Viking VBCV36381, VBCV48381, VBCV60381, VWH 10”H, VWH 18”H Installation Instructions Manual

...
F20470I EN
(082012)
Viking Installation Guide
Professional &
Outdoor Hoods
Viking Range Corporation
111 Front Street
(662) 455-1200
For product information,
call 1-888-VIKING1 (845-4641)
or visit the Viking Web site at
vikingrange.com
Table of Contents
3
IMPORTANT–Please Read and Follow!
NOTE:
If installing hood with warming shelf panel,
install warming shelf panel first.
IMPORTANT – PLEASE READ AND FOLLOW
• Before beginning, please read these instructions completely and carefully.
• Do not remove permanently affixed labels, war nings, or plates from the product. This may void the warranty.
• Please observe all local and national codes and ordinances. If no local codes are applicable, wire in accordance with the National Electrical Code, ANSI/NFPA 70-latest edition.
• Damp environment approved models should be installed in a covered non-enclosed area and should be protected from the elements as much as possible.
• The installer should leave these instructions with the consumer who should retain for local inspector’s use and for future reference.
• Check with a qualified and trained installer or local codes for makeup air requirement, if any.
This hood is for residential installation only and is not designed for installation over a commercial product. Make sure power is off at the main circuit breaker or fuse box before making connections. To avoid risk of fire, electric shock, or injury to persons, turn off the electricity to the hood from the power supply before servicing or cleaning. Viking hoods are equipped with variable speed control blowers. These units will not function with a single speed ventilator. All Viking Range ventilator kits are designed specifically for use with Viking Range hoods. Use of any non-Viking Range ventilator kit will void the hood warranty.
Viking hoods are equipped with the variable speed controls for blowers. These units will not function with a single speed ventilator. All Viking ventilator kits are designed specifically for use with Viking hoods. Use of any non-Viking ventilator kit will void the hood warranty.
READ AND SAVE THESE INSTRUCTIONS
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
2. Sufficient air is needed for proper combustion and exhausting of gases through the flute (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
3. When cutting of drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
4. Ducted fans must always be vented to the outdoors.
5. WARNING!: To reduce risk of fire, use only metal ductwork
6. CAUTION!: To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings, or into attics, crawl spaces, or garages.
7. CAUTION!: To Reduce the Risk of Fire and Electric Shock, Install this rangehood only with remote blower models manufactured by Viking, model numbers – DEV900/DEV1200, VEV900/VEV1200, OR DEV1500, VEV1500 or integral blowers manufactured by Viking, model numbers – DIV300, DIV440, DIV600, DIV800, DIV1200, VIV300, VIV600, or VIV1200. NOTE – Please refer inside for specific canopy/blower combinations.
W A R N I N G
W A R N I N G
To reduce the risk of fire, electric shock, or injury to persons, observe the following:
• Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
• Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
2
Warnings & Important Information
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3-
4
VWH 10”H. Wall Hoods w/Standard Ventilator 24”, 30”, & 36”
Dimensions & Specifications _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 5 Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 6 Interior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 7
VWH 18”H. 24”/27” Deep Wall Hoods 30”, 36”, 42”, 48”, 54”, & 60”
Dimensions & Specifications _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 8 Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 9 Interior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 10 Exterior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 11
VWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”
Dimensions & Specifications _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 12 Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 13
VCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, 54”, 60”, & 66”
Dimensions & Specifications _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 14 Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 15 Interior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 16 Exterior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 17
DCWH Classic Chimney Hoods 30”, 36”, 42”, & 48”
Dimensions & Specifications _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 18 Clearance Dimensions_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 19 Interior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 20 Exterior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 21
VCIH Chimney Island Hoods 36”, 42”, 54”, & 66”
Dimensions & Specifications _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 22 Clearance Dimensions_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 23 Interior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 24 Exterior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 25
VBCV Wall Custom Ventilator System
Dimensions & Specifications _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 26 Installing Hood Canopy _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 27 Clearance Dimensions_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 28
VBCV Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 29 Planning Information_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 31 Installation Procedures
Installation (VWH 10”H. Wall Hoods w/Standard Ventilator) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 32
Duct Cover Option (VWH 10”H. Wall Hoods w/Standard Ventilator)_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 34
Installation (VWH 10”H. Wall Hoods w/Recirculating Kit) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 34
Installation (VWH 18”H. Wall & VCWH Chimney Wall Hoods) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 37
Duct Cover Option (VWH 18”H. Wall Hoods)_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 38
Duct Cover Option (VCWH Chimney Wall Hoods) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 39
Installation (VCIH Island Hoods) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 40
Installation (DCWH Classic Chimney Hoods) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 42 Service & Registration_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 44 Wiring Diagram _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 45
5
IMPORTANT–Please Read and Follow!
