Viking F20712D Installation Manual

Installation Guide
Freestanding French Door
Bottom-Mount Refrigerator/Freezer
with Dispenser
Table of Contents
Warnings & Important Information_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 Dimensions (36” Bottom-Mount & French Door Bottom-Mount) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 6 Specifications (36” Bottom-Mount & French Door Bottom-Mount) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 7 Proper Disposal _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 8 Important Safety Instructions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 8 General Information _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 9
Door & Drawer Removal
Installation
2
IMPORTANT
It is the customer’s responsibility to:
• Contact a qualified electrical installer.
• Read all instructions before using the
refrigerator.
• Observe all local codes and ordinances.
Install refrigerator according to installation instructions. All connections for water, electrical power and grounding must comply with local codes and be made by licensed personnel when required.
• DO NOT modify plug on power cord. If
plug does not fit electrical outlet, have proper outlet installed by a qualified technician. Replace worn power cords and/or loose plugs.
• Assure that the electrical installation is
adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition or Canadian Electrical Code C22.1-1998 and C22.2 No. 0-M91 (or latest edition), and all local codes and ordinances. (115 volt, 60-Hz, 15 amp, fused, electrical supply is required. It is required that a separate circuit serving only this appliance be provided. This appliance is equipped with a power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong, grounding type wall receptacle. If a 2-prong receptacle is encountered, the customer must contact a qualified electrical installer to have it replaced with a properly grounded 3-prong receptacle. DO NOT use an extension cord or adapter plug.
• DO NOT ground to a gas line or cold-
water pipe.
• DO NOT remove warning tag from power
cord.
• Refrigerator is designed to operate on a
separate 115 volt, 15 amp., 60 cycle line.
• DO NOT tamper with refrigerator controls.
• DO NOT service or replace any part of refrigerator unless specifically recommended in Use & Care or Installation Instructions. DO NOT attempt service if instructions are not understood or if they are beyond personal skill level.
• Always disconnect refrigerator from electrical supply before attempting to change light bulbs, clean, or service the refrigerator. Disconnect the power cord by grasping the plug, not the cord.
• Always read and follow manufacturer’s storage and ideal environment instructions for items being stored in refrigerator.
• DO NOT allow children to operate, play with, crawl inside or stand on any part of the refrigerator.
• DO NOT clean refrigerator parts with flammable fluids. The fumes can create a fire hazard or explosion.
• Clean up spills or water leakage associated with water installation.
• Keep your refrigerator in good condition. Bumping or dropping refrigerator can damage refrigerator or cause refrigerator to malfunction or leak. If damage occurs, have refrigerator checked by qualified service technician.
3
Please Read and Follow
Refrigerator Safety
4
IMPORTANT5– Please Read and Follow
A GFI
shall be used if required by NFPA­70 (National Electric Code), federal/state/local laws, or local ordinances.
• The required use of a GFI is normally
related to the location of a receptacle with respect to any significant sources of water or moisture.
• Viking Range, LLC will NOT warranty any
problems resulting from GFI outlets which are not installed properly or do not meet the requirements below.
If the use of a GFI is required
, it should be:
• Of the receptacle type (breaker type or
portable type NOT recommended)
• Used with permanent wiring only
(temporary or portable wiring NOT recommended)
• On a dedicated circuit (no other
receptacles, switches or loads in the circuit)
• Connected to a standard breaker of
appropriate size (GFI breaker of the same size NOT recommended)
• Rated for Class A (5 mA +/- 1 mA trip
current) as per UL 943 standard)
• In good condition and free from any
loose-fitting gaskets (if applicable in outdoor situations)
• Sheltered from moisture (water, steam,
high humidity) as much as reasonably possible
Dimensions (Professional)
6
36” Professional French Door
35-7/8”
w/side panels accessory
(91.1 cm)
44-3/16”
(112.2 cm)
71-7/8”
(182.6 cm)
min.
to
72-5/8”
(184.5 cm)
max.
24-3/4”
(62.9 cm)
28-1/8”
(71.4 cm)
35-5/8”
(90.5 cm)
23-1/2”
(59.7 cm)
26-1/8”
(66.4 cm)