Viking DGRT series Installation Manual

Viking Installation Guide
Built-In Gas Rangetops
IMPORTANT - PLEASE READ AND FOLLOW
Before beginning, please read these instructions completely and carefully.
Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.
Please obseve all local and national codes and ordinances.
Please ensure that this product is properly grounded.
The installer should leave these instructions with the consumer who should retain for local inspector's use and
for future reference.
Installation must conform with national and local codes or in the absence of codes, the National Fuel Gas Code, ANSI Z223.-latest edition. Electrical installation must be in accordance with National Electrical Code, ANSI/NFPA 70 and/or local codes. IN CANADA: Installation must be in accordance with the current CAN/CGA B149.1 & 2 Gas Installation codes and/or local codes. Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part 1 and/or local codes.
Installation of any gas-fired equipment should be made by a licensed plumber. A manual gas shut-off valve must be installed in the gas supply line ahead of the oven in the gas stream for safety and ease of service.
In Massachusetts: All gas products must be installed by a "Massachusetts" licensed plumber or gasfitter. A "T" handle type manual gas valve must be installed in the gas supply line to the appliance.
ELECTRICAL GROUNDING
INSTRUCTIONS
This rangetop must be electrically grounded in accordance with local codes. This appliance is equipped with a three-prong plug for your protection against shock hazard and should be plugged directly into a properly grounded reeptacle. Do not cut or remove the grounding prong from this plug.
FOR PERSONAL SAFETY, THIS APPLIANCE
MUST BE PROPERLY GROUNDED.
IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY,
OR DEATH.
1. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
2. WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor's phone.
Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
3. Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
If not installed, operated and maintained in accordance with the manufacturer's instructions,
this product could expose you to substances in fuel or from fuel combustion which can cause death or
serious illness and which are known to cause cancer, birth defects, or other reproductive harm.
For example, benzene is a chemical which is part of the gas supplied to the cooking product. It is consumed in the flame during combustion. However exposure to a small amount of benzene is possible if a gas leak occurs. Formaldehyde and soot are by-products of incomplete combustion. Properly adjusted burners with a bluish rather than yellow flame will minimize incomplete combustion.
Basic Specifications
VGRT Models
Description Overall width
Overall height
Overall depth from rear
Cutout width
24" W. Models 23 718" (60.6 cm)
To top of spider grate - To top of burner grate - To top of island trim - To top of 6" backguard- To top of high shelf -
24" (61.0 cm)
30" W. Models 29 7/8" (75.8 cm)
9 1/4" (23.5 cm) (Open top Burners only) 9 1/8" (23.2 cm) (Sealed Burners only)
8 7/8" (22.5 cm) 13 7/8" (35.2 cm) 31 3/8" (79.7 cm)
To end of side panel - 24" (61.0 cm) To end of control panel - 25 3/4" (65.4 cm) To end of knobs - 27 3/4" (70.5 cm)
30" (76.2 cm)
Cutout Height Open top Burners - 7 1/2" (19.1 cm) Top of grate support should be 3/8" (1.0cm) above countertop.
Sealed Burners - 7 5/8" (19.4 cm) Top ot: grate support should be 3/8" (1 .O cm) above countertop.
Minimum 24" (61.0 cm) Maximum 25 3/4" (65.4 cm)
120 VAC/60 Hz 4ft. (121.9 cm), 3-wire cord with grounded 3-prong plug
Cutout Depth Electrical
requirements Gas requirements Shipped natural or LP/Propane gas ; field convertible with conversion kit (purchased separately);
accepts standard residential 1/2" (1.3 cm) ID gas service line Maximum amp .3 amps .3 amps usage Surface burner 15.000 BTU Nat./13,500 BTU LP/Propane rating (4.4 kW Nat./4.0 kW LP/Propane) Approximate 100 Ibs. 125 Ibs. Shipping Wt. (45.0 kg) (56.3 kg)
MINIMUM CLEARANCES
Minimum clearances from the product to adjacent surfaces or construction:
Below 36" (91.4 cm) Sides - 0"
Rear - 0"
Above 36" (91.4 cm) Sides - 6" (15.2 cm) Within the 6" (15.2 cm) side clearance, wall cabinets shall be no deeper than 13" (33.0 cm) and must be a minimum of 18" (45.7 cm) above the countertop. Rear - 0" with backguard or high shelf
O" with island trim and non-combustible heat resistant rear wall 6" (15.2 cm) with island trim and combustible rear wall
Wall cabinets directly above the product must be minimum of 36" (91.4 cm) above the countertop for open top
burners and 42" (106.7 cm) for sealed burners.
