1.4.5 OSD FUNCTION TEST:
A. Timing: 640*480 @75Hz.
B. Pattern: “GENERAL-1”.
C. Make sure that Each FUNCTION have one right action.
D. After adjusting and confirming no error, we can take delivery of goods until it set as
default.
1.4.6 Under PC MODE, input PC AUDIO signal, determines whether the action of AUDIO IN is
right. Meets earphone with the EARPHONE, Determined whether the action of AUDIO
OUT is normal.
SET CONTENT CHECK
CHANNEL
ORDER
FREQUENCE
(MHz)
Broadcasting
System
PATTERN SOUND P/S(dB) CONTENT
P0
45.75 PAL I Mono Scope FM Mono
(Sweep Tone)
-5 Mechanical
electrical unusual
sound
P1
55.75 SECAM L Color Bar Nicam
Stereo*2
-16 image to sound
disturbance
P2
160.00 SECAM L Mono scope FM Mono*1
(400Hz)
-16 NOISE LIMITED
SENSITIVIY
P3
440.25 PAL D/K Full White
100%
Nicam
Stereo*2
-10 sound image
brightness effect
P4
471.25 PAL B/G Dem Nicam
Stereo*2
-10 Stereo Function
P5
567.25 PAL I Multi-Burst Nicam Dual -10 Dual Function
P6
855.25 PALB/G Color Bar Nicam
Stereo*2
-16 Mechanical
electrical unusual
sound
P7
863.25 PAL D/K Mono Scope FM Mono*1
(400Hz)
-16 NOISE LIMITED
SENSITIVIY
Chart 2
Note: 1. Sound working pattern: Int Osc 400Hz;
Sound modulation: standard.
2. Stereo content setting: Left sound track 3KHz; Right sound track 1KHz.
1.4.7.TV RECEIVING TEST:
P0. Examines sound by ear, whether the sound does have mechanical resonation and the
electrical unusual sound, and image to sound disturbance.
P1. Examines whether the sound does receive the image disturbance, Judgment basis:
Whether there is unusual sound, input signal LEVEL<=36dBu,and STEREO
SENSITIVITY is normal.
P2. Adjustment attenuator, If the critical point of the change of the image signal to noise
ratio is under LEVEL<=60dBu,regards as normally.
P3. Examines TV brightness; confirm whether DUAL FUNCTION is normal under DUAL
MODE: whether DUAL SENSITIVITY is normal when input signal is under
LEVEL<=36dBu.
P4. Examines whether PAL color demodulation is normal by using DEM image; whether
STEREO SENSITIVITY is normal when input signal is under LEVEL<=36dBu.
P5. Examines whether DUAL FUNCTION is normal under DUAL MODE; whether
DUAL SENSITIVITY is normal when input signal is under LEVEL<=36dBu.
P6. Examines whether the sound does receive the image disturbance, Judgment basis:
Whether there is unusual sound, input signal LEVEL<=36dBu,and STEREO
SENSITIVITY is normal.
P7. Adjustment attenuator, If the critical point of the change of the image signal to noise
ratio is under LEVEL<=60dBu,regards as normally.
11
ViewSonic Corporation Confidential
-
Do Not Copy N3250w-G