Viking blk-3 Service Manual

Page 1
BLK-3-EWP
BLK-3-EWP
Line Status Strobe
Light Kit with EWP
November 21, 2002
PPrraaccttiicce
e
T
T
EELLEECCOOM
M
S
S
OOLLUUTTIIOONNSSFFOORRTTHHE
E
221
1
SST
T
C
C
EENNTTUURRY
Y
TECHNICAL
TECHNICAL
Ideal for Use with Two-Button Emergency Phones!
The BLK-3-EWP provides high visibility indication of analog line status through a high powered one million candle power strobe light. The BLK-3- EWP is the ideal solution for the hearing impaired and can be used equal­ly well in loud warehouses or factories, where ringing phones can not be heard. Alternatively, the BLK-3-EWP can be used to add emergency noti­fication to pre-existing emergency phones by turning on the strobe light when the emergency phone is in use.
The included LDB-3 control module has a disable input which is ideal for two-button emergency phones, such as Viking’s E-1600-20A, allowing “Info” button calls to be placed without activating the relay (turning on the
LDB-3 control module with Enhanced Weather Protection (EWP) included
• Durable polycarbonate lens
• Long life 1 million candle power blue strobe light
• Flush mount or surface mount with weatherproof single gang box (included)
• 3/4” knockouts for connecting conduit, etc.
• Strobe and control module may be installed separately
• Can be configured to signal: ringing, off-hook, or a combination of both ringing and off-hook (line in-use)
• One set of (NO) normally open and (NC) normally closed relay contacts provided
• Selectable ring cadence mode (strobe light will remain flashing between rings)
• Switched 12V DC output (follows relay activation for powering strobe lights, cameras, etc.)
• On/off switches for ring detection and off-hook/loop detection
• Disable input, ideal for use with two-button emergency phones (E-1600-20A), will not activate strobe light on “Info” calls
FFeeaattuurrees
s
PPhhoonnee......771155..338866..8888661
1
Power: 120V AC to 12V DC adapter provided Strobe Dimensions: 111mm diameter x 69mm (4.38" x 2.75") Control Module Dimensions: 74mm x 53mm x 25mm (2.9" x
2.1" x 1.0”)
Shipping Weight: 1.5 kg (3.3 lbs) Operating Temperature: -26° to 54°C (-15° to 130° F) Relay Contact Rating: .5A @ 125V AC/1A @ 30V DC Minimum Loop Current: 15 mA Minimum Ring Voltage: 25V RMS Strobe Output: 1 million candle power @ 1 second flash rate Ringer Equivalence: 0.5 A REN Disable/Info Switch Input: 50mA/80mW maximum Mounting: Fasten to wall, post, etc. with complete surface
mounting hardware included Connections: Color coded wires with gel-filled butt connectors
AApppplliiccaattiioonns
s
SSppeecciiffiiccaattiioonns
s
emergency strobe light, camera, etc.) Three DIP switches are provided for turning ring detection on or off, off-hook/loop detection on or off and for selecting a ring cadence mode which allows the relay to fol­low ringing or to remain activated during the off time of standard ring cadence.
The control module can be installed on any standard telephone line or analog PABX/KSU station. The 1 million candle power strobe can be interfaced to flash on ringing, off-hook or a combination of ringing and off-hook (line in-use). The LDB-3 ring/loop detect control module is also available separately.
The kit includes: (1) LDB-3 control module, (1) blue strobe light, (1) 12V DC power adapter, (13) gel­filled butt connectors and (1) single gang weatherproof mounting box with gaskets and hardware.
Provide Strobe Light Indication
of Line Status
• Ringing Phone or TTY indication for the hearing impaired
• Ringing phone indication in loud warehouses and factories
• Emergency illumination for emergency phones in elevators, campuses, hallways, parking ramps, etc.
• Alarm indication for security systems or alarm panels with phone dialers
?
Need More Information on EWP?
Call (715) 386-4345 and select 859.
?
Need More Information on the LDB-3?
Call (715) 386-4345 and select 409.
?
Need More Information on the E-1600-20A?
Call (715) 386-4345 and select 215.
Page 2
Z3
Z2
R4 R7 R9 R8
CR
A. Installing the Strobe Light Using the Included Weatherproof Box
Z3
Z2
R4 R7 R9 R8
CR
Z3
Z2
R4 R7 R9 R8
CR
Back view of weatherproof single gang box (included)
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the telephone line. It is recommended that a surge protector be installed to protect against such surges. Contact Panamax at (800) 472-5555 or Electronic Specialists Inc. at (800) 225-4876.
