Viking DBCV, DBCV30821 User Manual

Page 1
Standard Features & Accessories
All models include
• Must purchase and install an interior­or exterior-power ventilator (motor) kit (see Installation Requirements table for recommendations)
• For use with custom hoods o The look and performance of Viking
ventilation in a blank canvas for virtually endless overlay options
o Easily installs into almost any custom
hood application
• Powerful enough to handle even the most pungent cooking odors
• Heat sensor on hood turns ventilator on full power when cooking temperatures reach uncomfortable levels
• Variable speed controls for custom venting—separate on/off switch allows you to leave ventilator at favorite/most-used setting
• Quiet fans also keep temperatures down
• Heavy-duty construction o Virtually seamless stainless steel
design with no visible screws
• Easy cleanup o Design of low-profile filter system
means less interior hood space to be cleaned
o Stainless steel liner for increased
rigidity, seamless appearance, and easy cleaning
• 50-watt halogen lights with dimmer control (bulbs included)
o Power switch and dimmer control
are separate, allowing you to leave dimmer at favorite position
o See Dimensions & Specifications
table for number of lights per model
Professional models include
• Professional-type size, design, and styling
• Heat lamps standard on wall ventilator systems (bulbs not included)
• Commercial-type baffle filter system efficiently removes grease and heated vapors from the air; especially designed for use with commercial­type products o See Dimensions & Specifications
table for number of filters per model
• Removable trough catches liquefied grease, making cleanup quick and easy
Designer models include
• Elegant design and styling
• 12-hour timer built into ventilator controls
• Delay feature allows you to set the ventilator to shut off on its own from 10 – 30 minutes later
• Dishwasher-safe, stainless steel mesh filters efficiently remove grease and heated vapors from the air, and are easily removed for quick cleaning o See Dimensions & Specifications
table for number of filters per model
VENTILATION
Built-In Custom Ventilator Systems
Model numbers
PROFESSIONAL CUSTOM WALL VENTILATOR SYSTEMS
custom wall hoods)
• VBCV30381—30"W./18"H./22"D.
• VBCV36381—36"W./18"H./22"D.
• VBCV42381—42"W./18"H./22"D.
• VBCV48381—48"W./18"H./22"D.
• VBCV54381—54"W./18"H./22"D.
• VBCV60381—60"W./18"H./22"D.
• VBCV66381—66"W./18"H./22"D.
ROFESSIONAL CUSTOM ISLAND
P VENTILATOR SYSTEMS (for use with
custom island hoods)
• VICV36981—36"W./18"H./29"D.
• VICV42981—42"W./18"H./29"D.
• VICV54981—54"W./18"H./29"D.
• VICV66981—66"W./18"H./29"D.
ESIGNER CUSTOM WALL VENTILATOR
D SYSTEMS (for use with custom wall
hoods)
• DBCV30821—30"W./12"H./18"D.
• DBCV36821—36"W./12"H./18"D.
• DBCV42821—42"W./12"H./18"D.
• DBCV48821—48"W./12"H./18"D.
DESIGNER CUSTOM ISLAND VENTILATOR SYSTEMS
hoods)
• DICV36321—36"W./12"H./23"D.
• DICV42321—42"W./12"H./23"D.
• DICV54321—54"W./12"H./23"D.
(for use with custom island
(for use with
Model Options
VBCV Professional
Custom Wall
Ventilator System
FINISH DETAILS
• Designed to be covered by custom materials—no standard exterior finish
• Stainless steel interior
• See Custom Panels section for more information and additional specifications.
P LA N N I N G A ND DE SI GN G U ID E
V I K I N G R A N G E . C O M 1 - 8 8 8 - V I K I N G 1
VICV Professional
Custom Island
Ventilator System
DBCV Designer
Custom Wall
Ventilator System
© 2 0 1 1 V R C — INFORMATION SUBJECT TO CHANGE
DICV Designer
Custom Island
Ventilator System
R E V I S E D 5 / 2 / 1 1
Page 2
27-
7/
16”
(
6
9
.
7
c
m
)
28-
7/
16”
(
7
2
.
2
c
m
)
A
1
7
-
1
/
4
(
4
3
.
8
c
m
)
6”
(
1
5
.
2
c
m
)
1
(
2
.
5
c
m
)
VENTILATION
16”
(
4
0
.
