Viking dva-3003 Service Manual

Telecommunication Peripheral Products
DVA-3003
3 Channel Digital Voice Announcer
Technical Practice
June 19, 2001
3 Channel Long Play Digital Announcer
The DVA-3003 is a professional and cost-effective three channel digital voice announcer specifically designed for ACD/UCD, hotel-motel wake up, auto attendant, intercept, night message, information applications and other announcement functions.
The DVA-3003 will increase call handling capacity by answering on demand or during the first ring, automatically adjusting the announce cycle to the message length, disconnecting on C.P.C. and providing instant “rewind” for the next caller.
The DVA-3003 is factory installed with 1 minute of record time per channel and may be expanded to 4 minutes per channel using the ERAM-60 one minute memory expansion kits. In applications where a single, longer message is required, the DVA-3003 can
VIKING©
also be configured as a single channel 3 to 12 minute announcer.
http://www.VikingElectronics.com
Features Applications
• Record time expandable from 1 to 4 minutes per channel
• Configurable as a 3-12 minute 1 channel announcer
• Record and review announcements both locally and remotely
• Tape jack to load prerecorded announcements from a tape player
• Record 1, 2, or all 3 channels simultaneously
• Programmable ring delay for each channel
• Detects C.P.C. signal and disconnects
• Callers may be transferred after announcement
• Messages stored in Non-volatile memory (no batteries required)
• Recognizes handshake signals from virtually any PABX, Centrex or C.O.
• Provides both “Ring Trip” and 4 wire “E & M” interface
• Recording volume level LED indicator for consistently high-quality recordings
• One year warranty
Repetitive Announcing for:
• School closings
• Wake-up calls
• Movie theaters
• Ski reports
• ACD/UCD or any announce only application where a message is repeated continuously and may require frequent updating.
• College events and schedules
• Bank rates/commodity prices
• Help desks
• Night Message
Specifications
Power: 120V AC/12V DC 500mA UL listed adapter provided or power from 48V DC 0.1 A maximum
Dimensions: 480mm x 200mm x 45mm (19” x 8” x 1.75”) Shipping Weight: 3 Kg (7lbs) Environmental: 0° to 32° C (32° to 90° F) with 5% to 95% non-
condensing humidity Message Length: 1 minute/channel, field expandable to 2, 3, or 4 minutes/channel using model ERAM-60 memory kits in (1) minute increments
Sampling Rate: 64 Kbps (equivalent) Connections: Standard ring-trip with adjustable ring delay, 4-wire
E & M with 600 ohm audio and switch selectable protocol
Installation
A. 120V AC Operation
The DVA-3003 is provided with a 120VAC U.L. listed adaptor with a 12VDC 500mA output. The DVA-3003 requires a 24 hour unswitched 115VAC outlet. To protect the internal electronics, the installation of a surge protector is recommended.
B. 48VDC Operation
Connect -48VDC and Earth Ground to the terminal block as shown below. Nominal current draw is less than 100mA. If a power supply protection fuse is used in series with the -48V supply, a 500mA slow blow fuse is recommended. The initial start up current can surge as high as 600-700mA.
BUSY
Dry contact closure for “E & M” busy signal or “A” Lead control for “ring trip”.
Earth GND (+) 6 M Lead (Start) 5 Tip (600 ohm) 4
CHANNEL 1
600 OHM
E & M
CO/PABX
LINE
Channel 1 ring trip
interface
Connect to “Ringing”
C.O. or PABX line.
1 - 48V 2 E Lead (Busy) 3 Ring (600 ohm)
PROGRAMMING
PORT
Connect to “ringing” C.O. line or PABX ext. for remote recording and programming when using “E & M” interface. If “Ring Trip” interface is used, channel 1 or the Programming Port may be used.
PROTOCOLS
5 6 7 8
E & M
USE ONLY LISTED
SOURCE 12VDC, 500mA
ON
OFF
MAX
or
48V GND
- 48VDC
Earth GND
(+)
CLASS 2 POWER
POWER
VIKING ELECTRONICS HUDSON WI. 54016
120V AC
Channel 1 four wire E & M interface
Programming
A. Standard Ring Trip Interface (Two Wire)
Any ringing C.O./PABX line will be answered, given an announcement and released. The DVA-3003 is then immediately ready to answer the next incoming call. Set the front panel DIP switches to RING TRIP for each channel using “Ring Trip” Interface, then momentarily disconnect power. *
B. Continuous Play 4 Wire E & M Interface
Set the front panel DIP switches to E & M for each channel using E & M Interface. Set “E & M protocols” DIP switches to “A” (DIP switches 5 and 6 off). Invert the START signal (DIP switch 7 on). *Momentarily disconnect the power. The announcement will be repeated continuously on pins 3 and 4 (600 ohm output).
