Viking Professional VCBB536LSS, Professional VCSB542SSBR, Professional VCBB536R, Professional VCSB542BR, Professional VCSB548DSS Installation Manual

...
Page 1
Viking Range Corporation
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information,
call 1-888-VIKING1 (845-4641)
or visit the Viking Web site at
vikingrange.com
(070709J)
Viking Installation Guide
Side-By-Side &
Bottom-Mount Refrigerator/Freezer
U
L
C
U
L
Page 2
IMPORTANT–Please Read and Follow!
3
2
Table of Contents
Your safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others.
All safety messages will be preceded by the safety alert symbol and the word“DANGER” or “WARNING.” These words mean:
D A N G E R
You will be killed or seriously injured if
you don’t follow instructions.
W A R N I N G
You can be killed or seriously injured if
you don’t follow instructions.
All safety messages will identify the
hazard, tell you how to reduce the chance
of injury, and tell you what can happen if
the instructions are not followed.
Warnings & Important Information _____________________________________________________ 3 Professional & Professional Integrated Side-by-Side
Dimensions & Specifications (Professional 42” & 48”) ________________________________ 6 Dimensions & Specifications (Professional Integrated 42” & 48”) _______________________8 Cutout Dimensions (42”) _________________________________________________________10 Anti-Tip Dimensions (42”) ________________________________________________________11 Cutout Dimensions (48”)_________________________________________________________ 12 Anti-Tip Dimensions (48”)________________________________________________________ 13
Professional & Professional Integrated Bottom-Mount
Dimensions & Specifications (36”)_________________________________________________ 14 Cutout Dimensions (36”)_________________________________________________________ 16
Anti-Tip Dimensions (36”)________________________________________________________ 17 Cabinet Infor mation (Professional) ____________________________________________________ 18 Cabinet Infor mation (Professional Integrated) __________________________________________ 20 Designer Side-by-Side
Dimensions & Specifications (42” & 48”)___________________________________________ 22
Cutout Dimensions (42”)_________________________________________________________ 24
Anti-Tip Dimensions (42”)________________________________________________________ 25
Cutout Dimensions (48”)_________________________________________________________ 26
Anti-Tip Dimensions (48”)________________________________________________________ 27 Designer Bottom-Mount
Dimensions & Specifications (36”)_________________________________________________ 28
Cutout Dimensions (36”)_________________________________________________________ 30
Anti-Tip Dimensions (36”)________________________________________________________ 31 Cabinet Infor mation (Designer) _______________________________________________________ 32 Custom Side Panel Dimensions (Professional) __________________________________________ 34 Custom Side Panel Dimensions (Designer & Professional Integrated) _____________________ 35 General Infor mation ________________________________________________________________ 36 Unpacking & Moving _______________________________________________________________ 38 Installation_________________________________________________________________________ 39
Hinge Adjustment ______________________________________________________________ 40
Kickplate Installation ____________________________________________________________ 42
Door Stop Adjustment __________________________________________________________43
Water Filter Installation__________________________________________________________ 44
System Specifications and Data___________________________________________________ 45
Final Installation ________________________________________________________________46 Performance Checklist ______________________________________________________________47 Control Panels _____________________________________________________________________48 Service & Registration_______________________________________________________________49
• Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying voltage, frequency, wattage, amperage, and phase is attached to the product.
• To reduce the risk of fire, electric shock, or injury to persons, installation work and electrical wiring must be done by qualified people in accordance with all applicable codes and standards, including fire-rated construction.
• The installer should leave these instructions with the consumer who should retain them for local inspector’s use and for future reference.
Page 3
IMPORTANT–Please Read and Follow!
5
IMPORTANT–Please Read and Follow!
4
W A R N I N G
ELECTRICAL SHOCK HAZARD
Disconnect power or turn power disconnect switch to OFF position before removing top grille. Failure to do so can result in death or electrical shock.
W A R N I N G
TIP OVER HAZARD
Appliance is top heavy and tips easily when not completely installed. Keep doors closed until appliance is completely installed and secured per installation instructions.
Use two or more people to move and install appliance. Failure to do so can result in death or serious injury.
Most of the unit’s weight is at the top. Extra care is needed when moving the unit to prevent tipping. Use cardboard shipping material or plywood under unit until it is installed in the operating position to protect floor surface.
It is your responsibility to:
• comply with installation specifications and dimensions.
• properly install unit.
• remove any moldings or decorative panels that prevent the unit from being serviced.
• make sure that you have these materials (not provided with your unit), which are necessary for proper installation:
• 1/4” (6 mm) copper tubing with shutoff valve
• 6– #8 x 3” (7.6 cm) wood screws (longer screws may be required)
• 1– Saddle valve (do not use self-piercing feature of the valve)
• assure that floor will support unit, door panels and contents (approximately 1200 pounds [540 kg]).
• provide a properly grounded electrical outlet.
• assure that location will permit appliance doors to open 90° minimum.
A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or local ordinances.
• The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture.
• Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below.
If the use of a GFI is required, it should be:
• Of the receptacle type (breaker type or portable type NOT recommended)
• Used with permanent wiring only (temporary or portable wiring NOT recommended)
• On a dedicated circuit (no other receptacles, switches or loads in the circuit)
• Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT recommended)
• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard)
• In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations)
• Protected from moisture (water, steam, high humidity) as much as reasonably possible
Page 4
Specifications (Professional Side-By-Side)
7
2
4
1
1
/1
6
(
6
2
.
7
cm)
4
1”
(
1
0
4
.
1
cm
)
7
5
1
5
/
1
6
(
1
9
2
.9
cm
)
3
1
9
/3
2”
(
9
.
1
c
m
)
4
2
(
1
0
6
.7
c
m)
9
5/3
2”
(
2
3
.3
c
m
)
8
2–
3/
4
(
2
1
0. 2
cm
)
m
i
n
.
t
o
8
4
1
/
1
6
(
2
1
3. 5
c
m)
ma
x
.
20
3
/
4
(5
2
.
7 c
m)
22
–3/1
6”
(5
6
.
4
c
m)
24–1
1/16
(62
.7
c
m
)
4
7
(
11
9.
4
cm
)
7
5
1
5
/
1
6
(
1
9
2
.
9
cm
)
3
–19
/
32
(
9.1 c
m)
4
8”
(1
2
1
.9
cm
)
9–
5
/3
2
(
2
3
.
3
c
m
)
8
2
3
/4
(2
1
0. 2
cm)
mi
n
.
t
o
84
1
/
1
6
(2
1
3. 5
c
m)
ma
x
.
2
0
3
/
4
(5
2
.7 c
m
)
1–
1
/
2
(
3
.
8
c
m
)
22
–3
/
1
6
(
5
6
.4
c
m
)
27
1
/
4
(69
.2
cm
)
1–
1
/
2
(
3
.