6
c
m
)
17-
1/
4”
(
4
3
.
8
c
m
)
A
1
1
-
3
/
4
(
2
9
.
8
c
m
)
5
(
1
2
.
7
c
m
)
1
(
2
.
5
c
m
)
21-
1/
8”
(
5
3
.
7
c
m
)
A
1
7
-
1
/
4
(
4
3
.
8
c
m
)
6”
(
1
5
.
2
c
m
)
1
(
2
.
5
c
m
)
21-
7/
8”
(
5
5
.
8
c
m
)
21”
(
5
3
.
3
c
m
)
22-
1/
4”
(
5
6
.
5
c
m
)
A
1
1
-
3
/
4
(
2
9
.
8
c
m
)
5
(
1
2
.
7
c
m
)
1
(
2
.
5
c
m
)
Built-In Custom Ventilator Systems
Please see
Installation Notes &
Accessories for
important information,
including ventilator
kits.
Dimensions & Specifications
PRODUCT DIMENSIONS
VBCV Professional
Custom Wall
Ventilator System
VBCV
VICV Professional
Custom Island
Ventilator System
DBCV Designer
Custom Wall
Ventilator System
DBCV
DICV Designer
Custom Island
Ventilator System
DICV
VICV
Model Hood Lights Filters Heat Approx.
VBCV30381 28-1/4” (71.8 cm) 21-7/8” (55.8 cm) 17-1/4” (43.8 cm) 22160 lbs. (27.0 kg) VBCV36381 34-1/4” (87.0 cm) 21-7/8” (55.8 cm) 17-1/4” (43.8 cm) 22168 lbs. (30.6 kg)
VBCV42381 40-1/4” (102.2 cm) 21-7/8” (55.8 cm) 17-1/4” (43.8 cm) 22176 lbs. (34.2 kg) VBCV48381 46-1/4” (117.5 cm) 21-7/8” (55.8 cm) 17-1/4” (43.8 cm) 33288 lbs. (39.6 kg) VBCV54381 52-1/4” (132.7 cm) 21-7/8” (55.8 cm) 17-1/4” (43.8 cm) 33296 lbs. (43.2 kg) VBCV60381 58-1/4” (148.0 cm) 21-7/8” (55.8 cm) 17-1/4” (43.8 cm) 442108 lbs. (48.6 kg) VBCV66381 64-1/4” (163.2 cm) 21-7/8” (55.8 cm) 17-1/4” (43.8 cm) 442121 lbs. (54.5 kg)
VICV36981 34-1/4” (87.0 cm) 28-7/16” (72.2 cm) 17-1/4” (43.8 cm) 44N/A 73 lbs. (33.1 kg) VICV42981 40-1/4” (102.2 cm) 28-7/16” (72.2 cm) 17-1/4” (43.8 cm) 44N/A 83 lbs. (37.7 kg) VICV54981 52-1/4” (132.7 cm) 28-7/16” (72.2 cm) 17-1/4” (43.8 cm) 66N/A 115 lbs. (52.2 kg)
VICV66981 64-1/4” (163.2 cm) 28-7/16” (72.2 cm) 17-1/4” (43.8 cm) 88N/A 128 lbs. (58.1 kg) DBCV30821 29-5/8” (75.2 cm) 17-1/4” (43.8 cm) 11-3/4” (29.8 cm) 22N/A 63 lbs. (28.4 kg) DBCV36821 35-5/8” (90.5 cm) 17-1/4” (43.8 cm) 11-3/4” (29.8 cm) 22N/A 70 lbs. (31.5 kg) DBCV42821 41-5/8” (105.7 cm) 17-1/4” (43.8 cm) 11-3/4” (29.8 cm) 23N/A 77 lbs. (34.7 kg) DBCV48821 47-5/8” (121.0 cm) 17-1/4” (43.8 cm) 11-3/4” (29.8 cm) 23N/A 85 lbs. (38.3 kg)
DICV36321 35-5/8” (90.5 cm) 22-1/4” (40.6 cm) 11-3/4” (29.8 cm) 42N/A 88 lbs. (40.0 kg)
DICV42321 41-5/8” (105.7 cm) 22-1/4” (40.6 cm) 11-3/4” (29.8 cm) 42N/A 96 lbs. (43.6 kg)
DICV54321 53-5/8” (136.2 cm) 22-1/4” (40.6 cm) 11-3/4” (29.8 cm) 43N/A 106 lbs. (48.1 kg)
Width (A) Depth Height Lamps Ship. wt.