To maintain product warranty, the responsibility for ensuring the use of non-combustible heat resistant materials when required, lies with individual owner, contractor or end user.
*it is not recommended to install two or more units side by side.
1 2
Basic Specifications - VGRT Models
Description 36" W. Models 42" W. Models
Overall width Overall height
Overall depth from _ear
Cutout width Cutout Height
Cutout Depth Electrical
_equirements Gas requirements
35 7/8" (91.1 cm) 42" (106.7 cm) To top of spider grate - 9 1/4" (23.5 cm) To top of burner grate - 9 1/8" (23.2 cm) To top of island trim - 8 7/8" (22.5 cm) To top of 6" backguard- 13 7/8" (35.2 cm) To top of high shelf -
48" W. Models 60" W. Models
47 7/8" (121.6 cm) 59 1/2" (151.1cm)
(Open top Burners only) (Sealed Burners only)
31 3/8" (79.7 cm) To end of side panel - 24" (61.0 cm) To end of control panel - 25 3/4" (65.4 cm)
To end of knobs - 27 3/4" (70.5 cm)
36" (91.4 cm) 42 1/8" (107 cm) 48" (121.9 cm) 59 5/8" (151.4 cm) Open top Burners - 7 1/2" (19.1 cm) (top of grate support should be 3/8" [1.0 cm] above countertop.
Sealed Burners - 7 5/8" (19.4 cm) (top of side trim should be 3/8" [1.0 cm] above countertop.
Minimum 24" (61.0 cm) Maximum 25 3/4" (65.4 cm)
120 VAC/60 Hz 4ft. (121.9 cm), 3-wire cord with grounded 3-prong plug
Shipped natural or LP/Propane gas; field convertible with conversion kit (purchases separately); accepts standard residential 1/2" (1.3 cm) ID gas service line
Maximum amp usage
6B - .6amps 4G - 3.9amps 4Q - .6amps
6G - 4.2 amps
6Q - .6 amps
4G - 7.2 amps
4GQ- 4.2 amps
4K - .6 amps
4Q - .6 amps
Surface burner _ating
_Vok Burner _ating (if applicable)
Griddle burner _ating
BTU LP Grill burner _atJng Approximate Shipping Wt.
6G - 7.8 amps 6GQ- 4.2 amps
15.000 BTU Nat./13,500 BTU LP/Propane (4.4 kW Nat./4.0 kW LP/Pro)ane)
N/A 27,800 BTU Nat./LP N/A
(8.2 kW Nat./LP
12"/18" Wide
15,000 BTU Nat./13,500 BTU LP
(4.4 kW / 4.0 kW ) 12" Wide - 1 @ 18,000 BTU Nat. (5.3 kW)/16,000 BTU LP/Propane (4.7 kW) 24" Wide - 2 @ 15,000 BTU Nat. (4.4 KW) / 13,500 BTU LP/Propane (4.0 kW)
6B-150 Ib.(67.Skg) 6G -203 Ib.(91.4kg) 6G - 2561b.(115.2kg) 4G - 160 Ib.(72.0kg) 6Q -198 Ib.(89.1kg) 6GQ-251 Ib.(113.0kg) 4Q - 155 Ib.(69.8 kg) 4G - 213 Ib.(95.6kg)
4GQ-208 Ib.(93.6 kg) 4K - 213 Ib.(95.6 kg) 4Q - 198 Ib.(89.1 kg)
24" Wide Two 15,000 BTU Nat./13,500
(4.4 kW / 4.0 kW)
MINIMUM CLEARANCES
Minimum clearances from the product to adjacent surfaces or construction:
Below 36" (91.4 cm) Sides- 0"
Rear- 0"
Above 36" (91.4 cm) Sides- 6" (15.2 cm)
Within the 6" (15.2 cm) side clearance, wall cabinets shall be no deeper than 13" (33.0 cm) and must be a minimum of 18"
(45.7 cm) above the countertop.
