The C-2000B now offers two operational modes for added flexibility.
In the Single Line Ring Through Mode, the C-2000B allows single line
phones to share a phone line with 1 to 4 entry phones. Tenants may converse with visitors and activate a contact closure to control gates or
strikes. The C-2000B provides entry phone “Caller ID” and “Call Waiting
Caller ID” and a “Call Waiting” tone when the phone lines is in use.
Tenants may gain entry at each location by entering a keyless entry code.
In the Analog Station Dial Through Mode, the C-2000B allows 1 to 4 entry
phones to share one analog PABX extension or telephone line and place
outgoing calls. When a remote party answers, they can converse with
visitors and activate a contact closure to control gates or strikes.
Monitoring entry phones, forcing doorstrike relays to operate or remote programming of the C-2000B can be accomplished by
calling the analog PABX extension or telephone line connected. Authorized personnel may gain entry at each location by entering a keyless entry code.
In either operational mode, the secure relay control of the C-2000B prevents the entry phone from dialing the activation code
on the keypad of the entry phone or using a hand held touch tone dialer. An auxiliary input is available for connecting a lighted doorbell switch, a common garage door opener/receiver or an auxiliary keyless entry keypad.
Add Entry Phones and Doorstrike Control to an Existing
Line Or Securely Operate Multiple Doorstrikes
hhttttpp::////wwwwww..vviikkiinnggeelleeccttrroonniiccss..ccoom
m
• Allows 1-4 entry phones to share a single telephone
line with a residential or business telephone system
• Compatible with the following Viking entry phones:
- E-10A, E-20B, E-30, E-35, E-40, E-50, E-60, E-65,
E-70, and E-75 Phones
- K-1500-7 Stainless Steel Panel Phone
- K-1700-3 and K-1705-3 Phone with Keypad
- K-1900-8 Stainless Steel Panel Phone with Keypad
- Or use with any analog touch tone phone
• Provide entry phone activated chimes and whole
house paging when used with an SLP-1 or SLP-4
• Up to 6 different keyless entry codes / “one time
use” keyless entry codes per entrance
• Up to 6 master keyless entry codes for use at any
entrance
• Analog Station Dial Through Mode allows entry
phones to connect to analog PABX station or
telephone line
• Optional “Privacy Number” allows only selected
visitors to call from an entry phone
• Provides “Caller ID” and “Call Waiting Caller ID”
• Produces “Call Waiting” tones
• Lighted doorbell switch input to activate entry
phone call
• One set of normally open and normally closed
contacts available for each entry phone
• Programmable contact activation time
• Auxiliary input to activate timed auxiliary contacts
Power: 120VAC / 13.8VAC 1.25A, UL listed adapter provided
Dimensions: 210mm x 159mm x 45mm (8.25" x 6.25" x 1.75")
Shipping weight: 1.5kg (3.2 lbs.)
Environmental: 0°C to 32°C (32°F to 90°F) with 5% to 95%
non-condensing humidity
Relay Contacts: 5A @ 30VDC/250VAC
Ring Output: 8 REN, capable of ringing (16) 0.5 REN phones
Talk Battery: 40V DC
REN: 0.1A
Connections: (32) cage clamp screw terminals
PPrraaccttiicce
e
T
T
EELLEECCOOM
M
S
S
OOLLUUTTIIOONNSSFFOORRTTHHE
E
221
1
SST
T
C
C
EENNTTUURRY
Y
TECHNICAL
TECHNICAL
FFeeaattuurrees
s
SSppeecciiffiiccaattiioonns
s
• Add one to four entry phones to your standard home or
office phones to provide:
- Door communication
- Door entry
- Gate entry
- Keyless entry
• Provide commercial or residential security via two-way
handsfree communication at the door and gate
• Connects in series with a single phone line or to a
phone system’s unused line input (loop start trunk input)
• High security building entry systems
• Doorstrikes and gates in conjunction with entry phones or
hot-line/panel phones
AApppplliiccaattiioonns
s
C-2000B
C-2000B
Advanced Door/Gate
Entry Phone Controller
February 22, 2011

IF YOU HAVE A PROBLEM WITH A VIKING PRODUCT, PLEASE CONTACT: VIKING TECHNICAL SUPPORT AT (715) 386-8666
Our Technical Support Department is available for assistance Monday 8am - 4pm and Tuesday through Friday 8am - 5pm central time. So that we can give you better service, before you call please:
1. Know the model number, the serial number and what software version you have (see serial label).
2. Have your Technical Practice in front of you.
3. It is best if you are on site.
RETURNING PRODUCT FOR EXCHANGE
The following procedure is for equipment that has failed out-of-box (within 10 days of purchase):
1. Customer must contact Viking’s Technical Support at 715-386-8666 to determine possible causes for the problem. The customer
MUST be able to step through recommended tests for diagnosis.