P LA N N I N G A ND DE SI GN G U ID E
V I K I N G R A N G E . C O M 1 - 8 8 8 - V I K I N G 1
© 2 0 1 1 V R C — INFORMATION SUBJECT TO CHANGE
R E V I S E D 5 / 2 / 1 1
Page 3
Installation Requirements
VENTILATION
Built-In Custom Ventilator Systems
VBCV Professional
Custom Wall
Ventilator System
VICV Professional
Custom Island
Ventilator System
DBCV Designer
Custom Wall
Ventilator System
DICV Designer
Custom Island
Ventilator System
UTILITY REQU IREMENTS
Proper installation/ducting is extremely important to ensure maximum performance. Use a qualified and trained installer.
DUCTING
• Check with a qualified and trained installer or local codes for makeup air requirements, if any.
• Max. duct run length o For 300 – 1,200 CFM—
50’ (152.4 m)
o
For 1,500 CFM—75’ (22.9 m)
o Duct run length is for
general reference only; always use a qualified and trained installer.
Note: Exhaust capacity based on tests with 0.1 static pressure. Without applying static pressure (some brands do not), CFM could be greatly overstated.
Model Ventilator Kits
Interior Exterior
VBCV30381 VINV300/600/1200* DEV900/1200*
VBCV36381 VINV300/600/1200* DEV900/1200*
VBCV42381 VINV600/1200* DEV900/1200*
VBCV48381 VINV1200* DEV1200*/1500/DIL1200* 10” (25.4 cm) 10” (25.4 cm) 11.1 8.4/9.1/4.8
VBCV54381 VINV1200* DEV1200*/1500/DIL1200* 10” (25.4 cm) 10” (25.4 cm) 11.1 8.4/9.1/4.8
VBCV60381 VINV1200* DEV1200*/1500/DIL1200* 10” (25.4 cm) 10” (25.4 cm) 11.5 8.8/9.5/4.8
VBCV66381 VINV1200* DEV1200*/1500/DIL1200* 10” (25.4 cm) 10” (25.4 cm) 11.5 8.8/9.5/4.8
VICV36981 VINV600/VIV1200* DEV900/1200*/DIL900/DIL1200* 7” (17.8 cm) 10” (25.4 cm) 4.9/7.4 7.4/4.7/3.0/4.8
VICV42981 VINV600/1200*
VICV54981 VINV1200* DEV1200*/1500/DIL1200 10” (25.4 cm) 10” (25.4 cm) 8.2 5.6/6.2/4.8
VICV66981 VINV1200* DEV1200*/1500/DIL1200 10” (25.4 cm) 10” (25.4 cm) 9.0 6.3/7.1/4.8
DBCV30821 VINV300/600 DEV900**/1200*/DIL900/DIL1200 7” (17.8 cm) 10” (25.4 cm) 1.7/3.2 6.6/3.9/3.0/4.8
DBCV36821 VINV300/600 DEV900**/1200*/DIL900/DIL1200 7” (17.8 cm) 10” (25.4 cm) 1.7/3.2 6.6/3.9/3.0/4.8
DBCV42821 VINV600 DEV900**/1200*/DIL900/DIL1200 7” (17.8 cm) 10” (25.4 cm) 3.2 6.6/3.9/3.0/4.8
DBCV48821 VINV1200 DEV1200/1500/DIL1200* 10” (25.4 cm) 10” (25.4 cm) 5.6 4.3/5.1/4.8
DICV36321
DICV42321
DICV54321 VINV1200 DEV1200/1500/DIL1200 10” (25.4 cm) 10” (25.4 cm) 6.4 5.2/6.0/4.8
*1200 CFM interior and exterior (if applicable) ventilator should be used with all outdoor approved models and when indoor models are installed over
ranges/rangetops with gas grill.
**Must use 8” duct from canopy to ceiling – transition to 10” duct past duct cover.
VINV600 DEV900**/1200*
VINV600 DEV900**/1200/1500
DIL900/1200*
DIL900/1200*
DIL900/1200*
DEV900/1200*/1500/
DIL900/DIL1200*
DIL900/DIL1200
DIL900/DIL1200
o Straight runs and gradual
turns are best; for example, each 90° elbow is equivalent to 5’ – 10’ (1.52 – 3.05 cm) of straight run.
