Viking ES-1 Technical Practice

ES-1
ES-1
Stand Alone Door
Controller Entry System
February 15, 2005
iinnffoo@@vviikkiinnggeelleeccttrroonniiccss..ccoom
m
hhttttpp::////wwwwww..vviikkiinnggeelleeccttrroonniiccss..ccoom
m
Power: 120V AC/12V DC 500mA, UL listed adapter provided or use any 12-24V AC or DC source @ 100mA (designed to share power with the door strike’s power supply)
Dimensions: 133mm x 89mm x 44mm (5.25” x 3.5” x 1.75”) Shipping Weight: 1.3 kg (3 lbs) Environmental: 0° C to 32° C (32° F to 90° F) with 5% to 95%
non-condensing humidity
Relay Contact Ratings: 5A @ 30V DC/250V AC maximum Maximum Wiegand Length: 732m (2000 ft) - 24 AWG Maximum LOG BUS Length: 1610m (5280 ft - 1 mile), 24 AWG Connections: 11 screw terminals, (1) RJ-11 telco jack
Add Keyless Entry and/or Card Reader Entry
for a Single Door with Up to 250 Users
The ES-1 is a door controller designed to operate a door strike or magnetic lock upon receiving a valid card read and/or keyless entry code from Wiegand devices. One ES-1, one or two Wiegand devices and a door strike or magnetic lock of your choice is required for each entry point.
The Wiegand device used may be the Viking model HID-1 Proximity Card Reader and/or the Viking model HID-2 Wiegand Output Keypad or any other card reader, RF transmitter or digital keypad that out­puts the 26 bit Wiegand format. If two Wiegand
devices are used, one can be placed on each side of a doorway to control access in both directions (entry and exit). Up to 250 valid Wiegand codes can be programmed into the ES-1.
Other programmable parameters, like relay activation, mode (normal, off, or open) and facility codes are also stored in non-volatile memory. All programming is done with a local touch tone phone. Up to three ES-1s can be programmed simultaneously if they will be sharing all the same programming codes and parameters. Entry logging is possible with the ES-1’s log bus data output.
PPrraaccttiicce
e
T
T
EELLEECCOOM
M
S
S
OOLLUUTTIIOONNSSFFOORRTTHHE
E
221
1
SST
T
C
C
EENNTTUURRY
Y
TECHNICAL
TECHNICAL
SSppeecciiffiiccaattiioonns
s
FFeeaattuurrees
s
• Up to 250 tenants
• Program and control with a Touch Tone phone
• Use with any 26 bit Wiegand device
• Supports 1 entry point
• Compatible with Viking models HID-1 and HID-2
• Non-volatile memory (no batteries required)
• LOG BUS data output for logging entry events
• Card plus keypad mode for highest security
• One time codes for visitors
• Bi-directional (entry and exit) control
PPhhoonnee......771155..338866..8888661
1
AApppplliiccaattiioonns
s
• Business entrances
• High rise apartment buildings
• Condos
• Senior citizen buildings
• Assisted care centers
• Retirement homes
• Gated communities
IF YOU HAVE A PROBLEM WITH A VIKING PRODUCT, PLEASE CONTACT: VIKING TECHNICAL SUPPORT AT (715) 386-8666
Our Technical Support Department is available for assistance Monday 8am-4pm and Tuesday-Friday 8am - 5pm central time. So that we can give you better service, before you call please:
1. Know the model number, the serial number and what software version you have (see serial label).
2. Have your Technical Practice in front of you.
3. It is best if you are on site.
WARRANTY
Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of one year from the date of purchase from any authorized Viking distributor or 18 months from the date manu­factured, which ever is greater. If at any time during the warranty period, the product is deemed defective or malfunctions, return the product to Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI., 54016. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (R.A.) number.
This warranty does not cover any damage to the product due to lightning, over voltage, under voltage, accident, misuse, abuse, negligence or any damage caused by use of the product by the purchaser or others.