8
c
m
)
27–
1/
4
(69
.2
cm
)
Dimensions (Professional Side-By-Side)
6
42” Professional Side-By-Side
Description VCSB542 VCSB542D
O
verall width 42” (106.7 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 22-3/16” (56.4 cm)
To front of top grille: 24-11/16” (62.7 cm) To front of handle endcap: 27-1/4” (69.2 cm)
Cutout width 41-1/2” (105.4 cm) min. to 41-3/4” (106 cm) max. Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.9 amps Inlet water
1/4” copper tubing inlet waterline; 1/4” copper tubing inletwaterline;
Requirements
minimum 20 psi; maximum 120 psi minimum 35 psi; maximum 120 psi
Overall interior dimensions
Refrigerator 15.0 cu. ft. (425 liters) 15.0 cu. ft. (425 liters) Freezer 9.0 cu. ft. (255 liters) 8.6 cu. ft. (243 liters) Total capacity 24.0 cu. ft. (680 liters) 23.6 cu. ft. (668 liters)
Approximate shipping weight 652 lbs. (293.4 kg) 676 lbs. (304.2 kg)
48” Professional Side-By-Side
Description VCSB548 VCSB548D
Overall width 48” (121.9 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 22-3/16” (56.4 cm)
To front of top grille: 24-11/16” (62.7 cm) To front of handle endcap: 27-1/4” (69.2 cm)
Cutout width 47-1/2” (120.7 cm) min. to 47-3/4” (121.3 cm) max. Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.9 amps Inlet water
1/4” copper tubing inlet waterline; 1/4” copper tubing inlet waterline;
Requirements minimum 20 psi; maximum 120 psi minimum 35 psi; maximum 120 psi
Overall interior dimensions Refrigerator 18.5 cu. ft.(524 liters) 18.5 cu. ft. (524 liters) Freezer 8.9 cu. ft.(252 liters) 8.6 cu. ft. (243 liters) Total capacity 27.4 cu. ft.(776 liters) 27.1 cu. ft. (767 liters)
Approximate shipping weight 715 lbs. (321.8 kg) 735 lbs. (330.8 kg)
42” Professional
48” Professional
Page 5
Specifications (Professional Side-By-Side)
9
2
4
(
6
1
.
0
cm)
4
1”
(
1
0
4
.
1
cm
)
7
5
1
5
/
1
6
(
1
9
2
.9
cm
)
3
1
9
/3
2”
(
9
.
1
c
m
)
4
2
(
1
0
6
.7
c
m)
9
5/3
2”
(
2
3
.
3
c
m
)
8
2–
3/
4
(
2
1
0. 2
cm
)
m
i
n
.
t
o
8
4
1
/
1
6
(
2
1
3. 5
c
m)
ma
x
.
20
3
/
4
(5
2
.7
c
m)
23–
3/8”
(5
9
.
4
c
m)
24”
(61
.0
c
m)
4
7
(
11
9.
4
cm
)
7
5
1
5
/
1
6
(
1
9
2
.
9
cm
)
3
–19
/
32
(
9.1 c
m)
4
8”
(1
2
1
.9
cm
)
9–
5
/3
2
(
2
3
.
3
c
m
)
8
2
3
/4
(2
1
0. 2
cm)
mi
n
.
t
o
84
1
/
1
6
(2
1
3. 5
c
m)
ma
x
.
2
0
3
/
4
(52
.7
c
m
)
1–
1
/
2
(
3
.
8
c
m
)
23–
3/8
(
59
.
4
c
m
)
26
1
/
2
(67
.3
cm
)
1–
1
/
2
(
3
.
8
c
m
)
26–
1/
2
(67
.3
cm
)
Dimensions (Professional Side-By-Side)
8
42” Professional Integrated
48” Professional Integrated
42” Professional Integrated Side-By-Side
Description VISB542 VISB542D
O
verall width 42” (106.7 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8” (59.4 cm)
To front of top grille: 24” (61.0 cm) To front of handle endcap: 26-1/2” (67.3 cm)
Cutout width 42” (106.7 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.9 amps Inlet water
1/4” copper tubing inlet waterline; 1/4” copper tubing inletwaterline;
requirements
minimum 20 psi; maximum 120 psi minimum 35 psi; maximum 120 psi
Overall interior dimensions
Refrigerator 15.0 cu. ft. (425 liters) 15.0 cu. ft. (411 liters) Freezer 9.0 cu. ft. (255 liters) 8.6 cu. ft. (244 liters) Total capacity 24.0 cu. ft. (680 liters) 23.6 cu. ft. (668 liters)
Approximate shipping weight 625 lbs. (293.4 kg) 676 lbs. (304.2 kg)
48” Professional Integrated Side-By-Side
Description VISB548 VISB548D
Overall width 48” (121.9 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8” (59.4 cm)
To front of top grille: 24” (61.0 cm) To front of handle endcap: 26-1/2” (67.3 cm)
Cutout width 48” (121.9 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.9 amps Inlet water
1/4” copper tubing inlet waterline; 1/4” copper tubing inlet waterline;
requirements minimum 20 psi; maximum 120 psi minimum 35 psi; maximum 120 psi
Overall interior dimensions Refrigerator 18.5 cu. ft.(524 liters) 18.5 cu. ft. (507 liters) Freezer 8.9 cu. ft.(252 liters) 8.6 cu. ft. (243 liters) Total capacity 27.4 cu. ft.(776 liters) 27.1 cu. ft. (767 liters)
Approximate shipping weight 715 lbs. (321.8 kg) 735 lbs. (330.8 kg)
Page 6
Two 2”x 4” Mounting Boards
3” (7.6 cm) x 3-1/2” (8.9 cm)
NOTE: If unit is installed deeper than
24” (61.0 cm),then shim behind the mounting
board by the difference.
One 2”x 4” Mounting Board 3” (7.6 cm) x 3-1/2” (8.9 cm)
NOTE: If unit is installed deeper than
24” (61.0 cm), then shim behind the mounting
board by the difference.
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
NOTE: Top of unit must be placed firmly under anti-tip board.
Professional Anti-Tip Location
Professional Integrated Anti-Tip Location
7
9–
3/8”
(20
1
.6
c
m)
mi
n.
t
o
b
o
t
t
o
m
o
f
a
nt
i
-
t
i
p
b
o
a
rd
8
0–
1/2”
(20
4.6 c
m)
ma
x.
t
o
b
o
t
t
o
m
o
f
a
nt
i
-
t
i
p
b
o
a
rd
3
5
(
8
8
.
9
c
m
)
3–
1
/2”
(8
.
9
cm
)
3
(
7.
6 c
m
)
3
5”
(
88
.9
cm
)
3–1
/2
(8.
9 c
m)
1.5”
(3
.8
cm
)
Anti-Tip Dimensions (Professional Side-By-Side)
11
9
(
2
2
.
9
c
m)
7
3
-
3
/
8
(1
8
6
.
4
c
m
)
82
7
/
8
(
2
1
0
.
5
c
m
)
m
i
n
.
a
n
t
i
-
t
i
p
b
o
a
r
d
&
o
p
e
n
i
n
g
h
e
i
g
h
t
8
4
1
/
1
6
(
2
1
3
.
5
c
m
)
m
a
x
.
a
n
t
i
-
t
i
p
b
o
a
r
d
&
o
p
e
n
i
n
g
h
e
i
g
h
t
4
1
–1
/
2
(
1
0
5
.
4
c
m
)
m
i
n
.
t
o
4
1
3
/
4
(
1
0
6
.
0
c
m
)
m
a
x
.
4
2
(
1
0
6
.
7
c
m
)
P
r
o
f
e
s
s
i
o
n
a
l
I
n
t
e
g
r
a
t
e
d
m
o
d
e
l
s
o
n
l
y
2
4
(
6
1
.
0
c
m
)
Electric Outlet Location
Water Line Entry Area
6
3
/
4
(
1
7
.
1
c
m
)
7
5
/
8
(
1
9
.
4
c
m
)
3
(
7
.
6
c
m
)
5
/
8
(
1
.
6
c
m
)
5
/
8
(
1
.
6
c
m
)
1
0
1
/
2
(
2
6
.
7
c
m
)
5
/
8
(
1
.
6
c
m
)
10
3/
4
(
2
7
.
3
c
m
)
1
(
2
.
5
c
m
)
3
5
/
8
(
9
.
2
c
m
)
O
p
t
i
on
a
l
f
l
o
o
r
w
a
t
e
r
l
i
n
e
e
n
t
r
y
4
2
(
1
0
6
.
