Technical Data Manual
VITOTRONIC 100
Boiler control unit
for high temperature heating systems
Vitotronic 100
Model KK5, Part No. 7133 373
Boiler control
For elevated boiler water temperature operation
For heating systems with one high temperature heating
circuit (without mixing valve)
With analog boiler water temperature display
Viessmann quick-connect plug-in system
5265 489 v1.3 07/2004
Certified as a component part
of Viessmann boilers only

Product I nformation/Standard Equipment/
Application
Product Information
The benefits at a glance:
H Space heating circuit controlled by
room thermostat
H Single-stage boiler control
H Built-in boiler low temperature
protection
H Short assembly time and start-up due
to diagnostic and Rast-5 plug-in
systems
Modular structure
The control unit consists of:
system ON/OFF switch, temperature
display, pump aquastat for boiler
protection,
– adjustable high limit
(type RAK 51.1/3382, Mfg. Etheco or
type TR 97.55180.251, Mfg. EGO)
– fixed high limit
(type RAK 75.4/3412, Mfg. Etheco or
type STW 56.10525.400, Mfg. EGO)
– electronic circuit board with power
supply
– quick-connect Rast-5 plug-in system
– fixed high limit test terminals
Vitotronic 100, Model KK5
H Electronic boiler control:
– for single-boiler systems
– for heating circuits without mixing
valve
– for a single-stage burner
– with analog temperature display
Boiler-specific functions
The Vitotronic 100 controls the boiler
temperature according to heat deman d
input (room thermostat connections).
Boiler water temperature is limited
through the adjustable aquastat.
Minimum boiler water temperature
protection is achieved with the built-in
pump aquastat.
Standard Equipment
Vitotronic 100, Model KK5
(Part No. 7133 373)
with
H adjustable and fixed high limit
H built-in pump aquastat
H power supply cord
Technical data
Operating Voltage: 120 VAC
Operating Frequency: 60 Hz
Nominal Current: 6A
Power Consumption: 10 W
Certification: CSA certified
(in conjunction with
Viessmann Vitorond boiler)
Max. ambien t temperature:
– at operation: 32 to 104 ºF
0to 40ºC
(in rooms and installation sites
with normal ambient conditions)
– when storing or transporting:
–4 to +149 ºF
–20 to +65 ºC
Output rating:
– Heating circuit pump:3 FLA, 120 V
– Burner: 2 FLA, 120 V
(recycled and recyclable) paper.
Printed on environmentally friendly
Application
In conjunction with the following Viessmann boilers
Boiler Model and Series
Oil-fired hot water
heating boiler with
power burner
Viessmann Manufacturing Company (U.S.) Inc.
45 Access Road
Warwick, Rhode Island • 02886 • USA
Tel. (401) 732-0667 • Fax (401) 732-0590
www.viessmann-us.com • mail@viessmann-us.com
2
Vitorond 200
Fuel
Oil
Minimum boiler temperature protection
The minimum boiler water temperature is
selected with the adjustable pump
aquastat.
Minimum boiler water
temperature
without low
limit
with low limit
(average temp.)
104 ºF/40 ºC
Viessmann Manufacturing Company Inc.
750 McMurray Road
Waterloo, Ontario • N2V 2G5 • Canada
Tel. (519) 885-6300 • Fax (519) 885-0887