Viking DSCD Series, DSCD1304BSS Installation Manual

Viking Range Corporation
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information,
call 1-888-VIKING1 (845-4641)
or visit the Viking Web site at
vikingrange.com
(081610)
Viking Installation Guide
Designer Freestanding 30 Dual Fuel
Self-Clean Sealed Burner Range
All manuals and user guides at all-guides.com
all-guides.com
IMPORTANT–Read and Follow!
3
2
Table of Contents
Before beginning, please read these instructions completely and carefully.
DO NOT remove permanently affixed labels, warnings, or plates from product. This may void the warranty.
All local and national codes and ordinances must be observed. Installation must conform with local codes or in the absence of codes, the National Fuel Gas Code ANSI Z223.1/NFPA-54 –latest edition.
The installer must leave these instructions with the consumer who should retain for local inspectors use and for future reference.
In Canada: Installation must be in accordance with the current CAN/CGA B149.1 & 2 Gas Installation codes and/or local codes. Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part 1 and/or local codes.
In Massachusetts: All gas products must be installed by a Massachusetts licensed plumber or gasfitter. A T type handle manual valve must be installed in the gas supply line to the appliance.
Your safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others.
All safety messages will be preceded by the safety alert symbol and the word “DANGER,” “WARNING” or “CAUTION.” These words mean:
Hazards or unsafe practices
which WILL result in severe personal
injury or death.
DANGER
Hazards or unsafe practices
which COULD result in severe personal
injury or death.
Hazards or unsafe practices which
COULD result in minor personal injury or
property damage.
All safety messages will identify the
hazard, tell you how to reduce the chance
of injury, and tell you what can happen if
the instructions are not followed.
WARNING
CAUTION
Warnings & Important Safety Instructions _____________________________________________________3
Dimensions __________________________________________________________________________________6
Specifications ________________________________________________________________________________7
Clearance Dimensions (Proximity to Cabinets) ________________________________________________8
Clearance Dimensions (Wood/Composite Overlay) ___________________________________________9
Electrical & Gas Requirements ______________________________________________________________10
General Information ________________________________________________________________________12
Installation__________________________________________________________________________________13
Door Removal __________________________________________________________________________13
Leg Installation _________________________________________________________________________14
Electrical Connection (3 Wire) ___________________________________________________________15
Electrical Connection (4 Wire) ___________________________________________________________17
Leveling/Adjustments/Alignment________________________________________________________19
Anit-tip Device Installation ______________________________________________________________20
Connecting Gas & Electrical ____________________________________________________________21
Final Installation ________________________________________________________________________22
Door Replacement and Adjustment _____________________________________________________23
Final Preparation____________________________________________________________________________24
Performance Checklist ______________________________________________________________________24
Service & Registration ______________________________________________________________________25
All manuals and user guides at all-guides.com
IMPORTANT–Read and Follow!
5
4
DANGER
GAS LEAK HAZARD
To avoid risk of personal injury or death; leak testing of the
appliance must be conducted according to the manufacturers instructions. Before placing appliance in operation, always check for gas leaks with soapy water solution.
DO NOT USE AN OPEN FLAME TO
CHECK FOR GAS LEAKS.
DANGER
ELECTRICAL SHOCK HAZARD
To avoid risk of electrical shock,
personal injury or death; verify your appliance has been properly grounded in accordance with local codes or in absence of codes, with the National Electrical Code (NEC). ANSI/NFPA 70- latest edition.
WARNING
MOVING HAZARD
To avoid risk of severe personal injury; this appliance
requires two or more personnel while handling and moving. Possible use of appliance moving devices is recommended.
DANGER
FIRE/EXPLOSION HAZARD
IF THE INFORMATION IN
THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
DO NOT store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
DO NOT try to light any appliance. DO NOT touch any electrical switch;
DO NOT use any phone in your building.
Immediately call your gas supplier from
a neighbors phone. Follow the gas suppliers instructions. If you cannot reach your gas supplier,
call the fire department.
Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
DANGER
CHEMICAL HAZARD
To avoid risk of property damage and/or personal injury or death; this appliance is not
too be used as a heating source.
Benzene is a chemical which is part of the gas supply to this cooking product, which is consumed in the flames during combustion. Exposure to a small amount of benzene is possible if a gas leak occurs. Formaldehyde and soot are by-products of incomplete combustion.
This appliance contains or produces chemicals which can cause serious injury or death and which are known to the state of California to cause cancer, birth defects or other reproductive harm. To reduce the risk from substances in the fuel or from fuel combustion make sure this appliance is installed, operated, and maintained in accordance to the instructions in this document.