2. If the Technical Support Product Specialist determines that the equipment is defective based on the customer's input and troubleshooting, a Return Authorization (R.A.) number will be issued. This number is valid for fourteen (14) calendar days from the
date of issue.
3. After obtaining the R.A. number, return the approved equipment to your distributor, referencing the R.A. number. Your distributor
will then replace the product over the counter at no charge. The distributor will then return the product to Viking using the same
R.A. number.
4. The distributor will NOT exchange this product without first obtaining the R.A. number from you. If you haven't followed
the steps listed in 1, 2 and 3, be aware that you will have to pay a restocking charge.
RETURNING PRODUCT FOR REPAIR
The following procedure is for equipment that needs repair:
1. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (RA) number.
The customer MUST have a complete description of the problem, with all pertinent information regarding the defect, such as
options set, conditions, symptoms, methods to duplicate problem, frequency of failure, etc.
2. Packing: Return equipment in original box or in proper packing so that damage will not occur while in transit. Static sensitive equipment such as a circuit board should be in an anti-static bag, sandwiched between foam and individually boxed. All equipment
should be wrapped to avoid packing material lodging in or sticking to the equipment. Include ALL parts of the equipment. C.O.D.
or freight collect shipments cannot be accepted. Ship cartons prepaid to: Viking Electronics, 1531 Industrial St, Hudson, WI 54016
3. Return shipping address: Be sure to include your return shipping address inside the box. We cannot ship to a PO Box.
4. RA number on carton: In large printing, write the R.A. number on the outside of each carton being returned.
FFeeaattuurreessOOvveerrvviieew
w
WARRANTY
Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of one year from the date of purchase from any authorized Viking distributor or 18 months from the date manufactured, which ever is
greater. If at any time during the warranty period, the product is deemed defective or malfunctions, return the product to Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI., 54016. Customer must contact Viking's Technical Support Department at 715-3868666 to obtain a Return Authorization (R.A.) number.
This warranty does not cover any damage to the product due to lightning, over voltage, under voltage, accident, misuse, abuse, negligence or any damage caused by use of the product by the purchaser or others.
Vikings sole responsibility shall be to repair or replace (at Viking's option) the material within the terms stated above. VIKING SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESSED OR IMPLIED, OR FOR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages,
so this limitation may not apply to you.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY EXCLUDED BEYOND THE ONE YEAR
DURATION OF THIS WARRANTY. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
2
If trouble is experienced with the C-2000B, for repair or warranty information, please contact:
Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI 54016 (715) 386-8666
If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the
equipment until the problem is resolved.
Connection to Party Line Service is subject to State Tariffs. Contact the state public utility commission, public service commission or corporation commission for information.
WHEN PROGRAMMING EMERGENCY NUMBERS AND (OR) MAKING TEST CALLS TO EMERGENCY NUMBERS:
Remain on the line and briefly explain to the dispatcher the reason for the call. Perform such activities in the off-peak
hours, such as early morning or late evenings.
It is recommended that the customer install an AC surge arrester in the AC outlet to which this device is connected. This
is to avoid damaging the equipment caused by local lightning strikes and other electrical surges.
PART 15 LIMITATIONS
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at his own expense.
FCC REQUIREMENTS
This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On the side of this
equipment is a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX. If
requested, this number must be provided to the telephone company.
The REN is used to determine the number of devices that may be connected to a telephone line. Excessive REN's on a
telephone line may result in the devices not ringing in response to an incoming call. In most but not all areas, the sum of
the REN's should not exceed five (5.0) To be certain of the number of devices that may be connected to a line, as determined by the total REN's, contact the local telephone company. For products approved after July 23, 2001, the REN for
this product is part of the product identifier that has the format US:AAAEQ##TXXXX. The digits represented by ## are the
REN without a decimal point (e.g., 03 is a REN of 0.3). For earlier products, the REN is separately shown on the label.