Vikings sole responsibility shall be to repair or replace (at Viking's option) the material within the terms stated above. VIKING SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING INCIDENTAL OR CONSE­QUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESSED OR IMPLIED, OR FOR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limi­tation of incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY EXCLUDED BEYOND THE ONE YEAR DURATION OF THIS WARRANTY. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
RETURNING PRODUCT FOR EXCHANGE
The following procedure is for equipment that has failed out-of-box (within 10 days of purchase
):
1. Customer must contact Viking’s Technical Support at 715-386-8666 to determine possible causes for the problem. The
customer MUST be able to step through recommended tests for diagnosis.
2. If the Technical Support Product Specialist determines that the equipment is defective based on the customer's input and troubleshooting, a Return Authorization (R.A.) number will be issued. This number is valid for fourteen (14) calendar days from the date of issue.
3. After obtaining the R.A. number, return the approved equipment to your distributor
, referencing the R.A. number. Your distributor will then replace the product over the counter at no charge. The distributor will then return the product to Viking using the same R.A. number.
4. The distributor will NOT exchange this product without first obtaining the R.A. number from you. If you haven't followed the steps listed in 1, 2 and 3, be aware that you will have to pay a restocking charge.
RETURNING PRODUCT FOR REPAIR
The following procedure is for equipment that needs repair:
1. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (RA)
number. The customer MUST have a complete description of the problem, with all pertinent information regarding the defect, such as options set, conditions, symptoms, methods to duplicate problem, frequency of failure, etc.
2. Packing: Return equipment in original box or in proper packing so that damage will not occur while in transit. Static sensitive equipment such as a circuit board should be in an anti-static bag, sandwiched between foam and individual­ly boxed. All equipment should be wrapped to avoid packing material lodging in or sticking to the equipment. Include ALL parts of the equipment. C.O.D. or freight collect shipments cannot be accepted. Ship cartons prepaid to:
Viking Electronics, 1531 Industrial Street, Hudson, WI 54016
3. Return shipping address: Be sure to include your return shipping address inside the box. We cannot ship to a PO Box.
4. RA number on carton: In large printing, write the R.A. number on the outside of each carton being returned.
DDeeffiinniittiioonns
s
26 Bit Wiegand Format: The industry standard data output of access control card readers.
Bi-Directional Access: Two Wiegand devices can be wired in parallel to one ES-1 to control access in both
directions at a single entry point. Simply place one card reader on each side of the door or gate. When either one detects a valid code, the ES-1 will strike the door. Data logging will not be able to distinguish the direction of the access. If that is a requirement, two separate ES-1s will need to be installed, so each one can log sepa­rate access events from each side of the door.
Card Plus Keypad Mode: This is a higher security mode in which a valid card + a valid keypad entry is required to gain access.
Entry Code: The number that when it matches either a Keyless Entry or a Proxy Card number, allows access. Each tenant may have their own unique Entry Code that is easily changed or removed when a tenant moves out.
Entry Point: A door or gate allowing access into a secure or controlled area.
Facility Code: A 3-digit number that each proxy card contains in order to provide greater security. Usually the
cards used at a given building all have the same facility code.
Keyless Entry: A way for tenants to let themselves in, by entering their entry code on a keypad.
LOG BUS: A two wire data bus that can be wired in parallel with additional ES-1 log busses. Data is sent as
1200 baud ASCII characters at TTL levels (0-5 Volt). Any RS-232 port designed to receive TTL levels can receive log bus data directly on the “Receive Data” and “Signal Ground” pins.
Memory Location: The number used when programming, that stores the location of an entry code.
One Time Code: An entry code that can only be used once - this feature is handy for visitors. Once the code is used the ES-1 forgets it.
Proxy Card: A credit size card that identifies itself when within close proximity of a reader. Card “swiping” is not
necessary. The card contains a 3 digit Facility Code, a 5 digit Internal Card number and a 5 digit External Printed number, that may or may not match the Internal number.
Proxy Card Reader: A device used to read the data from a Proxy Card when its held within a few inches of the reader.
IInnssttaallllaattiioon
n
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the
telephone line. It is recommended that a surge protector be installed to protect against such surges. Contact Panamax at (800) 472-5555 or Electronic Specialists Inc. at (800) 225-4876.
