freezer
Dimensions
(9.1 cm)
29”
30”
30”
(76.2 cm)
(76.2 cm)
(73.7 cm)
75–15/16”
(192.9 cm
)
26-1/2”
(67.3 cm)
9–5/32”
(23.3 cm)
82–3/4”
(210.2 cm)
min.
to
84–1/16”
(213.5 cm)
max.
3–19/32”
(9.1 cm)
)
75–15/16”
(192.9 cm)
35”
(88.9 cm)
36”
36”
(91.5 cm)
(91.5 cm)
82–3/4”
(210.2 cm)
26-1/2”
(67.3 cm)
84–1/16”
(213.5 cm)
9–5/32”
(23.3 cm)
min.
to
max.
0–3/4
2
(52.7 cm)
22–3/16”
(56.4 cm)
24”
(61.0 cm)
4
0–3/
2
(52.7 cm)
22–3/16”
(56.4 cm)
24”
(61.0 cm)
5
30” All Refrigerator/All Freezer
Description VCFB/CVCFB VCRB/CVCRB
Overall width 30” (76.2 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 22-3/16” (56.4 cm)
To front of top grille: 24” (61.0 cm) To front of handle endcap: 26-1/2” (67.3 cm)
Cutout width 29-5/8” (75.2 cm) min. to 29-3/4” (75.6 cm) max. Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.1 amps 5.7 amps Inlet water requirements 1/4” copper tubing inlet
waterline; minimum 20 psi; N/A
maximum 120 psi
Overall interior dimensions Total capacity 15.9 cu. ft. (450 liters) 17.8 cu. ft. (504 liters)
Approximate shipping weight 550 lbs. (247.5 kg) 525 lbs. (236.3 kg)
36” All Refrigerator/All Freezer
Description VCFB/CVCFB VCRB/CVCRB
Overall width 36” (91.5 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 22-3/16” (56.4 cm)
To front of top grille: 24” (61.0 cm) To front of handle endcap: 26-1/2” (67.3 cm)
Cutout width 35-5/8” (90.5 cm) min. to 35-3/4” (90.8 cm) max. Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.5 amps 6.5 amps Inlet water requirements 1/4” copper tubing inlet
waterline; minimum 20 psi; N/A
maximum 120 psi
Overall interior dimensions Total capacity 19.2 cu. ft. (544 liters) 22.0 cu. ft. (623 liters) Approximate shipping weight 605 lbs. (272.3 kg) 590 lbs. (265.5 kg)
Specifications
36”
(91
.5 cm)
3–19/32”
30”
(76.2 cm)
6
30” All Refrigerator/All Freezer
with Flush Mount Trim
36” All Refrigerator/All Freezer
with Flush Mount Trim
Note: Flush Mount Trim (PBIRFTKSS) purchased separately.
Dimensions
(9.1 cm)
29”
30”
30”
(76.2 cm)
(76.2 cm)
(73.7 cm)
75–15/16”
(192.9 cm
)
26–1/2”
(67.3 cm)
9–5/32”
(23.3 cm)
82–3/4”
(210.2 cm)
min.
to
84–1/16”
(213.5 cm)
max.
3–19/32”
(9.1 cm)
75–15/16”
(192.9 cm)
35”
(88.9 cm)
36”
36”
(91.5 cm)
(91.5 cm)
26–1/2”
(67.3 cm)
9–5/32”
(23.3 cm)
82–3/4”
(210.2 cm)
min.
to
84–1/16”
(213.5 cm)
max.
