Viking VBI7360WRWH, VBI7360WLWH, VBI7360WLSS, VBI7360WRSS, MVBI7360WRSS Installation Guide

...
0 (0)

Installation

Guide

Integrated Refrigerator / Freezer

7 SERIES

VBI7360 / CVBI7360

FBI7360 / CFBI7360

MVBI7360 / CMVBI7360

MFBI7360 / CMFBI7360

Table of Contents

Warnings and Important Information _______________________________________________________ 3 Professional Bottom-Freezer

Dimensions _______________________________________________________________________ 5 Specifications ______________________________________________________________________ 6 Cutout Dimensions__________________________________________________________________ 7 Anti-Tip Dimensions (36”) ____________________________________________________________ 9

General Information

Electrical Requirements _____________________________________________________________ 10 Water Requirements________________________________________________________________ 11 Unpacking & Moving ___________________________________________________________________ 12

Installation

Door/Drawer Panel Adjustments______________________________________________________ 12 Custom Front Panel Dimensions ______________________________________________________ 13 Custom Front Panel Install ___________________________________________________________ 14 Water Line Installation ______________________________________________________________ 15 Leveling Unit______________________________________________________________________ 17 Kickplate Installation _______________________________________________________________ 17 Flush Mount Side Trim ______________________________________________________________ 18 Door Stop Adjustment ______________________________________________________________ 19 System Specifications and Data_______________________________________________________ 21

Performance Checklist __________________________________________________________________ 21 Control Panels_________________________________________________________________________ 21 Service & Registration __________________________________________________________________ 22

2

IMPORTANT Please Read and Follow!

Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying voltage, frequency, wattage, amperage, and phase is attached to the product.

To reduce the risk of fire, electrical shock, or injury to persons, installation work and electrical wiring must be done by

a qualified technician in accordance with all applicable codes and standards, including fire-rated construction.

The installer should leave these instructions with the consumer who should retain them for local inspector’s use and for future reference.

Your safety and the safety of others is very important.

We have provided many important safety messages in this manual and on your appliance. ALWAYS read and obey all safety messages.

This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others.

All safety messages will be preceded by the safety alert symbol and the word “DANGER” or “WARNING.” These words mean:

For additional information or installation videos, visit our website at www. vikingrange.com in the US or brigade.ca in Canada.

It is your responsibility to:

DANGER

You will be killed or seriously injured if you don't follow instructions.

WARNING

You can be killed or seriously injured if you don't follow instructions.

All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

comply with installation specifications and dimensions.

properly install unit.

remove any moldings or decorative panels that prevent the unit from being serviced.

make sure that you have these materials (not provided with your unit), which are necessary for proper installation:

1/4” (6 mm) copper tubing with shutoff valve

1– Saddle valve (do not use self-piercing feature of the valve)

assure that floor will support unit, door panels and contents (approximately 1200 pounds [540 kg]).

provide a properly grounded electrical outlet.

assure that location will permit appliance doors to open 90º minimum.

Required tools

Drill

Drill bits - 3" Phillips (Ph2), Torx (T15 & T20), 1/4" and 5/16" hex drive

Rubber mallet

3/8" wrench

3

IMPORTANT Please Read and Follow!

A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or local ordinances.

The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture.

Viking Range, LLC will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below.

If the use of a GFI is required, it should be:

Of the receptacle type (breaker type or portable type NOT recommended)

Used with permanent wiring only (temporary or portable wiring NOT recommended)

On a dedicated circuit (no other receptacles, switches or loads in the circuit)

Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT recommended)

Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard)

In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations)

Protected from moisture (water, steam, high humidity) as much as reasonably possible

WARNING

ELECTRICAL SHOCK HAZARD

Disconnect power or turn power disconnect switch to OFF position before removing

top grille. Failure to do so can result in death or electrical shock.

WARNING

TIP OVER HAZARD

Appliance is top heavy and tips

easily when not completely installed. Keep doors closed until appliance is completely installed

and secured per installation instructions.

Use two or more people to move and install appliance. Failure to do so can result in death or serious injury.

access panel

Power On/Off Switch

Your unit is shipped with the power switch on. When first plugged in, the display will flash. Push any button to initiate display.

The power on/off switch is located to the left of the center behind the access panel. It is used to turn the power off when cleaning or servicing the refrigerator.

To turn power off, remove the access panel. Press the power on/off switch to the off position.

To turn power on, press power on/off switch to the on position. Replace access panel.

