•ViewZ USA All rights reserved. Reproduction or duplication, w ithout permission of ViewZ USA of edition or contents in whole in part, any
manner, is prohibited.
•Specifications and design are subject to change without notice
Contents
VZ-CSP Installation
Packing list and info3
Setup Calibraon Program4
Interface Cable Connecon with x-rite EODIS3 / PC and ViewZ Broadcast Monitor6
Color Calibraon Step8
PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS MUST BE READ AND COMPLETELY UNDERSTOOD. KEEP THESE
INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION FOR FUTURE REFERENCE.
Proper installaon procedure by a qualied technician must be followed, as outlined in these installaon instrucons. Failure to do so could result
in property damage, or operaonal failure.
Safety measures must be pracced at all mes during the assembly and installaon of this product. Use proper safety equipment and tools for the
assembly procedure to prevent injury or product damage.
ViewZ USA does not warrant against damage caused by the use of any ViewZ USA product for purposes other than those for which it was designed.
Damage caused by unauthorized use or modicaons, 3rd party calibraon programs or hardware.
Changes or modicaons not expressly approved by ViewZ will void the warranty.
If the VZ-CSP interface cable does not securely aach to the device, the VZ-CSP program will not work correctly. Make sure you store the VZ-CSP
soware CD or Flash Memory and interface cables in a secure locaon.
Using replacement parts, soware and other broadcast monitors, not authorized by ViewZ may void the warranty.
Be aware of the calibraon environment. If using 3rd party interface cables with the VZ-CSP soware, you may void the warranty or product
may not work properly. If a ViewZ broadcast monitor gets damage caused by 3rd party interface cables or calibraon programs, ViewZ releases
responsibility.
Avoid contact with water, high humidity, re or electronic shock during the installaon and use of the VZ-CSP program
Contact ViewZ with any quesons:
(888) 998-4399
techsupport@viewzusa.com
2Installation InstructionsVisit the ViewZ USA website at http://www.viewzusa.com
VZ-CSP Installation
Calibration Software Package Info
This package is designed to calibrate all ViewZ Broadcast monitors using per-qualied calibrators.
• Part #
VZ-CSP
ViewZ Calibraon Soware Package
Compatible Calibrator List with VZ-CSP
The following calibrator is veried by ViewZ. Other calibrator may not work correctly.
• Part #• Part #
x-rite i1 EODIS3 Klein Instrument K10-A
In the box
Your VZ-CSP product is shipped with an installaon USB Drive and interface cable. If there are parts missing
and/or damaged, please contact ViewZ USA at (888)-998-4399.
q Soware USB Flash
memory drive
q
q USB to Serial Converter with
22" Cable (1 pc.)
w Serial to RJ45 Converter
with 33" Cable (1 pc.)
Required items for installation
Your VZ-CSP product is only cered with the x-rite i1 or
and ViewZ Broadcast Monitors.
®
Window 7 PC - 64bitViewZ Broadcast Monitorx-rite i1 or Klein Instrument K10-A
w
Klein Instrument K10-A, running Window 7 64 bit OS computer
3Installation InstructionsVisit the ViewZ USA website at http://www.viewzusa.com
Installation
Program Setup
1) VZ-CSP requires MS Framework 4.0.
2) If your computer does not have MS Framework 4 or above installed,
please install a copy. A copy of MS Framework is included on Your CD
3) Require to Install MS Framework before installation VZ-CSP software.
To install MS Framework
1) Open the 'Install(XP)' folder
2) Double click 'dotNetFx40_Full_x86_x64.exe' to install MS
Framework.
VZ-CSP Installation
Double Click to run
Click to run
This soware is for Windows PC only. If you need to install
on MAC OS or have a problem installing this soware,
please contact ViewZ USA at (888)-998-4399 or contact a
ViewZ authorized reseller.
Installaon failure of MS Framework is usually caused by
an unstable or limited PC funcon or resources.
Compatible with
Window OS 64bit
4Installation InstructionsVisit the ViewZ USA website at http://www.viewzusa.com
VZ-CSP Installation
Installation
Program Setup
1) Once your computer has Microsoft .NET Framework 4.0 installed.
Now install the 'vcredist_x86.exe'.
2) Double click 'vcredist_x86.exe' file.
3) Follow install instructions.
Double Click to run
Click to run
This soware is for Windows PC only. If you need to install
on MAC OS or have a problem installing this soware,
please contact ViewZ USA at (888)-998-4399 or contact a
ViewZ authorized reseller.
Installaon failure of MS Framework is usually caused by
an unstable or limited PC funcon or resources.
Compatible with
Window OS 64bit
5Installation InstructionsVisit the ViewZ USA website at http://www.viewzusa.com
Installation
Calibrator Connection x-rite i1
1) Connect x-rite i1 or Klein Instrument K10-A to your PC
Do not turn on ViewZ Broadcast monitor unl soware
and interface cables are fully installed.
VZ-CSP Installation
Connect via USB or any supported type
2) Connect VZ-CSP interface cable
3) Attach your x-rite i1 or Klein Instrument K10-A to your ViewZ
Broadcast Monitor
USB to Serial Converter
Serial to RJ45
6Installation InstructionsVisit the ViewZ USA website at http://www.viewzusa.com
VZ-CSP Installation
Installation
Calibrator Connection
4) Follow the Color meter installation instructions.
Do not turn on ViewZ Broadcast monitor unl you have
completed the previous setup instrucons.
