Bedienungsanleitung
Operation Manual
5549
Universal-Tasten-Stellpult,
rückmeldefähig, 2-begriffig
Universal push button panel,
feedback, 2-aspects
1. Wichtige Hinweise / Important information ................................................ 2
2. Einleitung / Introduction ............................................................................. 2
3. Einbau / Mounting ...................................................................................... 3
4. Anschluss / Connection ............................................................................. 3
5. Technische Daten / Technical data ............................................................ 3
AC
die bewegt!
DC

DE EN
1. Wichtige Hinweise
Bitte lesen Sie vor der ersten Anwendung des Produktes
bzw. dessen Einbau diese Bedienungsanleitung aufmerksam durch. Bewahren Sie diese auf, sie ist Teil des
Produktes.
1. Important information
Please read this manual completely and attentively before
using the product for the first time. Keep this manual. It is
part of the product.
1.1 Sicherheitshinweise
Vorsicht:
Verletzungsgefahr!
Für die Montage sind Werkzeuge nötig.
Stromschlaggefahr!
Die Anschlussdrähte niemals in eine Steckdose einführen! Verwendetes Versorgungsgerät (Transformator,
Netzteil) regelmäßig auf Schäden überprüfen. Bei Schäden am Versorgungsgerät dieses keinesfalls benutzen!
Alle Anschluss- und Montagearbeiten nur bei abgeschal
teter Betriebsspannung durchführen!
Ausschließlich nach VDE/EN gefertigte Modellbahntransformatoren verwenden!
Stromquellen unbedingt so absichern, dass es bei einem
Kurzschluss nicht zum Kabelbrand kommen kann.
-
1.2 Das Produkt richtig verwenden
Dieses Produkt ist bestimmt:
- Zum Einbau in Modelleisenbahnanlagen und Dioramen.
- Zum Anschluss an einen Modellbahntransformator
(z. B. Art. 5200) bzw. an eine Modellbahnsteuerung mit
zugelassener Betriebsspannung.
- Zum Betrieb in trockenen Räumen.
Jeder darüber hinausgehende Gebrauch gilt als nicht bestimmungsgemäß. Für daraus resultierende Schäden haftet
der Hersteller nicht.
1.3 Packungsinhalt überprüfen
Kontrollieren Sie den Lieferumfang auf Vollständigkeit:
- Universal-Tasten-Stellpult
- Beutel mit Zubehör
- Etiketten
- Anleitung
1.1 Safety instructions
Caution:
Risk of injury!
Tools are required for installation.
Electrical hazard!
Never put the connecting wires into a power socket!
Regularly examine the transformer for damage. In case
of any damage, do not use the transformer.
Make sure that the power supply is switched off when
you mount the device and connect the cables!
Only use VDE/EN tested special model train transformers for the power supply!
The power sources must be protected to avoid the risk
of burning cables.
1.2 Using the product for its correct purpose
This product is intended:
- For installation in model train layouts and dioramas.
- For connection to an authorized model train transformer
(e. g. item 5200) or a digital command station.
- For operation in dry rooms only.
Using the product for any other purpose is not approved
and is considered inappropriate. The manufacturer is not
responsible for any damage resulting from the improper
use of this product.
1.3 Checking the package contents
Check the contents of the package for completeness:
- Universal push button panel
- Bag with accessories
- Decal
- Manual
2. Einleitung
Das Universal-Tasten-Stellpult mit Rückmeldung besitzt 8
separate Momenttaster in 4 Gruppen. Jede Gruppe besitzt
2 Tasten sowie eine rote und eine grüne Leuchtdiode zur
Rückmeldung der Stellung von Weichen und Signalen.
Die Rückmeldefunktion des Universal-Tasten-Stellpultes
kann nur genutzt werden, wenn die zu schaltenden Antriebe und damit deren Spulenantriebe eine mechanische
Endabschaltung aufweisen. Dazu gehören neuere Weichenantriebe der Firmen Fleischmann, Roco, Märklin, die
Viessmann Formsignale (nicht für Digital-Formsignale) und
das Viessmann Universal-Relais 1 x 4UM Art. 5551.
Die rückmeldefähigen Stellpulte können nicht für folgende
Artikel verwendet werden:
2
2. Introduction
The universal push button panel with feedback has 8
separate momentary contacts and feedback LEDs (red
and green) to display the aspect of semaphores or the
position of turnouts.
You can only use the feedback function of the push button
panel if the drives to be switched and thus their coil drives
have a mechanical end switch. This includes the latest point
drives from Fleischmann, Roco, Märklin, the Viessmann
semaphore signals (not the digital semaphore signals) and
the Viessmann universal relay 1 x 4UM item 5551.
The push button panels with feedback cannot be used for
the following articles: