Viking Designer DGCU165, DGCU105, DGCU155, DGSU100, DGSU160 Specifications

...
2
DESCRIPTION DGCU105 (30” W.) DGCU165 (36” W.) DGCU155 (45” w.)
Cutout Width - Minimum 28 3/4” (73.0 cm) 34 1/2” (87.6 cm) 42 7/8” (108.9 cm)
Maximum 29 7/8” (75.9 cm) 35 7/8” (91.1 cm) 44 1/8” (112.1 cm) Cutout Height - Minimum 2 3/4” (7.0 cm) Cutout Depth - Minimum 19 11/16” (50.0 cm)
Maximum 20 1/2” (52.1cm) Overall Width 30 3/4” (78.1 cm) 36 3/4” (93.3 cm) 45” (114.3 cm) Overall Height from Bottom (including connector) 4 1/4” (10.8 cm) Overall Depth from Rear 21” (53.3 cm) Gas Requirements Not field convertible - Must be ordered from factory either natural or LP/Propane.
Uses
standard residential 1/2” (1.3 cm) I.D. gas service line.
Electrical Requirements 120 VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product. Maximum Amp Usage 2.0 amps Surface Burner Rating
Left Front- 14,000 Nat./13,500 LP (BTU) 12,000 Nat./11,500 LP (BTU) 12,000 Nat./11,500 LP (BTU)
(4.1 Nat./4.0 LP [kw]) (3.5 Nat./2.8 LP [kw]) (3.5 Nat./2.8 LP [kw])
Left Rear- 12,000 Nat./11,500 LP (BTU) 10,000 Nat./LP (BTU) 8,000 Nat./LP (BTU)
(3.5 Nat./2.8 LP [kw]) (2.9 Nat./LP [kw]) (2.1 Nat./LP [kw])
Left Center N/A 14,000 Nat./13,500 LP (BTU) 10,000 Nat./LP (BTU)
(4.1 Nat./4.0 LP [kw]) (2.9 Nat./LP [kw])
Right Center N/A N/A 14,000 Nat./13,500 LP (BTU)
(4.1 Nat./4.0 LP [kw])
Right Rear- 8,000 Nat./LP (BTU) 8,000 Nat./LP (BTU) 6,000 Nat./LP (BTU)
(2.1 Nat./LP [kw]) (2.1 Nat./LP [kw]) (1.8 Nat./LP [kw])
Right Front- 6,000 Nat./LP (BTU) 6,000 Nat./LP (BTU) 8,000 Nat./LP (BTU)
(1.8 Nat./LP [kw]) (1.8 Nat./LP [kw]) (2.1 Nat./LP [kw])
Approximate Shipping Weight 67 lb. (30.2 kg.) 80 lb. (36.0 kg) 93 lb. (41.9 kg)
DESCRIPTION VGSU102 (30” W.) VGSU162 (36” W.)
Cutout Width - Minimum 26 7/8” (68.3 cm) 34 3/8” (87.3 cm)
Maximum 29 7/8” (75.9 cm) 35 7/8” (91.1 cm) Cutout Height - Minimum 2 1/2” (6.4 cm) Cutout Depth - Minimum 18 5/8” (47.3 cm)
Maximum 20 1/8” (51.1cm) Overall Width 30 3/4” (78.1 cm) 36 3/4” (93.3 cm) Overall Height from Bottom 5” (12.7 cm) Overall Depth from Rear 21” (53.3 cm) Gas Requirements To field convert from natural or LP/Propane, the orifice spuds and regulator must be physically
changed. Order conversion kit NK2VGSU to convert to natural and LPK3VGSU to convert to LP.
Uses standard residential 1/2” (1.3 cm) I.D. gas service line.