0–3/4
2
(52.7 cm)
23–3/8”
(59.4 cm)
24”
(61.0 cm)
0–3/4
2
(52.7 cm)
23–3/8”
(59.4 cm)
24”
(61.0 cm)
7
30” All Refrigerator/All Freezer with Flush Mount Trim
Description VCFB/CVCFB Flush Mount VCRB/CVCRB Flush Mount
Overall width 30” (76.2 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8” (59.4 cm)
To front of top grille: 24” (61.0 cm) To front of handle endcap: 26-1/2” (67.3 cm)
Cutout width 30” (74.9 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.1 amps 5.7 amps Inlet water requirements 1/4” copper tubing inlet
waterline; minimum 20 psi; N/A
maximum 120 psi
Overall interior dimensions Total capacity 15.9 cu. ft. (450 liters) 17.8 cu. ft. (504 liters)
Approximate shipping weight 550 lbs. (247.5 kg) 525 lbs. (236.3 kg)
36” All Refrigerator/All Freezer with Flush Mount Trim
Description VCFB/CVCFB Flush Mount VCRB/CVCRB Flush Mount
Overall width 36” (91.5 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8” (59.4 cm)
To front of top grille: 24” (61.0 cm) To front of handle endcap: 26-1/2” (67.3 cm)
Cutout width 36” (91.4 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.5 amps 6.5 amps Inlet water requirements 1/4” copper tubing inlet
waterline; minimum 20 psi; N/A
maximum 120 psi
Overall interior dimensions Total capacity 19.2 cu. ft. (544 liters) 22.0 cu. ft. (623 liters)
Approximate shipping weight 605 lbs. (272.3 kg) 590 lbs. (265.5 kg)
Specifications
8
30” All Refrigerator/All Freezer
Cutout Dimensions
24”
(61.0 cm)
82–7/8”
(210.5 cm) min.
anti-tip board &
opening height
84–1/16”
(213.5 cm) max.
anti-tip board &
opening height
See Anti-Tip board installation
(22.9 cm)
73–3/8”
(186.4 cm)
9”
Electric Outlet Location
6”
(15.2 cm)
9”
(22.9 cm)
Water Line Entry Area
Note: Shown for All Freezer Only
30”
(76.2 cm)
Flush Mount only
29-3/4”
(75.6 cm) max.
(76.
3
0”
2 cm)
Flush Mount only
29–5/8”
(75.2 cm) min.
to
3–5/8”
(9.2 cm)
(27.3 cm)
5/8”
(1.5 cm)
10–3/4”
water line entry
29–5/8”
7–5/8”
(75.2 cm)
(19.4 cm)
3”
(7.6 cm)
6–3/4”
(17.1 cm)
Optional floor
10–1/2”
(26.7 cm)
5/8”
(1.5 cm)
5/8”
(1.5 cm)
1”
(2.5 cm)
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
Note: Top of unit must be placed firmly under anti-tip board.
Anti-Tip Location
Flush Mount Anti-Tip Location
NOTE: If unit is installed deeper than
24” (61.0 cm),then shim behind the mounting
board by the difference.
NOTE: If unit is installed deeper than
24” (61.0 cm), then shim behind the mounting
board by the difference.
Two 2”x 4” mounting boards
3” (7.6 cm) x 3-1/2” (8.9 cm)
One 2”x 4” mounting board
1–1/2” (3.8 cm) x 3-1/2” (8.9 cm)
79–3/8”
(201.6 cm) min.
to bottom of anti-tip board
80–1/2”
(204.6 cm) max.
to bottom of anti-tip board
23”
(58.4 cm)
3–1/2”
(8.9 cm)
3”
(7.6 cm)
23”
(58.4 cm)
3–1/2”
(8.9 cm)
1–1/2”
(3.8 cm)
9
30” All Refrigerator/All Freezer
Anti-Tip Dimensions
10
36” All Refrigerator/All Freezer
Cutout Dimensions
24”
(61.0 cm)
82–7/8”
(210.5 cm) min.
anti-tip board &
opening height
84–1/16”
(213.5 cm) max.
anti-tip board &
opening height
See Anti-Tip board installation
9”
(22.9 cm)
73–3/8”
(186.4 cm)
Electric Outlet Location
6
(15.2 cm)
9
(22.9 cm)
Water Line Entry Area
Note: Shown for All Freezer Only
36”
(91.4 cm)
Flush Mount only
(90.8 cm) max.
