Viking rc-3 Service Manual

Remote Control of:
• High security building entry systems
• Door strikes and gates in conjunction with doorboxes (W-1000, etc.)
• Signs, lights, cameras, sprinklers, motors
• Other contact controlled equipment
• Can also be used as an emergency dialer for alarm systems, etc.
3 Relay Remote Touch
Tone Controller
August 2, 2001
The RC-3 enables a standard Touch Tone phone to control up to 3 maintained ON, main­tained OFF, or momentary relay contacts from a remote location. The RC-3 is fully user pro­grammable and uses non-volatile E
2
memory.
Up to three RC-3’s can be daisy chained on the same line to control up to nine relays.
The RC-3 features switchable 12V talk battery allowing easy installation on the trunk port. In addition, the unit can be connected directly to a C.O. line or analog PABX/KSU station.
Control 1 to 9 Relays Remotely
PPhhoonnee......771155..338866..8888661
1
hhttttpp::////wwwwww..vviikkiinnggeelleeccttrroonniiccss..ccoom
m
• User Touch Tone programmable
• Non-volatile E
2
memory
• 12 digit alarm activated pulse dialer
• 6 digit security code (to access programming)
• 6 digit access code (disable or enable for additional control security)
• Switchable 12V talk battery
• Relay interrogation tones
• Programmable relay time delays
• Cascade up to three RC-3’s to control up to nine relays
• Programmable ring delay before answering
• Status LED’s for relays 1, 2, 3 and the answer relay
• One power adaptor can power up to three units
Power: 120V AC/12V DC 500mA UL listed adapter provided Shipping Weight: 3.6 kg (8 lbs) Dimensions: 133mm x 89mm x 44mm (5.25” x 3.5” x 1.75”) Environmental: 0°C to 32°C (32°F to 90°F) with 5% to 95%
non-condensing humidity
Pulse Dialing Speed: 10 pps Talk Battery Output: 12V DC minimum (15V nominal) Relay contact ratings: .5A @ 125V AC/1A @ 30V DC On hook time between alarm dialing: 2.5 seconds Connections: (2) RJ11 jacks, 10 position screw terminal strip
PPrraaccttiicce
e
T
T
EELLEECCOOM
M
S
S
OOLLUUTTIIOONNSSFFOORRTTHHE
E
221
1
SST
T
C
C
EENNTTUURRY
Y
TECHNICAL
TECHNICAL
FFeeaattuurrees
s
SSppeecciiffiiccaattiioonns
s
The RC-3 also features a built in pulse dialer activated by a contact closure from an alarm system, temperature sensor, etc. The RC-3 will dial the number up to three times sending alert tones indicating an emergency.
AApppplliiccaattiioonns
s
iinnffoo@@vviikkiinnggeelleeccttrroonniiccss..ccoom
m
IInnssttaallllaattiioon
n
B. Expanding To Control From 4 to 9 Relays
Two or three RC-3’s can be daisy chained to the same line to control 1 to 9 relays. One “master” RC-3 can power up to two “slave” RC-3’s by daisy chaining power from terminals 9 and 10. The master/slave shunt should be removed from each slave unit. This will disable each slave’s ring detection and will also reduce the total REN loading on the line.
Note: Each unit must be programmed separately before connecting to the same line (see Programming), and must be programmed with the same access code. Battery Feed switches on the slave units must be in the “OFF” position.
A. Entering the Programming Mode
a. Connect a Touch Tone phone to the RJ-OUT jack. b. Place the BATTERY FEED switch in the ON position. c. Come off hook. d. Enter
and the security code (factory set to 845464).
e. Two beeps should be heard. You are now in the programming mode.
VIKING
©
MODEL RC-3
POWER 12 VDC
1 2 3 4 5 6 7 8 9 10
3 RELAY REMOTE
TOUCH TONE CONTROLLER
12V TALK
BATTERY FEED
RJ-IN RJ-OUT
OFF ON
VIKING
ELECTRONICS
HUDSON,WI 54016
RELAY 1 RELAY 2 RELAY 3
ALARM
INPUT
12 VDC
- +
Input from separate supply and connect to pins 9 & 10 to power units 2 and 3.
Dry contact closure from alarm system (to initiate dialing)
 N/C COM N/O (factory setting)
 N/O COM
Viking Doorbox
(W-2000A shown)
or
Call
VIKING©
12V TALK BATTERY FEED SWITCH - Must be in
left (OFF) position when connecting to a C.O./Station. Place in right (ON) position when connecting to a trunk input of a phone system.
RJ-OUT - Paralleled with RJ-IN for connecting to other telecom equipment (phone, second RC-3, etc.)
COM
N/O
C.O. Line or
Analog
PABX/KSU
Station
Unused
Trunk
Input of
PABX/KSU
VIKING
©
MODEL RC-3
POWER 12 VDC
1 2 3 4 5 6 7 8 9 10
12V TALK
BATTERY FEED
RJ-IN RJ-OUT
OFF ON
RELAY 1 RELAY 2 RELAY 3
ALARM
INPUT
12 VDC
- +
Optional RS-232 I/O
Special software required, contact Viking for more information, (715) 386-8861.
Answer LED Relay 3 LED Relay 2 LED Relay 1 LED
PPrrooggrraammmmiinng
g
1. To Locally Program the RC-3 (without connecting the unit to a telco line)
a. Place the BATTERY FEED switch in the OFF position. b. Connect the RJ-IN jack to your C.O. line or analog PABX/KSU extension. c. Call into the unit. d. When the unit answers, two beeps should be heard. e. Enter
and the security code (factory set to 845464).
f. Two beeps should be heard. You are now in the programming mode.
Note: Upon entering the programming mode (or after a power outage without battery back-up), all relays will return to their programmed state.
2. To Remotely Program the RC-3
VIKING
©
MODEL RC-3
POWER 12 VDC
1 2 3 4 5 6 7 8 9 10
3 RELAY REMOTE
TOUCH TONE CONTROLLER
12V TALK
BATTERY FEED
RJ-IN RJ-OUT
OFF ON
VIKING
ELECTRONICS
HUDSON,WI 54016
RELAY 1 RELAY 2 RELAY 3
ALARM
INPUT
12 VDC
- +
VIKING
©
MODEL RC-3
POWER 12 VDC
1 2 3 4 5 6 7 8 9 10
3 RELAY REMOTE
TOUCH TONE CONTROLLER
12V TALK
BATTERY FEED
RJ-IN RJ-OUT
OFF ON
VIKING
ELECTRONICS
HUDSON,WI 54016
RELAY 1 RELAY 2 RELAY 3
ALARM
INPUT
12 VDC
- +
VIKING
©
MODEL RC-3
POWER 12 VDC
1 2 3 4 5 6 7 8 9 10
3 RELAY REMOTE
TOUCH TONE CONTROLLER
12V TALK
BATTERY FEED
RJ-IN RJ-OUT
OFF ON
VIKING
ELECTRONICS
HUDSON,WI 54016
RELAY 1 RELAY 2 RELAY 3
ALARM
INPUT
12 VDC
- +
Master/Slave Shunt
In Place
Master/Slave Shunt
Removed
Master/Slave Shunt
Removed
Master RC-3
(programmed relay bank
1 for relays 1, 2 and 3)
Slave RC-3
(programmed relay bank
2 for relays 4, 5 and 6)
Slave RC-3
(programmed relay bank
3 for relays 7, 8 and 9)
A. Single RC-3 Installation
Loading...
+ 2 hidden pages