WARNING
TIPPING HAZARD
To reduce the risk of property damage or personal injury; install anti-tipping device provided in accordance with the installation instructions in this document. Device must be engaged properly to prevent product from tipping over.
This range can tip.
Injuries to persons can result.
Install anti-tip device packed with range.
See installation instructions.
WARNING
To prevent possible damage to cabinets and cabinet finishes, use only materials and finishes that will not discolor or delaminate and will withstand temperatures up to 194°F (90°C). Heat resistant adhesive must be used if the product is to be installed in laminated cabinetry. Check with your builder or cabinet supplier to make sure that the materials meet these requirements.
A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or local ordinances.
The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture.
Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below.
If the use of a GFI is required
, it should be:
Of the receptacle type (breaker type or portable type NOT recommended)
Used with permanent wiring only (temporary or portable wiring NOT recommended)
On a dedicated circuit (no other receptacles, switches or loads in the circuit)
Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT recommended)
Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard
In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations)
Protected from moisture (water, steam, high humidity) as much as reasonably possible
All manuals and user guides at all-guides.com
7
Dimensions
6
3
5
-
7
/
8
(
9
1
.
1
c
m
)
m
i
n
.
t
o
3
7
(
9
4
c
m
)
m
a
x
.
2
9
-
7
/8
(
7
5
.
9
c
m
)
Note: Unit shown with standard island trim.
*Add 3/8 (0.95 cm) to overall depth of ranges installed against a combustible wall.
35-7/8”
(91.1 cm) min.
to
37”
(94 cm) max.
25-3/4” (65.4 cm)
45” (114.3 cm)
19-1/4”
(48.9 cm)
24” (61.0 cm)
25” (63.5 cm)
28-1/4” (71.8 cm)
6”
(15.2 cm)
25” (63.5 cm)
1-1/2”
(3.8 cm)
26-1/2” (67.3 cm)
Dual Fuel 30 W. Range
Minimum clearances from adjacent combustible construction: Below cooking surface (36 [91.4 cm] and below)
Sides - 0”
Top grate support - 36” (91.4 cm)
Above cooking surface (above 36 [91.4 cm])
Sides - 6” (15.2 cm)
Within 6” (15.2 cm) side clearance, wall cabinets no deeper than 13 (33.0 cm) must be minimum 18 (45.7 cm) above cooking surface
Wall cabinets directly above product must be a minimum of 42 (106.7 cm) above cooking surface
Rear - 0” with 6” backguard or high shelf; 0” with island trim and non-combustible rear wall;
6 (15.2 cm) with island trim and combustible rear wall
Dual Fuel 30” W. Range
Description
DSCD
Overall width 29-7/8” (75.9 cm)
Overall height To top of side trim - 35-7/8” (91.1 cm) min. 37” (94.0 cm) max.
Legs adjust - 1-1/8” (2.9 cm)
Overall depth from rear
To front of side panel - 25” (63.5 cm)
To front of door - 25-3/4” (65.4 cm)
To front of landing ledge - 26-1/2” (67.3 cm)
To front of door handle - 28-1/4” (71.8 cm)
*Add 3/8” (0.95 cm) to overall depth of ranges installed against a combustible wall.
Additions to Overall Height
To top of island trim - add 0” (0.0 cm)
To top of backguard - add 6” (15.2 cm)
To top of high shelf - add 18-3/16” (46.2 cm)
Gas Requirements Shipped Natural or LP/Propane, field convert with conversion kit (purchased separately);
accepts standard residential 1/2” (1.3 cm) ID gas service line
Gas Manifold Pressure Natural 5.0” W.C.P./ Liquid Propane L/P 10.0” W.C.P.
Electrical Requirements 240-208 VAC 60 Hz electrical connection box on product, connect with locally supplied 3-
wire, flexible cord or “pigtail” rated 40 amp. 125-250 VAC minimum. Cord must be
agency approved for use with household electric ranges.
Max Amp Usage
240V - 25.4 amps 208V - 22.9 amps
Surface Burner Rating Natural/LP
Left front Left rear Right rear Right front
16,000 BTU Nat./12,500 BTU LP/Propane (4.7 kW Nat/ 3.7 kW LP/Propane) 12,000 BTU Nat./11,500 BTU LP/Propane (3.5 kW Nat/ 3.4 kW LP/Propane)
8,000 BTU Nat./7,500 BTU LP/Propane (2.3 kW Nat/ 2.2 kW LP/Propane) 6,000 BTU Nat./5,500 BTU LP/Propane (1.8 kW Nat/ 1.6 kW LP/Propane)
Oven Interior Width 25-5/16” (64.6 cm)
Oven Interior Height 16-1/2” (41.9 cm)
Oven Interior Depth Overall - 19-1/2” (49.5 cm)
AHAM - 16-13/16” (42.7 cm)
Oven Volume Overall AHAM
4.7 cu. ft.