(9
1.4 cm)
36”
Flush Mount only
35–5/8”
(90.5 cm) min.
to
35-3/4”
3–5/8”
(9.2 cm)
(27.3 cm)
5/8”
(1.5 cm)
10–3/4”
water line entry
35–5/8”
7–5/8”
(19.4 cm)
3”
(7.6 cm)
(90.5 cm)
6–3/4”
(17.1 cm)
Optional floor
10–1/2”
(26.7 cm)
5/8”
(1.5 cm)
(1.5 cm)
1”
(2.5 cm)
5/8”
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
Note: Top of unit must be placed firmly under anti-tip board.
79–3/8”
(201.6 cm) min.
to bottom of
anti-tip board
80–1/2”
(204.6 cm) max.
to bottom of
anti-tip board
Anti-Tip Location
Flush Mount Anti-Tip Location
NOTE: If unit is installed deeper than
24” (61.0 cm), then shim behind the mounting
board by the difference.
NOTE: If unit is installed deeper than
24” (61.0 cm), then shim behind the mounting
board by the difference.
Two 2”x 4” mounting boards
3” (7.6 cm) x 3-1/2” (8.9 cm)
One 2”x 4” mounting board
1–1/2” (3.8 cm) x 3–1/2” (8.9 cm)
29–1/2”
(74.9 cm)
3–1/2”
(8.9 cm)
3”
(7.6 cm)
29–1/2”
(74.9 cm)
3–1/2”
(8.9 cm)
1–1/2”
(3.8 cm)
11
36” All Refrigerator/All Freezer
Anti-Tip Dimensions
30
(76.2 cm)
30
(76.2 cm)
12
Dual 30” All Refrigerator/All Freezer*
Dimensions
*Shown with optional one-piece grille kit
3–19/32
(9.1 cm)
(76.2 cm)
30
(76.2 cm)
30
29
(73.7 cm)
30
30
(76.2 cm)
(76.2 cm)
29
(73.7 cm)
75–15/16
(192 .9 cm
9–5/32
(23.3 cm)
)
82–3/4
(210.2 cm)
min.
to
26-1/2
(67.3 cm)
84–1/16
(213.5 cm)
max.
1
(2.54 cm)
Between Units
20–3/4
cm)
(52.7
22–3/16
(56.4 cm)
24
(61.0 cm)
30
(76.2 cm)
13
Dual 30” & 36” All Refrigerator/All Freezer*
Dimensions
*Shown with optional one-piece grille kit
29
(73.6 cm)
3–19/32
(9.1 cm)
75–15/16
(192 .9 cm
30
(76.2 cm)
30
(76.2 cm)
36
(91.5 cm)
35
(88.9 cm)
9–5/32
(23.3 cm)
)
82–3/4
(210.2 cm)
26-1/2
(67.3 cm)
min.
to
84–1/16
(213.5 cm)
max.
1
(2.54 cm)
Between Units
20–3/4
(52.7 cm)
22–3/16
(56.4 cm)
24
(61.0 cm)
30
(76.2 cm)
30
(76.2 cm)
14
Dual 36” All Refrigerator/All Freezer*
Dimensions
*Shown with optional one-piece grille kit
3–19/32
(9.1 cm)
(76.2 cm)
30
36
(91.5 cm)
35
(88.9 cm)
30
36
(76.2 cm)
(91.5 cm)
35
(88.9 cm)
75–15/16
(192 .9 cm
9–5/32
)
(23.3 cm)
82–3/4
(210.2 cm)
min.
to
26-1/2
(67.3 cm)
84–1/16
(213.5 cm)
max.
1
(2.54 cm)
Between Units
20–3/4
(52.7 cm)
22–3/16
(56.4 cm)
24
(61.0 cm)
Loading...
+ 30 hidden pages