Viking DGRT300-4B Installation Manual

F1239Q EN
(030608J)
Viking Range Corporation
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information,
or visit the Viking web site at
vikingrange.com
Viking Installation Guide
Built-In Gas Rangetops
1
IMPORTANT - PLEASE READ AND FOLLOW
•Before beginning, please read these instructions completely and carefully.
•Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.
•Please obseve all local and national codes and ordinances.
•Please ensure that this product is properly grounded.
•The installer should leave these instructions with the con­sumer who should retain for local inspector’s use and for fu­ture reference.
Installation must conform with national and local codes or in the absence of codes, the National Fuel Gas Code, ANSI Z223.-latest edition. Electrical installation must be in accor­dance with National Electrical Code, ANSI/NFPA 70 and/or local codes. IN CANADA: Installation must be in accor­dance with the current CAN/CGA B149.1 & 2 Gas Installation codes and/or local codes. Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part 1 and/or local codes.
Installation of any gas-fired equipment should be made by a licensed plumber. A manual gas shut-off valve must be in­stalled in the gas supply line ahead of the oven in the gas stream for safety and ease of service.
In Massachusetts: All gas products must be installed by a “Massachusetts” licensed plumber or gasfitter. A “T” handle type manual gas valve must be installed in the gas supply line to the appliance.
1. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
2. WHAT TO DO IF YOU SMELL GAS:
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use
any phone in your building.
•Immediately call your gas supplier from a
neighbor’s phone.
•Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the
fire department.
3. Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
ELECTRICAL GROUNDING
INSTRUCTIONS
This rangetop must be electrically grounded in ac­cordance with local codes. This appliance is equipped with a three-prong plug for your protection against shock hazard and should be plugged directly into a properly grounded reeptacle. Do not cut or remove the grounding prong from this plug.
FOR PERSONAL SAFETY, THIS APPLIANCE
MUST BE PROPERLY GROUNDED.
W A R N I N G
IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY,
OR DEATH.
W A R N I N G
W A R N I N G
If not installed, operated and maintained in accor­dance with the manufacturer’s instructions, this prod­uct could expose you to substances in fuel or from fuel combustion which can cause death or serious ill­ness and which are known to cause cancer, birth de­fects, or other reproductive harm.
For example, benzene is a chemical which is part of the gas supplied to the cooking product. It is con­sumed in the flame during combustion. However ex­posure to a small amount of benzene is possible if a gas leak occurs. Formaldehyde and soot are by­products of incomplete combustion. Properly ad­justed burners with a bluish rather than yellow flame will minimize incomplete combustion.
2
Basic Specifications
Description 24” W. Models 30” W. Models
Overall width 23 7/8” (60.6 cm) 29 7/8” (75.8 cm) Overall height To top of spider grate - 9 1/4” (23.5 cm) (Open top Burners only)
To top of burner grate - 9 1/8” (23.2 cm) (Sealed Burners only) To top of island trim - 8 7/8” (22.5 cm) To top of 6” backguard- 13 7/8” (35.2 cm) To top of high shelf - 31 3/8” (79.7 cm)
Overall depth from To end of side panel - 24” (61.0 cm)
rear To end of control panel - 25 3/4” (65.4 cm)
To end of knobs - 27 3/4” (70.5 cm)
Cutout width 24” (61.0 cm) 30” (76.2 cm) Cutout Height Open top Burners - 7 1/2” (19.1 cm) Top of grate support should be 3/8” (1.0 cm) above countertop.
Sealed Burners - 7 5/8” (19.4 cm) Top of grate support should be 3/8” (1.0 cm) above countertop. Cutout Depth Minimum 24” (61.0 cm) Maximum 25 3/4” (65.4 cm) Electrical 120 VAC/60 Hz 4ft. (121.9 cm), 3-wire cord with grounded 3-prong plug requirements Gas requirements Shipped natural or LP/Propane gas ; field convertible with conversion kit (purchased separately);
accepts standard residential 1/2” (1.3 cm) ID gas service line Maximum amp .3 amps .3 amps usage Surface burner 15.000 BTU Nat./13,500 BTU LP/Propane rating (4.4 kW Nat./4.0 kW LP/Propane) Approximate 100 lbs. 125 lbs. Shipping Wt. (45.0 kg) (56.3 kg)
VGRT Models
MINIMUM CLEARANCES
Minimum clearances from the product to adjacent surfaces or construction:
• Below 36” (91.4 cm) Sides - 0” Rear - 0”
• Above 36” (91.4 cm) Sides - 6” (15.2 cm) Within the 6” (15.2 cm) side clearance, wall cabinets shall be no deeper than 13” (33.0 cm) and must be a minimum of 18” (45.7 cm) above the countertop. Rear - 0” with backguard or high shelf
0” with island trim and non-combustible heat resistant rear wall
6” (15.2 cm) with island trim and combustible rear wall
• Wall cabinets directly above the product must be minimum of 36” (91.4 cm) above the countertop for open top
burners and 42” (106.7 cm) for sealed burners.
