Viking DIV600 Installation Manual

Model DIV600 Ventilator Kit
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN­JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac­turer. If you have questions, contact the manufacturer or your distributor.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the ser­vice disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhaust­ing of gases through the flue (chimney) of fuel burning equip­ment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with an additional speed control device.
8. To reduce the risk of fire, use only steel ductwork.
9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ig­nite. Heat oils slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when cooking flaming foods.
3. Clean ventilating fans frequently. Grease should not be al­lowed to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PRE­VENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels ­violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you
already know how to operate it. B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbal­anced impellers, keep drywall spray, construction dust, etc. off power unit.
3. Your ventilator motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor con­tinues to shut off and restart, have the hood serviced.
4. Please read specification label on product for further infor­mation and requirements.
!
For Use only with Hood Models:
DCWH3644 / DCWH4244 / DCWL 3944 /
DCWL4544 /DCIH3604 /DCIH4204 /
VCWH3048 / VCWH3648 / VCWH4248 /
VCIH3608 / VCIH4208
Blower Dimensions
11.271 x 11.281 x 10.610
1
Model DIV600 Ventilator Kit
VENTILATOR KIT INSTALLATION
1. Choose the correct VENTILATOR MOUNTING PLATE for your hood series.
2. Attach DAMPER to ventilator mounting plate, as shown. Use three (3) HEX SCREWS. Note: Damper FLANGE to be
captured by screw heads.
3. Slide mounting plate / damper assembly into hood and onto four (4) THREADED STUDS, as shown. Slide four (4) NEOPRENE WASHERS onto threaded studs to temporarily hold plate to hood.
4. Rotate ventilator 90
5. Rotate ventilator back to orientation shown.
6. Fasten ventilator to four (4) threaded studs, using four (4) HEX NUTS.
7. Plug ventilator’s POWER CORD into RECEPTACLE inside the hood.
0
and lift into position inside hood.
Ventilator configuration for VCWH Series hoods
(30" to 42" wide, 18" high)
TOP OF HOOD
THREADED
STUDS
HEX SCREWS
DAMPER
FLANGE
NEOPRENE
WASHERS
VCWH
SERIES
VENTILATOR
MOUNTING
PLATE
RECEPTACLE
Ventilator configuration for DCW / DCI Series hoods
(36" to 45" wide, 14" high)
TOP OF HOOD
THREADED
STUDS
DAMPER
FLANGE
NEOPRENE
WASHERS
HEX SCREWS
DCW / DCI
SERIES
VENTILATOR
MOUNTING
PLATE
RECEPTACLE
VENTILATOR
HEX NUTS
POWER
CORD
POWER
CORD
VENTILATOR
HEX NUTS
2