Viking RVCH336SB, RVCH330CS, RVCH330BW, RVCH330BF, RVCH330AG Installation Manual

...
Page 1
3 Series
Hoods
RVCH330 RVCH336
Installation
Page 2
Table of Contents
Warnings & Important Information
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3
RVCH Classic Chimney Wall Hoods w/Standard Ventilator
I n s t a l l a t i o n ( R V C H C l a s s i c C h i m n e y W a l l H o o d s w / S t a n d a r d V e n t i l a t o r ) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 9
D u c t C o v e r ( R V C H C l a s s i c C h i m n e y W a l l H o o d s w / S t a n d a r d V e n t i l a t o r ) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 1
I n s t a l l a t i o n ( R V C H C l a s s i c C h i m n e y W a l l H o o d s w / R e c i r c u l a t i n g K i t ) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 2 S e r v i c e & R e g i s t r a t i o n _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 5
2
Page 3
3
IMPORTANT–Please Read and Follow!
NOTE:
If installing hood with warming shelf panel,
install warming shelf panel first.
IMPORTANT – PLEASE READ AND FOLLOW
• Before beginning, please read these instructions
completely and carefully.
DO NOT remove permanently affixed labels, warnings,
or plates from the product. This may void the warranty.
• Please observe all local and national codes and
ordinances. If no local codes are applicable, wire in accordance with the National Electrical Code, ANSI/NFPA 70-latest edition.
• The installer should leave these instructions with the
consumer who should retain for local inspector’s use and for future reference.
• Check with a qualified and trained installer or local
codes for makeup air requirement, if any.
This hood is for residential installation only and is not designed for installation over a commercial product. Make sure power is off at the main circuit breaker or fuse box before making connections. To avoid risk of fire, electric shock, or injury to persons, turn off the electricity to the hood from the power supply before servicing or cleaning.
Viking hoods are equipped with the variable speed controls for blowers. These units will not function with a single speed ventilator. All Viking ventilator kits are designed specifically for use with Viking hoods. Use of any non-Viking ventilator kit will void the hood warranty.
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF A RANGETOP GREASE FIRE
1. Never leave surface units unattended at high setting. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when cooking flaming foods. (i.e. crepes suzette, cherries jubilee, peppercorn beef flambé).
3. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the size of the surface element.
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING
1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire­rated construction.
2. Sufficient air is needed for proper combustion and exhausting of gases through the flute (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
3. When cutting or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities.
4. Ducted fans must always be vented to the outdoors.
5. WARNING!: To reduce risk of fire, use only metal ductwork.
6. CAUTION!: To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings, or into attics, crawl spaces, or garages.
7. CAUTION!: To Reduce the Risk of Fire and Electric Shock, Install this range hood only with remote blower models manufactured by Viking, model numbers – DEV900/DEV1200, VEV900/VEV1200, OR DEV1500, VEV1500 or integral blowers manufactured by Viking, model numbers – DIV300, DIV440, DIV600, DIV800, DIV1200, VIV300, VIV600, or VIV1200. NOTE – Please refer inside for specific canopy/blower combinations.
WARNING
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING
• Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
• Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Page 4
IMPORTANT–Please Read and Follow!
4
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS
R ange hoods must be installed with the ventilators that are specified on their carton indicating suitability with this model. Other ventilators cannot be substituted.
CAUTION
For general ventilating use only. DO NOT use to exhaust hazardous or explosive materials and vapors.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGETOP GREASE FIRE, OBSERVE THE FOLLOWING. (Based on “Kitchen Firesafety Tips,” published by NFPA.)
1. SMOTHER FLAMES with a close fitted lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN. You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels a violent steam explosion will result.
4. Use an extinguisher ONLY if
• You know it is a Class ABC extinguisher, and
you already know how to operate it.
• The fire is small and contained in the area
where it started.
• The fire department is being called.
• You can fight the fire with your back to an exit.