!
Side View of the
Strobe Light (included)
IInnssttaallllaattiioon
n
* Note: The gel-filled (water tight) butt connectors are designed for insulation
displacement. Do not strip wires prior to terminating.
* Note: The gel-filled (water tight) butt con­nectors are designed for insulation displace­ment. Do not strip wires prior to terminating.
W
Waarrrraannttyy
IF YOU HAVE A PROBLEM WITH A VIKING PRODUCT, PLEASE CONTACT: VIKING TECHNICAL SUPPORT AT (715) 386-8666
Our Technical Support Department is available for assistance weekdays between 8 a.m. and 5 p.m. central time. So that we can give you better service, before you call please:
1. Know the model number, the serial number and what software version you have (see serial label).
2. Have your Technical Practice in front of you.
3. It is best if you are on site.
RETURNING PRODUCT FOR REPAIR
The following procedure is for equipment that needs repair:
1. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (RA) number. The customer MUST have a complete description of the problem, with all
pertinent information regarding the defect, such as options set, conditions, symptoms, methods to duplicate problem, frequency of failure, etc.
2. Packing: Return equipment in original box or in proper packing so that damage will not occur while in transit. Static sensitive equipment such as a circuit board should be in an anti-static bag, sandwiched between foam and individually boxed. All equipment should be wrapped to avoid packing material lodging in or sticking to the equipment. Include ALL parts of the equipment. C.O.D. or freight collect shipments cannot be accepted. Ship cartons prepaid to: Viking Electronics, 1531 Industrial Street, Hudson, WI 54016
3. Return shipping address: Be sure to include your return shipping address inside the box. We cannot ship to a P.O. Box.
4. RA number on carton: In large printing, write the R.A. number on the outside of each carton being returned.
RETURNING PRODUCT FOR EXCHANGE
The following procedure is for equipment that has failed out-of-box (within 10 days of purchase):
1. Customer must contact Viking’s Technical Support at 715-386-8666 to determine possible causes for the problem. The customer MUST be able to step through recommended tests for diagnosis.
2. If the Technical Support Product Specialist determines that the equipment is defective based on the customer's input and troubleshooting, a Return Authorization (R.A.) number will be issued.
This number is valid for fourteen (14) calendar days from the date of issue.
3. After obtaining the R.A. number, return the approved equipment to your distributor, referencing the R.A. number. Your distributor will then replace the product over the counter at no charge. The distributor will then return the product to Viking using the same R.A. number.
4. The distributor will NOT exchange this product without first obtaining the R.A. number from you. If you haven't followed the steps listed in 1, 2 and 3, be aware that you will have to pay a restocking charge.
WARRANTY
Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of one year from the date of purchase from any authorized Viking dis­tributor or 18 months from the date manufactured, which ever is greater. If at any time during the warranty period, the product is deemed defective or malfunctions, return the product to Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI., 54016. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (R.A.) number.
This warranty does not cover any damage to the product due to lightning, over voltage, under voltage, accident, misuse, abuse, negligence or any damage caused by use of the product by the pur­chaser or others.
