Bedienungsanleitung
Operation Manual
Bahnschranke, vollautomatisch
mit Zubehör
Level crossing, fully automatic
with accessories
H0: 5100
TT: 5700
N: 5900
Abb. Art. 5100
1. Wichtige Hinweise / Important information ........................................................ 2
2. Einleitung / Introduction ..................................................................................... 3
3. Funktionskontrolle / Function check .................................................................. 4
4. Einbau / Mounting ............................................................................................. 4
5. Anschluss / Connection ..................................................................................... 6
6. Digitale Ansteuerung / Digital control ................................................................ 6
7. Montage der Verkehrsschilder / Installing the trac signs ................................ 7
8. Technische Daten / Technical data .................................................................... 8
DC
die bewegt!
AC

DE EN
1. Wichtige Hinweise
Bitte lesen Sie vor der ersten Anwendung des
Produktes bzw. dessen Einbau diese Bedienungsanleitung aufmerksam durch. Bewahren Sie diese
auf, sie ist Teil des Produktes.
1. Important information
Please read this manual completely and attentively
before using the product for the first time. Keep this
manual. It is part of the product.
1.1 Sicherheitshinweise
Vorsicht:
Verletzungsgefahr!
Aufgrund der detaillierten Abbildung des Originals
bzw. der vorgesehenen Verwendung kann das
Produkt Spitzen, Kanten und abbruchgefährdete
Teile aufweisen. Für die Montage sind Werkzeuge nötig.
Stromschlaggefahr!
Die Anschlussdrähte niemals in eine Steckdose einführen! Verwendetes Versorgungsgerät
(Transformator, Netzteil) regelmäßig auf Schäden
überprüfen. Bei Schäden am Versorgungsgerät
dieses keinesfalls benutzen!
Alle Anschluss- und Montagearbeiten nur bei
abgeschalteter Betriebsspannung durchführen!
Ausschließlich nach VDE/EN gefertigte Modellbahntransformatoren verwenden!
Stromquellen unbedingt so absichern, dass es
bei einem Kurzschluss nicht zum Kabelbrand
kommen kann.
1.2 Das Produkt richtig verwenden
Dieses Produkt ist bestimmt:
- Zum Einbau in Modelleisenbahnanlagen und
Dioramen.
- Zum Anschluss an einen Modellbahntransformator
(z. B. Art. 5200) bzw. an eine Modellbahnsteuerung mit zugelassener Betriebsspannung.
- Zum Betrieb in trockenen Räumen.
Jeder darüber hinausgehende Gebrauch gilt als
nicht bestimmungsgemäß. Für daraus resultierende
Schäden haftet der Hersteller nicht.
1.1 Safety instructions
Caution:
Risk of injury!
Due to the detailed reproduction of the original
and the intended use, this product can have
peaks, edges and breakable parts. Tools are
required for installation.
Electrical hazard!
Never put the connecting wires into a power
socket! Regularly examine the transformer for
damage. In case of any damage, do not use the
transformer.
Make sure that the power supply is switched
off when you mount the device and connect the
cables!
Only use VDE/EN tested special model train
transformers for the power supply!
The power sources must be protected to avoid
the risk of burning cables.
1.2 Using the product for its correct purpose
This product is intended:
- For installation in model train layouts and dioramas.
- For connection to an authorized model train
transformer (e. g. item 5200) or a digital command station.
- For operation in dry rooms only.
Using the product for any other purpose is not
approved and is considered inappropriate. The
manufacturer is not responsible for any damage
resulting from the improper use of this product.
1.3 Packungsinhalt überprüfen
Kontrollieren Sie den Lieferumfang auf Vollständigkeit (siehe Tabelle und Abb. 1):
2
1.3 Checking the package contents
Check the contents of the package for completeness (see table and fig. 1):

Pos.
Bezeichnung / Description
H0 TT N
1 Bahnschranke mit Antrieb / Barrier with drive unit 2 2 2
2 Verkehrsschild mit Mast / Trac sign with mast 2 2 2
3 Andreaskreuz mit Mast / St. Andrew‘s cross with mast 2 2 2
4 Warnbake mit Mast / Beacon with mast 12 12 12
5 Rampe / Ramp 2 4 2
6 Rampenfuß / Ramp socket 4 - 7 Gleisfüllstück / 2R connector 1 1 1
8 Gleisfüllstück mit Kabel / 3R connector with cable 1 - -
9 Befestigungsring für Antrieb / Attachment ring for drive 2 2 2
10 Schrankenbaumwiderlager / Barrier support 2 2 2
11 Oberes Sockelstück für Widerlager / Upper socket part for barrier support 2 - 12 Unteres Sockelstück für Widerlager / Lower socket part for barrier support 2 - 13 Oberes Sockelstück für Schranke / Upper socket part for barrier 2 - 14 Unteres Sockelstück für Schranke / Lower socket part for barrier 2 - -
Abb. 1
10
5
1
13
14
13
H0 Art. 5100
14
2. Einleitung
2.1 Vorbild
Zur Sicherung von Bahnübergängen durch Bahnschranken wurden seit jeher Schrankenwärter
eingesetzt. Die Schranken wurden über Seilzüge
durch den Schrankenwärter fernbedient. Bis in die
heutige Zeit ist dies bei der Bahn unverändert. Allerdings werden die Schrankenwärter immer weniger,
da alle handbetätigten Bahnübergänge nach und
nach durch moderne Lichtzeichenanlagen ersetzt
werden.
11
12
11
7
1
10
12
5
6
8
Fig. 1
2. Introduction
2.1 Prototype
To secure level crossings by crossing barriers gate
keepers have been appointed in the past and even
today. These barriers are remote-operated manually by the gate keeper with cables. These level
crossings are still used today. But the gate keepers
are replaced more and more by modern traffic light
systems.