• Before beginning, please read these
instructions completely and carefully.
• DO NOT remove permanently affixed
labels, warnings, or plates from product.
This may void the warranty.
• All local and national codes and ordinances
must be observed. Installation must
conform with local codes or in the absence
of codes, the National Fuel Gas Code ANSI
Z223.1/NFPA-54 –latest edition.
• The installer must leave these instructions
with the consumer who should retain for
local inspector’s use and for future
reference.
In Canada: Installation must be in accordance
with the current CAN/CGA B149.1 & 2 Gas
Installation codes and/or local codes. Electrical
installation must be in accordance with the
current CSA C22.1 Canadian Electrical Codes
Part 1 and/or local codes.
Your safety and the safety of others is
very important.
We have provided many important safety
messages in this manual and on your
appliance. Always read and obey all
safety messages.
This is the safety alert symbol. This
symbol alerts you to hazards that
can kill or hurt you and others.
All safety messages will be preceded by
the safety alert symbol and the word
“DANGER,” “WARNING” or “CAUTION.”
These words mean:
Hazards or unsafe practices
which WILL result in severe personal
injury or death.
Hazards or unsafe practices
which COULD result in severe personal
injury or death.
In Massachusetts: All gas products must be
installed by a “Massachusetts” licensed
plumber or gasfitter. A “T” type handle
manual valve must be installed in the gas
supply line to the appliance.
2
Hazards or unsafe practices which
COULD result in minor personal injury or
property damage.
All safety messages will identify the
hazard, tell you how to reduce the chance
of injury, and tell you what can happen if
the instructions are not followed.
3
IMPORTANT–Read and Follow!
DANGER
DANGER
WARNING
DANGER
DANGER
WARNING
WARNING
A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/local
laws, or local ordinances.
• The required use of a GFI is normally related to the location of a receptacle with respect to
any significant sources of water or moisture.
• Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which
are not installed properly or do not meet the requirements below.
If the use of a GFI is required
• Of the receptacle type (breaker type or portable type NOT recommended)
• Used with permanent wiring only (temporary or portable wiring NOT recommended)
• On a dedicated circuit (no other receptacles, switches or loads in the circuit)
• Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT
recommended)
• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard
• In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations)
• Protected from moisture (water, steam, high humidity) as much as reasonably possible
To prevent possible damage to cabinets
and cabinet finishes, use only materials
and finishes that will not discolor or
delaminate and will withstand temperatures
up to 194°F (90°C). Heat resistant
adhesive must be used if the product is to
be installed in laminated cabinetry. Check
with your builder or cabinet supplier to
make sure that the materials meet these
requirements.
, it should be:
FIRE/EXPLOSION
HAZARD
IF THE INFORMATION IN
THIS MANUAL IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL
INJURY, OR DEATH.
• DO NOT store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
• WHAT TO DO IF YOU SMELL GAS:
–DO NOT try to light any appliance.
–DO NOT touch any electrical switch;
DO NOT use any phone in your
building.
–Immediately call your gas supplier from
a neighbor’s phone.
–Follow the gas supplier’s instructions.
–If you cannot reach your gas supplier,
call the fire department.
• Installation and service must be
performed by a qualified installer, service
agency, or the gas supplier.
CHEMICAL HAZARD
To avoid risk of property
damage and/or personal injury
or death; this appliance is not
too be used as a heating source.
• Benzene is a chemical which is part of
the gas supply to this cooking product,
which is consumed in the flames during
combustion. Exposure to a small
amount of benzene is possible if a gas
leak occurs. Formaldehyde and soot are
by-products of incomplete combustion.
• This appliance contains or produces
chemicals which can cause serious
injury or death and which are known to
the state of California to cause cancer,
birth defects or other reproductive harm.
To reduce the risk from substances in
the fuel or from fuel combustion make
sure this appliance is installed,
operated, and maintained in accordance
to the instructions in this document.
ELECTRICAL SHOCK
HAZARD
To avoid risk of electrical shock,
personal injury or death; verify
your appliance has been properly
grounded in accordance with local codes
or in absence of codes, with the National
Electrical Code (NEC). ANSI/NFPA 70latest edition.
MOVING HAZARD
To avoid risk of severe
personal injury; this appliance
requires two or more personnel
while handling and moving. Possible
use of appliance moving devices is
recommended.
TIPPING HAZARD
To reduce the risk of property
damage or personal injury;
install anti-tipping device
provided in accordance with
the installation instructions in
this document. Device must be
engaged properly to prevent
product from tipping over.
• This range can tip.
• Injuries to persons can result.
• Install anti-tip device packed with range.
• See installation instructions.
GAS LEAK HAZARD
To avoid risk of personal injury
or death; leak testing of the
appliance must be conducted
according to the manufacturer’s
instructions. Before placing appliance in
operation, always check for gas leaks
with soapy water solution.
• DO NOT USE AN OPEN FLAME TO
CHECK FOR GAS LEAKS.
4
5
Dimensions
3
5
-
7
/
8
”
(
9
1
.
1
c
m
)
m
i
n
.
t
o
3
7
”
(
9
4
c
m
)
m
a
x
.
2
9
-
7
/8
”
(
7
5
.
9
c
m
)
35-7/8”
(91.1 cm) min.
to
37”
(94 cm) max.
25-3/4” (65.4 cm)
45” (114.3 cm)
19-1/4”
(48.9 cm)
24” (61.0 cm)
25” (63.5 cm)
28-1/4” (71.8 cm)
6”
(15.2 cm)
25” (63.5 cm)
1-1/2”
(3.8 cm)
26-1/2” (67.3 cm)
Specifications
Dual Fuel 30” W. Range
Note: Unit shown with standard island trim.
*Add 3/8” (0.95 cm) to overall depth of ranges installed against a combustible wall.
6
Dual Fuel 30” W. Range
Description
Overall width29-7/8” (75.9 cm)
Overall heightTo top of side trim - 35-7/8” (91.1 cm) min. 37” (94.0 cm) max.
Legs adjust - 1-1/8” (2.9 cm)
Overall depth
from rear
*Add 3/8” (0.95 cm) to overall depth of ranges installed against a combustible wall.
Additions to Overall
Height
Gas RequirementsShipped Natural or LP/Propane, field convert with conversion kit (purchased separately);
Gas Manifold PressureNatural 5.0” W.C.P./ Liquid Propane L/P 10.0” W.C.P.
Electrical Requirements 240-208 VAC 60 Hz electrical connection box on product, connect with locally supplied 3-
wire, flexible cord or “pigtail” rated 40 amp. 125-250 VAC minimum. Cord must be
Max Amp Usage
Surface Burner Rating
Natural/LP
Left front
Left rear
Right rear
Right front
Oven Interior Width25-5/16” (64.6 cm)
Oven Interior Height16-1/2” (41.9 cm)
Oven Interior DepthOverall - 19-1/2” (49.5 cm)
Oven Volume
Overall
AHAM
Approximate
shipping weight
Minimum clearances from adjacent combustible construction:
Below cooking surface (36” [91.4 cm] and below)
• Sides - 0”
• Top grate support - 36” (91.4 cm)
Above cooking surface (above 36” [91.4 cm])
• Sides - 6” (15.2 cm)
• Within 6” (15.2 cm) side clearance, wall cabinets no deeper than 13” (33.0 cm) must be minimum 18”
(45.7 cm) above cooking surface
• Wall cabinets directly above product must be a minimum of 42” (106.7 cm) above cooking surface
• Rear - 0” with 6” backguard or high shelf; 0” with island trim and non-combustible rear wall;
• 6” (15.2 cm) with island trim and combustible rear wall
accepts standard residential 1/2” (1.3 cm) ID gas service line
agency approved for use with household electric ranges.
• This range may be installed directly
adjacent to existing 36” (91.4 cm) high
base cabinets.
IMPORTANT: The side trim MUST be
3/8” (.95 cm) above the adjacent base
cabinet countertop. This can be
accomplished by raising the unit using
the adjustment spindles on the legs.
• Wall cabinets above the range must be a
minimum of 42” (106.7 cm) above the
range cooking surface for the full width
of the range. This minimum height
requirement does not apply if a range
hood is installed over the cooking surface.
The bottom of a standard hood should be
30” (76.2 cm) min. to 36” (91.4 cm) max.
above the countertop. This would typically
result in the bottom of the hood being
66” (167.6 cm) to 72” (182.9 cm) above the
floor. Refer to the range hood installation
instructions for additional information. These
dimensions provide for safe and efficient
operation of the hood.
• The range CANNOT be installed
directly adjacent to sidewalls, tall
cabinets, tall appliances, or other
side vertical surfaces above 36”
(91.4 cm) high. There must be a
minimum of 6” (15.2 cm) side
clearance from the range to such
combustible surfaces above the
36” (91.4 cm) counter height.
• Within the 6” (15.2 cm) side
Note: Minimum clearance
for back wall is 0” with
backguard or high-shelf.
clearance to combustible vertical
surfaces above 36” (91.4 cm), the
maximum wall cabinet depth
must be 13” (33.0 cm) and wall
cabinets within this 6” (15.2 cm)
side clearance must be 18”
(45.7 cm) above the 36”
(91.4 cm) high countertop.
Burn hazard.
To avoid risk of personal injury;
the use of cabinets for storage
above the appliance may result
in a potential burn hazard. Combustible
items may ignite, metallic items may
become hot and cause burns. If a cabinet
storage is to be provided the risk can be
reduced by installing a rangehood that
projects horizontally a minimum 5”
(12.7 cm) beyond the bottom of cabinets.
Wall Installation
Range
Width
30”30” (76.2 cm)
Note: Minimum clearance for back wall is 0” with
backguard or high-shelf.
“A”
Dimension
Important: This range comes standard
with an Island Trim. There must be a
minimum of 6” (15.2 cm) clearance from
rear of range to a combustible wall.
Clearances from non-combustible
materials are not part of the ANSI Z21.1
scope and are not certified by CSA.
Note: If a range hood is installed, wall cabinets
above the range have a different minimum
clearance height.
8
Island Installation
Clearances to non-combustible materials
must be approved by the authority having
jurisdiction.