Viessmann VITOROND 200, VD2-320, VD2-380, VD2-440, VD2-500 Technical Data Manual

...
VVVVIIIITTTTOOOORRRROOOONNNNDDDD 222200000000
Triple-pass hot water heating boiler
1255 to 4387 MBH / 368 to 1285 kW
Product may not be exactly as illustrated.
Technical Data Manual
Model Nos. and pricing: see Price List
Vitorond 200
Oil-/Gas-fired boiler
sectional cast iron design with Eutectoplex heat transfer surface, in triple-pass design for operation with modulating water temperatures Heating input: 1255 to 4387 MBH
368 to 1285 kW
5285428v1.607/201
0
Product Information
2 VITOROND 200, VD2
VITOROND 200
The modular sectional cast iron design of the Vitorond 200, VD2 allows for problem-free transport into difficult-to-access boiler rooms and permits easy assembly. The triple-pass design ensures clean, low-emission combustion, while the Eutectoplex heat exchanger surface guarantees economical energy consumption, high operational reliability and a long service life.
The benefits at a glance:
H Eutectoplex heat exchanger surface for high
operational reliability and a long service life. The homogeneous structure of the Eutectoplex special gray cast iron ensures uniform heat transfer, minimizing stress fractures and counteracting the formation of condensate. Shape and geometry of the cast iron sections, excellent water flow characteristics and uniform temperature distribution further increase the level of operational reliability.
H Problem-free transport into
difficult-to-access boiler rooms due to sectional construction and low weight of individual sections.
H Efficient and environmentally friendly
operation due to modulated boiler water temperatures. Combustion efficiency up to:
- oil 88.1%
. . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
- gas 85.5%. . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Thermal efficiency up to:
- oil 88.0%. . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
- gas 85.4%. . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Low-emission combustion through
triple-pass design.
H Simple, quick assembly of the individual
cast iron sections is achieved with a double-groove seal fit system for the flue gas passageways. The gasket seal is secured in place by the double groove, and therefore not subject to mechanical stresses.
H Problem-free cleaning access facilitated by
a hinged (left or right) swing-open combustion chamber door, allowing easy access to all three heat exchanger passes from boiler front, reducing side clearance.
H Economical and safe operation of the
heating system with Vitotronic or Dekamatik digital boiler and heating system control. Tailored to every requirement, this control covers all known control strategies and applications.
H Economical and hygienic DHW production
with indirect-fired Vitocell 100 steel or Vitocell 300 stainless steel tanks. Tanks may be combined into multiple-tank batteries for applications requiring larger quantities of hot water.
528
542
8
v1.
6
Product Information
Cut-Away Section
Product may not be exactly as illustrated.Product may not be exactly as illustrated.
VITOROND 200, VD2 3
Extremely effective Second Combustion Vitotronic 300 control ­4” / 100 mm thick pass chamber intelligent and easy to install, insulation operate and service
Third Eutectoplex heat Wide water Burner door pass exchanger surface passageways insulation
constructed from homogeneous special gray cast iron
5
2
8
5
4
2
8
v
1
.
