DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR
ANY OTHER APPLIANCE. THE FUMES CAN CREATE A FIRE HAZARD OR EXPLOSION.
•located so the front is not blocked to restrict incoming or discharge air flow.
•properly leveled.
•located in a well ventilated area.
•connected to the proper kind of outlet, with the correct electric supply and grounding. A 115 volt, 60 Hz, 15 amp
fused electrical supply is required.
•not used by anyone unable to operate it properly.
•used only for its intended purpose.
•properly maintained.
NNOOTTEE::
Time delay fuse or circuit breaker is recommended.
•SAVE THESE INSTRUCTIONS•
PROPER DISPOSAL OF YOUR OLD REFRIGERATION PRODUCT
DANGER
SUFFOCATION HAZARD
Remove doors from your old refrigerated beverage center.
Failure to do so can result in child entrapment, which can cause death
or brain damage.
IMPORTANT: Child entrapment and suffocation are not problems of the
past. Junked or abandoned refrigerated beverage centers are still
dangerous, even if they will sit for “just a few days.” If you are getting rid
of your refrigerated beverage center, please follow the instructions below
to help prevent accidents.
BEFORE YOU THROW AWAY YOUR OLD REFRIGERATION PRODUCT:
•Take off the doors.
•Leave the shelves in place so that children may not easily climb inside.
41009338
Rev B
UNDERCOUNTER CABINET CUTOUT
AA
24” (61.0 cm)*
BB
Min. 34 1/2” (87.6 cm)
Max. 35 1/8” (89.2 cm)
CC
24” (61.0 cm)
*24” width for cabinet only. 24 1/4” (61.6 cm)
need for cabinet and door width clearance if
door is recessed between cabinets.
SPECIFICATIONS/DIMENSIONS
PROFESSIONAL SERIES
BBaassiiccEElleeccttrriiccDDaattaa
•115 VAC/60 Hz
•Maximum amps - 3.3
•Approximate Shipping Weight - 140 lbs. (63.2 kg)
30 3/4”
(78.1 cm)
C
A
B
47 1/4” (120.0 cm)
Min. 34 1/4”
(87.0 cm)
Max 35”
(88.9 cm)
with leveling
legs fully
extended
23 7/8” (60.6 cm)
22” (55.9 cm)
24 3/8” (61.9 cm)
26 7/8” (68.3 cm)
2
SPECIFICATIONS/DIMENSIONS
DESIGNER SERIES
BBaassiiccEElleeccttrriiccDDaattaa
•115 VAC/60 Hz
•Maximum amps - 3.3
•Approximate shipping weight - 140 lbs (63.2 kg)
Side View
DUAR
47 1/4” (120.0 cm)
30 3/4”
(78.1 cm)
Front View
Mín.
34 1/4”
(87.0 cm)
Max.
35”
(88.9 cm)
with leveling
legs fully
extended
23 7/8” (60.6 cm)
22” (55.9 cm)
24 3/8” (61.9 cm)
25 3/8” ( 64.5 cm)
Side View
DFUR
47 1/4” (120.0 cm)
22” (55.9 cm)
24 3/16” (61.4 cm)
(to front of locally supplied
custom panel
3
GENERAL INFORMATION
UUnnppaacckk
1. Remove banding from bottom of carton. Lift carton up and off of the unit.
2. Remove all tape and packaging material from the outside and inside of the cabinet.
3. Keep all carton packaging until your refrigerated beverage center has been thoroughly inspected and found to be in
good condition.
AREA REQUIREMENTS
UUnniittssCCeerrttiiffiieeddffoorrIInnddoooorrUUssee--((bbllaacckkoouutteerrccaabbiinneett))
MUST BE INSTALLED IN AN AREA PROTECTED FROM THE ELEMENTS, SUCH AS WIND, RAIN, WATER (SPRAY OR
DRIP).
1. Place unit so the front side will be completely unobstructed to provide proper air flow. The unit may be closed in
on the top and three sides, but the front
Installation should be such that the cabinet can be moved for servicing if necessary.
2. Unit should be in a well ventilated area with temperature above 55
are obtained at temperatures between 650F (180C) and 800F (270C) for built-in products and 650F (180C) and 900F
(320C) for freestanding products.
3. Provisions for electricity should be determined before placing unit in proper place.
1. Place unit so the front side will be completely unobstructed to provide proper air flow. The unit may be closed in
on the top and three sides, but the front
Installation should be such that the cabinet can be moved for servicing if necessary.
2. Unit should be in a well ventilated area with temperature above 400F (4.40C) and below 1100F (430C). Best results
are obtained at temperatures between 600F (160C) and 1000F (380C).
3. Provisions for electricity should be determined before placing unit in proper place.
MMUUSSTTBBEE
MMUUSSTTBBEE
unobstructed for air circulation and proper operation.
0
F (130C) and below 1100F (430C). Best results
unobstructed for air circulation and proper operation.
REVERSIBLE DOOR
Professional Series
(Glass Door Units Only)
You can change the door swing from right to left hinge very easily.
1. Simply unscrew the top hinge door swing pin with an 1/8”
allen drive unit and lift door off of the bottom hinge bracket.
Flip the door, remove the light switch activator and replace the
light switch activator on the other end of the door.
2. Remove the door swing pin from bottom right hinge. Move
the bottom, right hinge bracket to the upper, left side of the
cabinet and fasten it in place with its original mounting screws.
3. Install the hinge door swing pin into the top right hinge bracket
and move the bracket to the lower left side of the cabinet.
Fasten it in place with its original screws.
4. Place the plastic washer over the bottom door swing pin on
the top surface of the bottom, left hinge.
5. Position the door on the bottom, left hinge pin and push the
door under the top, left hinge.
6. Line-up the top left hinge hole with the door bushing hole and
insert swing pin. Screw down the door swing pin with the
1/8” allen drive unit until its head is flush with the top surface
of the top, left hinge.
7. Reposition the logo. Your installation is now complete.
(Disregard if hinge brackets are already attached)
1. Attach the top and bottom door hinge brackets to the door with the #10-32 machine screws and a 1/8” allen head
driver as shown in Figure 1 below.
2. Press in the shoulder bushings to the top and bottom door hinge brackets. Make certain that the shoulder is to the
outside of the door as shown in Figure 1 below.
3. Test fit the door to the unit to make certain door will hang correctly. The door is hung correctly when the top of the
door is parallel to the top of the unit. (See Figure 2) Adjustments can be made by loosening the door hinge
machine screws and moving the door hinge brackets on the door.
4. Tighten all four (4) machine screws after adjustments have been made.
5. Remove the door from the unit by removing the units top hinge set screw and angling the door off of the bottom