•Before beginning, please read these instructions completely and carefully.
•Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.
•Please observe all local and national codes and ordinances.
•Please ensure that this product is properly grounded.
•The installer should leave these instructions with the consumer who should retain for local inspector’s use and for
future reference.
•Installation must conform with local codes or, in the absence of codes, the National Electrical Code, ANSI/NFPA 70latest edition.
IN CANADA: Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part 1
and/or local codes.
GENERAL INFORMATION
ARNING:
W
1.
items may ignite, metallic items may become hot and cause burns. If a cabinet storage is to provided the risk can
be reduced by installing a range hood that projects horizontally a minimum of 5 in. beyond the bottom of the
cabinets.
ARNING:
W
2.
3. All openings in the wall behind the appliance in the floor under the appliance shall be sealed.
4. Keep appliance area clear and free from combustible materials, gasoline, and other flammable vapors.
5. Disconnect the electric supply to the appliance before cleaning or servicing.
6. When removing the cooktop for service and/or cleaning, disconnect AC power supply.
7. Electrical Requirement:
Listed on Specifications/Wiring Diagram Sheet - Minimum Recommended Electric Circuit.
The use of cabinets for storage above the appliance may result in potential burn hazard. Combustible
This appliance shall not be used for space heating. This information is based on safety considerations.
WARNING!
ELECTRICAL GROUNDING
INSTRUCTIONS
This cooktop must be electrically grounded in
accordance with local codes or, in the absence of
codes, with the National Electrical Code,
ANSI/NFPA 70-latest edition.
Electrical Requirements240 - 208/120 VAC/60 Hz - 3-wire conduit with a No. 10 ground wire.
40 amp connection60 amp connection
Maximum Amp Usage240V8.4 kW; 35.0 amps11.8 kW49.2 amps
208V 6.3 kW; 30.3 amps8.9 kW42.6 amps
40V208V240V208V
Surface Element Rating
Right Front1500 1125 watts1200 900 watts
Right Rear25001875 watts25001875 watts
Center FrontN/AN/A18001350
Bridge800600 watts800600 watts
Center RearN/AN/A18001350
Left Front18001350 watts22001650 watts
Left Rear18001350 watts15001125 watts
Approximate Shipping Weight 52 lb. (23.4 kg)63 lb. (28.4 kg)
2
SPECIFICATIONS - DECU ELECTRIC COOKTOP
DescriptionDECU106 30” W. DECU166 36” W. DECU155 45” W.
Check your local codes regarding this unit. This cooktop is supplied with a 3-wire, A.C. 208/120 volt or 120/240 volt,
60 HZ electrical system. A white (neutral) is not needed for this unit. See next section for grounding instructions. It
AUTION:
should be fused separately.
the cooktop is installed and ready to operate. The junction box should be connected to a suitable ground. Do not use
a GFI circuit.
Refer to the sepcifications chart and the identification label on the bottom of the burner box for kilowatt rating and
recommended amperage. House wiring and fusing must comply with local codes. If no local codes are applicable,
wire in accordance with the National Electrical Code, ANSI/NFPA 70-latest edition.
C
Be sure the electric power is off from the breaker box to the junction box until
ELECTRICAL CONNECTION
WARNING:
to do so could result in serious injury or death.
When making the wire connections, use the entire length of the conduit provided (3 feet). The conduit must not be
cut. Connect the red and black leads from the unit conduit to the corresonding leads in the junction box. The green
ground wire in the conduit is connected to the unit frame. When connecting to a 3-conductor branch circuit, if local
codes permit, connect the green ground connector lead of the unit to the branch circuit neutral (gray or white in color).
The electrical power to the unit must be shut off while line connections are being made. Failure
WARNING!
DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE. SUCH USE MAY
RESULT IN A FIRE, ELECTRICAL SHOCK OR OTHER PERSONAL INJURY.
3
PROXIMITY TO SIDE CABINET INSTALLATION
1. The cooktop may be installed directly to existing base cabinets.
2. The cooktop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical
surfaces above 36” (91.4 cm) high. There must be a minimum of 6” (15.2 cm) side clearance from the cooktop to
such combustible surfaces above the 36” (91.4 cm).
3. Within the 6” (15.2 cm) side clearance to combustible vertical surfaces above 36” (91.4 cm), the maximum wall
cabinet depth must be 13” (33.0 cm) and wall cabinets within this 6” (15.2 cm) side clearance must be 18” (45.7 cm)
above the 36” (91.4 cm) high countertop.
4. Wall cabinet above the cooktop must be a minimum of 36” (91.4 cm) above the countertop for a full width of the
cooktop. This minimum height requirement does not
apply if a rangehood is installed over the cooking surface.
NOTE: Refer to Installation of Hold Down Brackets on page 7 for minimum clearances under counter.
36” Min.
(91.4 cm)
MINIMUM CLEARANCES FROM ADJACENT
COMBUSTIBLE CONSTRUCTION
•Above countertop (above 36” [91.4 cm])
•Side 6” (15.2 cm)
•Rear 0” (0 cm)
•Within 8” side clearance. Wall cabinets no deeper
than 13” (33.0 cm)
•Must be minimum 18” (45.7 cm) above countertop
•Wall cabinets directly above the product must be
minimum 36” (91.4 cm) above the countertop.
13” Max
(33.0 cm)
6” Min.(15.2 cm)
36” Min.
(91.4 cm)
18” Min.
(45.7 cm)
0” Min.
(0 cm)
3 1/8”
(7.9 cm)
4
WOOD/COMPOSITE OVERLAY INSTALLATION
The bottom of the hood should be 30” (76.2 cm) min. to 36” (91.4 cm) max. above the countertop. This would
typically result in the bottom of the hood being 66” (167.6 cm) to 72” (182.9 cm) above the floor. Refer to the
rangehood installation instructions for further information. These dimensions provide for safe and efficient operation
of the hood.
WALL INSTALLATION
Wood/Composite Overlay
Metal Hood
30” (76.2 cm) min
36” (91.4 cm) max
ISLAND INSTALLATION
Wood/Composite Overlay
Metal Hood
30” (76.2 cm) min
36” (91.4 cm) max
66” - 72”
(167.6 cm -
182.9 cm)
36”
(91.4 cm)
DIMENSIONS
VECU HEIGHT
3 1/16”
(7.8 cm)
Countertop
66” - 72”
(167.6 cm -
182.9 cm)
Countertop
36”
(91.4 cm)
5”
(12.7 cm)
2 13/16”
(7.1 cm)
5