Basic Specifications - VGRT Models
Description 36" W. Models 42" W. Models
Overall width
Overall height
Overall depth from
_ear
Cutout width
Cutout Height
Cutout Depth
Electrical
_equirements
Gas requirements
35 7/8" (91.1 cm) 42" (106.7 cm)
To top of spider grate - 9 1/4" (23.5 cm)
To top of burner grate - 9 1/8" (23.2 cm)
To top of island trim - 8 7/8" (22.5 cm)
To top of 6" backguard- 13 7/8" (35.2 cm)
To top of high shelf -
48" W. Models 60" W. Models
47 7/8" (121.6 cm) 59 1/2" (151.1cm)
(Open top Burners only)
(Sealed Burners only)
31 3/8" (79.7 cm)
To end of side panel - 24" (61.0 cm)
To end of control panel - 25 3/4" (65.4 cm)
To end of knobs - 27 3/4" (70.5 cm)
36" (91.4 cm) 42 1/8" (107 cm) 48" (121.9 cm) 59 5/8" (151.4 cm)
Open top Burners - 7 1/2" (19.1 cm) (top of grate support should be 3/8" [1.0 cm] above countertop.
Sealed Burners - 7 5/8" (19.4 cm) (top of side trim should be 3/8" [1.0 cm] above countertop.
Minimum 24" (61.0 cm) Maximum 25 3/4" (65.4 cm)
120 VAC/60 Hz 4ft. (121.9 cm), 3-wire cord with grounded 3-prong plug
Shipped natural or LP/Propane gas; field convertible with conversion kit (purchases separately);
accepts standard residential 1/2" (1.3 cm) ID gas service line
Maximum amp
usage
6B - .6amps
4G - 3.9amps
4Q - .6amps
6G - 4.2 amps
6Q - .6 amps
4G - 7.2 amps
4GQ- 4.2 amps
4K - .6 amps
4Q - .6 amps
Surface burner
_ating
_Vok Burner
_ating (if applicable)
Griddle burner
_ating
BTU LP
Grill burner
_atJng
Approximate
Shipping Wt.
6G - 7.8 amps
6GQ- 4.2 amps
15.000 BTU Nat./13,500 BTU LP/Propane
(4.4 kW Nat./4.0 kW LP/Pro)ane)
N/A 27,800 BTU Nat./LP N/A
(8.2 kW Nat./LP
12"/18" Wide
15,000 BTU Nat./13,500 BTU LP
(4.4 kW / 4.0 kW )
12" Wide - 1 @ 18,000 BTU Nat. (5.3 kW)/16,000 BTU LP/Propane (4.7 kW)
24" Wide - 2 @ 15,000 BTU Nat. (4.4 KW) / 13,500 BTU LP/Propane (4.0 kW)
6B-150 Ib.(67.Skg) 6G -203 Ib.(91.4kg) 6G - 2561b.(115.2kg)
4G - 160 Ib.(72.0kg) 6Q -198 Ib.(89.1kg) 6GQ-251 Ib.(113.0kg)
4Q - 155 Ib.(69.8 kg) 4G - 213 Ib.(95.6kg)
4GQ-208 Ib.(93.6 kg)
4K - 213 Ib.(95.6 kg)
4Q - 198 Ib.(89.1 kg)
24" Wide
Two 15,000 BTU Nat./13,500
(4.4 kW / 4.0 kW)
MINIMUM CLEARANCES
Minimum clearances from the product to adjacent surfaces or construction:
• Below 36" (91.4 cm)
Sides- 0"
Rear- 0"
• Above 36" (91.4 cm)
Sides- 6" (15.2 cm)
Within the 6" (15.2 cm) side clearance, wall cabinets shall be no deeper than 13" (33.0 cm) and must be a minimum of 18"
(45.7 cm) above the countertop.