• 7” (17.8 cm) round duct for 300 – 600 CFM; 10” for 900 – 1500 CFM o Never use flexible duct; it
creates back pressure/air turbulence and greatly reduces performance.
GAS
Not applicable
Duct Size
Interior Exterior/In-Line
7” (17.8 cm)/ 10” (25.4 cm)
7” (17.8 cm) 10” (25.4 cm) 5.0/6.2/8.7 8.7/6.1/3.0/4.8
7” (17.8 cm) 10” (25.4 cm) 6.2/8.7 8.7/6.1/3.0/4.8
7” (17.8 cm) 10” (25.4 cm) 4.9 7.4/4.8/5.4/3.0/4.8
7” (17.8 cm) 10” (25.4 cm) 4.0 7.5/5.2/3.0/4.8
7” (17.8 cm) 10” (25.4 cm) 4.0 7.5/5.2/6.0/3.0/4.8
ELECTRICAL
• Hardwire direct with two-wire ground
• 120 VAC/60 Hz
• Max. amp usage (rating includes recommended ventilator kit rating)—see
Installation Requirements
table
PLUMBING
Not applicable
Max. Amps
Interior Exterior
10” (25.4 cm) 5.0/6.2/8.7 8.7/6.1/3.0/4.8
P LA N N I N G A ND DE SI GN G U ID E
V I K I N G R A N G E . C O M 1 - 8 8 8 - V I K I N G 1
R E V I S E D 5 / 2 / 1 1
© 2 0 1 1 V R C — INFORMATION SUBJECT TO CHANGE
Page 4
VENTILATION
Built-In Custom Ventilator Systems
Installation Notes & Accessories
Ventilator Kits
• See Installation Requirements table for recommendations for each hood model
• One ventilator, one duct run for any size hood/ventilator A 1,200 CFM interior or 1,500 CFM exterior (if applicable) ventilator should be used over ranges/rangetops with gas grill
• Must use Viking ventilator kits with Viking hoods; use of non-Viking kits voids product warranty
Kit model Description Hood models Approx. ship wt. lbs. (kg)
VINV300 300 CFM interior-power VBCV3038/3638 & DBCV3082/3682 27 (12.2) VINV600 600 CFM interior-power VBCV3038/3638/4238 & VICV3698/4298 27 (12.2)
DBCV3082/3682/4282 & DICV3632/4232
VINV1200 1,200 CFM interior-power VBCV3038/3638/4238/4838/5438/6038/6638 & 43 (19.4)
VICV3698/5498/6698 & DBCV4882 & DICV5432
DEV900 900 CFM exterior-power DBCV3082/3682/4282 & DICV3632/4232 39 (17.6)
VBCV3038/3638/4238 & VICV3698/4298
DEV1200 1,200 CFM exterior-power DBCV3082/3682/4282/4882 & DICV3632/4232/5432 53 (23.9)
VBCV4838/5438/6038/6638 & VICV3698/4298/5498/6698
DEV1500 1,500 CFM exterior-power DBCV4882 & DICV4232/5432 53 (23.9)
VBCV4838/5438/6038/6638 & VICV4298/5498/6698
DIL900 900 CFM in-line power DBCV3082-DBCV4282 & DICV3632/4232 20 (9.1)
VBCV3038/3638/4238 & VICV3698/4298
DIL1200 1,200 CFM in-line power DBCV3082-DBCV4882 & DICV3632-DICV5432 25 (11.3)
VBCV3038-VBCV6638 & VICV3698-VICV6698
Compliance Information
WARRANTY SUMMARY*
• Three-year full warranty—complete product (Professional and Designer)
• Five-year limited warranty—all ventilator motors (Professional and Designer)
• Ninety-day limited warranty—cosmetic parts such as glass, painted, and decorative items (Professional and Designer)
*Must use Viking ventilator kits with Viking hoods; use of non-Viking kits voids product warranty. For complete warranty see Use & Care Guide.
Warranty valid on Viking products shipped within the United States and Canada.
P LA N N I N G A ND DE SI GN G U ID E
V I K I N G R A N G E . C O M 1 - 8 8 8 - V I K I N G 1
© 2 0 1 1 V R C — INFORMATION SUBJECT TO CHANGE
R E V I S E D 5 / 2 / 1 1