7
c
m
)
P
r
o
f
e
s
s
i
o
n
a
l
I
n
t
e
g
r
a
t
e
d
m
o
d
e
l
s
o
n
l
y
4
1
1
/
2
(
1
0
5
.
4
c
m
)
S
e
e
A
n
t
i
-
T
i
p
b
o
a
r
d
i
n
s
t
a
l
l
a
t
i
o
n
6
(
1
5
.
2
c
m
)
9
(
2
2
.
9
c
m
)
Cutout Dimensions (Professional Side-By-Side)
10
42” Professional & Professional Integrated
42” Professional
Page 7
Two 2”x 4” Mounting Boards
3” (7.6 cm) x 3-1/2” (8.9 cm)
NOTE: If unit is installed deeper than
24” (61.0 cm), then shim behind the mounting
board by the difference.
NOTE: If unit is installed deeper than
24” (61.0 cm), then shim behind the mounting
board by the difference.
One 2”x 4” Mounting Board 3” (7.6 cm) x 3-1/2” (8.9 cm)
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
NOTE: Top of unit must be placed firmly under anti-tip board.
Professional Anti-Tip Location
Professional Integrated Anti-Tip Location
7
9–
3/8”
(20
1
.6
c
m)
mi
n
.
t
o b
ot
t
o
m
of
a
nt
i
-
t
i
p
bo
a
rd
8
0–
1/2”
(20
4.6 c
m)
ma
x.
t
o b
ot
t
o
m
of
a
nt
i
-
t
i
p
bo
a
rd
41”
(
1
0
4
.
1
c
m
)
3–1
/2”
(8
.
9
c
m
)
3
(
7
.
6
c
m
)
4
1”
(
10
4.1
cm
)
3–1
/2”
(
8.
9
cm
)
1-1/
2
(3
.8
cm
)
Anti-Tip Dimensions (Professional Side-By-Side)
13
9
(
22
.
9 c
m
)
7
3
-
3
/
8
(18
6.
4
c
m
)
82
7
/
8
(
2
1
0
.
5
c
m
)
m
i
n
.
a
n
t
i
-
t
i
p
b
o
a
r
d
&
o
p
e
n
i
n
g
h
e
i
g
h
t
8
4
1
/
1
6
(
2
1
3
.
5
c
m
)
m
a
x
.
a
n
t
i
-
t
i
p
b
o
a
r
d
&
o
p
e
n
i
n
g
h
e
i
g
h
t
4
7
1
/
2
(
1
2
0
.
7
c
m
)
m
i
n
.
t
o
4
7
3
/
4
(
1
2
1
.
2
c
m
)
m
a
x
.
4
8
(
1
2
1
.
9
c
m
)
P
r
o
f
e
s
s
i
o
n
a
l
I
n
t
e
g
r
a
t
e
d
m
o
d
e
l
s
o
n
l
y
2
4
(
6
1
.
0
c
m
)
Electric Outlet Location
Water Line Entry Area
6
3
/
4
(
1
7
.
1
c
m
)
7
5
/
8
(
1
9
.
4
c
m
)
3
(
7
.
6
c
m
)
5
/
8
(
1
.
6
c
m
)
5
/
8
(
1
.
6
c
m
)
1
0
1
/
2
(
2
6
.
7
c
m
)
5
/
8
(
1
.
6
c
m
)
1
0
3
/
4
(
2
7
.
3
c
m
)
1
(
2
.
5
c
m
)
3
5
/
8
(
9
.
2
c
m
)
O
p
t
i
on
a
l
f
l
o
o
r
w
a
t
e
r
l
i
n
e
e
n
t
r
y
4
7
1
/
2
(
1
2
0
.
7
c
m
)
4
8
(
1
2
1
.
9
c
m
)
P
r
o
f
e
s
s
i
o
n
a
l
I
n
t
e
g
r
a
t
e
d
m
o
d
e
l
s
o
n
l
y
S
e
e
A
n
t
i
-
T
i
p
b
o
a
r
d
i
n
s
t
a
l
l
a
t
i
o
n
6
(
1
5
.
2
c
m
)
9
(
2
2
.
9
c
m
)
Cutout Dimensions (Professional Side-By-Side)
12
48” Professional & Professional Integrated
48” Professional & Professional Integrated
Page 8
Specifications (Professional Bottom-Mount)
15
2
4
1
1
/
1
6
(
6
2
.
7
c
m
)
3
5
(
8
8
.
9
c
m
)
5
2
(
1
3
2
.
1
c
m
)
2
3
–1
/
1
6
(
5
8
.
5
c
m
)
3
1
9
/
3
2
(
9
.
1
c
m
)
3
6
(9
1.
5
c
m
)
9
5
/
32
(
2
3
.
3
c
m
)
8
2
3
/
4
(
2
1
0
.
2
c
m
)
m
i
n
.
t
o
8
4
1
/
1
6
(
2
1
3
.
5
c
m
)
m
a
x
.
2
0
3
/
4
(
5
2
.
7
c
m
)
2
2
3
/
1
6
(
5
6
.
4
c
m
)
1
1
/
2
(
3
.
8
c
m
)
2
7
1
/
4
(
6
9
.
2
c
m
)
2
4
(
6
1
.
0
c
m
)
3
5
(
88
.
9
c
m
)
5
2
(
1
3
2
.
1
c
m
)
2
3
–1
/
1
6
(
5
8
.
5
c
m
)
3
1
9
/
3
2
(
9
.
1
c
m
)
3
6
(9
1
.
5
c
m
)
9
5/
32
(
2
3
.
3
c
m
)
8
2
3
/
4
(
2
1
0
.
2
c
m
)
m
i
n
.
t
o
8
4
1
/
1
6
(
2
1
3
.
5
c
m
)
m
a
x
.
2
0
3
/
4
(
5
2
.
7
c
m
)
2
3
3
/
8
(
5
9
.
4
cm
)
1
1
/
2
(
3
.
8
c
m
)
2
6
1
/
2
(
6
7
.
3
c
m
)
Dimensions (Professional Bottom-Mount)
14
36” Professional
36” Professional Integrated
36” Professional Bottom-Mount
Description VCBB536
Overall width 36” (91.5 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 22-3/16” (56.4 cm)
To front of top grille: 24-11/16” (62.7 cm) To front of handle endcap: 27-1/4” (69.2 cm)
Cutout wdth 35-1/2” (90.2 cm) min. to 35-3/4” (90.8 cm) max. Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.9 amps Inlet water 1/4” copper tubing inlet waterline; minimum 20 psi;
requirements maximum 120 psi
Overall interior dimensions
Refrigerator 15.2 cu. ft. (431 Liters) Freezer 5.1 cu. ft. (145 Liters) Total capacity 20.3 cu. ft. (576 Liters)
Approximate shipping weight 565 lbs. (254.3 kg)
36” Professional Integrated Bottom-Mount
Description VIBB536
Overall width 36” (91.5 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8” (59.4 cm)
To front of top grille: 24” (61.0 cm) To front of handle endcap: 26-1/2” (67.3 cm)
Cutout wdth 36” (91.4 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.9 amps Inlet water 1/4” copper tubing inlet waterline; minimum 20 psi;
requirements maximum 120 psi
Overall interior dimensions
Refrigerator 15.2 cu. ft. (431 Liters) Freezer 5.1 cu. ft. (145 Liters) Total capacity 20.3 cu. ft. (576 Liters)
Approximate shipping weight 565 lbs. (254.3 kg)
Page 9
Two 2”x 4” Mounting Boards
3
” (7.6 cm) x 3-1/2” (8.9 cm)
NOTE: If unit is installed deeper than
24” (61.0 cm), then shim behind the mounting
boards by the difference.