The plug used to connect this equipment to the premises wiring and telephone network must comply with the applicable
FCC Part 68 rules and requirements adopted by the ACTA. If your home has specially wired alarm equipment connected
to the telephone line, ensure the installation of this C-2000B does not disable your alarm equipment. If you have questions about what will disable alarm equipment, consult your telephone company or a qualified installer.
If the C-2000B causes harm to the telephone network, the telephone company will notify you in advance that temporary
discontinuance of service may be required. But if advance notice isn't practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the
operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make
the necessary modifications to maintain uninterrupted service.
(13.8VAC @1.25A adapter included)
Analog Station Mode LED: Indicates
unit is in Analog Station Mode (DIP switch 5 ON)
Phone Mode LED: Indicates unit
is in Phone Mode (DIP switch 5 OFF)
Optional Earth Ground: To increase surge
protection, fasten a wire from the screw terminal
to Earth Ground (grounding rod, water pipe, etc.)
C.O. / Phone Line Input: (If installing without a CO
line in "Single Line Ring Through Mode", "*5" must be
Line Out to Telephones: (can connect to an unused
line / trunk input on a phone system. DIP switch 5 OFF)
Analog Station Input: (can be connected to an
unused analog PABX/KSU station port. DIP switch 5 ON)
programmed. See page 6, section D.)
Power Input
DIP Switches:
(see Installation section D)
Entry Phone 1 Input
* Door Strike 1
Relay Contact Output
COM
Entry Phone 2 Input
* Door Strike 2
Relay Contact Output
N.O.
N.C.
N.O.
COM
N.C.
VIKING
PWR 13.8 VAC
EARTH GND
PHONE LINE
INPUT
LINE OUT
TO PHONES
1 2 3 4 5 6 78910 11 12 13 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
on
123
4 5
LED1 LED2
C C
©
VIKING
ELECTRONICS
HUDSON, WI 54016
ADVANCED DOOR/GATE AND
ENTRY PHONE CONTROLLER
ENTRY PHONE 1
DOOR STRIKE 1
ENTRY PHONE 2
ANALOG STATION
INPUT
1
LED3
DOOR STRIKE 2
14
J8-
J7-
1
2
3
2
LED4
MODEL C-2000B
ENTRY PHONE 3
DOOR STRIKE 3
ENTRY PHONE 4
DOOR STRIKE 4
J10-
J9-
1
3
3
12
2
3
LED6
LED5
CCCC
DOORBELL SWITCH /
AUX. INPUT
1
LED7
Connect to a doorbell switch (lighted or non-lighted) momentary
SPST, 6-16V bulb. Note: Unit must be in Doorbell Mode (DIP switch 1
ON). Or use as an Auxiliary Input, allowing connection to a momentary
SPST switch, keyed switch, postal lock with limit switch, etc. Note:
Unit must be in Auxiliary Contact Mode DIP switch 1 must be OFF.
AUX. CONTACT
J11-
2
OUTPUT
3
Note: The C-2000B is not recommended to be
installed in combination with the TR-1 Tol l
Restrictor. Contact your local C.O. for toll
restriction requirements.
* Note: For doorstrike / magnetic lock information,
contact your local locksmith.
C
N.C.
Auxiliary Relay
COM
Contact Output
N.O.
Doorbell Switch / Auxiliary Input
N.C.
* Door Strike 4
COM
Relay Contact Output
N.O.
Entry Phone 4 Input
N.C.
* Door Strike 3
COM
Relay Contact Output
N.O.
Entry Phone 3 Input

OOppeerraattiinnggMMooddees
s
A. Single Line Ring Through Mode (DIP Switch 5 OFF)
B. Analog Station Dial Through Mode (DIP Switch 5 ON)
IMPORTANT: Please read the following sections to determine which C-2000B mode works best for your application.
The C-2000B has two operational modes built in, called the “Single Line Ring Through Mode” and “Analog Station Dial
Through Mode”. The “Single Line Ring Through Mode” is the residential “line sharing” mode that existed in all previous versions of the C-2000B controller. The “Analog Station Dial Through Mode” is a new mode added in C-2000B that allows
entry phones to connect to one common analog PABX extension or telephone line and use that line to dial out. The controller then acts as a multiple Entry Phone and secure relay controller, with keyless entry capability if needed.
