Viking VBI7360WLPG, VBI7360WRKA, VBI7360WLKA, VBI7360WRFW, VBI7360WLFW Installation Manual

...
Installation
Guide
Integrated Refrigerator / Freezer
7 SERIES
VBI7360 / CVBI7360
FBI7360 / CFBI7360
MVBI7360 / CMVBI7360
MFBI7360 / CMFBI7360
Table of Contents
Warnings and Important Information _______________________________________________________ 3
Professional Bottom-Freezer
Dimensions _______________________________________________________________________ 5
Speci cations ______________________________________________________________________ 6
Cutout Dimensions__________________________________________________________________ 7
Anti-Tip Dimensions (36”) ____________________________________________________________ 9
General Information
Electrical Requirements _____________________________________________________________ 10
Water Requirements ________________________________________________________________ 11
Unpacking & Moving ___________________________________________________________________ 12
Installation
Door/Drawer Panel Adjustments ______________________________________________________ 12
Custom Front Panel Dimensions ______________________________________________________ 13
Custom Front Panel Install ___________________________________________________________ 14
Water Line Installation ______________________________________________________________ 15
Leveling Unit ______________________________________________________________________ 17
Kickplate Installation _______________________________________________________________ 17
Flush Mount Side Trim ______________________________________________________________ 18
Door Stop Adjustment ______________________________________________________________ 19
System Speci cations and Data _______________________________________________________ 21
Performance Checklist __________________________________________________________________ 21
Control Panels _________________________________________________________________________ 21
Service & Registration __________________________________________________________________ 22
IMPORTANT – Please Read and Follow!
• Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying voltage, frequency, wattage, amperage, and phase is attached to the product.
• To reduce the risk of  re, electrical shock, or injury to persons, installation work and electrical wiring must be done by a quali ed technician in accordance with all applicable codes and standards, including  re-rated construction.
• The installer should leave these instructions with the consumer who should retain them for local inspector’s use and for future reference.
For additional information or installation videos, visit our website at www. vikingrange.com
Your safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. ALWAYS read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others.
All safety messages will be preceded by the safety alert symbol and the word “DANGER” or “WARNING.” These words mean:
DANGER
You will be killed or seriously injured if you
don't follow instructions.
WARNING
You can be killed or seriously injured if you
don't follow instructions.
All safety messages will identify the
hazard, tell you how to reduce the chance
of injury, and tell you what can happen if
the instructions are not followed.
It is your responsibility to:
• comply with installation speci cations and dimensions.
• properly install unit.
• remove any moldings or decorative panels that prevent the unit from being serviced.
• make sure that you have these materials (not provided with your unit), which are necessary
for proper installation:
• 1/4” (6 mm) copper tubing with shuto valve
• 1– Saddle valve (do not use self-piercing feature of the valve)
• assure that  oor will support unit, door panels and contents (approximately
1200 pounds [540 kg]).
• provide a properly grounded electrical outlet.
• assure that location will permit appliance doors to open 90º minimum.
Required tools
Drill
Drill bits - 3" Phillips (Ph2), Torx (T15 & T20), 1/4" and 5/16" hex drive
Rubber mallet
3/8" wrench
IMPORTANT – Please Read and Follow!
A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or local
ordinances.
• The required use of a GFI is normally related to the location of a receptacle with respect to any signi cant sources of water or moisture.
• Viking Range, LLC will installed properly or do not meet the requirements below.
If the use of a GFI is required, it should be:
• Of the receptacle type (breaker type or portable type
• Used with permanent wiring only (temporary or portable wiring
• On a dedicated circuit (no other receptacles, switches or loads in the circuit)
• Connected to a standard breaker of appropriate size (GFI breaker of the same size recommended)
• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard)
• In good condition and free from any loose- tting gaskets (if applicable in outdoor situations)
• Protected from moisture (water, steam, high humidity) as much as reasonably possible
NOT warranty any problems resulting from GFI outlets which are not
NOT recommended)
NOT recommended)
NOT
WARNING
ELECTRICAL SHOCK HAZARD Disconnect power or turn power disconnect switch to
OFF position before removing top grille. Failure to do so can result in death or electrical shock.
Power On/O Switch
Your unit is shipped with the power switch on. When  rst plugged in, the display will  ash. Push any button to initiate display.
The power on/o switch is located to the left of the center behind the access panel. It is used to turn the power o when cleaning or servicing the refrigerator.