Vikings sole responsibility shall be to repair or replace (at Viking's option) the material within the terms stated above. VIKING SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESSED OR IMPLIED, OR FOR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR­POSE, WHICH ARE HEREBY EXCLUDED BEYOND THE ONE YEAR DURATION OF THIS WARRANTY. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
LDB-3 Control Module
120V AC
Z3
R 5
R4 R7
CR
R9
2
7 8 9 10 11
R8
R 2
Z2
1 2 3 4 5 6
* Gel-Filled Butt
Connectors (included)
12V DC adapter (included)
(+) Black
(-) Black with
White stripe
(+) Red with Black stripe
(-) Black with
White stripe
Red
Black
Orange
Z3
R4 R7 R9 R8
Z2
Purple
R 5
Yellow
CR
Blue
2
R
Blue
2
Gray
Brown
Green w/ Yellow Stripe
Red w/ Yellow Stripe
1 2 3 4 5 6 7 8 9 10 11
Switched 12VDC Output (Strobe Light Power)
Normally Closed
Relay Contacts
Common
Normally Open
Disable/Info Switch Input
To Terminal Device/Phone
To C.O. Line or Analog PABX/KSU Station
4.0
(2) 10-32 x 3/8" self
tapping screws
Nipple 1/2" x close
(2) 6-32 x 3/4" screws
* Gel-Filled Butt
Connectors (included)
2.75
0.6
1.05
4.60
4.4
2.50
1.50
2.84
(2) Knockout
Plugs
2.0
Blue Strobe
Light
Foam
Gasket
Strobe
Mounting Ring
1/2" Close Nipple
Faceplate
Foam
Gasket
Red
Black
Red
Z3
R
Black
5
8 9 10 11
R4 R7
CR
R9
2
R8
6 7
R 2
Z2
4 5
1 2 3
LDB-3
Control Module
Weatherproof
Box
Page 3
Z3
Z2
R8
CR
2.75”
(2) #8-32 x 2 1/2 Phillips
Head Self Tapping Screws (included)
(2) #10-32 x 5/8
Phillips Head Self
Tapping Screws
(included)
Strobe Light
(included)
B. Front Mounting Without Weatherproof Box
The BLK-3-EWP Strobe Light Kit may be mounted with­out using the included weatherproof box. To mount the strobe light from the front, use the diagram below.
To mount the strobe light from the rear, use the diagram below.
C. Rear Mounting Without Weatherproof Box
PPrrooggrraammmmiinng
g
Strobe Light
(included)
Wall, post, etc.
2. Loop/Off-hook Indication Only
The LDB-3 control module must be placed between the phone line and the phone/terminal device to be monitored. Connect the incoming line to the red and green wires with the yellow stripe and connect the phone/terminal device to the brown and gray wires as shown.
3. Both Ring and Loop/Off-hook Indication
If the application requires ring and loop/off-hook indication, the LDB-3 control module must be placed between the phone line and the phone/terminal device to be monitored. Connect the incoming line to the red and green wires with the yellow stripe, con­nect the phone/terminal device to the brown and gray wires.
1. Ring Indication Only
Connect the incoming line to the red and green wires with the yellow stripe as shown in the diagram. No phone/terminal device is required. The LDB-3 control module can monitor for ringing any place along the ringing line.
B. Configuring for Ring and/or Loop/Off-Hook Indication
A. DIP Switches
Sw 1
ON
OFF
ON
Sw 3
OFF
ON
ON
Description
Ring Detection Only (see section B).
Off-Hook/Loop Current Detection Only (see section B).
Ring and Off-Hook/Loop Current Detection (see section B).
Sw 2
ON
OFF
Ring Cadence Mode (see section C)
Ring Cadence Mode ON - relay remains activated in between rings.
Ring Cadence Mode OFF - relay is activated only during ringing.
Red
Black
To LDB-3
Control
Module
(included)
Red
Black
To LDB-3
Control Module
(included)
Z3
Z2
R4 R7 R9 R8
CR
* Note: The gel-filled (water tight) butt connectors are designed for insulation displacement. Do not strip wires prior to terminating.
Note: The phone and incoming line connec­tions are NOT polarity sensitive.
C. Ring Cadence Mode
DIP switch 2 is used for switching between different ring detection modes. In the OFF position, the relay and switched 12VDC output will activate only while ring voltage is present and will turn off between rings. In the ON position, the relay and switched 12VDC output will remain on for up to 5.75 seconds after the ringing has stopped. This allows the relay and 12VDC (flashing strobe light) to remain on between rings of a standard ring cadence. Note: To use the Ring
Cadence Mode, ring detection MUST be enabled (DIP switch 1 - ON).
ON
1 2 3
Z3
R4 R7 R9 R8
Z2
120V AC
12V DC
Adapter
Included
Incoming
Analog
Phone Line
Phone or
Terminal Device
(not included)
* Gel-Filled Butt
Connectors (included)
Black
Black with
White stripe
Yellow stripe
Red with
Black stripe
Black with
White stripe
Red with
Green with
Yellow stripe
Brown
Gray
LDB-3 Control Module
(included)
R4R4R7R7R9R9R8
Z2
2
1 2 3 4 5 6 7 8 9 10 11
Blue
Z3
CR
R
2
5
R
Blue
Disable Feature (see
Programming section F)
Rear View of the
Strobe Light (included)
* Gel-Filled Butt
Connectors
(included)
Red (+)
Orange
Purple
Yellow
Red (+)
Black (-)Black (-)
N.C. COM. N.O.