6
Technical Data
4 VITOROND 200, VD2
Technical data
*1
Boiler model VD2- 320 380 440 500 560 630 700 780 860 950 1080
Input (oil)
*1
MBH 1255 1490 1726 1961 2196 2471 2745 3059 3373 3727 4236
kW 368 436 506 574 643 724 804 896 988 1091 1241
Input (gas)
*1
MBH 1300 1544 1787 2031 2275 2559 2843 3168 3493 3860 4387 kW 381 452 523 595 666 750 833 928 1023 1130 1285
Output (oil/gas)
*2
MBH 1110 1319 1526 1732 1941 2183 2425 2699 2976 3288 3738
kW 325 387 447 508 569 640 711 791 872 963 1095
Combustion efficiency (oil) % 88.1 88.0 88.0 87.9 87.8 87.8 87.7 87.6 87.5 87.4 87.3 Combustion efficiency (gas) % 85.5 85.4 85.4 85.3 85.2 85.1 85.1 85.0 84.9 84.8 84.6
Thermal efficiency (oil) % 88.0 88.0 88.0 88.0 88.0 87.9 87.9 87.9 87.9 87.8 87.8 Thermal efficiency (gas) % 85.4 85.4 85.4 85.3 85.3 85.3 85.3 85.2 85.2 85.2 85.2 Number of cast iron sections 9 10 11 12 13 14 15 16 17 18 19
Cast iron block dimensions
Length
Width
Height
inches mm inches mm inches mm
57
1450
40½
1030
45¼
1150
62
1580
40½
1030
45¼
1150
67
1710
40½
1030
45¼
1150
72
1840
40½
1030
45¼
1150
77½
1970
40½
1030
45¼
1150
82½
2100
40½
1030
45¼
1150
88
2230
40½
1030
45¼
1150
93
2360
40½
1030
45¼
1150
98
2490
40½
1030
45¼
1150
103
2620
40½
1030
45¼
1150
108
2750
40½
1030
45¼
1150
Cast iron section dimensions
Front section (with combustion chamber door)
Intermediate section
Rear section (with flue gas collar)
inches mm inches mm inches mm
45¼ x 40½ x 10¾ 1150 x 1030 x 270
45¼ x 36¼ x 5
1150 x 920 x 125
45¼ x 36¼ x 9
1150 x 920 x 290
Dimensions (with insul. jacket)
Total length
Total width with NR2 control (side-mounted)
Total width with Dekamatik (side-mounted)
Total width with KR control (side-mounted)
Total height
inches mm
inches mm
inches mm
inches mm
inches mm
58¾
1490
49¼
1250
52¾
1340
54¾
1390
50¾
1290
63¾
1620
49¼
1250
52¾
1340
54¾
1390
50¾
1290
68¾
1750
49¼
1250
52¾
1340
54¾
1390
50¾
1290
73¾
1870
49¼
1250
52¾
1340
54¾
1390
50¾
1290
78¾
2000
49¼
1250
52¾
1340
54¾
1390
50¾
1290
83¾
2130
49¼
1250
52¾
1340
54¾
1390
50¾
1290
89
2260
49¼
1250
52¾
1340
54¾
1390
50¾
1290
93¾
2380
49¼
1250
52¾
1340
54¾
1390
50¾
1290
98¾
2510
49¼
1250
52¾
1340
54¾
1390
50¾
1290
104
2640
49¼
1250
52¾
1340
54¾
1390
50¾
1290
108¾
2760
49¼
1250
52¾
1340
54¾
1390
50¾
1290
Weight
Front section (with combustion chamber door)
Intermediate section
Rear section (with flue gas collar) Cast iron heat exchanger block
Overall weight
complete with insulation
lbs kg lbs kg lbs kg lbs kg
lbs kg
529 240 353 160 507
230 3748 1700
3924 1780
529 240 353 160 507
230 4100 1860
4299 1950
529 240 353 160 507
230 4453 2020
4652 2110
529 240 353 160 507
230 4762 2160
4982 2260
529 240 353 160 507
230 5115 2320
5335 2420
529 240 353 160 507
230 5423 2460
5666 2570
529 240 353 160 507
230 5776 2620
6019 2730
529 240 353 160 507
230 6085 2760
6349 2880
529 240 353 160 507
230 6437 2920
6702 3040
529 240 353 160 507
230 6790 3080
7070 3210
529 240 353 160 507
230 7143 3240
7429 3370
*1
Input ratings are based on ANSI Z21.13a*CSA 4.9a-2005 - Gas Fired Steam and Hot Water Boilers; CSA B140.7-05 - Oil Burning Equipment - Steam and Hot Water Boilers; CSA B140.0-03 - Oil Burning Equipment - General Requirements; UL 726 - 7th ed. - Oil-Fired Boiler Assemblies; and UL 795 - Commercial Industrial Gas Heating Equipment.
*2
Output ratings are based on the IBR BTS-2000
method to determine efficiency of commercial space heating boilers”.
528
542
8
v1.