C. 600 Ohm 4 Wire E & M Protocols
First set the front panel DIP switches to E & M for each channel using E & M Interface, then momentarily disconnect power.* Four different protocols are now switch selectable for changing E & M timing, plus the ability to invert the START and/or BUSY signals.
Front Panel DIP Switches
Channel
1 2 3
E & M
Ring
Trip
Single
Channel
* A momentary power down allows the DVA-3003 to read the new DIP switch settings.
2
ON
Rear Panel E $ M Protocols DIP Switches
SW 5 SW 6
PROTOCOL “A” OFF PROTOCOL “B” OFF PROTOCOL “C” ON For future use ON
SW 7 Inverted START signal when “ON” SW 8 Inverted BUSY signal when “ON”
OFF ON OFF ON
E & M
Protocols
ON
OFF
5 6 7 8
D. 600 Ohm 4 Wire E & M Protocol Timing Specifications
1. “ON DEMAND”. Set DIP switches to protocol “A” (SW 5 and SW 6 - OFF).
Contact from PABX
GND screw terminal or pin 6 on DVA-3003
Busy output
Earth
from DVA-3003
GND
2. TYPE 5 E & M, WINK START. Set dip switches to protocol “B” (SW 5 - OFF, SW 6 - ON). Contact from PABX
GND screw terminal or pin 6 on DVA-3003
Busy output
Earth
from DVA-3003
GND
3. DRUM RECORDER REPLACEMENT. Set dip switches to protocol “A” (SW 5 and SW 6 - OFF).
Pin 5 Start
GND screw terminal or pin 6 on DVA-3003
Pin 2
Busy output
Earth
from DVA-3003
GND
4. SINGLE PLAY ON DEMAND. Set dip switches to protocol “C” (SW 5 - ON, SW 6 - OFF). Contact from PABX
GND screw terminal or pin 6 on DVA-3003
Busy output
Earth
from DVA-3003
GND
Pin 5 Start
Idle/open
Pin 2 Idle/closed
In Use
Pin 5 Start (M)
Idle/open
Pin 2 Wink (E)
Idle/closed
O M
*
Pin 5 Start
Idle/open
Pin 2 Idle/closed
In Use
600ms
(Programmable)
Announcement B
250msec. min.
250msec. max.
Announcement Duration
600ms
(Programmable)
Announcement
B O M
*
B
Announcement B O M
*
250msec. max.
Announcement
M
E
O
B O M
*
*
O M
*
250msec.
min.
Announce ment
GND (+) M Lead (START)
Open
GND (+) E Lead (BUSY)
Open
GND (+) M Lead (START)
Open
GND (+) E Lead (BUSY)
Open
GND (+) M Lead (START) (Connected to earth GND)
GND (+) E Lead (BUSY)
Open
GND (+) M Lead (START)
Open
GND (+) E Lead (BUSY)
Open
*NOTE: BOM = “Beginning Of Message” pulse. EOM = “End Of Message” pulse.
E. Using the DVA-3003 with Major PABX’S
Set Front Panel DIP Switches
Manufacturer
ATT (Dimension,
Horizon, etc. 4 Wire E & M)
ATT (System 75)
to:
E&M
E&M
Protocol Dip
Switches
Protocol A
with inverted busy signal
ON
OFF
5 6 7 8
Protocol A
with inverted busy signal
ON
OFF
5 6 7 8
Notes:
* Earth ground is the positive of the PABX system talk battery
Use 4 Wire E & M Interface. Connections: T & R to pins 3 & 4, M to pin 5, E to pin 2 and Earth Ground* to GND screw terminal.
Use 4 Wire E & M Interface and BUSY screw terminals. T & R to pins 3 & 4, SZ to pin 5, SZ1 to GND screw terminal, and S and S1 to BUSY screw terminals.
3
Loading...
+ 4 hidden pages