CAUTION
This appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Page 5
5
RVCH Classic Chimney Wall Hoods w/Standard Ventilator
Description 30” 36”
Duct cover width 16” (40.6 cm) Duct cover depth 12” (30.5 cm) Duct cover height 18” (45.7 cm) to 30” (76.2 cm) Number of lights 2 Number of filters 2 Interior ventilator kit 460 CFM Interior duct size* 7” (17.8 cm) Interior—Maximum amps 5.6
* Disregard when using recirculating kits. 460 CFM blower is shipped with hood.
NOTE: All products must be hard wired with 2-wire with ground.
24”
(61.0 cm)
16”
(40.6 cm)
12”
(30.5 cm)
18”
(30.5 cm)
to
30”
(76.2 cm)
12”
(30.5 cm)
A
A (Hood width)
30”W. 29-7/8” (75.9 cm) 36”W. 35-7/8” (91.1 cm)
2”
(5.1 cm)
Dimensions & Specifications
(RVCH Classic Chimney Wall Hoods w/Standard Ventilator)
NOTE: Duct cover included.
Page 6
6
Clearance Dimensions
(RVCH Classic Chimney Wall Hoods w/Standard Ventilator)
36”
(91.4 cm)
66”min.
(167.6 cm)
to
69”max.
(175.3 cm)
30”min.
(76.2 cm)
to
33”max.
(83.8 cm)
Page 7
7
460 CFM Interior Ventilator Installation
(RVCH Classic Chimney Wall Hoods w/Standard Ventilator)
Top view
Interior Ventilator Dimensions
A
16” (40.6 cm)
30”W. 36”W.
A
14-15/16” (37.9 cm) 17-15/16” (45.6 cm)
4”
(10.2 cm)
9-3/4”
(24.8 cm)
120 V
7” (17.8 cm) dia. duct location
Page 8
8
Planning Information
Plan where the duct work will be located. Install proper-sized duct work, roof, or wall cap for the type of blower you are using. Adjust your measurements for various heights of ceilings, soffits, cabinets, or ranges/rangetops.
Proper installation of ducting is extremely important to ensure maximum performance from any ventilation product.
• All CFMs are based on tests at 0.1 static pressure: without applying static pressure, CFM would be greatly overstated.
• Straight runs and gradual turns are best; for example, each 90º elbow is equivalent to 5-10 feet (1.52-3.05 m) of straight run.
• Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance.
• Proper performance is dependent on proper ducting; make sure that a qualified and trained installer is used.
• Check with a qualified and trained installer or local codes for makeup air requirement, if any.
• Max. amp rating for hoods includes recommended ventilator kit rating; all products must be hard wired direct with 2-wire with ground.
Check Framing
NOTE: Because of the weight of the hood make sure that the
mounting screws are driven into the framing and not just the drywall. It may be necessary to drill additional holes in the canopy for proper alignment. Some hoods require a locally supplied wood strip for mounting. Check installation procedure of your hood on page 10 to determine if a wood strip is required.
Electrical Supply
Run 120 VAC electrical wiring from service panel to installation location. See specification pages for the maximum amp requirements.
k
k
k
p
Roof cap
7” round duct
Roof cap
10” round duct
Exterior blower
10” round duct
300 or 600 CFM
single blower
interior-power
typical ductwor
Duct cover or soffit
Hood
1200 CFM
single blower
interior power
typical ductwor
Duct cover or soffit
Hood
900, 1200, or
1500 CFM
exterior power
typical ductwor
Duct cover or soffit
Hood
Wall installation
exterior power
Wall cap
Duct
NOTE: Wall exhaust must be a minimum of 24” (61.0 cm) from ground. This may vary depending on local codes and geogra
hic location.
typical ductwork
Duct cover or soffit
Hood
Page 9
9
Installation (RVCH Classic Chimney Wall Hoods w/Standard Ventilator)
1
Check damper for unrestricted movement,
adjust if necessary.
Attach transition to damper. Seal with aluminum tape.
Flip hood over and remove electrical box cover.
1
Insert 6” of electrical wiring through the
top of vent hood and secure using wiring restrain.
Refer to local codes.