4
W A R N I N G
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS
Rangehoods must be installed with the ventilators that are specified on their carton indicating suitability with this model. Other ventilators cannot be substituted.
C A U T I O N
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
W A R N I N G
To reduce the risk of injury to persons in the event of a rangetop grease fire, observe the following. (Based on “Kitchen Firesafety Tips,” published by NFPA.)
1. SMOTHER FLAMES with a close fitted lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN. You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels a violent steam explosion will result.
4. Use an extinguisher ONLY if
• You know it is a Class ABC extinguisher, and you
already know how to operate it.
• The fire is small and contained in the area where
it started.
• The fire department is being called.
• You can fight the fire with your back to an exit.
Dimensions & Specifications
(VWH 10”H. Wall Hoods w/Standard Ventilator 24”, 30”, & 36”)
* Disregard when using recirculating kits. 460 CFM blower is shipped with hood.
NOTE: Optional duct cover sold separately.
VWH 10”H. Wall Hoods w/Standard Ventilator
Description 24” 30” 36”
Duct cover width
23-7/8” (60.6 cm) 29-7/8” (75.9 cm) 35-7/8” (91.1 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm)
Number of lights
2
Number of filters
2
Heat lamps
N/A
Interior ventilator kit
460 CFM Standard
Interior duct size*
7” (17.8 cm)
Interior—Maximum amps
5.6
6
Clearance Dimensions
7
Interior Ventilator Dimensions
460 CFM Interior Ventilator Installation
Top View
(VWH 10”H. Wall Hoods w/Standard Ventilator)
(VWH 10”H. Wall Hoods w/Standard Ventilator)
9
Dimensions & Specifications
8
(VWH 18”H. 24” Deep Wall Hoods 30”, 36”, 42”, 48”, 54”, & 60”) (VWH 18”H. 27” Deep Wall Hoods 36”, 48”, & 60”)
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2­wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
Clearance Dimensions
(VWH 18”H. Wall Hoods)
NOTE: Optional duct cover sold separately.
VWH 18”H. Wall Hoods
Description 30” 36” 42” 48” 54” 60”
Duct cover width
29-7/8”
(75.9 cm)
35-7/8”
(91.1 cm)
41-7/8”
(106.4 cm)
47-7/8”
(121.6 cm)
53-7/8”
(136.8 cm)
59-7/8”
(152.1 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm)
Number of lights
2 2 2 3 3 4
Number of filters
2 2 2 3 3 4
Heat lamps
1 1 1 2 2 2
Interior ventilator kits
VINV300/ 600/1200
VINV300/ 600/1200
VINV600/
1200
VINV1200* VINV1200* VINV1200*
Exterior ventilator kits
DEV900/
1200*
DEV900/
1200*
DEV900/
1200*
DEV1200*/
1500**
DEV1200*/
1500**
DEV1200*/
1500**
In-line ventilator kits
DIL900/1200 DIL900/1200 DIL900/1200 DIL1200 DIL1200 DIL1200
Interior duct size
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
Exterior duct size
10” (25.4 cm)
Interior—Maximum amps
4.9/5.9 4.9/5.9 11.5 11.5 11.5 11.5
Exterior—Maximum amps
8.7/6.0 8.7/6.0 8.7/6.0 8.5/9.2 8.5/9.2 8.9/9.2
In-Line—Maximum amps
6.0/7.9 6.0/7.9 6.0/7.9 10.3 10.3 10.7
Exterior Ventilator Dimensions
11
Interior Ventilator Dimensions
10
900 or 1200 CFM Exterior or In-Line Ventilator Installation for all
Wall Hoods
1200 or 1500 CFM Exterior or In-Line Ventilator Installation for all
Wall Hoods
300 or 600 CFM Interior Ventilator Installation for all Wall Hoods
1200 CFM Interior Ventilator Installation for all Wall Hoods
Top View
Top View
Top View
Top View
(VWH 18”H. Wall Hoods) (VWH 18”H. Wall Hoods)
1312
Dimensions & Specifications
(VWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”)
* A 1,200 CFM interior- or exterior-power ventilator should be used with all T-Series models and when i ndoor models are
installed over range/rangetop with gas char-grill. Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2­wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
NOTE: Optional duct cover sold separately.