!
* Note: Maximum Wiegand run length is 2000 feet using 24 gauge wire when using the Viking Model HID-1 proxy card reader, and 4000 feet for the HID-2 keypad. Run length is reduced in half if two share the same wire run from the same ES-1 entry point. Run length will also be reduced if using a Wiegand device other than the Viking Model HID-1, that requires more than 35mA average operating current. Run lengths can be doubled by doubling up on the BLACK and RED 24 gauge wire, or using 21 gauge (or larger) wire. Certain electri­cally noisy locations might require shielded wire.
A. Basic Wiring
B. Gang Programming Wiring
A basic door access controlled entry point is wired as shown below. The relay can be connected as either Normally Open, or Normally Closed. All 26-bit Wiegand devices are fully supported (power and data) from the ES-1 and can be installed up to 500 feet away using 24 gauge wire. Viking Wiegand devices can run even further (see Note above). The ES-1 can support either a card reader (Viking model HID-1) or a keyless entry keypad (Viking model HID-2), or both. If both are installed, the “Card Plus Keypad” mode can be used. If any two Wiegand devices are used, one can be placed on each side of a doorway/gate for bi-directional (entry and exit) access control.
If multiply ES-1s are installed to handle door access control for multiple entry points, two or three of them can be pro­grammed simultaneously if they are to be programmed identically. Do this by wiring GANG PROG COMM screw ter­minals 1 together, and screw terminals 2 together. The touch tone programming phone connected to any one of them will program all of them simultaneously.
?
Need More Information on the HID-2?
Call (715) 386-4345 and select 199.
?
Need More Information on the HID-1?
Call (715) 386-4345 and select 197.
©
MODEL ES-1
VIKING
ELECTRONICS
HUDSON, WI 54016
STAND-ALONE
DOOR CONTROLLER
ENTRY SYSTEM
GANG PROG
LOG
COMM
BUS
ENTRY POINT
WIEGAND
DEVICE
BLK
RED
GRN
WHT
Doorstrike
Power Supply
5A@30VDC/250VAC
maximum
(not included)
12V DC Adapter
Included
or
VIKING
POWER 12 VDC
Viking HID-2
Keypad
(not included)
(Power typically not
required for gate
Doorstrike/Magnetic Lock
(not included)
PROGRAM
PHONE
1219m (4000 ft) maximum
controllers.)
Remote Touch Tone
Programming Phone
RAD-1 Remote Access
Device (not included)
Touch Tone
Programming Phone
609m (2000 ft) maximum
Viking HID-1
and/or
Proximity Card
Reader
or
(not included)
Touch Tone
Programming
Phone
VIKING
DOOR CONTROLLER
POWER 12 VDC
PROGRAM
PHONE
ENTRY SYSTEM
©
VIKING
ELECTRONICS
HUDSON, WI 54016
STAND-ALONE
GANG
LOG
PROG
BUS
COMM
1 2
MODEL ES-1
ENTRY POINT
WIEGAND
DEVICE
BLK
RED
WHT
GRN
609m (2000 ft) maximum
with 24 gauge wire
VIKING
DOOR CONTROLLER
POWER 12 VDC
PROGRAM
PHONE
©
MODEL ES-1
VIKING
ELECTRONICS
HUDSON, WI 54016
STAND-ALONE
ENTRY SYSTEM
LOG BUS
GANG PROG
COMM
ENTRY POINT
WIEGAND
DEVICE
BLK
RED
GRN
WHT
1 2 1 2
609m (2000 ft) maximum
with 24 gauge wire
VIKING
POWER 12 VDC
PROGRAM
PHONE
©
MODEL ES-1
VIKING
ELECTRONICS
HUDSON, WI 54016
STAND-ALONE
DOOR CONTROLLER
ENTRY SYSTEM
GANG
LOG
PROG
BUS
COMM
ENTRY POINT
WIEGAND
DEVICE
BLK
RED
GRN
WHT
Loading...
+ 5 hidden pages