This mode is used in many residential entry applications (typical residence with a single telephone line and single line
phones). The controller provides a “line sharing” function so the phones in the house can make and receive calls on
the telephone line as normal. When an entry phone is activated, the C-2000B rings the house phones in a custom
double ring cadence and caller ID data is generated to identify which entry phone is calling. If a house phone is already
on a phone call when the entry phone is activated, the controller provides call waiting beeps to the house phone (and
call waiting caller ID information). The person on the house phone has the option of putting their phone call on hold to
talk with the entry phone. While communicating with an entry phone, the house phones can dial a touch tone command to activate the doorstrike relay. The house phones also have the ability to monitor an entry phone or force a
doorstrike relay to operate through touch tone commands. Touch tone keyless entry codes can be programmed per
entry phone to provide keyless entry.
The C-2000B can also be connected in series between the C.O. line and the line/trunk input of a phone system. The
operation remains the same as the single line residential application described above, but you must first access the
line/trunk in order to monitor an entry phone or force a doorstrike relay.
In this mode, the entry phone is allowed to access the analog PABX extension or telephone line the C-2000B is connected to and then use that line to call an extension or telephone number. When the remote party answers the call,
they can dial a touch tone command to activate the doorstrike relay. If one of the entry phones is using the line and a
second entry phone goes off hook, it will receive a busy signal (generated by the C-2000B) until the line becomes available. In this mode, custom double ring cadence from the Entry Phone is not compatible, no caller ID data is generated by the controller and no “entry phone identifier beeps” are provided when the call is answered. Monitoring an entry
phone or forcing a doorstrike relay to operate is accomplished by calling the analog PBX extension or telephone line
connected to the C-2000B and entering a valid touch tone command. Remote programming of the C-2000B and any
of the Viking hands-free entry phones connected is also possible in this mode. Touch tone keyless entry codes can
be programmed per entry phone to provide keyless entry.
* Note: Keypads used for keyless entry only.
** Note: A C.O. line is not required, but the unit must be programmed with (
5), see page 6, section D.
3
C.O. Line or
VoIP ATA
Phone
Line Input
(terminals 2&3)
E-10A E-60E-40 *K-1700-3
Ring
Gen
C-2000B
Ring
Ring
Gen
Gen
Ring
Gen
House
Phones
Line out
to phones
(terminals 4&5)
**C.O. Line or
VoIP ATA
Phone
Line Input
(terminals 2&3)
E-10A E-60E-40 *K-1700-3
Ring
Gen
C-2000B
Ring
Ring
Gen
Gen
Ring
Gen
Phone line/
trunk input
to phones
(terminals 4&5)
PABX
Line out
Phone System/
Stations

Installation and Applications
Installation and Applications
Note: The C-2000B is not recommended to be
installed in combination with the TR-1 Toll Restrictor.
Contact your local C.O. for toll restriction requirements.
Door Strikes/Magnetic Locks: For door strike/magnetic
lock information, contact your local locksmith.
Many different Viking door
phones may be used in combination with the C-2000B.
Doorbell Switch/Auxiliary Input: Connect to a doorbell switch (lighted or non-lighted) momentary SPST, 616V bulb. Note: Unit must be in Doorbell Mode (DIP
switch 1 ON). Or use as an Auxiliary Input, allowing
connection to a momentary SPST switch, keyed
switch, postal lock with limit switch, etc. Note: Unit
must be in Auxiliary Contact Mode DIP switch 1 must
be OFF.
* Note: To increase surge
protection, fasten a wire
from the screw terminal to
Earth Ground (grounding
rod, water pipe, etc.)
A. One to Four Entry Phones Sharing a Single Phone Line with House Phones
SINGLE LINE RING THROUGH MODE
SINGLE LINE RING THROUGH MODE
4
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the
telephone line. It is recommended that a surge protector be installed to protect against such surges. Contact Panamax at (800)
472-5555 or Electronic Specialists Inc. at (800) 225-4876.
!
Dial into
IMPORTANT: The following Installation and Applications, Programming and Operation sections
(pages 4-11) are for use in the Single Line Ring Through Mode only (DIP switch 5 OFF). This mode
is used in the majority of residential entry applications (typical residence with a single telephone line
and single line phones). See the complete mode description on page 3.
Apartment or
Office Phones
Call
Phone Line/
Trunk Inputs
Phone System/
PABX
Phone
Line Input
(not used)
(terminals 2&3)
*K-1700-3
C-2000B
(with built in
auto-dialer)
*K-1900-8
E-30
C.O. Line
Analog
Station Input
(terminals 6&7)
K-1900-30
(auto dialer)
E-40-PB
Phone
Line Input
(not used)
(terminals 2&3)
*K-1700-3
C-2000B
E-30
(with built in
auto-dialer)
*K-1900-8
Analog
Station Input
(terminals 6&7)
K-1900-30
(auto dialer)
Analog
Station
Output
E-40-PB
*Note: Keypads used for dialing and keyless entry.