Electrical Requirements 120 VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product. Maximum Amp Usage 2.0 amps Surface Burner Rating
Left Front- 16,000 Nat./15,500 LP (BTU) 16,000 Nat./15,500 LP (BTU)
(4.8 Nat./4.65 LP [kw]) (4.8 Nat./4.65 LP [kw])
Left Rear- 12,000 Nat./11,500 LP (BTU) 12,000 Nat./11,500 LP (BTU)
(3.6 Nat./3.45 LP [kw]) (3.6 Nat./3.45 LP [kw])
Center Front/Rear N/A 12,000 Nat./11,500 LP (BTU)
(3.6 Nat./3.45 LP [kw])
Right Rear- 8,000 Nat./7,500 LP (BTU) 8,000 Nat./7,500 LP (BTU)
(2.4 Nat./2.25 LP [kw]) (2.4 Nat./2.25 LP [kw])
Right Front- 6,000 Nat./5,500 LP (BTU) 6,000 Nat./5,500 LP (BTU)
(1.8 Nat./1.65 LP [kw]) (1.8 Nat./1.65 LP [kw])
Approximate Shipping Weight 67 lb. (30.2 kg.) 80 lb. (36.0 kg)
BASIC SPECIFICATIONS
3
GENERAL INFORMATION
1. WARNING
::
The use of cabinets for storage above the appliance may result in a potential burn hazard. Combustible items may ignite, metallic items may become hot and cause burns. If a cabinet storage is to be provided the risk can be reduced by installing a rangehood that projects horizontally a minimum of 5” (12.7 cm) beyond the bottom of the cabinets.
2. WARNING
::
This appliance shall not be used for space heating. This information is based on safety considerations.
3. All openings in the wall behind the appliance and in the floor under the appliance shall be sealed.
4. Keep appliance area clear and free from combustible materials, gasoline, and other flammable vapors.
5. Do not obstruct the flow of combustion and ventilation air.
6. Disconnect the electrical supply to the appliance before servicing.
7. When removing cooktop for cleaning and/or service; A. Shut off gas at main supply B. Disconnect AC power supply C. Disconnect gas line to the inlet pipe. D. Lift appliance out of cabinet cutout.
8. Electrical Requirement Normal grounded household current, 120 volts, 60 Hz, 15 amps, single phase. Electrical installation should comply with national and local codes.
9.
Air Supply and Ventilation
Means must be provided for any heavy-duty cooking appliance to exhaust combustion waste product to the outside of the building. It is recommended that the cooktop be set under a powered, vented exhaust hood, or non-vented recirculating hood. Nothing should obstruct the flow of combustion and ventilation air.
10. Gas Manifold Pressure
Natural gas - 5.0” W.C.P. LP/Propane - 10.0” W.C.P.
11. Flexible Connections
If the unit is to be installed with flexible couplings and/or quick disconnect fittings, the installer must use a flexible connector of at least 1/2” I.D. (1.3 cm) NPT with suitable strain reliefs and comply with ANSI Z21.41 and Z21.69 standards.
DESCRIPTION DGSU100 (30” W.) DGSU160 (36” W.)
Cutout Width - Minimum 29 1/8” (74.0 cm) 34 7/8” (88.6 cm)
Maximum 29 7/8” (75.9 cm) 35 7/8” (91.1 cm) Cutout Height - Minimum 3 1/8” (7.9 cm) Cutout Depth - Minimum 19 3/4” (50.2 cm)
Maximum 20 1/8” (51.1cm) Overall Width 30 3/4” (78.1 cm) 36 3/4” (93.3 cm) Overall Height from Bottom 4 3/8” (10.5 cm) Overall Depth from Rear 21” (53.3 cm) Gas Requirements To field convert from natural or LP/Propane, the orifice spuds and regulator must be physically
changed. Order conversion kit DLPK to convert to LP.
Uses standard residential 1/2” (1.3
cm) I.D. gas service line.
Electrical Requirements 120 VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product. Maximum Amp Usage 2.0 amps Surface Burner Rating
Left Front- 14,000 Nat./13,500 LP (BTU) 12,000 Nat./11,500 LP (BTU)
(4.1 Nat./4.0 LP [kw]) (3.5 Nat./2.8 LP [kw])
Left Rear- 12,000 Nat./11,500 LP (BTU) 10,000 Nat./LP (BTU)
(3.5 Nat./2.8 LP [kw]) (2.9 Nat./LP [kw])
Center Front/Rear N/A 14,000 Nat./13,500 LP (BTU)
(4.1 Nat./4.0 LP [kw])
Right Rear- 8,000 Nat./LP (BTU) 8,000 Nat./LP (BTU)
(2.1 Nat./LP [kw]) (2.1 Nat./LP [kw])
Right Front- 6,000 Nat./LP (BTU) 6,000 Nat./LP (BTU)
(1.8 Nat./LP [kw]) (1.8 Nat./LP [kw])
Approximate Shipping Weight 49 lb. (22.0 kg.) 74 lb. (33.3 kg)
+ 4 hidden pages