NOTE: If unit is installed deeper than
24” (61.0 cm), then shim behind the mounting
boards by the difference.
One 2”x 4” Mounting Board 3” (7.6 cm) x 3-1/2” (8.9 cm)
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
NOTE: Top of unit must be placed firmly under anti-tip board.
Professional Anti-Tip Location
Professional Integrated Anti-Tip Location
7
9–
3/8”
(20
1
.6
c
m)
mi
n.
t
o b
ot
t
o
m
of
a
nt
i
-
t
i
p
b
o
a
rd
8
0–
1/2”
(20
4.6 c
m)
ma
x.
t
o b
ot
t
o
m
of
a
nt
i
-
t
i
p
bo
a
rd
29–
1/
2
(
7
4
.
9
c
m
)
3–1
/
2”
(
8
.
9
cm
)
3
(
7
.
6
c
m
)
29–
1/2
(74
.9
c
m
)
3–1
/2
(8.
9
c
m)
1.5”
(3
.8
cm
)
Anti-Tip Dimensions (Professional Bottom-Mount)
17
9
(
22
.
9 c
m
)
7
3
-
3
/
8
(18
6.
4
c
m
)
82
7
/
8
(
2
1
0
.
5
c
m
)
m
i
n
.
a
n
t
i
-
t
i
p
b
o
a
r
d
&
o
p
e
n
i
n
g
h
e
i
g
h
t
8
4
1
/
1
6
(
2
1
3
.
5
c
m
)
m
a
x
.
a
n
t
i
-
t
i
p
b
o
a
r
d
&
o
p
e
n
i
n
g
h
e
i
g
h
t
3
5
1
/
2
(
9
0
.
2
c
m
)
m
i
n
.
t
o
3
5
3
/
4
(
9
0
.
8
c
m
)
m
a
x
.
3
6
(
9
1
.
5
c
m
)
P
r
o
f
e
s
s
i
o
n
a
l
I
n
t
e
g
r
a
t
e
d
m
o
d
e
l
o
n
l
y
2
4
(
6
1
.
0
c
m
)
Electric Outlet Location
Water Line Entry Area
6
3
/
4
(
1
7
.
1
c
m
)
7
5
/
8
(
1
9
.
4
c
m
)
3
(
7
.
6
c
m
)
5
/
8
(
1
.
6
c
m
)
5
/
8
(
1
.
6
c
m
)
1
0
1
/
2
(
2
6
.
7
c
m
)
5
/
8
(
1
.
6
c
m
)
1
0
3
/
4
(
2
7
.
3
c
m
)
1
(
2
.
5
c
m
)
3
5
/
8
(
9
.
2
c
m
)
O
p
t
i
on
a
l
f
l
o
o
r
w
a
t
e
r
l
i
n
e
e
n
t
r
y
3
5
1
/
2
(
9
0
.
2
c
m
)
3
6
(
9
1
.
5
c
m
)
P
r
o
f
e
s
s
i
o
n
a
l
I
n
t
e
g
r
a
t
e
d
m
o
d
e
l
o
n
l
y
S
e
e
A
n
t
i
-
T
i
p
b
o
a
r
d
i
n
s
t
a
l
l
a
t
i
o
n
6
(
1
5
.
2
c
m
)
9
(
2
2
.
9
c
m
)
Cutout Dimensions (Professional Bottom-Mount)
16
36” Professional & Professional Integrated
36” Professional & Professional Integrated
Page 10
Top View
1–13/16”
(4.6 cm)
Space if 24”
standard
cabinet
depth is
used
Door
24”
(61.0 cm)
Standard
Cabinet
Depth
Wall
3/4”
(1.9 cm) Full End
Panel
2–1/2”
(6.4 cm) Offset
Countertop
Overhang
Cabinet Information (Professional)
19
To p View
To p View
Door
Wall
1–13/16”
(4.6 cm)
Space if 24”
standard
cabinet
depth is
used
3/4”
(1.9 cm) Full End
Panel
24”
(61.0 cm) Standard
Cabinet
Depth
2–1/2”
(6.4 cm) Offset
5/16”
(0.8 cm)
1–13/16”
(4.6 cm)
Space if 24”
standard
cabinet depth is
used
Door
24”
(61.0 cm)
Standard
Cabinet
Depth
Wall
3/4”
(1.9 cm) Full End
Panel
2–1/2”
(6.4 cm) Offset
Partial Overlay
Cabinet Door
Cabinet Information (Professional)
18
Professional models fit “semi-flush” in standard 24” (61.0 cm) deep cabinet openings. The door face protrudes 2-1/2” (6.4 cm) from the cabinet face. The handle protrudes an additional 2
-1/2” (6.4 cm) into the room.
Professional models fit “semi-flush” in standard 24” (61.0 cm) deep cabinet openings. The door face protrudes 2-1/2” (6.4 cm) from the cabinet face. The handles protrude an additional 2-1/2” (6.4 cm) into the room.
Page 11
Top View
Top View
Door
24”
(61.0 cm)
Standard
Cabinet
Depth
25”
(63.5 cm)
Countertop
Depth
Wall
3/4”
(1.9 cm)
Full End
Panel
Door
Wall
1”
(2.5 cm)
space if
25” (63.5 cm) cabinet depth
is used
3/4”
(1.9 cm) Full End
Panel
25”
(63.5 cm)
Flush
1”
(2.5 cm) space if
25” (63.5 cm)
cabinet depth
is used
Flush
Cabinet Information (Professional Integrated)
21
Top View
Overlapping cabinet doors
Top View
Flush mount cabinet doors
Door
2
4
(
6
1
.
0
c
m
)
S
t
a
n
d
a
r
d
C
a
b
i
n
e
t
D
e
p
t
h
24-3/4”
(62.9 cm)
Wall
3/4”
(1.9 cm)
Full End
Panel
3/4”
(1.9 cm) space if
24” (61.0 cm)
standard
cabinet depth
is used
Flush
Cabinet
Door
Door
Wall
3/4”
(1.9 cm)
Full End
Panel
1”
(2.5 cm) space if
25” (63.5 cm)
cabinet depth
is used
Flush
25”
(63.5 cm) Cabinet
Depth
Cabinet
Door
Cabinet Information (Professional Integrated)
20
Professional Integrated models fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except the handle protrudes 2-1/2” (6.4 cm) into the room.
Professional Integrated models fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except the handle protrudes 2-1/2” (6.4 cm) into the room.
Page 12
Specifications (Designer Side-By-Side)
23
2
4
(
6
1
.
0
c
m
)
4
1
(
1
0
4
.
1
c
m
)
7
5
1
5
/
1
6
(
1
9
2
.
9
c
m
)
3
1
/
2
(
8
.
9
c
m
)
9
5
/
3
2
(
2
3
.
3
c
m
)
8
2
3
/
4
(
2
1
0
.
2
c
m
)
m
i
n
.
to
8
4
1
/
1
6
(
2
1
3
.
5
c
m
)
m
a
x
.
2
0
3
/
4
(
5
2
.
7 c
m
)
1
1
/
2
(
3
.
8
c
m
)
2
3
3
/
8
(
5
9
.
4
c
m
)
2
4
(
6
1
.
0
c
m
)
4
7
(
1
1
9
.
4
c
m
)
7
5
1
5
/1
6
(
1
9
2
.
9
c
m
)
3
1
/
2
(
8
.
9
c
m
)
9
–5
/
3
2
(
2
3
.
3
c
m
)
8
2
3
/
4
(
2
1
0
.
2
c
m
)
m
i
n
.
to
8
4
1
/
1
6
(
2
1
3
.