DIP Switch 5 must be OFF
(see DIP Switch Programming in
Programming section D, page 8)
To Standard
Analog Touch
Tone House
Phone(s)
C.O. / Phone
Line Input
120V AC
13.8V AC
Adapter
(included)
* Earth
Ground
(optional)
VIKING
PWR 13.8 VAC
EARTH GND
PHONE LINE
INPUT
LINE OUT
TO PHONES
1 2 3 4 5 6 78910 11 12 13 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
on
123
4 5
LED1 LED2
C C
Entry Phone 1
(E-40-PB shown,
not included)
©
VIKING
ELECTRONICS
HUDSON, WI 54016
ADVANCED DOOR/GATE AND
ENTRY PHONE CONTROLLER
ANALOG STATION
INPUT
ENTRY PHONE 1
DOOR STRIKE 1
ENTRY PHONE 2
DOOR STRIKE 2
14
J8-
J7-
1
1
2
LED3
Entry Phone 2
(E-60-BN shown,
not included)
2
3
LED4
MODEL C-2000B
ENTRY PHONE 3
DOOR STRIKE 3
1
3
LED5
Entry Phone 3
(K-1700-3 shown,
not included)
ENTRY PHONE 4
DOOR STRIKE 4
DOORBELL SWITCH /
AUX. INPUT
AUX. CONTACT
OUTPUT
J10-
J9-
3
2
LED6
J11-
3
12
To Entry
Phone 4
3
2
1
LED7
CCCC
A contact closure output is available for each
entry phone. An auxiliary output is also available.
Optional Doorbell Switch
C
required for gate controllers)
(not included, see Programming
section M on page 9)
or
Entry Phone 4
(E-30 shown,
not included)
(Power typically not
Optional Postal Lock
(not included)
5A@30VDC/
250VAC
maximum
Magnetic Lock
Doorstrike/

The SLP-4 can be used with the Viking C-2000B entry phone controller. The phone line first runs through the SLP-4,
then runs through the C-2000B before continuing on to the house phones. The C-2000B ’s normally open Aux Contact
Output connections, when wired to the SLP-4’s Trig1 input, will play the SLP-4’s DIP Switch selected recorded door
chime whenever Entry Phone 1, 2, 3 or 4 call in. To provide up to 4 different door chimes, the SLP-4’s “Doorbell Mode”
dip switch must be turned ON, and the C-2000B must have the “Auxiliary Contact Mode” enabled (DIP switch 1 OFF)
and have the auxiliary contact programmed for “Entry Phone Triggered Ring Cadence Activation” (3#60). Entry phone
ringing can also be disabled (0#62). * IMPORTANT: See the SLP-4 Technical Practice for complete programming
instructions (DOD# 479).
B. Provide Paging with Four Different CD Quality Door Chimes and Control of up to Four
Entry Phones and Doorstrikes from a Single Phone Line with the Viking C-2000B and SLP-4
C. Provide Whole House Paging, Control Up to 4 Entry Phones and Doorstrikes and Provide
Entry Phone Triggered Unique Front and Back Door Chimes from a Single Phone Line
Note: To provide unique front and back door chimes, the C-2000B must have the “Auxiliary Contact Mode” enabled
(DIP switch 1 OFF) and have the auxiliary contact programmed for “Entry Phone Triggered Ring Cadence Activation”
(3#60). Entry phone ringing can also be disabled (0#62). If CCTV video control is required, up to (2) VC-1000’s can be
used. See Programming section B, page 7.
* Important: See the SLP-1
Technical Practice for complete programming instructions (DOD# 478).