6
Technical Data
VITOROND 200, VD2 5
Technical data
Boiler model VD2- 320 380 440 500 560 630 700 780 860 950 1080
Boiler water content USG
ltr
65
24773275803038733195359
102 387
110 415
117 443
124 471
132 499
139 527
Max. boiler temperature
*2
(= fixed high limit)
°F °C
248 120
248 120
248 120
248 120
248 120
248 120
248 120
248 120
248 120
248 120
248 120
Max. allow. operating pressure
*3
psig 75 75 75 75 75 75 75 75 75 75 75
Boiler connections
Boiler supply and return Safety supply
*4
Safety return
*4
Drain valve
inches inches inches inches
4 2½ 2½
¾
4 2½ 2½
¾
4 2½ 2½
¾
4 2½ 2½
¾
4 2½ 2½
¾
4 2½ 2½
¾
4 2½ 2½
¾
4 2½ 2½
¾
4 2½ 2½
¾
4 2½ 2½
¾
4 2½ 2½
¾
Heating surface area
Flue gas side ft.
2
m
2
170
15.8
196
18.2
212
19.7
232
21.5
254
23.6
274
25.5
296
27.5
317
29.5
339
31.5
358
33.3
380
35.3
Water side ft.
2
m
2
98
9.1
109
10.1
120½
11.2
131
12.2
142
13.2
153
14.2
165
15.3
175
16.3
187
17.4
198
18.4
209
19.4
Flue gas
*5
– Temperature (gross)
*6
– Flue gas mass flow rate
With minimum heating input and a 2-stage burner (operation of stage 1) – Temperature
– Flue gas mass flow rate at
minimum input rate
°F °C lbs/h kg/h
°F °C lbs/h kg/h
374 190
1301
590
266 130 710 322
374 190
1598
725
266 130 842 382
374 190
1854
841
266 130 974 442
374 190
2081
944
266 130
1109
503
374
190 2337 1060
266
130 1241
563
374
190 2601 1180
266
130 1398
634
374
190 2897 1314
266
130 1552
704
374
190 3196 1450
266
130 1730
785
374
190 3527 1600
266
130 1907
865
383
195 3825 1735
275
135 2110
957
383
195 4277 1940
275
135 2394 1086
Boiler standby loss based on max. heating input and hot water supply and return temperatures of 167 / 140°F
75 / 60 °C
% 0.40 0.38 0.35 0.32 0.31 0.29 0.28 0.27 0.26 0.25 0.24
Vent pipe collar outer
*7
in mm
12
30012300123001230012300123001230012300123001230012300
Flue gas resistance “w.c. 0.20 0.35 0.51 0.67 0.75 0.83 1.10 1.54 1.93 1.77 2.28
- at upper end of rated input mbar 0.5 0.9 1.3 1.7 1.9 2.1 2.8 3.9 4.9 4.5 5.8
Required flue draft
Category I
Pa “w.c.
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
Positive pressure
Category III
Pa “w.c.200.08200.08200.08200.08200.08200.08200.08200.08200.08200.08200.08
*1
Inch dimensions are rounded to the nearest ¼”.
*2
The maximum supply operating temperature (= max. adjustable high limit) lies approx. 27°F / 15°C below the fixed high limit setting.
*3
May be less in some Canadian provinces.
*4
Connections for boiler connection kit (standard equipment).
*5
Combustion results are based on 13.0% CO2with fuel oil #2 and 10% CO2with natural gas, as well as a system supply temperature of 167 °F / 75 °C, and a system return temperature of 140 °F / 60 °C.
*6
Measured flue gas temperature with a combustion air temperature of 68 °F / 20 °C and a boiler water temperature of 176 °F / 80 °C.
*7
Vent pipe collar diameter does not automatically indicate vent/chimney size. See page 13 for details.
"
The combustion burner head material must be suitable for temperatures of at least 932 °F / 500 °C.
"
Vitorond 200, VD2-950 and VD2-1080 boiler sizes have unique characteristics, including differences in insulation jacket and dimensions.
"
For information regarding other Viessmann System Technology componentry, please reference documentation of respective product.
5
2
8
5
4
2
8
v
1
.
6
Loading...