5) Adjust the position of the counter weight according to the size of your
display. Be sure the foam pad on the front of the device sits flat on
your display.
x-rite i1
7Installation InstructionsVisit the ViewZ USA website at http://www.viewzusa.com
Color Calibration
Calibration x-rite i1
1) Open the CD or Flash Memory root folder, and run 'Orion CMS.exe'
file as administrator.
Make sure all cables are rmly connected.
VZ-CSP Installation
2) Port number is for ViewZ Monitor
Name of the probe connected to the monitor and computer
Port Number Name of Probe
8Installation InstructionsVisit the ViewZ USA website at http://www.viewzusa.com
VZ-CSP Installation
Color Calibration
3) Select 'Tool / Setting'
x-rite i1Calibration
Always use the same brightness for 3200K, D65, D93
(refer to the table below)
Colorimeter Calibraon values depends on the ViewZ
Broadcasng Monitor model (refer to the table below)
ViewZ ModelBrightness ValueColorimeter Calibration Name
VZ-215LED-SN
VZ-090PM-P / VZ-090RM-P
VZ-185PM-P / VZ-185RM-P
VZ-215PM-P
130cd
150cd
110cd
110cd
LM215WF4-TLG1
AA090AA01
LC185EXN
LM215WF3-SLC5
VZ-240PM-P120cdLM240WU8_SLD2
VZ-240PM-PL120cdLM240WU9SLA1
VZ-460PM-P120cdLTI460HN08
9Installation InstructionsVisit the ViewZ USA website at http://www.viewzusa.com
Color Calibration
Calibration x-rite i1
Below two pictures show program setup for VZ-240PM-P
model calibraon
VZ-CSP Installation
q
w
e
1. Select 120cd for 3200K, D65, and D90
2. Select LM240WU9SLA1 for Colorimeter Calibraon. Then,
press OK
3. When all items are selected the correct probe name will
show colorimeter calibraon name on right boom corner.
And Sengs window will disappear.
This indicator value is changing from 'Default' to 'selected Colorimeter'
10Installation InstructionsVisit the ViewZ USA website at http://www.viewzusa.com
VZ-CSP Installation
Color Calibration
4) Click Calibrate button to start calibration.
Calibration report will pop up when it is complete.
x-rite i1Calibration
q
e
1) Aer selecon of all opon, click 'Calibrate' buon to start
w
2) Program will check the Panel Gamut
r
3) Above picture shows Panel Gamut and White Point Measure values
4) Complete. Just double check the Colorimeter info of Calibraon
report (pop-up) and CMS Program's info.
11Installation InstructionsVisit the ViewZ USA website at http://www.viewzusa.com
VZ-CSP Installation
Warranty
ViewZ USA
LIMITED WARRANTY
What and Who is Covered by this Limited Warranty and for How Long
ViewZ USA warrants this product to be free from defects in material and workmanship for the original owner of this product. The
limited warranty is valid only for the original purchaser of the product.
What ViewZ USA Will Do
At the sole opon of ViewZ USA, ViewZ USA will repair or replace any product or product part that is defecve. If ViewZ USA chooses
to replace a defecve product or part, a replacement product or part will be shipped to you at no charge, but you must pay any labor
costs.
What is Not Covered; Limitaons
ViewZ USA DISCLAIMS ANY LIABILITY FOR DAMAGE TO MOUNTS, ADAPTERS, DISPLAYS, PROJECTORS, OTHER PROPERTY, OR
PERSONAL INJURY RESULTING, IN WHOLE OR IN PART, FROM IMPROPER INSTALLATION, MODIFICATION, USE ALTERNATIVE
SOFTWARE, USE 3RD PARTY TOOLS, USE 3RD PARTY SOFTWARE, USE OR MISUSE OF ITS PRODUCTS.
ViewZ USA DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE. ViewZ USA IS NOT RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT
NOT LIMITED TO, INABILITY TO USE ITS PRODUCTS OR LABOR COSTS FOR REMOVING AND REPLACING DEFECTIVE PRODUCTS OR
PARTS. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE
ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
What Customers Must Do for Limited Warranty Service
If you discover a problem that you think may be covered by the warranty you MUST REPORT it in wring to the address below within
thirty (30) days. Proof of purchase (an original sales receipt) from the original consumer purchaser must accompany all warranty
claims. Warranty claims must also include a descripon of the problem, the purchaser’s name, address, and telephone number.
General inquiries can be addressed to ViewZ USA Customer Service at 1-888-998-4399. Warranty claims will not be accepted over the
phone or by fax.
ViewZ USA
An: Warranty Claim
177 W. Orangethorpe Ave.
Placena, CA 92870
How State Law Applies
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
Disclaimer
ViewZ USA intends to make this manual accurate and complete. However, ViewZ USA makes no claim that the informaon contained
herein covers all details, condions or variaons, nor does it provide for every possible conngency in connecon with the
installaon or use of this product. The informaon contained in this document is subject to change without noce or obligaon of
any kind. ViewZ USA makes no representaon of warranty, expressed or implied, regarding the informaon contained herein. ViewZ
USA assumes no responsibility for accuracy, completeness or suciency of the informaon contained in this document.
Contact Us
NORTH AMERICA
177 W. Orangethorpe Ave.
Placena, CA 92870
USA and Canada
Phone: 1-888-998-4399
Fax: 1-714-996-1138
Other Locaons
Phone: (001) 888-998-4399