5
C.O. / Phone Line
VIKING
POWER
13.8 VAC
MUSIC ON
HOLD INPUT
CO LINE
INPUTGND
SINGLE LINE PAGING CONTROLLER
TRIGGERED AUDIO CHIMES / MESSAGES
CHIME/MESSAGE SELECTIONS
WAVE
USB
FILE
LED
INPUT
USB
OUT TO
PHONES
USB TRIG 1
WITH FOUR RECORDABLE
TRIGGERED AUDIO
PER TRIGGER INPUT
1234
MSG
MSG MSG
TRIG 2 TRIG 3 TRIG 4
MODEL SLP-4
©
VIKING
ELECTRONICS
HUDSON, WI 54016
POWER MUTE AUDIO PAGE
MSG
LOUD
+ -
RING
IO COM
*DIP Switch 1
must be ON
DOORBELL MODE
ON HOLD ALARM
DIAL "9"
PAGE
POWER
MUTE AUDIO PAGE
+ SPK -
OUTPUT
TRIGGERED AUDIO
PLAYBACK VOLUME
PAGE
VOLUME
LOUD RINGING
VOLUME
2 WATT
AMP GAIN
PAGE TRIGGER
OUTPUT
DRY
WET
12VDC
COM
N.O.
N.C.
+
To "Page" input on
your whole house
audio controller.
VIKING
PWR 13.8 VAC
EARTH GND
PHONE LINE
INPUT
LINE OUT
TO PHONES
1 2 3 4 5 6 78910 11 12 13 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
on
123
4 5
LED1 LED2
C C
DIP Switch 1 and 5 must
be OFF (see Programming
section D, page 8)
©
VIKING
ELECTRONICS
HUDSON, WI 54016
ADVANCED DOOR/GATE AND
ENTRY PHONE CONTROLLER
ENTRY PHONE 1
DOOR STRIKE 1
ENTRY PHONE 2
ANALOG STATION
INPUT
J7-
1
2
LED3
DOOR STRIKE 2
14
J8-
1
2
3
3
LED4
MODEL C-2000B
ENTRY PHONE 3
DOOR STRIKE 3
ENTRY PHONE 4
DOOR STRIKE 4
J10-
J9-
1
3
3
12
2
LED6
LED5
CCCC
To Additional
Standard
Analog Phones
Standard
Analog Phone
DOORBELL SWITCH /
AUX. INPUT
AUX. CONTACT
OUTPUT
J11-
3
2
1
LED7
C
To Entry
Phones
120V AC
13.8V AC
Adapter
(included)
C.O. /
Phone Line
To Optional Speakers
or Paging Horns
VIKING
PREAMP
VOLUME
MIN MAX
PWR 13.8 VAC
DOOR BELL
SW. INPUT
C.O. LINE
INPUT
PAGING CONTROLLER
MUSIC
INPUT
- +
LOUD RING
- +
PAGE TRIG. OUT
ENABLE
I.O. COM.
OUT TO
- SPKR +
PHONES
OUTPUT
HOLD
©
MODEL SLP-1
2 WATT
VIKING
ELECTRONICS
HUDSON, WI 54016
AMP GAIN
MIN MAX
SINGLE LINE
AUDIO
ON
INPUT
L R
PWR
LLRR
on your whole house
1/8" (3mm) Double Ended
Audio Cord (included)
AUDIO
OUTPUT
L R
ON
1 2 3
PAGE MUTE
To "Page" input
audio controller
120V AC
13.8V AC
Adapter
(included)
ON
ON
OFF
1 2 3
*DIP switch 2
must be ON
Music On Hold
Source (Radio)
VIKING
PWR 13.8 VAC
EARTH GND
PHONE LINE
INPUT
LINE OUT
1 2 3 4 5 6 78910 11 12 13 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
on
123
4 5
LED1 LED2
©
HUDSON, WI 54016
ADVANCED DOOR/GATE AND
ENTRY PHONE CONTROLLER
ENTRY PHONE 1
DOOR STRIKE 1
TO PHONES
ANALOG STATION
INPUT
14
J7-
1
3
2
LED3
C C
MODEL C-2000B
VIKING
ELECTRONICS
ENTRY PHONE 2
DOOR STRIKE 2
ENTRY PHONE 3
J8-
1
1
2
3
LED5
LED4
DOOR STRIKE 3
ENTRY PHONE 4
J9-
3
2
DOOR STRIKE 4
J10-
12
LED6
DOORBELL SWITCH /
AUX. INPUT
3
LED7
CCCC
To Doorstrike/Magnetic Lock
To Standard Analog Phones
or Viking Entry Phones models:
E-10A, E-20B, E-30, E-35, E-40,
E-50, E-60, E-65, E-70, E-75,
Standard
Analog
Phone
K-1500-7, K-1700-3 or K-1900-8.
To Additional Standard
Analog Phones
DIP Switch 1 and 5
must be OFF
(see Programming
AUX. CONTACT
OUTPUT
J11-
3
2
1
section D, page 8)
C