Auxiliary
Contact Output
R
5
CR
2
R 2
1 2 3 4 5 6 7 8 9 10 11
Page 4
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.
Fax Back Doc 653
ZF301700 Rev A
Printed in the U.S.A.
OOppeerraattiioon
n
When the LDB-3 control module detects an incoming ring signal, it activates a set of normally open or normally closed contacts and turns on the 12VDC output for activating the provided strobe light. With the Ring Cadence mode off (DIP switch 2 OFF), the relay will activate and the strobe light will flash only during ringing. With the Ring Cadence mode ON (DIP switch 2 ON), the relay will remain activated and the strobe light will remain flashing between rings.
A. Ring Indication (DIP Switch 1 ON)
When the LDB-3 control module detects an off-hook condition (loop current) on the brown and gray wires, it activates a set of normally open or normally closed contacts and turns on the 12VDC output for activating the provided strobe light. The relay contacts will remain activated and the blue strobe light will flash during the off-hook condition and will stop flashing approximately 3 seconds after the phone/terminal device on the brown and gray wires is back on-hook.
B. Off-Hook Indication (DIP Switch 3 ON)
OOtthheerrAApppplliiccaattiioonns
s
PPrroodduuccttSSuuppppoorrttLLiinnee......771155..338866..8866666
6
FFaaxxBBaacckkLLiinnee......771155..338866..4433445
5
Mounting the BLK-3-EWP with the E-1600-20A
Step 1. Drill or use a knockout punch to provide a .875” diameter hole in the top of the VE-5x5.
Step 2. Make all conduit connections.
Step 3. Make all wire connections to the LDB-3 control module.
Step 4. Install the E-1600-20A as explained in its Technical Practice, Fax Back Document 215.
The BLK-3-EWP can be used in conjunction with the E-1600-20A Two-Button Emergency Phone as shown to the far right, however, special installation and mounting is required. Please follow the steps below when using the BLK-3-EWP in conjunction with a surface-mounted E-1600-20A. A VE-5x5 surface-mount box is required.
E-1600-20A and VE-5x5
(not included)
F. Disable Feature
By connecting the Disable/Info Switch input of the LDB-3 control mod­ule to the “Info” switch of Viking’s E-1600-20A, E-1600-20A-EWP, E- 1600-52A or E-1600-52A-EWP Emergency Phone, any outbound call initiated from the “Info” button will not activate the strobe light. This way, only the “Help/Emergency” outbound calls will activate the relay. Cut one of the “Info” switch wires in half and connect each end to the blue wires on the LDB-3 control module as shown in the diagram at the right. Note: This Disable input is NOT polarity sensitive.
The “Disable” input can be connected to a switch for remotely dis­abling/turning off the device (strobe light, camera, etc.) controlled by the LDB-3. For more information, retrieve Fax Back Document 866.
Z3
Z2
R4
R7
R9
R8
CR
?
Need More Information on the VE-5x5?
Call (715) 386-4345 and select 424.
D. Relay Contacts
Normally open and normally closed relay contacts are available on the orange, purple and yellow wires. The contacts are rated at .5A @ 125VAC/1A @ 30VDC. If contacts are driving an inductive load, place a suppression device at the load to snub high voltage spikes.
E. Switched 12V DC Output
The switched 12V DC output is a low current, 12-15VDC output that is turned on only while the ring/loop detect relay is activated. This switched power output is ideal for lighting the included strobe light or providing 12-15V DC power to any device that draws less than 350mAmps. The positive side is available on the red wire, and the negative side is on the black wire. Once all the line and load connections have been made, plug in the 115 V AC wall adapter, and replace the cover.
Rear View of E-1600-20A
Model: xxxxxxx P/N: xxxxxxx S/N: XXXXXX
Viking Electronics, Inc. (715)386-8861 1531 Industrial St., Hudson, WI 54016
VIKING
Control Module
1 2 3 4 5 6 7 8 9 10 11
Blue
Blue
Gel-Filled Butt
Connectors (included)
LDB-3
2 R
2
CR
5 R
Z2
R8 R9 R7 R4
Z3
1/2" Liquid Tight
Conduit Connector
1/2" PVC Conduit
1/2" Liquid Tight
Conduit
1/2" Liquid Tight
Conduit Connector
Straps