4.1 cu. ft.
Approximate shipping weight
410 lbs.
(184.5 kg)
Specifications
All manuals and user guides at all-guides.com
4
2
m
i
n
.
(
1
0
6
.
7
c
m
)
1
3
m
a
x
.
(
3
3
.
0
c
m
)
6
m
i
n
.
(
1
5
.
2
c
m
)
1
8
m
i
n
.
(
4
5
.
7
c
m
)
3
/
8
(
0
.
9
5
c
m
)
3
6
(
9
1
.
4
c
m
)
2
9
-
7
/
8
(
7
5
.
9
c
m
)
A
(
o
p
e
n
i
n
g
w
i
d
t
h
)
Clearance Dimensions (Wood/Composite Overlay)
9
Clearance Dimensions (Proximity to Cabinets)
8
This range may be installed directly adjacent to existing 36” (91.4 cm) high base cabinets.
IMPORTANT: The side trim MUST be 3/8 (.95 cm) above the adjacent base cabinet countertop. This can be accomplished by raising the unit using the adjustment spindles on the legs.
The range CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36” (91.4 cm) high. There must be a minimum of 6” (15.2 cm) side clearance from the range to such combustible surfaces above the 36 (91.4 cm) counter height.
Within the 6 (15.2 cm) side clearance to combustible vertical surfaces above 36 (91.4 cm), the maximum wall cabinet depth must be 13 (33.0 cm) and wall cabinets within this 6 (15.2 cm) side clearance must be 18 (45.7 cm) above the 36” (91.4 cm) high countertop.
Wall cabinets above the range must be a minimum of 42” (106.7 cm) above the range cooking surface for the full width of the range. This minimum height requirement does not apply if a range hood is installed over the cooking surface.
The bottom of a standard hood should be 30” (76.2 cm) min. to 36” (91.4 cm) max. above the countertop. This would typically result in the bottom of the hood being 66” (167.6 cm) to 72” (182.9 cm) above the floor. Refer to the range hood installation instructions for additional information. These dimensions provide for safe and efficient operation of the hood.
6
6
m
in
.
(
1
6
7
.
6
c
m
)
t
o
7
2
m
a
x
.
(
1
8
2
.
9
c
m
)
3
0
(
7
6
.
2
c
m
)
6
(
1
5
.
2
c
m
)
W
o
o
d
/
C
o
m
p
o
si
t
e
O
v
e
r
l
a
y
3
0
m
in
.
(
7
6
.
2
c
m
)
t
o
3
6
m
a
x
.
(
9
1
.
4
c
m
)
6
6
m
in
.
(
1
6
7
.
6
c
m
)
t
o
7
2
m
a
x
.
(
1
8
2
.
9
c
m
)
2
4
(
6
1
.
0
c
m
)
o
r
2
7
(
3
8
.
6
c
m
)
W
o
o
d
/
C
o
m
p
o
si
t
e
O
v
e
r
l
a
y
0
(
0
c
m
)
3
0
m
in
.
(
7
6
.
2
c
m
)
t
o
3
6
m
a
x
.
(
9
1
.
4
c
m
)
Wall Installation
Island Installation
Note: Minimum clearance for back wall is 0” with backguard or high-shelf.
Note: If a range hood is installed, wall cabinets above the range have a different minimum clearance height.
CAUTION
Burn hazard.
To avoid risk of personal injury; the use of cabinets for storage
above the appliance may result in a potential burn hazard. Combustible items may ignite, metallic items may become hot and cause burns. If a cabinet storage is to be provided the risk can be reduced by installing a rangehood that projects horizontally a minimum 5 (12.7 cm) beyond the bottom of cabinets.
Note: Minimum clearance for back wall is 0” with backguard or high-shelf.
Important: This range comes standard with an Island Trim. There must be a minimum of 6” (15.2 cm) clearance from rear of range to a combustible wall or 0” clearance to a non-combustible wall.
Range Width
“A”
Dimension
30” 30” (76.2 cm)
All manuals and user guides at all-guides.com
Loading...
+ 9 hidden pages