Installation instructions
for contractors
VIESMANN
Vitosol-F
Type SV and SH
Flat-plate collector for elevated installation
VITOSOL-F
5675 789 GB 2/2015
Dispose after installation.
![](/html/27/2713/2713b1b959c20126e86e3349c669d7a050ad9599e2930db60c00fe9f162e457f/bg2.png)
2
Please follow these safety instructions closely to
prevent accidents and material losses.
Safety instructions explained
!
Please note
This symbol warns against the risk of material
losses and environmental pollution.
Note
Details identified by the word "Note" contain additional
information.
Target group
These instructions are exclusively intended for authorised contractors.
Regulations to be observed
■
National installation regulations
■
Statutory regulations for the prevention of accidents
■
Statutory regulations for environmental protection
■
Codes of practice of the relevant trade associations
■
All relevant safety regulations as defined by DIN, EN,
DVGW, VDE and locally applicable standards
a
ÖNORM, EN and ÖVE
c
SEV, SUVA, SVTI, SWKI and SVGW
Safety instructions
5675 789 GB
![](/html/27/2713/2713b1b959c20126e86e3349c669d7a050ad9599e2930db60c00fe9f162e457f/bg3.png)
3
1. Information Symbols ................................................................................................. 4
Intended use .......................................................................................... 4
Product information ................................................................................ 5
■
Collector support, standard kit and collector kit extension ................. 5
■
Retaining rail 6 for 1 collector ........................................................... 5
■
Retaining rail 7 for 2 collectors ......................................................... 6
■
Cross brace ........................................................................................ 6
■
Installation aid template ...................................................................... 6
2. Installation sequence Determining collector row clearance z ................................................... 8
Fitting the collector supports .................................................................. 8
Installing the cross braces ..................................................................... 10
Installing the collectors .......................................................................... 10
Connecting the collectors ...................................................................... 12
Installation .............................................................................................. 14
3. Commissioning .................................................................................................................. 16
Index
5675 789 GB
![](/html/27/2713/2713b1b959c20126e86e3349c669d7a050ad9599e2930db60c00fe9f162e457f/bg4.png)
4
Symbol Meaning
Reference to other document containing
further information
Step in a diagram:
The numbers correspond to the order in
which the steps are carried out.
Warning of material losses and environmental pollution
Live electrical area
Pay particular attention.
■
Component must audibly click into place.
or
■
Acoustic signal
■
Fit new component.
or
■
In conjunction with a tool: Clean the surface.
Dispose of component correctly.
Dispose of component at a suitable collection point. Do not dispose of component in
domestic waste.
Intended use
The collectors provide central heating backup and
solar backup for DHW heating. They are only intended
to be installed and operated in sealed systems that
comply with EN 12976 and EN 12977, with due attention paid to the associated installation, service and
operating instructions. Only operate the collectors with
heat transfer medium approved by the manufacturer.
Intended use presupposes that a fixed installation in
conjunction with permissible, system-specific components has been carried out.
Commercial or industrial usage for a purpose other
than heating a building or DHW shall be deemed inappropriate.
Any usage beyond this must be approved by the manufacturer in each individual case.
Incorrect usage of the collectors or the installation system or incorrect operation is prohibited (e.g. the collectors being opened by the system user, failure to
observe the installation instructions). Failure to
observe these instructions can change functions,
endanger life and limb of the user or third parties and
will result in an exclusion of liability.
Incorrect usage also applies if components in the system are modified from their intended use (e.g. through
direct DHW heating in the collector).
Adhere to statutory regulations, especially concerning
the hygiene of potable water.
Symbols
5675 789 GB
![](/html/27/2713/2713b1b959c20126e86e3349c669d7a050ad9599e2930db60c00fe9f162e457f/bg5.png)
5
Vitosol 100-F, 200-F and 300-F, types SV and SH, are
high performance flat-plate collectors.
The fixing system, with statically-tested and corrosionresistant components made from stainless steel and
aluminium, is easy to assemble.
The following component assemblies are available for
collector types SV and SH, for a 30°, 45° or 60° angle
of collector inclination.
Collector support, standard kit and collector kit extension
■
Standard kit: 2 collector supports
■
Extension: 1 collector support
Fig.1
1
Collector support with footplates
2
Washer 7 8.4 mm
3
Hexagon bolt M 8 x 25
4
Clamping bracket
5
Self-tapping screw
Retaining rail 6 for 1 collector
Fig.2
Product information
5675 789 GB