Viking PMD240FTKSS Installation Guide

Page 1
Installation Guide
Flush Mount Kit for VMOD5240
PMD240FTKSS
Page 2
• Read all of the Installation Manual that is included with the DrawerMicro™ Oven before installing in the  ush mount con guration.
• Observe all governing codes, ordinances, and safety instructions.
1. Prepare cabinet opening as shown in Figures 1, 2A, 2B, 2C.
A
C
E
H
Note: the face of the shelf must
3
sit 1
M
N
/4" (44.45 mm) back from
the face of the cabinet.
shelf face
O
cabinet face
I
Figure 1
B
D
F
G
K
L
J
Parts Included
Qty.
PREF-B019MRP 0 Flush Mount
1
LX-CZB055MRE0
2
Mounting screws
A. 6" (152.40 mm) B. Suggested electrical outlet location C. Anti-Tip block D. 5" (127 mm) E. 3-1/2" (88.90 mm) F. 4" (101.60 mm) G. 24-3/16" (614.35 mm) minimum 24-1/2" (622.3 mm) maximum H. 14-13/16" (376.24 mm) to bottom of Anti-Tip block I. 1-1/16" (26.97 mm) J. 23-1/2" (596.90 mm) minimum depth K. 22-1/8" (561.97 mm) L. 1-3/4" (44.45 mm) M. 16-7/8" (428.62 mm) opening N. Floor must support 100 lb (45.4 kg) O. 1-3/4" (44.45 mm)
Figure 2A
Suggested electrical
outlet location
A
C
L
Top view
Anti-Tip block
No oven
A
B
A. 22" (558.8 mm) mounting cleat opening width B. 1/4" (6.35 mm) C. 1-1/16" (26.97 mm)
face
Drawer face
Mounting cleat
B
Cabinet
C
A. 22-1/8" (561.97 mm) mounting cleat opening width B. 24-3/16" (614.35 mm) minimum 24-1/2" (622.3 mm) maximum  ush opening width C. 3/4" (19.05 mm) shelf
Anti-Tip block
C
Figure 2B
Front view
2
Page 3
Move oven location downward for extended countertops for better viewing angle.
16
(428.62 mm)
ush opening
Front face of cabinet
7
/8"
height
3
/4" (19.05 mm)
3
1
/4" (44.45 mm)
front face of shelf
shelf
Anti-Tip
block
Figure 2C
2. Install de ector
Position deector vent and mark holes. Pre drill using a
Shelf detail showing the deector vent during installation.
1
/16" (1.57 mm) bit before mounting.
Figure 3A
3. Place the drawer adjacent to the wall or cabinet opening. Plug
the power supply cord into the electrical outlet.
4. Carefully guide the drawer into the prepared opening. Avoid
contact with the sides of the cutout opening and also pinching the cord between the oven and the wall.
5. Slide the drawer all the way back until the mounting  anges
touch the cleats mounted in the cabinet opening.
6. Open the drawer. Using the 4 holes on the drawer as a template,
pre drill the cabinet using a 1/16” (1.57 mm) bit. See Figure 4.
7. Secure the drawer with the 4 screws supplied.
Side view
Shelf detail showing the deector vent installed.
Figure 3B
Mounting ange
Figure 4
3
Page 4
Viking Range, LLC
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information, call 1-888-(845-4641)
or visit our web site at vikingrange.com in the U.S. or brigade.ca in Canada
061544-000 EN (111516)
Page 5
D’INSTALLATION INSTRUCTIONS
Kit de montage encastré VMOD5240
PMD240FTKSS
Page 6
• Veuillez lire toutes les instructions du Manuel d’installation inclut avec le tiroir à micro-ondes avant d’e ectuer le montage encastré.
• Veuillez respecter tous les codes de conduite, toutes les ordonnances et instructions de sécurité.
• Veuillez vous assurer de laisser ces instructions au consommateur.