5
c
m
)
m
a
x
.
2
0
3
/
4
(
5
2
.
7
c
m
)
1
1
/
2
(
3
.
8
c
m
)
2
3
3
/
8
(
5
9
.
4
c
m
)
2
6
-
1
/
2
(
6
7
.
3
c
m
)
2
6
-
1
/
2
(
6
7
.
3
c
m
)
4
2
(
1
0
6
.
7
c
m
)
4
8
(
1
2
1
.
9
c
m
)
Dimensions (Designer Side-By-Side)
22
Designer 42”
Designer 48”
42” Designer Side-By-Side
Description DDSB542 DDSB542D
O
verall width 42” (106.7 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8” (59.4 cm)
To front of top gr:ille: 24” (61.0 cm) To front of handle: 26-1/2” (67.3 cm)
Cutout width 42” (106.7 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.9 amps Inlet water
1/4” copper tubing inlet waterline; 1/4” copper tubing inlet waterline;
Requirements
minimum 20 psi; maximum 120 psi minimum 35 psi; maximum 120 psi
Overall interior dimensions
Refrigerator 15.0 cu. ft. (425 liters) 15.0 cu. ft. (425 liters) Freezer 9.0 cu. ft. (255 liters) 8.6 cu. ft. (243 liters) Total capacity 24.0 cu. ft. (680 liters) 23.6 cu. ft. (668 liters)
Approximate shipping weight 642 lbs. (289kg) 665 lbs. (299.3 kg)
48” Designer Side-By-Side
Description DDSB548 DDSB548D
Overall width 48” (121.9 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8” (59.4 cm)
To front of top grille: 24” (61.0 cm) To front of handle: 26-1/2” (67.3 cm)
Cutout width 48” (121.9 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.9 amps Inlet water
1/4” copper tubing inlet waterline; 1/4” copper tubing inlet waterline;
Requirements
minimum 20 psi; maximum 120 psi minimum 35 psi; maximum 120 psi
Overall interior dimensions
Refrigerator 18.5 cu. ft. (524 liters) 18.5 cu. ft. (524 liters) Freezer 8.9 cu. ft. (252 liters) 8.6 cu. ft. (243 liters) Total capacity 27.4 cu. ft. (776 liters) 27.1 cu. ft. (767 liters)
Approximate shipping weight 705 lbs. (317.3 kg) 730 lbs. (328.5 kg)
Page 13
One 2”x 4” Mounting Board
1–1/2” (3.8 cm) x 3–1/2” (8.9 cm)
NOTE: If unit is installed deeper than 24” (61.0 cm), then shim
behind the mounting board by the difference.
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
NOTE: Top of unit must be placed firmly under anti-tip board.
Anti-Tip Location
7
9–
3/8”
(2
0
1
.6
c
m)
mi
n
.
t
o b
ot
t
o
m
of
a
nt
i
-
t
i
p
bo
a
rd
8
0–
1/2”
(20
4.6 c
m)
ma
x.
t
o b
ot
t
o
m
of
a
nt
i
-
t
i
p
bo
a
rd
35”
(
8
8
.9 cm
)
3
1
/
2
(8.
9 c
m
)
1
1
/2
(3.
8 c
m)
Anti-Tip Dimensions (Designer Side-By-Side)
25
9
(
22
.
9 c
m
)
7
3
3
/
8
(18
6.
4
c
m
)
82
7
/
8
(
2
1
0
.
5
c
m
)
m
i
n
.
a
n
t
i
-
t
i
p
b
o
a
r
d
&
o
p
e
n
i
n
g
h
e
i
g
h
t
8
4
1
/
1
6
(
2
1
3
.
5
c
m
)
m
a
x
.
a
n
t
i
-
t
i
p
b
o
a
r
d
&
o
p
e
n
i
n
g
h
e
i
g
h
t
4
2
(
1
0
6
.
7
c
m
)
2
4
(
6
1
.
0
c
m
)
Electric Outlet Location
Water Line Entry Area
4
2
(
1
0
6
.
7
c
m
)
6
3
/
4
(
1
7
.
1
c
m
)
7
5
/
8
(
1
9
.
4
c
m
)
3
(
7
.
6
c
m
)
5
/
8
(
1
.
6
c
m
)
5
/
8
(
1
.
6
c
m
)
1
0
1
/
2
(
2
6
.
7
c
m
)
5
/
8
(
1
.
6
c
m
)
1
0
3
/
4
(
2
7
.
3
c
m
)
1
(
2
.
5
c
m
)
3
5
/
8
(
9
.
2
c
m
)
O
p
t
i
on
a
l
f
l
o
o
r
w
a
t
e
r
l
i
n
e
e
n
t
r
y
S
e
e
A
n
t
i
-
T
i
p
b
o
a
r
d
i
n
s
t
a
l
l
a
t
i
o
n
6
(
1
5
.
2
c
m
)
9
(
2
2
.
9
c
m
)
Cutout Dimensions (Designer Side-By-Side)
24
42” Designer
42” Designer
Page 14
One 2”x 4” Mounting Board
1–1/2” (3.8 cm) x 3 1/2” (8.9 cm)
NOTE: If unit is installed deeper than 24” (61.0 cm), then shim
behind the mounting board by the difference.
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
NOTE: Top of unit must be placed firmly under anti-tip board.
Anti-Tip Location
7
9–
3/8”
(2
0
1
.6
c
m)
mi
n.
t
o b
ot
t
o
m
of
a
nt
i
-
t
i
p
bo
a
rd
8
0–
1/2”
(20
4.6 c
m)
ma
x.
t
o b
ot
t
o
m
of
a
nt
i
-
t
i
p
bo
a
rd
41”
(10
4
.
1
cm
)
3
1
/
2
(8.
9 c
m
)
1
1
/2
(3.
8 c
m)
Anti-Tip Dimensions (Designer Side-By-Side)
27
9
(
22
.
9 c
m
)
7
3
3
/
8
(18
6.
4
c
m
)
82
7
/
8
(
2
1
0
.
5
c
m
)
m
i
n
.
a
n
t
i
-
t
i
p
b
o
a
r
d
&
o
p
e
n
i
n
g
h
e
i
g
h
t
8
4
1
/
1
6
(
2
1
3
.
5
c
m
)
m
a
x
.
a
n
t
i
-
t
i
p
b
o
a
r
d
&
o
p
e
n
i
n
g
h
e
i
g
h
t
4
8
(
1
2
1
.
9
c
m
)
2
4
(
6
1
.
0
c
m
)
Electric Outlet Location
Water Line Entry Area
4
7
1
/
2
(
1
2
0
.
7
c
m
)
6
3
/
4
(
1
7
.
1
c
m
)
7
5
/
8
(
1
9
.
4
c
m
)
3
(
7
.
6
c
m
)
5
/
8
(
1
.
6
c
m
)
5
/
8
(
1
.
6
c
m
)
1
0
1
/
2
(
2
6
.
7
c
m
)
5
/
8
(
1
.
6
c
m
)
1
0
3
/
4
(
2
7
.
3
c
m
)
1
(
2
.
5
c
m
)
3
5
/
8
(
9
.
2
c
m
)
O
p
t
i
on
a
l
f
l
o
o
r
w
a
t
e
r
l
i
n
e
e
n
t
r
y
S
e
e
A
n
t
i
-
T
i
p
b
o
a
r
d
i
n
s
t
a
l
l
a
t
i
o
n
6
(
1
5
.
2
c
m
)
9
(
2
2
.
9
c
m
)
Cutout Dimensions (Designer Side-By-Side)
26
48” Designer
48” Designer
Page 15
Specifications (Designer Bottom-Mount)
29
2
4
(
6
1
.