B

4

Dimensions (Integrated Bottom-Freezer)

36” (91.4 cm)

50-1/2”

(128.3 cm)

83-15/16”

(213.2 cm)

12-1/8”

(30.8 cm)

17-1/16”

(43.3 cm)

4-1/16” (10.3 cm)

22-1/2”

(57.2

cm)

 

24-5/8”

(62.5

cm)

 

27-3/8”

(69.5

cm)

 

 

Model

Dimension A

Dimension B*

 

 

 

VBI7360/CVBI7360

27-3/8" (69.5 cm)

24-3/4" (62.9 cm)

FBI7360/CFBI7360

N/A

24" (61.0 cm)

 

 

MVBI7360/CMVBI7360

27" (68.5 cm)

24-3/4" (62.9 cm)

*To outside of door panel

5

Specifications (Integrated Bottom-Freezer)

36” Integrated Refrigerator/Freezer

Description

VBI7360 / CVBI7360

 

MVBI7360 / CMVBI7360

 

 

 

 

Overall width

36" (91.4 cm)

 

 

 

 

Overall height (from bottom)

83-15/16" (213.2 cm) min to 84-3/4" (215.7 cm) max

 

 

 

Overall depth from rear

To front edge kickplate: 22-1/2” (57.2 cm)

 

To front of door panel: 24-3/4” (62.9 cm)

 

 

 

 

 

To front of handle endcap:

 

To front of handle endcap:

 

27-3/8" (69.5 cm)

 

27" (68.5 cm)

 

 

 

 

Cutout width

36" (91.4 cm)

 

 

 

Cutout height

84-3/16" (213.8 cm) min to 85-3/16" (216.3 cm) max

 

 

Cutout depth

25” (63.5 cm) min.

 

 

Electrical requirements

115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with

 

grounded 3-prong plug attached to product

 

 

 

Maximum amp usage

9.9 amps

 

 

 

Inlet water requirements

1/4” copper tubing inlet waterline; minimum 20 psi;

 

maximum 120 psi

 

 

 

 

Overall interior dimensions

 

 

 

Refrigerator

13.6 cu. ft. (385.8 liters)

Freezer

6.35 cu. ft. (180.1 liters)

Total capacity

19.95 cu. ft. (565.9 liters)

 

 

Approximate shipping weight

565 lbs. (254.3 kg)

 

 

 

 

36” Integrated Refrigerator/Freezer w/Custom Panels

Description

FBI7360 / CFBI7360

 

 

Overall width

36" (91.4 cm)

 

 

Overall height (from bottom)

83-15/16" (213.2 cm) min to 84-3/4" (215.7 cm) max

 

 

Overall depth from rear

To front edge kickplate: 22-1/2” (57.2 cm)

 

To front of door panel: 24” (61.0 cm)

 

 

Cutout width

36" (91.4 cm)

 

 

Cutout height

84-3/16" (213.8 cm) min to 85-3/16" (216.3 cm) max

 

 

Cutout depth

25” (63.5 cm) min.

 

 

Electrical requirements

115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with

 

grounded 3-prong plug attached to product

 

 

Maximum amp usage

9.9 amps

 

 

Inlet water requirements

1/4” copper tubing inlet waterline; minimum 20 psi;

 

maximum 120 psi

 

 

Overall interior dimensions

 

Refrigerator

13.6 cu. ft. (385.8 liters)

Freezer

6.35 cu. ft. (180.1 liters)

Total capacity

19.95 cu. ft. (565.9 liters)

 

 

Approximate shipping weight

565 lbs. (254.3 kg)

6

Cutout Dimensions (Bottom-Freezer)

25”

 

 

(63

.5 cm)

Can

 

 

 

 

be located

 

 

 

on either

 

 

 

side

 

84-3/16”

 

 

 

 

*

(21384

cm)

 

 

 

opening

 

 

min.

 

 

 

 

height

 

85-

 

 

 

 

 

 

 

 

3/16”

 

(216.

 

 

 

3cm)

 

 

 

 

 

opening

 

max.

 

 

 

 

 

height

Electric Outlet Location

15-

 

 

 

 

1/2”

 

(39.4

cm)

 

 

 

 

 

 

4-1/4”

 

 

 

 

(10.8

cm)

 

+

 

 

 

 

 

leveling

 

 

 

dimension

(91.

3

 

6”

5

cm)

 

 

*Note: For all models, 3” back from the front of the cabinet on both sides needs to finished like the outside of the cabinets

Water Line Entry Area

 

 

 

 

 

36”

 

 

 

 

 

 

 

 

(91.

 

 

 

 

 

 

 

 

 

5

cm)

 

 

 

 

 

 

 

 

 

 

 

 

5/8”

 

 

 

 

 

 

 

 

(1.

 

 

 

 

 

 

 

 

 

6

cm)

1/2”

 

 

 

3”

 

 

 

(7.

 

 

(1.

3

cm)

 

 

6

cm)

 

 

 

 

 

6”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(15.

 

 

 

 

 

 

 

 

 

2

cm)

 

 

 

 

 

 

 

 

 

 

 

7

Viking VBI7360WRWH, VBI7360WLWH, VBI7360WLSS, VBI7360WRSS, MVBI7360WRSS Installation Guide

Tipping Radius

 

9-1/2"

 

(24.1 cm)

 

37-1/4"

 

(94.6 cm)

 

39-5/16"

 

(99.8 cm)

1050

900

127-3/16" (323.1 cm)

36" (94.4 cm)

91-7/16"

(232.3 cm)

83-15/16"

(213.2 cm)

111-3/16" (323.1 cm)

24-5/8"

(62.5 cm)

87-3/4"

(222.9 cm) 83-15/16"

(213.2 cm)

17-1/4"

(43.8 cm)