1. Préparer l’ouverture de l’armoire comme illustré aux  gures 1, 2A, 2B et 2C.
A
C
E
H
M
N
Remarque : la façade de la
tablette doit être en retrait
3
de 1
/4 po (44,5 mm)de la
façade de l'armoire.
façade de la tablette
O
façade de l'armoire
I
Figure 1
B
D
F
G
K
L
J
Pièces fournies
Qté
PREF-B019MRP0
1
pour montage encastré
LX-CZB055MRE0
2
Vis de montage
A. 6 po (152,40 mm) B. Emplacement de la prise électrique suggéré C. Bloc antibasculement D. 5 po (127 mm) E. 3-1/2 po (88,90 mm) F. 4 po (101,60 mm) G. 24-3/16 po (614,35 mm) minimum 24-1/2 po (622,3 mm) maximum H. 14-13/16 po (376,24 mm) jusqu’au bas du bloc
antibasculement I. 1-1/16 po (26,97 mm) J. 23-1/2 po (596,90 mm) profondeur min minimum K. 22-1/8 po (561,97 mm) L. 1-3/4 po (44,45 mm) M. Ouverture de 16-7/8 po (428,62 mm) N. Le plancher doit être en mesure de supporter 100
lb (45,4 kg) O. 1-3/4 po (44,45 mm)
Vue du dessus
Figure 2A
Emplacement de la
prise électrique suggéré
Bloc antibasculement
A
C
L
Tasseau de montage
Façade de
tiroir
B
C
l'armoire
Bloc
antibasculement
C
Façade du
Remarque : la surface de montage du tasseau doit être en retrait de 1
de la façade de l'armoire [poussant la façade du tiroir vers l'extérieur de
Pas de four
A
B
1
/16 po (26,97 mm)
1
/4 po (6,35 mm) ].
A. Ouverture avec tasseau de montage d’une largeur
de 22 po (558,8 mm) B. 1/4 po (6,35 mm) C. 1-1/16 po (26,97 mm)
A. Ouverture avec tasseau de montage d’une largeur
de 22-1/8 po (561,97 mm) B. 24-3/16 po (614,35 mm) minimum 24-1/2 po (622,3 mm) maximum Largeur de l’ouverture encastrée C. Étagère de 3/4 po (19,05 mm) shelf
Figure 2B
Vue de face
6
Page 7
Pour les comptoirs
é
prolongés, veuillez déplacer l'emplacement du four vers le bas pour un meilleur angle de visibilité.
Devant de l'armoire
Figure 2C
2. Installer le dé ecteur comme le montre.
Détail de tablette qui illustre l'évent déecteur durant l'installation.
Faites un avant-trou avec un foret
Positionnez l'évent déecteur et marquez les trous.
1
/16'' (1,57 mm) avant de procéder au montage.
Hauteur de
l'ouverture
encastrée de
7
/8 po
16
(428,62 mm)
Étagère de
3
/4 po (19,05 mm)
Devant de la tablette
3
/4 po (44,45 mm)
de 1
Vue de côté
Bloc
antibasculement
Détail de la tablette montrant le déecteur de ventilation une fois install
Figure 3A
3. Placer le tiroir près de l’ouverture du mur ou de l’armoire. Brancher le cordon d’alimentation dans la prise électrique.
4. Guider avec précaution le four assemblé dans l’ouverture préparée. Éviter le contact avec les côtés de l’ouverture et également de pincer le cordon entre le four et le mur.
5. Glisser le tiroir complètement vers l’arrière jusqu’à ce que les rebords de montage touchent les tasseaux installés dans l’ouverture de l’armoire.
6. Ouvrir le tiroir. En utilisant les 4 trous sur le tiroir comme gabarit, pré-percer l’armoire avec une mèche de 1/16 po (1,57 mm). Voir Figure 4.
7. Fixer le tiroir à l’aide des 4 vis fournies.
Figure 3B
Figure 4
Mounting
Tasseau de montage
ange
7
Page 8
Viking Range, LLC
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
Pour des informations sur les produits, appelez le 1-888-845-4641
ou allez sur le site web www.brigade.ca
061544-000 FR (111516)
Loading...