0
c
m
)
3
5
(8
8
.
9
c
m
)
5
2
(
1
3
2
.
1
c
m
)
2
3
1
/
1
6
(
5
8
.
5
c
m
)
3
1
/
2
(
8
.
9
c
m
)
9
5
/
3
2
(
2
3
.
3
c
m
)
8
2–
7/
8”
(
2
1
0
.
5
c
m
)
m
i
n
.
t
o
8
4
1
/
1
6
(
2
1
3
.
5
c
m
)
m
a
x
.
2
0
3
/
4
(
5
2
.
7
c
m
)
2
3
3
/
8
(
5
9
.
4
c
m
)
1
1
/
2
(
3
.
8
c
m
)
2
6
-
1
/
2
(
6
7
.
3
c
m
)
3
6
(9
1
.
5
c
m
)
Dimensions (Designer Bottom-Mount)
28
Designer 36”
36” Designer Bottom-Mount
Description DDBB536
O
verall width 36” (91.5 cm)
Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8” (59.4 cm)
To front of top grille: 24” (61.0 cm) To front of handle: 26-1/2” (67.3 cm)
Cutout width 36” (91.5 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.9 amps Inlet water 1/4” copper tubing inlet waterline; minimum 20 psi;
Requirements maximum 120 psi
Overall interior dimensions
Refrigerator 15.2 cu. ft. (431 Liters) Freezer 5.1 cu. ft. (145 Liters) Total capacity 20.3 cu. ft. (576 Liters)
Approximate shipping weight 565 lbs. (254.3 kg)
Page 16
One 2”x 4” Mounting Board
1–1/2” (3.8 cm) x 3–1/2” (8.9 cm)
NOTE: If unit is installed deeper than 24” (61.0 cm), then shim
behind the mounting board by the difference.
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
NOTE: Top of unit must be placed firmly under anti-tip board.
Anti-Tip Location
7
9–
3/8”
(20
1
.6
c
m)
mi
n
.
t
o b
ot
t
o
m
of
a
nt
i
-
t
i
p
bo
a
rd
8
0–
1/2”
(20
4.6 c
m)
ma
x.
t
o b
ot
t
o
m
of
a
nt
i
-
t
i
p
bo
a
rd
29”
(
7
3
.7 cm
)
3
1
/
2
(8.
9 c
m
)
1
1
/2
(3.
8 c
m)
Anti-Tip Dimensions (Designer Bottom-Mount)
31
9
(
22
.
9 c
m
)
7
3
3
/
8
(18
6.
4
c
m
)
82
7
/
8
(
2
1
0
.
5
c
m
)
m
i
n
.
a
n
t
i
-
t
i
p
b
o
a
r
d
&
o
p
e
n
i
n
g
h
e
i
g
h
t
8
4
1
/
1
6
(
2
1
3
.
5
c
m
)
m
a
x
.
a
n
t
i
-
t
i
p
b
o
a
r
d
&
o
p
e
n
i
n
g
h
e
i
g
h
t
3
6
(
9
1
.
5
c
m
)
2
4
(
6
1
.
0
c
m
)
Electric Outlet Location
Water Line Entry Area
3
6
(
9
1
.
5
c
m
)
6
3
/
4
(
1
7
.
1
c
m
)
7
5
/
8
(
1
9
.
4
c
m
)
3
(
7
.
6
c
m
)
5
/
8
(
1
.
6
c
m
)
5
/
8
(
1
.
6
c
m
)
1
0
1
/
2
(
2
6
.
7
c
m
)
5
/
8
(
1
.
6
c
m
)
1
0
3
/
4
(
2
7
.
3
c
m
)
1
(
2
.
5
c
m
)
3
5
/
8
(
9
.
2
c
m
)
O
p
t
i
on
a
l
f
l
o
o
r
w
a
t
e
r
l
i
n
e
e
n
t
r
y
S
e
e
A
n
t
i
-
T
i
p
b
o
a
r
d
i
n
s
t
a
l
l
a
t
i
o
n
6
(
1
5
.
2
c
m
)
Cutout Dimensions (Designer Bottom-Mount)
30
36” Designer
36” Designer
Page 17
Top View
Top View
Door
24”
(61.0 cm)
Standard
Cabinet
Depth
25”
(63.5 cm)
Countertop
Depth
Wall
3/4”
(1.9 cm)
Full End
Panel
Door
Wall
1”
(2.5 cm)
space if 25” (63.5 cm) cabinet depth
is used
3/4”
(1.9 cm) Full End
Panel
25”
(63.5 cm)
Flush
1”
(2.5 cm)
space if
25” (63.5 cm)
cabinet depth
is used
Flush
Cabinet Information (Designer)
33
Top View
O
verlapping cabinet doors
Top View
Flush mount cabinet doors
Door
2
4
(
6
1
.
0
c
m
)
S
t
a
n
d
a
r
d
C
a
b
i
n
e
t
D
e
p
t
h
24-3/4”
(62.9 cm)
Wall
3/4”
(1.9 cm)
Full End
Panel
3/4”
(1.9 cm) space if
24” (61.0 cm)
standard
cabinet depth
is used
Flush
Cabinet
Door
Door
Wall
3/4”
(1.9 cm)
Full End
Panel
1”
(2.5 cm) space if
25” (63.5 cm)
cabinet depth
is used
Flush
25”
(63.5 cm) Cabinet
Depth
Cabinet
Door
Cabinet Information (Designer)
32
Designer models fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except 2-1/2” (6.3 cm) handle depth.
Designer models fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except 2-1/2” (6.3 cm) handle depth.
Page 18
3/4”
(
1.9 cm)
End panel
1”
(2.5 cm)
1/4”
(
0.6 cm)
Z-Bracket
2
1
-3
/
4
(
5
5
.
2
c
m
)
21
-3/
4
(
5
5
.
2
cm
)
24
(
6
1
.
0 cm
)
Optional kickplate
Notch, dimensions determined by cabinets
24”
(
6
1
.
0 cm
)
82
-7 /
8
(
2
1
0. 5
c
m
)
m
in.
t
o
84
-1 /
1
6
(2
1
3. 5
c
m
)
m
a
x
.
*
82
-7 /
8
(
2
1
0
.
5
c
m
)
m
i
n
.
t
o
84
-1 /
1
6
(
2
1
3
.
5
c
m
)
m
a
x
.
*
Custom Side Panel Dimensions
(Designer & Professional Integrated)
35
3
/4”
(1.9 cm)
End panel
5/32”
(0.4 cm)
3
/16”
(0.5 cm)
Back filler
panel
2
2
-
7
/
1
6
(5
7
.
0
c
m
)
22
-
7/1
6”
(
5
7
.
0
cm
)
22
-1/4”
(61
.
0
c
m
)
6”
(1
5
.
2
cm
)
Optional kickplate
Notch, dimensions determined by cabinets
8
2
-7 /8
(2
1
0
.5
cm)
min
.
t
o
8
4
-1 /1
6
(2
1
3
.
5
cm)
max
.
*
82-7
/
8”
(2
1
0. 5
c
m
)
mi
n.
t
o
84-1
/
16
(2
1
3. 5
c
m
)
max.
*
6
(
1
5
.
2 c
m
)
22
-1
/4”
(6
1
.
0
cm
)
Custom Side Panel Dimensions
(Professional)
34
* Depending on how high leveling feet are raised, and cabinet enclosure height.
* Depending on how high leveling feet are raised, and cabinet enclosure height.