To maintain product warranty, the responsibility for ensuring the use of non-combustible heat resistant materials when re­quired, lies with individual owner, contractor or end user.
*It is not recommended to install two or more units side by side.
Description 36” W. Models 42” W. Models 48” W. Models 60” W. Models
Overall width 35 7/8” (91.1 cm) 42” (106.7 cm) 47 7/8” (121.6 cm) 59 1/2” (151.1cm) Overall height To top of spider grate - 9 1/4” (23.5 cm) (Open top Burners only)
To top of burner grate - 9 1/8” (23.2 cm) (Sealed Burners only) To top of island trim - 8 7/8” (22.5 cm) To top of 6” backguard- 13 7/8” (35.2 cm) To top of high shelf - 31 3/8” (79.7 cm)
Overall depth from To end of side panel - 24” (61.0 cm)
rear To end of control panel - 25 3/4” (65.4 cm)
To end of knobs - 27 3/4” (70.5 cm)
Cutout width 36” (91.4 cm) 42 1/8” (107 cm) 48” (121.9 cm) 59 5/8” (151.4 cm) Cutout Height Open top Burners - 7 1/2” (19.1 cm) (top of grate support should be 3/8” [1.0 cm] above countertop.
Sealed Burners - 7 5/8” (19.4 cm) (top of side trim should be 3/8” [1.0 cm] above countertop. Cutout Depth Minimum 24” (61.0 cm) Maximum 25 3/4” (65.4 cm) Electrical 120 VAC/60 Hz 4ft. (121.9 cm), 3-wire cord with grounded 3-prong plug requirements Gas requirements Shipped natural or LP/Propane gas; field convertible with conversion kit (purchases separately);
accepts standard residential 1/2” (1.3 cm) ID gas service line Maximum amp 6B - .6 amps 6G - 4.2 amps 6G - 7.8 amps usage 4G - 3.9 amps 6Q - .6 amps 6GQ- 4.2 amps
4Q - .6 amps 4G - 7.2 amps
4GQ- 4.2 amps 4K - .6 amps
4Q - .6 amps Surface burner 15.000 BTU Nat./13,500 BTU LP/Propane rating (4.4 kW Nat./4.0 kW LP/Propane) Wok Burner N/A 27,500 BTU Nat./LP N/A rating (If applicable) (8.2 kW Nat./LP Griddle burner 12”/18” Wide 24” Wide
rating 15,000 BTU Nat./13,500 BTU LPTwo 15,000 BTU Nat./13,500 BTU LP (4.4 kW / 4.0 kW ) (4.4 kW / 4.0 kW)
Grill burner 12” Wide - 1 @ 18,000 BTU Nat. (5.3 kW)/ 16,000 BTU LP/Propane (4.7 kW)
rating 24” Wide - 2 @ 15,000 BTU Nat. (4.4 KW) / 13,500 BTU LP/Propane (4.0 kW)
Approximate 6B-150 lb.(67.5kg) 6G -203 lb.(91.4kg) 6G - 256lb.(115.2kg)
Shipping Wt. 4G - 160 lb.(72.0kg) 6Q -198 lb.(89.1kg) 6GQ-251 lb.(113.0kg)
4Q - 155 lb.(69.8 kg) 4G - 213 lb.(95.6kg)
4GQ-208 lb.(93.6 kg)
4K - 213 lb.(95.6 kg)
4Q - 198 lb.(89.1 kg)
3
MINIMUM CLEARANCES
Minimum clearances from the product to adjacent surfaces or construction:
• Below 36” (91.4 cm) Sides - 0” Rear - 0”
• Above 36” (91.4 cm) Sides - 6” (15.2 cm) Within the 6” (15.2 cm) side clearance, wall cabinets shall be no deeper than 13” (33.0 cm) and must be a minimum of 18” (45.7 cm) above the countertop. Rear - 0” with backguard or high shelf
0” with island trim and non-combustible heat resistant rear wall 6” (15.2 cm) with island trim and combustible rear wall
• Wall cabinets directly above the product must be minimum of 36” (91.4 cm) above the countertop for open top burners and 42”
(106.7 cm) for sealed burners.