Slide duct over transition and tape around joint.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING
• Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
• Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
2
3
4
5
2
1
Page 10
10
CAUTION: If not using a duct cover, using
screws provided make sure top mounting screws are
secured into soffit or cabinet frame. Use additional
mounting screws, if necessary.
Connect black to black, white to white, and the green/bare
wire under the green screw.
NOTE: Housing wiring must be properly installed for wiring to
be correct when wiring unit.
5/16” n
ut driver
BLACK
BLACK
WHITE
WHITE
GREEN
BARE OR GREEN
Replace electrical box cover. Make connection to breaker
box.
1
Slide spacer front over front lip. Push spacer rear up, then
slide back over rear lip.
Slide filter front over front lip. Push filter rear up,
then slide back over rear lip.
2
CAUTION: Secure vent hood to wall using screws provided.
Use additional mounting screws and
wall anchors, if necessary.
6
5/16” n
ut driver
7
9
8
1
1
2
10
1
2
3
3
Page 11
11
2
Place duct cover top inside duct cover base and lower until desired
height is found. Mark height. Use the retaining nuts and bolts to fasten
in place from the inside and remove tape.
Slide duct cover in place and fasten from inside
canopy using the sheet metal screws provided.
1
2
Measure distance from ceiling to canopy.
Tape to avoid scratching.
Duct Cover (RVCH Classic Chimney Wall Hoods w/Standard Ventilator)
2
11
Slide filter front over front lip. Push filter rear up,
then slide back over rear lip.
1
3
3
4
Page 12
12
3
Attach with screws and lock washers provided.
Attach with screws.
2
1
Remove damper and discard with transition.
Turn recirculating unit upside down. Place vent hood
upside down on recirculating unit.
Installation (RVCH Classic Chimney Wall Hoods w/Recirculating Kit)
NOTE: If installing a duct cover with a recirculationg kit, the duct cover must be attached to the recirculating kit before installing on the hood.
2
4
Page 13
13
CAUTION: Secure vent hood. Make sure mounting screws
are secured into framing using additional mounting screws
and wall anchors, if necessary.
Connect black to black, white to white, and the green/bare
wire under the green screw.
NOTE: Housing wiring must be properly installed for wiring to
be correct when wiring unit.
5/16” n
ut driver
BLACK
BLACK
WHITE
WHITE
GREEN
BARE OR GREEN
5
Remove electrical box cover.
1
Flip hood over. Insert 6” of electrical wiring through
the top of vent hood and secure using wiring restrain. Refer
to local codes.
Replace electrical box cover. Make connection to breaker
box.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING
• Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
• Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
6
2
8
7
9
1
1
2
Page 14
14
Slide filter front over front lip. Push filter rear up,
then slide back over rear lip.
2
Slide spacer front over front lip. Push spacer rear up, then
slide back over rear lip.
2
10
Slide filter front over front lip. Push filter rear up,
then slide back over rear lip.
1
Assemble brackets to mesh filters and insert
charcoal filters.
11
12
1
3
2
13
1
3
3
Page 15
15
If service is required, call your authorized service agency.
Have the following information readily available.
• Model number
• Serial number
• Date purchased
• Name of dealer from whom purchased
Clearly describe the problem that you are having. If you are unable to obtain the name of an authorized service agency, or if you continue to have service problems, contact Viking Range at 1-888-845-4641, or write to:
VIKING RANGE, LLC
PREFERRED SERVICE
111 Front Street
Greenwood, Mississippi 38930 USA
The model and serial number for your hood is located behind the baffle filter on the left side panel in the lower right corner.
Record the information indicated below. You will need it if service is ever required.
M o de l n o . ____________________________________________________S e ria l no. ________________________________________
D a te of pu r c ha s e ____________________________________________ D ate i ns t a ll e d __________________________________
Dealer’s name __________________________________________________________________________________
Address ________________________________________________________________________________________
______________________________________________________________________________________________
If service requires installation of parts, use only authorized parts to ensure protection under the warranty.
THIS MANUAL SHOULD REMAIN WITH THE HOOD FOR FUTURE REFERENCE.