To turn power o , remove the access panel. Press the power on/o switch to the o position.
To turn power on, press power on/o switch to the on position. Replace access panel.
and secured per installation instructions.
Use two or more people to move and install appliance. Failure to do so can result in death or serious injury.
WARNING
TIP OVER HAZARD Appliance is top heavy and tips easily when not completely installed. Keep doors closed until appliance is completely installed
access panel
B
Dimensions (Integrated Bottom-Freezer)
83-15/16”
(213.2 cm)
36”
(91.4 cm)
50-1/2”
(128.3 cm)
22-1/2”
(57.2 cm)
B*
A
Model Dimension A Dimension B*
VBI7360/CVBI7360
FBI7360/CFBI7360
MVBI7360/CMVBI7360
12-1/8”
(30.8 cm)
17-1/16”
(43.3 cm)
4-1/16” (10.3 cm)
27-3/8" (69.5 cm) 24-3/4" (62.9 cm)
N/A 24" (61.0 cm)
27" (68.5 cm) 24-3/4" (62.9 cm)
*To outside of door panel
5
Speci cations (Integrated Bottom-Freezer)
36” Integrated Refrigerator/Freezer
Description VBI7360 / CVBI7360 MVBI7360 / CMVBI7360
Overall width 36" (91.4 cm)
Overall height (from bottom) 83-15/16" (213.2 cm) min to 84-3/4" (215.7 cm) max
Overall depth from rear To front edge kickplate: 22-1/2” (57.2 cm)
To front of door panel: 24-3/4” (62.9 cm)
To front of handle endcap:
27-3/8" (69.5 cm)
Cutout width 36" (91.4 cm)
Cutout height 84" (213.4 cm) min to 85-3/16" (216.3 cm) max
Cutout depth 25” (63.5 cm) min.
Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.9 amps
Inlet water requirements 1/4” copper tubing inlet waterline; minimum 20 psi;
maximum 120 psi
Overall interior dimensions Refrigerator Freezer Total capacity
Approximate shipping weight 565 lbs. (254.3 kg)
13.6 cu. ft. (385.8 liters)
6.35 cu. ft. (180.1 liters)
19.95 cu. ft. (565.9 liters)
To front of handle endcap:
27" (68.5 cm)
36” Integrated Refrigerator/Freezer w/Custom Panels
Description FBI7360 / CFBI7360
Overall width 36" (91.4 cm)
Overall height (from bottom) 83-15/16" (213.2 cm) min to 84-3/4" (215.7 cm) max
Overall depth from rear To front edge kickplate: 22-1/2” (57.2 cm)
To front of door panel: 24” (61.0 cm)
Cutout width 36" (91.4 cm)
Cutout height 84" (213.4 cm) min to 85-3/16" (216.3 cm) max
Cutout depth 25” (63.5 cm) min.
Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.9 amps
Inlet water requirements 1/4” copper tubing inlet waterline; minimum 20 psi;
maximum 120 psi
Overall interior dimensions Refrigerator Freezer Total capacity
Approximate shipping weight 565 lbs. (254.3 kg)
13.6 cu. ft. (385.8 liters)
6.35 cu. ft. (180.1 liters)
19.95 cu. ft. (565.9 liters)
6
Cutout Dimensions (Bottom-Freezer)
25”
(63.5 cm)
(213.4 cm) min.
opening height
*
85-3/16”
(216.3cm) max.
opening height
84”
Can be located on either side
Electric Outlet Location
15-1/2”
(39.4 cm)
4-1/4”
(10.8 cm)
+
leveling
dimension
Water Line Entry Area
36”
(91.5 cm)
36”
(91.5 cm)
*Note: For all models, 3” back from the front of the cabinet on both sides needs to  nished like the outside of the cabinets
5/8”
(1.6 cm)
7
1/2”
(1.3 cm)
6”
(15.2 cm)
3”
(7.6 cm)
Tipping Radius
9-1/2"
(24.1 cm)
(94.6 cm)
105
90
37-1/4"
39-5/16"
(99.8 cm)
36" (94.4 cm)
127-3/16" (323.1 cm)
91-7/16"
(232.3 cm)
87-3/4"
(222.9 cm)
111-3/16" (323.1 cm)
83-15/16"
(213.2 cm)
24-5/8"
(62.5 cm)
83-15/16"
(213.2 cm)
17-1/4"
(43.8 cm)
8
Loading...
+ 16 hidden pages