To maintain product warranty, the responsibility for ensuring the use of non-combustible heat resistant materials when required, lies with individual owner, contractor or end user.
*It is not recommended to install two or more units side by side.
Basic Specifications -
VGRT Models
4
Basic Specifications - DGRT Models
Description 30” W. Models 36” W. Models
Overall width 29 7/8” (759. cm) 35 7/8” (91.1 cm) Overall height To top of grate - 6 1/8” (15.6 cm)
To top of island trim - 6 1/8” (15.6 cm) To top of 6” backguard- 12 1/8” (30.8 cm) To top of high shelf - 24 1/8” (61.3 cm)
Overall depth from To end of side panel - 24 1/2” (62.2 cm)
rear To end of control panel - 26 1/8” (66.4 cm)
To end of knobs - 27 5/8” (70.5 cm)
Cutout width 30” (76.2 cm) 36” (91.4 cm) Cutout Height 5 3/4” (14.6 cm) (top of grates should be 3/8” [1.0 cm] above countertop.
Cutout Depth 24 1/2” (62.2 cm) Electrical 120 VAC/60 Hz 4ft. (121.9 cm), 3-wire cord with grounded 3-prong plug requirements Gas requirements Shipped natural or LP/Propane gas ; field convertible with conversion kit (purchased separately);
accepts standard residential 1/2” (1.3 cm) ID gas service line Maximum amp 2.0 amps 2.0 amps usage Surface burner rating
left front 16,000 BTU Nat./15,500 BTU LP/Propane 12,000 BTU Nat./11,500 BTU LP/Propane
(4.7 kW Nat./4.5 kW LP/Propane) (3.5 kW Nat./3.4 kW LP/Propane)
left rear 12,000 BTU Nat./11,500 BTU LP/Propane 10,000 BTU Nat./9,500 BTU LP/Propane
(3.5 kW Nat./3.4 kW LP/Propane) (2.5 kW Nat./2.4 LP/Propane)
center N/A 16,000 BTU Nat/15,500 BTU LP/Propane
(4.7 kW Nat./4.5 kW LP/Propane)
right rear 8,000 BTU Nat./7,500 BTU LP/Propane 8,000 BTU Nat./7,500 BTU LP/Propane
(2.0 kW Nat./1.9 kW LP/Propane) (2.0 kW Nat./1.9 kW LP/Propane)
right front 6,000 BTU Nat./5,500 BTU LP/Propane 6,000 BTU Nat./5,500 kW LP/Propane
(1.5 kW Nat./1.4 kW LP/Propane) (1.5 kW Nat./1.4 kW LP/Propane) Approximate 125 lbs. (56.3 kg) 150 lb.(67.5kg)
Shipping Wt.
MINIMUM CLEARANCES
Minimum clearances from the product to adjacent surfaces or construction:
• Below 36” (91.4 cm) Sides - 0” Rear - 0”
• Above 36” (91.4 cm) Sides - 6” (15.2 cm) Within the 6” (15.2 cm) side clearance, wall cabinets shall be no deeper than 13” (33.0 cm) and must be a mini­mum of 18” (45.7 cm) above the countertop. Rear - 0” with backguard or high shelf
0” with island trim and non-combustible heat resistant rear wall
6” (15.2 cm) with island trim and combustible rear wall
• Wall cabinets directly above the product must be minimum of 36” (91.4 cm) above the countertop for open top
burners and 42” (106.7 cm) for sealed burners.
To maintain product warranty, the responsibility for ensuring the use of non-combustible heat resistant materials when re­quired, lies with individual owner, contractor or end user.
*It is not recommended to install two or more units side by side.