Page 19
General Information
Water Supply Requirements
Use only 1/4” (6 mm) copper tubing for water line. Do Not install copper tubing in area where temperatures drop below 35˚ F (1.7˚ C). Before attaching copper tubing to the unit, flush at least 2 quarts (1.9 L) of water through the copper tubing and into a bucket to remove any particles in the water line.
• Viking Range Corporation is not responsible for property damage due to improper installation or water connection.
• Connect 1/4” (6 mm) flexible copper tubing to household plumbing in compliance with local codes and ordinances.
• Length of copper tubing must reach from water supply connection to the unit connection with an additional length to facilitate moving the unit out of enclosure for cleaning or service. Tubing should be soft instead of rigid and ends should be free of burrs.
• Copper tubing route must be above 35˚ F (1.7˚ C) to prevent water line from freezing.
• Do not use plastic water lines from the household plumbing to the water inlet valve connection on the refrigeration unit.
• Do not use the self-piercing feature of a saddle valve. The hole made by the
piercing lance is too small for the water flow rate required by the ice maker.
• If saddle valve is not used, place a separate shut-off valve in an easily accessible location between water supply and the unit. Do not locate shut-off valve behind the unit.
• The installation of Viking units with a reverse osmosis system is acceptable
as long as the water pressure remains within the allowable PSI as stated below.
It is important to note that with many reverse osmosis systems, the pressure starts off high, but then it decreases as the water level of the reverse osmosis storage area drops. This must be considered when checking the water pressure coming into the unit.
• Connect a vertical or horizontal 1/2” (1.2 cm) to 1-1/4” (3.2 cm) COLD water line near water area.
• Run water line through the floor, back, or side wall. Tubing should lay flat on floor underneath the unit. Clamp tubing to wall or floor.
• Water pressure must be greater than 20 psi and less than 120 psi on non-dispensers and greater than 35 psi and less than 120 psi on dispensers.
37
Area Requirements
Verify the following:
• Unit can fit into residence and can be moved around corners and through doorways.
• Floors can support unit’s weight plus food
weight (approximately 1200 pounds [540 kg] total).
• Rear wall is solid and is able to support two horizontally mounted 2X4s (included) bolted to two wall studs. The 2X4 board bolt heads must be flush with 2X4 to prevent obstruction.
• Remove anything attached to rear or side walls that can obstruct unit installation.
• Cutout dimensions are accurate.
• Electrical outlet is in correct location.
• Water line is in correct location.
• Do not install a refrigeration unit near a heat source, nor in a location where the surrounding temperature will fall below 60º F (16º C).
Electrical Requirements
It is the customer’s responsibility to:
• Contact a qualified electrical installer.
• Assure that the electrical installation is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70­latest edition or Canadian Electrical Code C22.1-1998 and C22.2 No. 0-M91 (or latest edition), and all local codes and ordinances. A 115 volt, 60-Hz, 15 amp, fused, electrical supply is required. It is required that a separate circuit serving only
this appliance be provided. This appliance is equipped with a power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong, grounding-type wall receptacle.
Do not use an extension cord.
If codes permit a separate grounding wire to be used, it is recommended that a qualified electrician deter mine that the grounding path is adequate.
DO NOT ground to a gas pipe. Check with a qualified electrician if you are not sure the appliance is properly grounded. DO NOT have a fuse in the neutral or grounding circuit.
Anti-Tip Requirements
The anti-tip boards should be fastened into position prior to moving the unit into the opening.
NOTE: Additional mounting boards may be required if the unit does not touch the back wall of the enclosure. To prevent unit from tipping forward, it must be secured in place with a solid soffit or wood block.
36
General Information
C A U T I O N
Be sure to have a replacementcartridge available when filter change is required.
•If water filtration system has been allowed to freeze, replace filtercartridge.
•If system has not been used in several months, and water has an unpleasant taste or odor, flush system by dispensing 2-3 glasses of water. If unpleasant taste or odor persists, change filter cartridge.
W A R N I N G
To avoid serious illness or death, donot use unit where water is microbiologically unsafe orof unknown quality without adequate disinfection before or after the system. Systemscertified for cyst reduction may be used on disinfectedwater that may contain filterable cysts. The contaminants or other substances removed or reduced bythis water treatment system arenot necessarily in you water.
Page 20
39
1
2a
Place unit in front of cutout.
(Professional) Lift center grille louver up
and pull out.
2b
3
(Designer) Pull the center grille louver up
at an angle and pull out.
Using an 8” magnetic nut driver, remove
the two 1/4” screws.
4
Remove grille assembly.
• Most of the unit’s weight is at the top. Extra care is needed when moving the unit to prevent tipping.
• Do not remove protective film until unit is in operating position.
• All four leveling legs must contact the floor to support and stabilize the full weight.
• Do not drop unit.
• Remove exterior shipping materials prior to moving unit into home, except door latching device.
• Use two or more people to move and install unit. Failure to follow this instruction can result in back or other injury.
• To avoid personal injury, wear gloves when performing any installation procedure and wear eye protection when cutting metal straps.
TIP OVER HAZARD
Appliance is top heavy and tips easily when not completely installed. Keep doors closed until appliance is completely installed and secured per installation instructions. Use two or more people to move and install appliance. Failure to do so can result in death or serious injury.
Unpacking Unit
1. Remove top and bottom strap.
2. Remove top cap.
3. Cut carton rear approximately 1/4” (0.6 cm) to 1” (2.5 cm) from right corner with a utility knife extended 1/4” (0.6 cm).
4. Remove carton and exterior packaging. Save cardboard shipping material to protect floor surface when installing unit. Remove anti-tip board, kickplate and door trim pieces (DF models) from rear of unit.
38
Moving Unit
Remove shipping brackets from skid byremoving four bolts (two on each side) with a 1/2” deep-well socket
wench and a pair of pliers.
NOTE: Tilting unit is not required to remove
shipping brackets.
Slip appliance dolly between unit and skid. Remove
unit from skid.
NOTE: Use excess packaging to protect decorative
trim; also, verify that leveling legs are up (0”
adjustment).
General Information
Installation
Page 21
41
9
3”
3”3
10a
Plug in power cord to verifyoperation.
NOTE: Make sure power switch is in the “On” Position.
Place unit within 3” of being flush with cabinets.
NOTE: To avoid cabinet damage, place cardboard
between cabinets and unit. When moving unit, do not
crimp, kink or crush water supply line.
10b
11
Carefully move unit until semi flushwith cabinet
(depending on unit).
Pull supply tubing forward under unit.
NOTE: DO NOT use plastic water lines.
12
13
Flush water line by running two quarts of water
into a bucket. Turn water off.
Connect supply tube to water valve using
a 1/2” wrench. NOTE: DO NOT overtighten.
40
Remove four side screws and removeunit top.
Loosen the four hinge screws. Adjustdoor.
Retighten four hinge screws.
Replace unit top. Replace four side screws.
Attach one 2x4 to wall stud (refer to dimensionspage
for exact location).
If needed, depending on cabinet and depth,
attach second 2x4 to first 2x4.
2
1
5
Front of unit
2
1 3
6
1
2
7
8a
Wall
2 x 4
Refrigerator
8b
Wall
2 x 4
Refrigerator
Hinge Adjustment
Page 22
43
3
1
2
20
1
2
21
110˚
120˚
90˚
Open refrigerator door so door stopand shoulder
screw are accessible.
NOTE: Shoulder screw should be in 110˚ door opening
position.
Remove shoulder screw and place in90° or
120° position.
3
1
2
22
1
2
23
110˚110˚110˚
90˚
120˚120˚120˚
Open refrigerator door so door stopand
shoulder screw areaccessible.
NOTE: Shoulder screw should be in 110˚ door opening position.
Remove shoulder screw and place in
90˚ or 120˚ position.