Clearance Dimensions
(VWHO 18”H. Outdoor Wall Hoods)
Note: Outdoor Models must be installed in a covered, non-enclosed area, and should be protected from the elements as much as possible.
The bottom of the hood should be 30” (76.2 cm) to 36” (91.4 cm) above the grill surface. The hood should be installed 4-1/2” (11.4 cm) plus the distance between the back trim and surface from the back wall. (Note: There is a 3” minimum clearance from the back trim to non-combustible surfaces, and a 24” minimum to combustible surfaces.) This will require building the hood out from the wall. Any combustible material used for this purpose must be covered with locally-supplied stainless steel. Viking also recommends using a backsplash.
VWHO 18”H. Outdoor Wall Hoods
Description 36” 48” 60”
Duct cover width
35-7/8” (91.1 cm) 47-7/8” (121.6 cm) 59-7/8” (152.1 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm)
Number of lights
2 3 4
Number of filters
2 3 4
Interior ventilator kits
VINV1200* VINV1200* VINV1200*
Exterior ventilator kits
DEV1200*/1500** DEV1200*/1500** DEV1200*/1500**
In-line ventilator kits
DIL1200 DIL1200 DIL1200
Interior duct size
10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
Interior—Maximum amps
9.0 11.4 11.8
Exterior—Maximum amps
6.1/6.8 8.4/9.1 8.8/9.5
In-Line—Maximum amps
7.9 10.2 10.6
15
Dimensions & Specifications
14
(VCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, 54”, 60”, & 66”)
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2­wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
Clearance Dimensions
(VCWH Chimney Wall Hoods)
NOTE: Optional duct cover sold separately.
VCWH Chimney Wall Hoods
Description 30” 36” 42” 48” 54” 60” 66”
Duct cover width
12” (30.5 cm) 12” (30.5 cm) 12” (30.5 cm) 18” (45.7 cm) 18” (45.7 cm) 24” (61.0 cm) 24” (61.0 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm) to 24” (61.0 cm)
Number of lights
2 2 2 3 3 4 4
Number of filters
2 2 2 2 3 3 3
Heat lamps
1 1 1 2 2 2 2
Interior ventilator kits
VINV300/600 VINV300/600 VINV600 VINV1200* VINV1200* VINV1200* VINV1200*
Exterior ventilator kits
DEV900/
1200*
DEV900/
1200*
DEV900/
1200*
DEV1200*/
1500**
DEV1200*/
1500**
DEV1200*/
1500**
DEV1200*/
1500**
In-line ventilator kits
DIL900/1200 DIL900/1200 DIL900/1200 DIL1200 DIL1200 DIL1200 DIL1200
Interior duct size
7” (17.8 cm) 7” (17.8 cm) 7” (17.8 cm) 10” (25.4 cm) 10” (25.4 cm) 10” (25.4 cm) 10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
Interior—Maximum amps
4.9/5.9 4.9/5.9 5.9 11.5 11.5 11.9 11.9
Exterior—Maximum amps
8.7/6.0 8.7/6.0 8.7/6.0 8.5/9.2 8.5/9.2 8.5/9.2 8.5/9.2
In-Line—Maximum amps
6.0/7.9 6.0/7.9 6.0/7.9 10.3 10.3 10.7 10.7