Rear - 0" with backguard or high shelf
0" with island trim and non-combustible heat resistant rear wall
B" (15.2 cm) with island trim and combustible rear wall
• Wall cabinets directly above the product must be minimum of 36" (91.4 cm) above the countertop for open top burners and 42"
(108.7 cm) for sealed burners.
To maintain product warranty, the responsibility for ensuring the use of non-combustible heat resistant materials when required, lies
with individual owner, contractor or end user.
*it is not recommended to install two or more units side by side.
Basic Specifications - DGRT Models
Description
Overall width
Overall height
Overall depth from
rear
Cutout width
Cutout Height
Cutout Depth
Electrical
requirements
Gas requirements
Maximum amp
usage
Surface burner rating
left front
left rear
center
right rear
right front
Approximate
Shipping Wt.
30" W. Models
29 7/8" (759. cm)
To top of grate - 6 1/8" (15.6'cm)
To top of island trim - 6 1/8" (15.6 cm)
To top of 6" backguard- 12 1/8" (30.8 cm)
To top of high shelf - 24 1/8" (61.3 cm)
To end of side panel - 24 1/2" (62.2 cm)
To end of control panel - 26 1/8" (66.4 cm)
To end of knobs - 27 5/8" (70.5 cm)
30" (76.2 cm) 36" (91.4 cm)
5 3/4" (14.6 cm) (top of grates should be 3/8" [1.0 cm] above countertop.
36" W. Models
35 7/8" (91.1 cm)
24 1/2" (62.2 cm)
120 VAC/60 Hz 4ft. (121.9 cm), 3-wire cord with grounded 3-prong plug
Shipped natural or LP/Propane gas ; field convertible with conversion kit (purchased separately);
accepts standard residential 1/2" (1.3 cm)ID gas service line
2.0 amps 2.0 amps
16,000 BTU Nat./15,500 BTU LP/Propane
(4.7 kW Nat./4.5 kW LP/Propane)
12,000 BTU Nat./11,500 BTU LP/Propane
(3.5 kW Nat./3.4 kW LP/Propane)
N/A
12,000 BTU Nat./11,500 BTU LP/Propane
(3.5 kW Nat./3.4 kW LP/Propane)
10,000 BTU Nat./9,500 BTU LP/Propane
(2.5 kW Nat./2.4 LP/Propane)
16,000 BTU Nat!1 5,500 BTU LP/Propane
(4.7 kW Nat./4.5 kW LP/Propane)
8,000 BTU Nat./7,500 BTU LP/Propane
(2.0 kW Nat./1.9 kW LP/Propane)
6,000 BTU Nat./5,500 kW LP/Propane
(1.5 kW Nat./1.4 kW LP/Propane)
150 Ib.(67.Skg)
8,000 BTU Nat./7,500 BTU LP/Propane
(2.0 kW Nat./1.9 kW LP/Propane)
6,000 BTU Nat./5,500 BTU LP/Propane
(1.5 kW Nat./1.4 kW LP/Propane)
125 Ibs. (56.3 kg)
MINIMUM CLEARANCES
Minimum clearances from the product to adjacent surfaces or construction:
• Below 36" (91.4 cm)
Sides - 0"
Rear - 0"
• Above 36" (91.4 cm)
Sides - 6" (15.2 cm)
Within the 6" (15.2 cm) side clearance, wall cabinets shall be no deeper than 13" (33.0 cm) and must be a
minimum of 18" (45.7 cm) above the countertop.
Rear - 0" with backguard or high shelf
0" with island trim and non-combustible heat resistant rear wall
6" (15.2 cm) with island trim and combustible rear wall
• Wall cabinets directly above the product must be minimum of 36" (91.4 cm) above the countertop for open top
burners and 42" (106.7 cm) for sealed burners.
To maintain product warranty, the responsibility for ensuring the use of non-combustible heat resistant materials when
required, lies with individual owner, contractor or end user.
*It is not recommended to install two or more units side by side.
3 4