Rear - 0" with backguard or high shelf
0" with island trim and non-combustible heat resistant rear wall B" (15.2 cm) with island trim and combustible rear wall
Wall cabinets directly above the product must be minimum of 36" (91.4 cm) above the countertop for open top burners and 42"
(108.7 cm) for sealed burners.
To maintain product warranty, the responsibility for ensuring the use of non-combustible heat resistant materials when required, lies with individual owner, contractor or end user.
*it is not recommended to install two or more units side by side.
Basic Specifications - DGRT Models
Description Overall width
Overall height
Overall depth from rear
Cutout width Cutout Height
Cutout Depth Electrical
requirements Gas requirements
Maximum amp usage Surface burner rating
left front
left rear
center
right rear
right front
Approximate Shipping Wt.
30" W. Models
29 7/8" (759. cm) To top of grate - 6 1/8" (15.6'cm) To top of island trim - 6 1/8" (15.6 cm) To top of 6" backguard- 12 1/8" (30.8 cm) To top of high shelf - 24 1/8" (61.3 cm)
To end of side panel - 24 1/2" (62.2 cm)
To end of control panel - 26 1/8" (66.4 cm)
To end of knobs - 27 5/8" (70.5 cm)
30" (76.2 cm) 36" (91.4 cm) 5 3/4" (14.6 cm) (top of grates should be 3/8" [1.0 cm] above countertop.
36" W. Models 35 7/8" (91.1 cm)
24 1/2" (62.2 cm)
120 VAC/60 Hz 4ft. (121.9 cm), 3-wire cord with grounded 3-prong plug
Shipped natural or LP/Propane gas ; field convertible with conversion kit (purchased separately); accepts standard residential 1/2" (1.3 cm)ID gas service line
2.0 amps 2.0 amps
16,000 BTU Nat./15,500 BTU LP/Propane (4.7 kW Nat./4.5 kW LP/Propane) 12,000 BTU Nat./11,500 BTU LP/Propane (3.5 kW Nat./3.4 kW LP/Propane) N/A
12,000 BTU Nat./11,500 BTU LP/Propane (3.5 kW Nat./3.4 kW LP/Propane) 10,000 BTU Nat./9,500 BTU LP/Propane (2.5 kW Nat./2.4 LP/Propane) 16,000 BTU Nat!1 5,500 BTU LP/Propane (4.7 kW Nat./4.5 kW LP/Propane) 8,000 BTU Nat./7,500 BTU LP/Propane (2.0 kW Nat./1.9 kW LP/Propane) 6,000 BTU Nat./5,500 kW LP/Propane (1.5 kW Nat./1.4 kW LP/Propane)
150 Ib.(67.Skg)
8,000 BTU Nat./7,500 BTU LP/Propane (2.0 kW Nat./1.9 kW LP/Propane) 6,000 BTU Nat./5,500 BTU LP/Propane (1.5 kW Nat./1.4 kW LP/Propane)
125 Ibs. (56.3 kg)
MINIMUM CLEARANCES
Minimum clearances from the product to adjacent surfaces or construction:
Below 36" (91.4 cm) Sides - 0" Rear - 0"
Above 36" (91.4 cm) Sides - 6" (15.2 cm)
Within the 6" (15.2 cm) side clearance, wall cabinets shall be no deeper than 13" (33.0 cm) and must be a minimum of 18" (45.7 cm) above the countertop. Rear - 0" with backguard or high shelf
0" with island trim and non-combustible heat resistant rear wall 6" (15.2 cm) with island trim and combustible rear wall
Wall cabinets directly above the product must be minimum of 36" (91.4 cm) above the countertop for open top
burners and 42" (106.7 cm) for sealed burners.
To maintain product warranty, the responsibility for ensuring the use of non-combustible heat resistant materials when required, lies with individual owner, contractor or end user.
*It is not recommended to install two or more units side by side.
3 4