42
Turn on water supply and check for leaks.
Lift unit off rollers to desired height and level unit using
a 5/16” head wrench.
NOTE: DO NOT use an electric device. Overtightening
can cause damage.
Attach positive secure self-tapping bolts to2x4
using a 22” extension.
Verify that drainpan is installed andaligned.
Align holes on both ends of louvered panels andinsert
screws.
Using a Phillips screwdriver, attach the
kickplate to the unit and adjust to desired height.
14
15
Wall
2 x 4
Refrigerator
Screw
16
17
1
2
18
2
1
3
19
Kickplate Installation
Door Stop Adjustment
(Side-by-Side)
Door Stop Adjustment (Bottom-Mount)
Page 23
4544
Locate water filter door. The door is located under
the Adjustable Cold Zone™ handle.
Push upper left corner of door to release latch
and pull door downward.
Insert filter cartridge into circular openingin filter housing. Rotate clockwise gently until filter stops.
Close water filter door.
NOTE: Allow 1-2 minute delay in water dispersal to
allow internal water tank to fill.
Flush air from the system byrunning water through the
dispenser continuously for 3 minutes.
24
2
1
25
1
3
2
26
27
Water Filter Installation (Side-by-Side with Dispenser)
Water Filter System Specification and Performance Data Sheet
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration of less than or e
qual to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.* (100% safety factors built-
i
n for unmetered usage for health claims only.)
*Tested using a flow rate of 0.5 gpm; pressure of 60 psig; pH of 7.5 +
0.5; temp of 68o+ 5oF (20o+ 3oC) **Measurement in particles/mL. Particles used were 0.5 - 1 microns ***NTU = Nephelometric Turbidity units
Operating Specifications
Capacity: Certified for up to 750 gallons (2,838 L); up to nine months Pressure Requirement: 20 - 120 psi (2.8 - 8.2 bar) Temperature: 33-100
o
F (0.6 - 38oC)
Flow rate: 0.78 gpm (2.9 l/min.) Check for compliance with the state and local laws and regulations. Note: While the testing was performed under standard laboratory conditions, actual performance may vary. Must be installed and operated in accordance with manufacturer’s recommended procedures and guidelines. Installation instructions, parts and service availability, and standard warranty are included with the product when shipped. This drinking water system must be maintained according to manufacturer’s instruction, including replacement of filter cartridges.
Standard No. 42: Aesthetic Effects
Parameter USEPA Influent Influent Effluent %Reduction Min. Req.
McL Average Challenge Average Maximum Average Minimum Reduction
Concentrations Chlorine 1.88 mg/L 2.0 mg/L + 10% <0.05mg/L 0.06 mg/L >97.26% 96.84% > 50% T&O Particulates** 5,700,000 #/mL at least 29.83#/mL 140 #/mL 99.98% 99.91% >
85%
10,000 particles/mL
Standard No. 53: Health Effects
Parameter USEPA Influent Influent Effluent %Reduction Min. Req.
McL Average Challenge Average Maximum Average Minimum Reduction
Concentrations
Turbidity 1 NTU*** 10.73 NTU*** 11 + 1 NTU 0.36 NTU .049 NTU 97.09% 95.20% 0.5 NTU Cysts 99.95% Reduction 200,000 #/L min. 50,000/L <1 <1 >99.99% >99.99% >99.95%
Asbestos 99% Reduction 155 MF/L 10
7
& 108fibers/L <1 <1 >99.99% >99.99% 99%
fibers>10micrometers
Lead at pH 6.5 0.015 mg/L 0.153 mg/L 0.15mg/L + 10% <.001 <.001 >99.35% >99.35% 0.010 mg/L Lead at pH 8.5 0.015 mg/L 0.150 mg/L 0.15mg/L + 10% <.001 <.001 >99.35% 97.35% 0.010 mg/L Mercury at pH 6.5 0.002 mg/L 0.006 mg/L .006mg/L + -10% 0.00026 0.0005 98.72% 90.91% 0.002mg/L Mercury at pH 8.5 0.002mg/L 0.006 mg/L .006mg/L + -10% 0.0008 0.0015 98.72% 75.93% 0.002mg/L Lindane 0.0002 mg/L 0.002 mg/L .002mg/L + 10% 0.000025 0.00007 98.72% 96.50% 0.0002mg/L Atrazine 0.003 mg/L 0.00873 mg/L .009mg/L + 10% <.002 mg/L <.002 mg/L 76.99% 75.31% 0.003 mg/L Toxaphene 0.003 mg/L 0.015 mg/L .015mg/L + 10% <0.001 <0.001 92.97% 91.67% 0.003mg/L
Manufactured by: Cuno, a 3M company
1000 Apollo Road Eagan, MN 55121 (651) 450-4913
System tested and certified by NSF International against Standard 42 for the reduction of chlorine taste and odor, particulate Class I and Standard 53 for the reduction of Lead, Lindane, Atrazine, Mercury, Toxaphene, Cyst, Turbidity, and Abestos.
Page 24
4746
Replace top air grille.
Using an 8” magnetic nut driver, replace
the two 1/4” screws.
(Professional) Replace the center grille louver.
(Designer) Replace the center grille louver.
Open door. Display should flash.
Press “ACTIVATE CONTROLS” padand close door.
NOTE: There is a 6 minute delay before the unit starts.
28
29
30a
30b
31
32
Final Installation
Performance Checklist
h Verify cabinet size.
h Verify electrical supply and water supply
(if applicable).
h Install anti-tip device(s) and verify unit is
secure.
h Position unit in cutout, level at desired
height and secure unit.
h Plug-in unit and verify operation.
h Connect water supply (if applicable).
• Verify icemaker fill tube is properly inserted.
• Verify icemaker bail arm is down.
• Verify dispenser operation (if applicable).
h Align/square door(s).
h Verify drain pan is properly installed and
no leaks on water connection.
h Install kickplate.
h Remove internal packaging and labels
and wipe unit down.
Installer’s information:
Installer’s name:_____________________________
Installer’s company:_________________________
Date:________________________________________
Page 25
Control Panels
1. Press “Activate Controls” pad.
2. Verify unit is not in Sabbath Mode.
If in Sabbath Mode:
A. The Sabbath Mode will disable the interior lights, display (except three blue squares) and alarm.
(See picture below for visual indication of Sabbath Mode.)
To exit the Sabbath Mode:
B. Press and hold “Activate Controls” and then “Display Off” for 3 seconds. (The control will beep
three times to alert the user the Sabbath Mode has been exited.)
3. Verify unit is not in Showroom Mode.
If in Showroom Mode:
A. The Showroom Mode will disable the refrigerator system but all other functions are normal. These
include lights and control. (See picture below for visual indication of Showroom Mode.)
To exit Showroom Mode:
B. Press and hold “Activate Controls”; while holding, press and hold “Higher” and “Alarm Off”
together. (The control will beep three times to alert the user that Showroom Mode has been exited.)
4. Press “Alarm Off” and “Display Off” at the same time and hold until beeps (force start compressor).
5. All models need to be set at the 5th bar for Refrigerator and Freezer - factory setting.
4948
Verify Operations
Only authorized replacement parts may be used in performing service on the appliance. Do not repair or replace any part of the appliance unless specifically recommended in the manual. All other servicing should be referred to a qualified technician.
Record the following information indicated below. You will need it if service is ever required. The serial number and model number for your appliance are located on the identification plate mounted behind the top light.
Model number
_________________________________________
Serial number
_________________________________________
Date of purchase
_________________________________________
Date installed
_________________________________________
Dealer's name
_________________________________________
Address
_________________________________________
Service & Registration
Bottom Mount
Side by Side
Page 26
5150